Aims. Debate remains whether the patella should be resurfaced during total knee replacement (TKR). For non-resurfaced TKRs, we estimated what the revision rate would have been if the patella had been resurfaced, and examined the risk of re-revision following secondary patellar resurfacing. Methods. A retrospective observational study of the National Joint Registry (NJR) was performed. All primary TKRs for osteoarthritis alone performed between 1 April 2003 and 31 December 2016 were eligible (n = 842,072). Patellar resurfacing during TKR was performed in 36% (n = 305,844). The primary outcome was all-cause
Objectives. The Kaplan-Meier estimation is widely used in orthopedics to
calculate the probability of
Aims. The aim of this study was to examine the results of revision
total knee arthroplasty (TKA) undertaken for stiffness in the absence
of sepsis or loosening. Patients and Methods. We present the results of
Aims. The primary aim of this study was to determine if delayed clavicular fixation results in a greater risk of operative complications and
Objectives. Few studies have assessed outcomes following non-metal-on-metal hip arthroplasty (non-MoMHA)
Aims. The aim of this large registry-based study was to compare mid-term survival rates of cemented femoral stems of different designs used in hemiarthroplasty for a fracture of the femoral neck. Patients and Methods. From the Norwegian Hip Fracture Register (NHFR), 20 532 primary cemented bipolar hemiarthroplasties, which were undertaken in patients aged > 70 years with a femoral neck fracture between 2005 and 2016, were included. Polished tapered stems (n = 12 065) (Exeter and CPT), straight stems (n = 5545) (Charnley, Charnley Modular, and Spectron EF), and anatomical stems (n = 2922) (Lubinus SP2) were included. The survival of the implant with any
Custom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research focusing on tumour cases and implant flange positioning precision remains limited. Additionally, the impact of intraoperative navigation on positioning accuracy warrants further investigation. This study assesses CTAC positioning accuracy in tumour resection and rTHA cases, focusing on the differences between preoperative planning and postoperative implant positions. A multicentre observational cohort study in Australia between February 2017 and March 2021 included consecutive patients undergoing acetabular reconstruction with CTACs in rTHA (Paprosky 3A/3B defects) or tumour resection (including Enneking P2 peri-acetabular area). Of 103 eligible patients (104 hips), 34 patients (35 hips) were analyzed.Aims
Methods
Aims. The aims of this study were to determine the rates of surgical complications,
Impacted morsellised allografts have been used successfully to address the problem of poor bone stock in
Proximal femoral endoprosthetic replacements (PFEPRs) are the most common reconstruction option for osseous defects following primary and metastatic tumour resection. This study aimed to compare the rate of implant failure between PFEPRs with monopolar and bipolar hemiarthroplasties and acetabular arthroplasties, and determine the optimum articulation for revision PFEPRs. This is a retrospective review of 233 patients who underwent PFEPR. The mean age was 54.7 years (SD 18.2), and 99 (42.5%) were male. There were 90 patients with primary bone tumours (38.6%), 122 with metastatic bone disease (52.4%), and 21 with haematological malignancy (9.0%). A total of 128 patients had monopolar (54.9%), 74 had bipolar hemiarthroplasty heads (31.8%), and 31 underwent acetabular arthroplasty (13.3%).Aims
Methods
The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid total hip arthroplasties (THAs). We undertook a registry study combining the National Joint Registry dataset with polyethylene manufacturing characteristics as supplied by the manufacturers. The primary endpoint was revision for any reason. We performed further analyses on other reasons including instability, aseptic loosening, wear, and liner dissociation. The primary analytic approach was Cox proportional hazard regression.Aims
Methods
We have reviewed 22 patients from a total of 135 treated by autologous chondrocyte implantation (ACI) who had undergone further surgery for pain in the knee and mechanical symptoms after a mean of 10.5 months. There were 31 grafted lesions. At operation the findings included lifting (24/31) and detachment (3/31) of periosteal patches for which arthroscopic shaving was performed. Chondroplasty was undertaken on two new lesions, another required an ACI and a further patient required trimming of a meniscus. The mechanical symptoms resolved within two weeks. At the last review, two to 14 months from
Revision operations after fracture of the hip are costly, in both monetary and personal terms. We have assessed whether these costs applied equally to all complications after the primary procedure. We studied 3154 consecutive patients with fracture of the hip and analysed the complications and financial implications related to
A new approach to the hip is described that allows better exposure for difficult
We have reviewed the results of one-stage
The mechanical performance of the cement-in-cement interface in
Metal meshes are used in
The aim of this study was to identify the effect of the manufacturing characteristics of polyethylene acetabular liners on the survival of cementless and hybrid total hip arthroplasty (THA). Prospective cohort study using linked National Joint Registry (NJR) and manufacturer data. The primary endpoint was revision for aseptic loosening. Cox proportional hazard regression was the primary analytical approach. Manufacturing variables included resin type, crosslinking radiation dose, terminal sterilization method, terminal sterilization radiation dose, stabilization treatment, total radiation dose, packaging, and face asymmetry. Total radiation dose was further divided into G1 (no radiation), G2 (> 0 Mrad to < 5 Mrad), G3 (≥ 5 Mrad to < 10 Mrad), and G4 (≥ 10 Mrad).Aims
Methods
The factors that predispose to recurrent instability and revision
stabilization procedures after arthroscopic Bankart repair for anterior
glenohumeral instability remain unclear. We sought to determine
the rate and risk factors associated with ongoing instability in
patients undergoing arthroscopic Bankart repair for instability
of the shoulder. We used the Statewide Planning and Research Cooperative System
(SPARCS) database to identify patients with a diagnosis of anterior
instability of the shoulder undergoing arthroscopic Bankart repair
between 2003 and 2011. Patients were followed for a minimum of three
years. Baseline demographics and subsequent further surgery to the ipsilateral
shoulder were analyzed. Multivariate analysis was used to identify
independent risk factors for recurrent instability.Aims
Materials and Methods