This study compared the quality of reduction
and complication rate when using a standard ilioinguinal approach and
the new pararectus approach when treating acetabular fractures surgically.
All acetabular fractures that underwent fixation using either approach
between February 2005 and September 2014 were retrospectively reviewed
and the demographics of the patients, the surgical details and complications
were recorded. A total of 100 patients (69 men, 31 women; mean age 57 years,
18 to 93) who were consecutively treated were included for analysis.
The quality of reduction was assessed using standardised measurement
of the gaps and steps in the articular surface on pre- and post-operative
CT-scans. There were no significant differences in the demographics of
the patients, the surgical details or the complications between
the two approaches. A significantly better reduction of the gap,
however, was achieved with the pararectus approach (axial: p = 0.025,
coronal: p = 0.013, sagittal: p = 0.001). These data suggest that the pararectus approach is at least equal
to, or in the case of reduction of the articular gap, superior to
the ilioinguinal approach. This approach allows direct buttressing of the dome of the acetabulum
and the quadrilateral plate, which is particularly favourable in
geriatric fracture patterns. Cite this article:
Medial unicompartmental knee arthroplasty (UKA) is associated
with successful outcomes in carefully selected patient cohorts.
We hypothesised that severity and location of patellofemoral cartilage
lesions significantly influences functional outcome after Oxford
medial compartmental knee arthroplasty. We reviewed 100 consecutive UKAs at minimum eight-year follow-up
(96 to 132). A single surgeon performed all procedures. Patients
were selected based on clinical and plain radiographic assessment.
All patients had end-stage medial compartment osteoarthritis (OA)
with sparing of the lateral compartment and intact anterior cruciate ligaments.
None of the patients had end-stage patellofemoral OA, but patients
with anterior knee pain or partial thickness chondral loss were
not excluded. There were 57 male and 43 female patients. The mean
age at surgery was 69 years (41 to 82). At surgery the joint was
carefully inspected for patellofemoral chondral loss and this was documented
based on severity of cartilage loss (0 to 4 Outerbridge grading)
and topographic location (medial, lateral, central, and superior
or inferior). Functional scores collected included Oxford Knee Score
(OKS), patient satisfaction scale and University College Hospital
(UCH) knee score. Intraclass correlation was used to compare chondral
damage to outcomes.Aims
Patients and Methods
Risk of revision following total knee arthroplasty (TKA) is higher
in patients under 55 years, but little data are reported regarding
non-revision outcomes. This study aims to identify predictors of
dissatisfaction in these patients. We prospectively assessed 177 TKAs (157 consecutive patients,
99 women, mean age 50 years; 17 to 54) from 2008 to 2013. Age, gender,
implant, indication, body mass index (BMI), social deprivation,
range of movement, Kellgren-Lawrence (KL) grade of osteoarthritis
(OA) and prior knee surgery were recorded. Pre- and post-operative
Oxford Knee Score (OKS) as well as Short Form-12 physical (PCS)
and mental component scores were obtained. Post-operative range
of movement, complications and satisfaction were measured at one
year.Aims
Patients and Methods
To examine the mid-term outcome and cost utility of the BioPro
metallic hemiarthroplasty for the treatment of hallux rigidius. We reviewed 97 consecutive BioPro metallic hemiarthroplasties
performed in 80 patients for end-stage hallux rigidus, with a minimum
follow-up of five years. There were 19 men and 61 women; their mean
age was 55 years (22 to 74). No patient was lost to follow-up.Aims
Patients and Methods
The aims of our study were to provide long-term information on
the behaviour of the thoracolumbar/lumbar (TL/L) curve after thoracic
anterior correction and fusion (ASF) and to determine the impact
of ASF on pulmonary function. A total of 41 patients (four males, 37 females) with main thoracic
(MT) adolescent idiopathic scoliosis (AIS) treated with ASF were
included. Mean age at surgery was 15.2 years (11 to 27). Mean follow-up
period was 13.5 years (10 to 18).Aims
Patients and Methods
Nail patella syndrome (NPS) is a skeletal dysplasia with patellofemoral
dysfunction as a key symptom. We present the first in-depth radiological
evaluation of the knee in a large series of NPS patients and describe
the typical malformations. Conventional radiological examination of 95 skeletally mature
patients with NPS was performed. Patellar morphology was classified
according to the Wiberg classification as modified by Baumgartl
and Ficat criteria, and trochlear shape was classified according
to the Dejour classification.Aim
Patients and Methods
Oxidised zirconium was introduced as a material for femoral components
in total knee arthroplasty (TKA) as an attempt to reduce polyethylene
wear. However, the long-term survival of this component is not known. We performed a retrospective review of a prospectively collected
database to assess the ten year survival and clinical and radiological
outcomes of an oxidised zirconium total knee arthroplasty with the
Genesis II prosthesis. The Western Ontario and McMaster Universities Osteoarthritis
Index (WOMAC), Knee Injury and Osteoarthritis Outcome Score (KOOS)
and a patient satisfaction scale were used to assess outcome.Aims
Methods
The accurate reconstruction of hip anatomy and
biomechanics is thought to be important in achieveing good clinical
outcomes following total hip arthroplasty (THA). To this end some
newer hip designs have introduced further modularity into the design
of the femoral component such that neckshaft angle and anteversion,
which can be adjusted intra-operatively. The clinical effect of
this increased modularity is unknown. We have investigated the changes
in these anatomical parameters following conventional THA with a
prosthesis of predetermined neck–shaft angle and assessed the effect
of changes in the hip anatomy on clinical outcomes. In total, 44 patients (mean age 65.3 years (standard deviation
( The mean pre-operative neck–shaft angle was significantly increased
by 2.8° from 128° ( Cite this article:
Controversy remains whether the contralateral
hip should be fixed in patients presenting with unilateral slipped capital
femoral epiphysis (SCFE). This retrospective study compares the
outcomes and cost of those patients who had prophylactic fixation
with those who did not. Between January 2000 and December 2010 a total of 50 patients
underwent unilateral fixation and 36 had prophylactic fixation of
the contralateral hip. There were 54 males and 32 females with a
mean age of 12.3 years (9 to 16). The rate of a subsequent slip
without prophylactic fixation was 46%. The risk of complications
was greater, the generic health measures (Short Form-12 physical
(p <
0.001) and mental (p = 0.004) summary scores) were worse.
Radiographic cam lesions in patients presenting with unilateral
SCFE were only seen in patients who did not have prophylactic fixation.
Furthermore, prophylactic fixation of the contralateral hip was
found to be a cost-effective procedure, with a cost per quality
adjusted life year gained of £1431 at the time of last follow-up. Prophylactic fixation of the contralateral hip is a cost-effective
operation that limits the morbidity from the complications of a
further slip, and the diminished functional outcome associated with
unilateral fixation. Cite this article:
Failed internal fixation of a fracture of the
proximal humerus produces many challenges with limited surgical options.
The aim of this study was to evaluate the clinical outcomes after
the use of a reverse shoulder arthroplasty under these circumstances.
Between 2007 and 2012, 19 patients (15 women and four men, mean
age 66 years; 52 to 82) with failed internal fixation after a proximal
humeral fracture, underwent implant removal and reverse shoulder arthroplasty
(RSA). The mean follow-up was 36 months (25 to 60). The mean American
Shoulder and Elbow Score improved from 27.8 to 50.1 (p = 0.019).
The mean Simple Shoulder Test score improved from 0.7 to 3.2 (p
= 0.020), and the mean visual analogue scale for pain improved from
6.8 to 4.3 (p = 0.012). Mean forward flexion improved from 58.7°
to 101.1° (p <
0.001), mean abduction from 58.7° to 89.1° (p
= 0.012), mean external rotation from 10.7° to 23.1° (p = 0.043)
and mean internal rotation from buttocks to L4 (p = 0.034). A major
complication was recorded in five patients (26%) (one intra-operative
fracture, loosening of the humeral component in two and two peri-prosthetic
fractures). A total of 15 patients (79%) rated their outcome as
excellent or good, one (5%) as satisfactory, and three (16%) as
unsatisfactory. An improvement in outcomes and pain can be expected when performing
a RSA as a salvage procedure after failed internal fixation of a
fracture of the proximal humerus. Patients should be cautioned about
the possibility for major complications following this technically
demanding procedure. Cite this article:
Primary total knee arthroplasty (TKA) is a reliable
procedure with reproducible long-term results. Nevertheless, there
are conditions related to the type of patient or local conditions
of the knee that can make it a difficult procedure. The most common
scenarios that make it difficult are discussed in this review. These
include patients with many previous operations and incisions, and
those with severe coronal deformities, genu recurvatum, a stiff knee,
extra-articular deformities and those who have previously undergone
osteotomy around the knee and those with chronic dislocation of
the patella. Each condition is analysed according to the characteristics of
the patient, the pre-operative planning and the reported outcomes. When approaching the difficult primary TKA surgeons should use
a systematic approach, which begins with the review of the existing
literature for each specific clinical situation. Cite this article:
Unlinked, linked and convertible total elbow
arthroplasties (TEAs) are currently available. This study is the
first to report the clinical results of the convertible Latitude
TEA. This was a retrospective study of a consecutive cohort of 63
patients (69 primary TEAs) with a mean age of 60 years (23 to 87).
Between 2006 and 2008 a total of 19 men and 50 women underwent surgery.
The mean follow-up was 43 months (8 to 84). The range of movement,
function and pain all improved six months post-operatively and either
continued to improve slightly or reached a plateau thereafter. The
complication rate is similar to that reported for other TEA systems.
No loosening was seen. Remarkable is the disengagement of the radial
head component in 13 TEAs (31%) with a radial head component implanted. Implantation of both the linked and the unlinked versions of
the Latitude TEA results in improvement of function and decreased
pain, and shows high patient satisfaction at mid-term follow-up. Cite this article:
A clinical investigation into a new bone void filler is giving
first data on systemic and local exposure to the anti-infective
substance after implantation. A total of 20 patients with post-traumatic/post-operative bone
infections were enrolled in this open-label, prospective study.
After radical surgical debridement, the bone cavity was filled with
this material. The 21-day hospitalisation phase included determination
of gentamicin concentrations in plasma, urine and wound exudate, assessment
of wound healing, infection parameters, implant resorption, laboratory
parameters, and adverse event monitoring. The follow-up period was
six months. Objective
Method
We assessed the clinical results, radiographic
outcomes and complications of patients undergoing total shoulder replacement
(TSR) for osteoarthritis with concurrent repair of a full-thickness
rotator cuff tear. Between 1996 and 2010, 45 of 932 patients (4.8%)
undergoing TSR for osteoarthritis underwent rotator cuff repair.
The final study group comprised 33 patients with a mean follow-up
of 4.7 years (3 months to 13 years). Tears were classified into small
(10), medium (14), large (9) or massive (0). On a scale of 1 to
5, pain decreased from a mean of 4.7 to 1.7 (p = <
0.0001), the
mean forward elevation improved from 99° to 139° (p = <
0.0001),
and the mean external rotation improved from 20° (0° to 75°) to
49° (20° to 80°) (p = <
0.0001). The improvement in elevation
was greater in those with a small tear (p = 0.03). Radiographic
evidence of instability developed in six patients with medium or
large tears, indicating lack of rotator cuff healing. In all, six
glenoid components, including one with instability, were radiologically
at risk of loosening. Complications were noted in five patients,
all with medium or large tears; four of these had symptomatic instability
and one sustained a late peri-prosthetic fracture. Four patients
(12%) required further surgery, three with instability and one with
a peri-prosthetic humeral fracture. Consideration should be given to performing rotator cuff repair
for stable shoulders during anatomical TSR, but reverse replacement
should be considered for older, less active patients with larger
tears. Cite this article:
We have investigated the mid-term outcome of total shoulder replacement using a keeled cemented glenoid component and a modern cementing technique with regard to the causes of failure and loosening of the components. Between 1997 and 2003 we performed 96 total shoulder replacements on 88 patients, 24 men and 64 women with a mean age of 69.7 years (31 to 82). The minimum follow-up was five years and at the time of review 87 shoulders (77 patients) were examined at a mean follow-up of 89.1 months (60 to 127). Cumulative survival curves were generated with re-operations (accomplished and planned), survivorship of the proshesis, loosening of the glenoid (defined as tilt >
5° or subsidence >
5 mm), the presence of radiolucent lines and a Constant score of <
30 as the endpoints. There were two re-operations not involving revision of the implants and the survival rate of the prosthesis was 100.0% for the follow-up period, with an absolute Constant score of >
30 as the endpoint the survival rate was 98%. Radiological glenoid loosening was 9% after five years, and 33% after nine years. There was an incidence of 8% of radiolucent lines in more than three of six zones in the immediate post-operative period, of 37.0% after the first year which increased to 87.0% after nine years. There was no correlation between the score of Boileau and the total Constant score at the latest follow-up, but there was correlation between glenoid loosening and pain (p = 0.001). We found that total shoulder replacement had an excellent mid-term survivorship and clinical outcome. The surgical and cementing techniques were related to the decrease in radiolucent lines around the glenoid compared with earlier studies. One concern, however, was the fact that radiolucent lines increased over time and there was a rate of glenoid loosening of 9% after five years and 33% after nine years. This suggests that the design of the glenoid component, and the implantation and cementing techniques may need further improvement.
Early failure associated with adverse reactions to metal debris is an emerging problem after hip resurfacing but the exact mechanism is unclear. We analysed our entire series of 660 metal-on-metal resurfacings (Articular Surface Replacement (ASR) and Birmingham Hip Resurfacing (BHR)) and large-bearing ASR total hip replacements, to establish associations with metal debris-related failures. Clinical and radiological outcomes, metal ion levels, explant studies and lymphocyte transformation tests were performed. A total of 17 patients (3.4%) were identified (all ASR bearings) with adverse reactions to metal debris, for which revision was required. This group had significantly smaller components, significantly higher acetabular component anteversion, and significantly higher whole concentrations of blood and joint chromium and cobalt ions than asymptomatic patients did (all p <
0.001). Post-revision lymphocyte transformation tests on this group showed no reactivity to chromium or cobalt ions. Explants from these revisions had greater surface wear than retrievals for uncomplicated fractures. The absence of adverse reactions to metal debris in patients with well-positioned implants usually implies high component wear. Surgeons must consider implant design, expected component size and acetabular component positioning in order to reduce early failures when performing large-bearing metal-on-metal hip resurfacing and replacement.
We used roentgen stereophotogrammetric analysis to follow 33 C-stem femoral components for two years after primary total hip arthroplasty. All components migrated distally and posteriorly within the cement mantle. The mean distal migration was 1.35 mm (
We investigated the rate of polyethylene wear of a cementless acetabular component at different periods of follow-up in order to test the hypothesis than an irrecoverable deformation process (creep) was followed by an initially low, but gradually increasing wear rate. We studied prospectively 93 uncemented total hip arthroplasties in 83 patients (mean age 50 years (22 to 63)) with a mean follow-up of 8.2 years (3 to 12). We measured the penetration of the femoral head from radiographs taken immediately after surgery at three, six and nine years, or at the latest follow-up. The median wear rate was 0.17 mm per year in the first three years, a finding which we considered to be caused by creep. Thereafter, the rate of wear declined to 0.07 mm per year (four- to six-year period) and then increased to 0.17 mm per year (seven to nine years) and 0.27 mm per year (more than nine years), which we considered to be a reflection of genuine polyethylene wear. After the nine-year follow-up the wear rates were higher in patients with marked osteolysis. We found no relationship between the inclination angle of the acetabular component or femoral head orientation and the rate of wear. No acetabular component required revision.
We describe the experience with the first consecutive 230 Birmingham hip resurfacings at our centre. At a mean follow-up of three years (25 to 52 months) survivorship was 99.14% with revision in one patient for a loose acetabular component and one death from unrelated causes. One patient developed a fracture of the femoral neck at six weeks which united unremarkably after a period of non-weight-bearing. The Harris hip score improved from a mean of 62.54 (8 to 92) to 97.74 (61 to 100). The mean flexion improved from 91.52° (25 to 140) to 110.41° (80 to 145). Most patients (97%) considered the outcome to be good or excellent. Our preliminary experience with this implant is encouraging and the results are superior to the earlier generation of resurfacings for the same length of follow-up.