Advertisement for orthosearch.org.uk
Results 21 - 40 of 44
Results per page:
Bone & Joint Research
Vol. 7, Issue 1 | Pages 1 - 5
1 Jan 2018
Parsons N Griffin XL Achten J Chesser TJ Lamb SE Costa ML

Objectives

This study investigates the reporting of health-related quality of life (HRQoL) in patients following hip fracture. We compare the relative merits and make recommendations for the use for two methods of measuring HRQoL; (i) including patients who died during follow-up and (ii) including survivors only.

Methods

The World Hip Trauma Evaluation has previously reported changes in HRQoL using EuroQol-5D for patients with hip fractures. We performed additional analysis to investigate the effect of including or excluding those patients who died during the first four months of the follow-up period.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 563 - 565
1 May 2017
Perry DC Griffin XL Dritsaki M Costa ML Parsons N


Bone & Joint Research
Vol. 6, Issue 4 | Pages 204 - 207
1 Apr 2017
Fernandez MA Aquilina A Achten J Parsons N Costa ML Griffin XL

Objectives

The Sliding Hip Screw (SHS) is commonly used to treat trochanteric hip fractures. Fixation failure is a devastating complication requiring complex revision surgery. One mode of fixation failure is lag screw cut-out which is greatest in unstable fracture patterns and when the tip-apex distance of the lag screw is > 25 mm. The X-Bolt Dynamic Hip Plating System (X-Bolt Orthopaedics, Dublin, Ireland) is a new device which aims to reduce this risk of cut-out. However, some surgeons have reported difficulty minimising the tip-apex distance with subsequent concerns that this may lead to an increased risk of cut-out.

Patients and Methods

We measured the tip-apex distance from the intra-operative radiographs of 93 unstable trochanteric hip fractures enrolled in a randomised controlled trial (Warwick Hip Trauma Evaluation, WHiTE One trial). Participants were treated with either the sliding hip screw or the X-Bolt dynamic hip plating system. We also recorded the incidence of cut-out in both groups, at a median follow-up time of 17 months.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 419 - 420
1 Apr 2017
Costa ML Griffin XL Parsons N Dritsaki M Perry D


Aims

The optimal treatment for independent patients with a displaced intracapsular fracture of the hip remains controversial. The recognised alternatives are hemiarthroplasty and total hip arthroplasty. At present there is no established standard of care, with both types of arthroplasty being used in many centres.

Patients and Methods

We conducted a feasibility study comparing the clinical effectiveness of a dual mobility acetabular component compared with standard polyethylene component in total hip arthroplasty for independent patients with a displaced intracapsular fracture of the hip, for a 12-month period beginning in June 2013. The primary outcome was the risk of dislocation one year post-operatively. Secondary outcome measures were EuroQol 5 Dimensions, ICEpop CAPability measure for Older people, Oxford hip score, mortality and re-operation.


Objectives

The annual incidence of hip fracture is 620 000 in the European Union. The cost of this clinical problem has been estimated at 1.75 million disability-adjusted life years lost, equating to 1.4% of the total healthcare burden in established market economies. Recent guidance from The National Institute for Health and Clinical Excellence (NICE) states that research into the clinical and cost effectiveness of total hip arthroplasty (THA) as a treatment for hip fracture is a priority. We asked the question: can a trial investigating THA for hip fracture currently be delivered in the NHS?

Methods

We performed a contemporaneous process evaluation that provides a context for the interpretation of the findings of WHiTE Two – a randomised study of THA for hip fracture. We developed a mixed methods approach to situate the trial centre within the context of wider United Kingdom clinical practice. We focused on fidelity, implementation, acceptability and feasibility of both the trial processes and interventions to stakeholder groups, such as healthcare providers and patients.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 846 - 850
1 Jun 2016
Hoskins W Sheehy R Edwards ER Hau RC Bucknill A Parsons N Griffin XL

Aims

Fractures of the distal femur are an important cause of morbidity. Their optimal management remains controversial. Contemporary implants include angular-stable anatomical locking plates and locked intramedullary nails (IMNs). We compared the long-term patient-reported functional outcome of fixation of fractures of the distal femur using these two methods of treatment.

Patients and Methods

A total of 297 patients were retrospectively identified from a State-wide trauma registry in Australia: 195 had been treated with a locking plate and 102 with an IMN. Baseline characteristics of the patients and their fractures were recorded. Health-related quality-of-life, functional and radiographic outcomes were compared using mixed effects regression models at six months and one year.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 686 - 689
1 May 2016
Griffin XL Parsons N McArthur J Achten J Costa ML

Aims

The aim of this study was to inform a definitive trial which could determine the clinical effectiveness of the X-Bolt Dynamic Hip Plating System compared with the sliding hip screw for patients with complex pertrochanteric fragility fractures of the femur.

Patients and Methods

This was a single centre, participant blinded, randomised, standard-of-care controlled pilot trial. Patients aged 60 years and over with AO/ASIF A2 and A3 type femoral pertrochanteric fractures were eligible.


Bone & Joint Research
Vol. 5, Issue 1 | Pages 18 - 25
1 Jan 2016
Sims AL Parsons N Achten J Griffin XL Costa ML Reed MR

Background

Approximately half of all hip fractures are displaced intracapsular fractures. The standard treatment for these fractures is either hemiarthroplasty or total hip arthroplasty. The recent National Institute for Health and Care Excellence (NICE) guidance on hip fracture management recommends the use of ‘proven’ cemented stem arthroplasty with an Orthopaedic Device Evaluation Panel (ODEP) rating of at least 3B (97% survival at three years). The Thompsons prosthesis is currently lacking an ODEP rating despite over 50 years of clinical use, likely due to the paucity of implant survival data. Nationally, adherence to these guidelines is varied as there is debate as to which prosthesis optimises patient outcomes.

Design

This study design is a multi-centre, multi-surgeon, parallel, two arm, standard-of-care pragmatic randomised controlled trial. It will be embedded within the WHiTE Comprehensive Cohort Study (ISRCTN63982700). The main analysis is a two-way equivalence comparison between Hemi-Thompson and Hemi-Exeter polished taper with Unitrax head. Secondary outcomes will include radiological leg length discrepancy measured as per Bidwai and Willett, mortality, re-operation rate and indication for re-operation, length of index hospital stay and revision at four months. This study will be supplemented by the NHFD (National Hip Fracture Database) dataset.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 875 - 879
1 Jul 2015
Fernandez MA Griffin XL Costa ML

Hip fracture is a common injury associated with high mortality, long-term disability and huge socio-economic burden. Yet there has been relatively little research into best treatment, and evidence that has been generated has often been criticised for its poor quality. Here, we discuss the advances made towards overcoming these criticisms and the future directions for hip fracture research: how co-ordinating existing national infrastructures and use of now established clinical research networks will likely go some way towards overcoming the practical and financial challenges of conducting large trials. We highlight the importance of large collaborative pragmatic trials to inform decision/policy makers and the progress made towards reaching a consensus on a core outcome set to facilitate data pooling for evidence synthesis and meta-analysis.

These advances and future directions are a priority in order to establish the high-quality evidence base required for this important group of patients.

Cite this article: Bone Joint J 2015;97-B:875–9.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 372 - 382
1 Mar 2015
Griffin XL Parsons N Achten J Fernandez M Costa ML

Hip fracture is a global public health problem. The National Hip Fracture Database provides a framework for service evaluation in this group of patients in the United Kingdom, but does not collect patient-reported outcome data and is unable to provide meaningful data about the recovery of quality of life.

We report one-year patient-reported outcomes of a prospective cohort of patients treated at a single major trauma centre in the United Kingdom who sustained a hip fracture between January 2012 and March 2014.

There was an initial marked decline in quality of life from baseline measured using the EuroQol 5 Dimensions score (EQ-5D). It was followed by a significant improvement to 120 days for all patients. Although their quality of life improved during the year after the fracture, it was still significantly lower than before injury irrespective of age group or cognitive impairment (mean reduction EQ-5D 0.22; 95% confidence interval (CI) 0.17 to 0.26). There was strong evidence that quality of life was lower for patients with cognitive impairment. There was a mean reduction in EQ-5D of 0.28 (95% CI 0.22 to 0.35) in patients <  80 years of age. This difference was consistent (and fixed) throughout follow-up. Quality of life does not improve significantly during recovery from hip fracture in patients over 80 years of age (p = 0.928). Secondary measures of function showed similar trends.

Hip fracture marks a step down in the quality of life of a patient: it accounts for approximately 0.22 disability adjusted life years in the first year after fracture. This is equivalent to serious neurological conditions for which extensive funding for research and treatment is made available.

Cite this article: Bone Joint J 2015;97-B:372–82.


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1000 - 1001
1 Aug 2014
Griffin XL Haddad FS


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1016 - 1023
1 Aug 2014
Haywood KL Griffin XL Achten J Costa ML

The lack of a consensus for core health outcomes that should be reported in clinical research has hampered study design and evidence synthesis. We report a United Kingdom consensus for a core outcome set (COS) for clinical trials of patients with a hip fracture.

We adopted a modified nominal group technique to derive consensus on 1) which outcome domains should be measured, and 2) methods of assessment. Participants reflected a diversity of perspectives and experience. They received an evidence synthesis and postal questionnaire in advance of the consensus meeting, and ranked the importance of candidate domains and the relevance and suitability of short-listed measures. During the meeting, pre-meeting source data and questionnaire responses were summarised, followed by facilitated discussion and a final plenary session. A COS was determined using a closed voting system: a 70% consensus was required.

Consensus supported a five-domain COS: mortality, pain, activities of daily living, mobility, and health-related quality of life (HRQL). Single-item measures of mortality and mobility (indoor/outdoor walking status) and a generic multi-item measure of HRQL - the EuroQoL EQ-5D - were recommended. These measures should be included as a minimum in all hip fracture trials. Other outcome measures should be added depending on the particular interventions being studied.

Cite this article: Bone Joint J 2014; 96-B:1016–23.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 853 - 854
1 Jul 2014
Parsons N Griffin XL Stengel D Carey Smith R Perry DC Costa ML

The Bone & Joint Journal provides the latest evidence to guide the clinical practice of orthopaedic surgeons. The benefits of one intervention compared with another are presented using outcome measures; some may be specific to a limb or joint and some are more general health-related quality of life measures. Readers will be familiar with many of these outcome measures and will be able to judge the relative benefits of different interventions when measured using the same outcome tool; for example, different treatments for pain in the knee measured using a particular knee score. But, how should readers compare outcomes between different clinical areas using different outcome measures? This article explores the use of standardised effect sizes.

Cite this article: Bone Joint J 2014;96-B:853–4.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 652 - 657
1 May 2014
Griffin XL Parsons N Achten J Costa ML

We compared a new fixation system, the Targon Femoral Neck (TFN) hip screw, with the current standard treatment of cannulated screw fixation. This was a single-centre, participant-blinded, randomised controlled trial. Patients aged 65 years and over with either a displaced or undisplaced intracapsular fracture of the hip were eligible. The primary outcome was the risk of revision surgery within one year of fixation.

A total of 174 participants were included in the trial. The absolute reduction in risk of revision was of 4.7% (95% CI 14.2 to 22.5) in favour of the TFN hip screw (chi-squared test, p = 0.741), which was less than the pre-specified level of minimum clinically important difference. There were no significant differences in any of the secondary outcome measures.

We found no evidence of a clinical difference in the risk of revision surgery between the TFN hip screw and cannulated screw fixation for patients with an intracapsular fracture of the hip.

Cite this article: Bone Joint J 2014;96-B:652–7.


Bone & Joint Research
Vol. 3, Issue 4 | Pages 123 - 129
1 Apr 2014
Perry DC Griffin XL Parsons N Costa ML

The surgical community is plagued with a reputation for both failing to engage and to deliver on clinical research. This is in part due to the absence of a strong research culture, however it is also due to a multitude of barriers encountered in clinical research; particularly those involving surgical interventions. ‘Trauma’ amplifies these barriers, owing to the unplanned nature of care, unpredictable work patterns, the emergent nature of treatment and complexities in the consent process. This review discusses the barriers to clinical research in surgery, with a particular emphasis on trauma. It considers how barriers may be overcome, with the aim to facilitate future successful clinical research.

Cite this article: Bone Joint Res 2014;3:123–9.


Bone & Joint Research
Vol. 3, Issue 3 | Pages 69 - 75
1 Mar 2014
Parsons N Griffin XL Achten J Costa ML

Objectives

To study the measurement properties of a joint specific patient reported outcome measure, a measure of capability and a general health-related quality of life (HRQOL) tool in a large cohort of patients with a hip fracture.

Methods

Responsiveness and associations between the Oxford Hip Score (a hip specific measure: OHS), ICEpop CAPability (a measure of capability in older people: ICECAP-O) and EuroQol EQ-5D (general health-related quality of life measure: EQ-5D) were assessed using data available from two large prospective studies. The three outcome measures were assessed concurrently at a number of fixed follow-up time-points in a consecutive sequence of patients, allowing direct assessment of change from baseline, inter-measure associations and validity using a range of statistical methods.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1443 - 1444
1 Nov 2013
Griffin XL Parsons N Carey Smith R Stengel D Costa ML

The importance for observing the intention-to-treat approach in clinical studies is explained.

Cite this article: Bone Joint J 2013;95-B:1443–4.


Bone & Joint Research
Vol. 2, Issue 10 | Pages 210 - 213
1 Oct 2013
Griffin XL McArthur J Achten J Parsons N Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. Controversy exists regarding the optimal treatment for independent patients with displaced intracapsular fractures of the proximal femur. The recognised alternatives are hemiarthroplasty and total hip replacement. At present there is no established standard of care, with both types of arthroplasty being used in many centres. The principal advantages of total hip replacement are a functional benefit over hemiarthroplasty and a reduced risk of revision surgery. The principal criticism is the increased risk of dislocation. We believe that an alternative acetabular component may reduce the risk of dislocation but still provide the functional benefit of total hip replacement in these patients. We therefore propose to investigate the dislocation risk of a dual-mobility acetabular component compared with standard polyethylene component in total hip replacement for independent patients with displaced intracapsular fractures of the proximal femur within the framework of the larger WHiTE (Warwick Hip Trauma Evaluation) Comprehensive Cohort Study.

Cite this article: Bone Joint Res 2013;2:210–13.


Bone & Joint Research
Vol. 2, Issue 10 | Pages 206 - 209
1 Oct 2013
Griffin XL McArthur J Achten J Parsons N Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. Controversy exists regarding the optimal treatment for patients with unstable trochanteric proximal femoral fractures. The recognised treatment alternatives are extramedullary fixation usually with a sliding hip screw and intramedullary fixation with a cephalomedullary nail. Current evidence suggests that best results and lowest complication rates occur using a sliding hip screw. Complications in these difficult fractures are relatively common regardless of type of treatment. We believe that a novel device, the X-Bolt dynamic plating system, may offer superior fixation over a sliding hip screw with lower reoperation risk and better function. We therefore propose to investigate the clinical effectiveness of the X-bolt dynamic plating system compared with standard sliding hip screw fixation within the framework of a the larger WHiTE (Warwick Hip Trauma Evaluation) Comprehensive Cohort Study.

Cite this article: Bone Joint Res 2013;2:206–9.