Advertisement for orthosearch.org.uk
Results 21 - 40 of 2217
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 244 - 249
1 Mar 1996
Judet T de Loubresse CG Piriou P Charnley G

We report our experience over seven years with a floating radial-head prosthesis for acute fractures of the radial head and the complications which may result from such injury. The prosthesis has an integrated articulation which allows change of position during movement of the elbow. We present the results in 12 patients with a minimum follow-up of two years. Five prostheses had been implanted shortly after injury with an average follow-up of 49 months and seven for the treatment of sequelae with an average follow-up of 43 months. All prostheses have performed well with an improved functional score (modified from Broberg and Morrey 1986). We have not experienced any of the complications previously reported with silicone radial-head replacement. Our initial results suggest that the prosthesis may be suitable for the early or delayed treatment of Mason type-III fractures and more complex injuries involving the radial head


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 461 - 469
1 Apr 2019
Lädermann A Schwitzguebel AJ Edwards TB Godeneche A Favard L Walch G Sirveaux F Boileau P Gerber C

Aims

The aim of this study was to report the outcomes of different treatment options for glenoid loosening following reverse shoulder arthroplasty (RSA) at a minimum follow-up of two years.

Patients and Methods

We retrospectively studied the records of 79 patients (19 men, 60 women; 84 shoulders) aged 70.4 years (21 to 87) treated for aseptic loosening of the glenosphere following RSA. Clinical evaluation included pre- and post-treatment active anterior elevation (AAE), external rotation, and Constant score.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 508 - 512
1 Apr 2005
Lafuente J Casey ATH Petzold A Brew S

We present data relating to the Bryan disc arthroplasty for the treatment of cervical spondylosis in 46 patients. Patients with either radiculopathy or myelopathy had a cervical discectomy followed by implantation of a cervical disc prosthesis. Patients were reviewed at six weeks, six months and one year and assessment included three outcome measures, a visual analogue scale (VAS), the short form 36 (SF-36) and the neck disability index (NDI). The results were categorised according to a modification of Odom’s criteria. Radiological evaluation, by an independent radiologist, sought evidence of movement, stability and subsidence of the prosthesis. A highly significant difference was found for all three outcome measurements, comparing the pre-operative with the post-operative values: VAS (Z = 6.42, p < 0.0001), SF-36 (mental component) (Z = −5.02, p < 0.0001), SF-36 (physical component) (Z = −5.00, p < 0.0001) and NDI (Z = 7.03, p < 0.0001). The Bryan cervical disc prosthesis seems reliable and safe in the treatment of patients with cervical spondylosis


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 140 - 144
1 Jan 1988
Lamb D Dick T Douglas W

We describe the development of a body-powered upper limb prosthesis fitted with a cosmetic functioning hand. The features and advantages of the new design--the PMR (Princess Margaret Rose) prosthesis--are discussed and the clinical results in 15 patients fitted with the prosthesis after above-elbow amputation are described


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 762 - 770
1 Jun 2015
Pennington MW Grieve R van der Meulen JH

There is little evidence on the cost effectiveness of different brands of hip prostheses. We compared lifetime cost effectiveness of frequently used brands within types of prosthesis including cemented (Exeter V40 Contemporary, Exeter V40 Duration and Exeter V40 Elite Plus Ogee), cementless (Corail Pinnacle, Accolade Trident, and Taperloc Exceed) and hybrid (Exeter V40 Trilogy, Exeter V40 Trident, and CPT Trilogy). We used data from three linked English national databases to estimate the lifetime risk of revision, quality-adjusted life years (QALYs) and cost. . For women with osteoarthritis aged 70 years, the Exeter V40 Elite Plus Ogee had the lowest risk of revision (5.9% revision risk, 9.0 QALYs) and the CPT Trilogy had the highest QALYs (10.9% revision risk, 9.3 QALYs). Compared with the Corail Pinnacle (9.3% revision risk, 9.22 QALYs), the most commonly used brand, and assuming a willingness-to-pay of £20 000 per QALY gain, the CPT Trilogy is most cost effective, with an incremental net monetary benefit of £876. Differences in cost effectiveness between the hybrid CPT Trilogy and Exeter V40 Trident and the cementless Corail Pinnacle and Taperloc Exceed were small, and a cautious interpretation is required, given the limitations of the available information. However, it is unlikely that cemented brands are among the most cost effective. Similar patterns of results were observed for men and other ages. The gain in quality of life after total hip arthroplasty, rather than the risk of revision, was the main driver of cost effectiveness. Cite this article: Bone Joint J 2015;97-B:762–70


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 3 | Pages 305 - 312
1 Jun 1982
Steinbrink K Engelbrecht E Fenelon G

The use of a total femoral prosthesis can offer a realistic alternative to amputation or disarticulation. The limited indications for such a prosthesis in the surgical management of primary bone tumours and pathological fractures still exist. In this specialised clinic there is an increased need to replace the entire femur where repeated procedures have failed, from loss of bone stock with infection or because of non-union in the presence of a prosthesis. Over the past eight years, four basic models have been developed. The most recent designs allow for the preservation of non-involved bone or for stable support where there is complete acetabular destruction


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1335 - 1340
1 Oct 2009
Kontakis GM Tosounidis TI Christoforakis Z Hadjipavlou AG

We reviewed the outcome of 28 patients who had been treated using the Aequalis fracture prosthesis for an acute fracture of the proximal humerus at a mean follow-up of 39.3 months (24 to 63). The mean age of the patients at the time of the fracture was 66.3 years (38 to 80). The mean Constant score was 68.2 (37 to 84) for the operated shoulder, which represented 89.5% of the mean score for the uninjured side (p < 0.001). The quality of the reconstruction as shown on the immediate post-operative radiographs was categorised into three types, anatomical, acceptable, and unacceptable, depending on the position of the tuberosities relative to the prosthetic head and the humeral shaft. Anatomical reconstruction was associated with a higher mean Constant score as well as higher mean values of anterior forward elevation, abduction and external rotation than the other types, but the differences were not statistically significant (p > 0.231). A total of 18 patients had active anterior elevation ≥150°. Their mean active abduction and external rotation were 163.6° and 31.3°, respectively. In seven of the 28 patients, the mean active anterior elevation, abduction and external rotation were 130.7°, 129.2° and 22.8°, respectively. In all, 12 patients were very satisfied with the results, 12 were satisfied, two were dissatisfied and two were disappointed; 26 reported no or only mild pain while only two had moderate pain. In five patients proximal migration of the humeral head was shown on the anteroposterior radiographs of the shoulder. No evidence of loosening was found in any prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 760 - 764
1 Jun 2006
Dotzis A Cochu G Mabit C Charissoux JL Arnaud JP

Excision is not a suitable treatment for all comminuted fractures of the radial head. In elbows where instability can be predicted, a replacement arthroplasty of the radial head is more effective. The aim of this paper was to present the medium-term results of the Judet floating radial head prosthesis. This operation was performed on 14 patients between 1992 and 2003, of whom 12 were reviewed at a mean follow-up of five years and three months (1 to 12 years). The outcome was assessed using the Mayo elbow performance score and a modified Disability of Arm Shoulder Hand (DASH) questionnaire. There were six excellent results, four good, one fair and one poor, as graded by the Mayo score. The mean DASH score was 23.9/100 (0 to 65.8/100). The only significant complication occurred in one patient who developed a severe complex regional pain syndrome. There were no patients with secondary instability of the elbow, implant loosening, cubitus valgus, osteoporosis of the capitellum, or pain in the forearm and wrist. Our experience, combined with that of other authors using this device, has encouraged us to continue using the Judet prosthesis in comminuted fractures of the elbow where instability is a potential problem


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 20 - 27
1 Jan 2018
Sabah SA Moon JC Jenkins-Jones S Morgan CL Currie CJ Wilkinson JM Porter M Captur G Henckel J Chaturvedi N Kay P Skinner JA Hart AH Manisty C

Aims

The aim of this study was to determine whether patients with metal-on-metal (MoM) arthroplasties of the hip have an increased risk of cardiac failure compared with those with alternative types of arthroplasties (non-MoM).

Patients and Methods

A linkage study between the National Joint Registry, Hospital Episodes Statistics and records of the Office for National Statistics on deaths was undertaken. Patients who underwent elective total hip arthroplasty between January 2003 and December 2014 with no past history of cardiac failure were included and stratified as having either a MoM (n = 53 529) or a non-MoM (n = 482 247) arthroplasty. The primary outcome measure was the time to an admission to hospital for cardiac failure or death. Analysis was carried out using data from all patients and from those matched by propensity score.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 668 - 672
1 May 2013
Abdel MP Hattrup SJ Sperling JW Cofield RH Kreofsky CR Sanchez-Sotelo J

Instability after arthroplasty of the shoulder is difficult to correct surgically. Soft-tissue procedures and revision surgery using unconstrained anatomical components are associated with a high rate of failure. The purpose of this study was to determine the results of revision of an unstable anatomical shoulder arthroplasty to a reverse design prosthesis. Between 2004 and 2007, 33 unstable anatomical shoulder arthroplasties were revised to a reverse design. The mean age of the patients was 71 years (53 to 86) and their mean follow-up was 42 months (25 to 71). The mean time to revision was 26 months (4 to 164). Pain scores improved significantly (pre-operative visual analogue scale (VAS) of 7.2 (. sd. 1.6); most recent VAS 2.2 (. sd. 1.9); p = 0.001). There was a statistically significant increase in mean active forward elevation from 40.2° (. sd. 27.3) to 97.0° (. sd. 36.2) (p = 0.001). There was no significant difference in internal (p = 0.93) or external rotation (p = 0.40). Radiological findings included notching in five shoulders (15%) and heterotopic ossification of the inferior capsular region in three (9%). At the last follow-up 31 shoulders (94%) were stable. The remaining two shoulders dislocated at 2.5 weeks and three months post-operatively, respectively. According to the Neer rating system, there were 13 excellent (40%), ten satisfactory (30%) and ten unsatisfactory results (30%). Revision of hemiarthroplasty or anatomical total shoulder replacement for instability using a reverse design prosthesis gives good short-term results. Cite this article: Bone Joint J 2013;95-B:668–72


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 399 - 405
1 Mar 2014
Zang J Guo W Yang Y Xie L

We report our early experience with the use of a new prosthesis, the Modular Hemipelvic Prosthesis II, for reconstruction of the hemipelvis after resection of a primary malignant peri-acetabular tumour involving the sacroiliac joint. . We retrospectively reviewed the outcome of 17 patients who had undergone resection of a pelvic tumour and reconstruction with this prosthesis between July 2002 and July 2010. One patient had a type I+II+III+IV resection (ilium + peri-acetabulum + pubis/ischium + sacrum) and 16 had a type I+II+IV resection (ilium + acetabulum + sacrum). The outcome was assessed at a mean follow-up of 33 months (15 to 59). One patient was alive with disease, 11 were alive without disease and five had died of disease. The overall five-year survival rate was 62.4%. Six patients had a local recurrence. The mean Musculoskeletal Tumour Society score was 58% (33 to 77). Deep infection occurred in two patients, problems with wound healing in five and dislocation in one. For patients with a primary malignant peri-acetabular sarcoma involving the sacroiliac joint, we believe that this new prosthesis is a viable option for reconstruction of the bony defect left following resection of the tumour. It results in a satisfactory functional outcome with an acceptable rate of complications. . Cite this article: Bone Joint J 2014;96-B:399–405


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 186 - 188
1 Mar 1989
Chen S Badrinath K Pell L Mitchell K

We aimed to find out whether the Hastings bipolar prosthesis moved in a bipolar fashion after its use for displaced fractures of the femoral neck. In 65 patients non-weight-bearing movement was assessed radiographically and compared with an earlier study of the Monk prosthesis. In 70% of patients, the only movement was between the acetabulum and the prosthetic shell, the prosthesis behaving as if it were unipolar. This did not change with time, but there was a slight improvement in the range of movement, particularly in flexion. The absence of movement between the outer shell and the metal head is most probably due to the design of the prosthesis and makes this prosthesis unsuitable for use in osteoarthritic hips


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 391 - 394
1 May 1996
Calder SJ Anderson GH Jagger C Harper WM Gregg PJ

We performed a randomised prospective trial to compare a cemented unipolar prosthesis (Thompson) with a cemented bipolar prosthesis (Monk) in the treatment of displaced intracapsular fractures of the hip in patients over 80 years of age. Patients with a mental test score of less than 5/13 were excluded but the mortality was still about 30% at one year in both groups. We therefore feel that subjective criteria such as the level of pain and the return to the preinjury state are of paramount importance. Two years after operation there was no statistical difference between the rate of complications in the two groups. After adjusting for confounding factors such as differences in the level of function before injury between the groups, the degree of return to the preinjury state was significantly greater (p = 0.04) when using the unipolar prosthesis, which is one-quarter of the price of the bipolar. We cannot therefore justify the use of an expensive bipolar prosthesis in patients over 80 years of age


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 450 - 453
1 Nov 1980
Loudon Charnley J

A method is described of measuring radiological subsidence of a femoral prosthesis in relation to the femur after total hip arthroplasty. The method depends on measuring the distance from the tip of the femoral prosthesis to a fixed point in the bone. Subsidence after the use of a conventional design of femoral stem is compared with that after the use of a stem with a dorsal flange (Cobra). A significant reduction in the incidence and amount of subsidence was found when using the dorsal flange. There was also a notable absence of transverse fractures involving the cement near the tip of the stem, which occurred in 26 per cent of the cases using a conventional prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 85 - 91
1 Jan 1996
Önsten I Carlsson ÅS Sanzén L Besjakov J

A consecutive series of 30 total hip replacements using a hydroxyapatite (HA)-coated, modular implant (Omnifit) was followed clinically and by roentgen stereophotogrammetric analysis for two years and compared with two control groups, one of 27 cemented Charnley sockets and one of 40 cemented Charnley stems. Omnifit sockets with a central gap between the dome of the socket and the acetabular bone in the postoperative radiographs, migrated less than sockets without such gaps (p = 0.01). After adjustment for patient-related factors (age, gender and weight), no significant difference was found between the two prostheses with respect to micromotion and wear. We conclude that the early fixation of the HA-coated Omnifit prosthesis compares with that of the cemented Charnley prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 737 - 741
1 Nov 1984
Rydholm U Tjornstrand B Pettersson H Lidgren L

Fifteen patients with rheumatoid arthritis had 19 elbow arthroplasties with the Wadsworth type of surface replacement prosthesis. After a follow-up period averaging 30 months, 11 patients with 15 elbow arthroplasties were entirely satisfied with their freedom from pain and range of movement. Radiologically, however, the humeral component was loose in 10 of the 19 elbows and the ulnar component in 5. Two patients had reoperation, one to remove a prosthesis for early deep infection and one to exchange a humeral component which was loose. The risk of mechanical loosening is reduced by accurate positioning of the humeral component, but there is a high potential for failure. Changes in the design of the prosthesis and better instrumentation for alignment of the components are desirable. Prosthetic replacement of the elbow should still be regarded as experimental


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1656 - 1658
1 Dec 2006
Hatano H Morita T Kobayashi H Otsuka H

Despite extensive experience with prosthetic replacement for the reconstruction of limbs following juxta-articular resection of tumours, there are few reports of prosthetic replacement of the distal radius. We present two cases of massive bone defects of the distal radius in which alumina ceramic prosthetic replacements were used. We evaluated the patients more than ten years after the procedure. Both patients had degenerative changes to the wrist. This, however, was not associated with pain or decreased function, and both had returned to their previous occupation after surgery. When a patient has a massive defect of the distal radius, reconstruction using a ceramic prosthesis is a reasonable alternative to using autograft. This method of treatment results in little pain, a moderate range of movement and satisfactory function


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1299 - 1302
1 Oct 2006
Tillman R Kalra S Grimer R Carter S Abudu A

Peri- and sub-prosthetic fractures, or pathological fractures below an existing well-fixed femoral component, with or without an ipsilateral knee replacement, present a difficult surgical challenge. We describe a simple solution, in which a custom-made prosthesis with a cylindrical design is cemented proximally to the stem of an existing, well-fixed femoral component. This effectively treats the fracture without sacrificing the good hip. We describe five patients with a mean age of 73 years (60 to 81) and a mean follow-up of 47 months (6 to 108). The mean overlap of the prosthesis over the femoral component was 7.5 cm (5.5 to 10). There have been no mechanical failures, no new infections and no re-operations. We suggest that in highly selected cases, in which conventional fixation is not feasible, this technique offers a durable option and avoids the morbidity of a total femoral replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 3 | Pages 411 - 417
1 Aug 1954
Cregan JCF

1. Sixty-five cases of medial fracture of the femoral neck treated by substitution of the head by an acrylic prosthesis have been studied. 2. In general, the long-term clinical results of prosthetic arthroplasty after fresh fractures have been disappointing. The method has given slightly better results in the treatment of old fractures. 3. In view of the almost perfect results obtained after successful Smith-Petersen nailing in the presence of an adequate blood supply to the femoral head, it seems unjustifiable to abandon this principle for immediate substitution with an acrylic femoral head. Nevertheless it is believed that an arthroplasty of this type is justified in fractures seen late, and in fresh subcapital fractures when the fracture is irreducible. If a prosthesis is to be used, more protection for the stump of the neck against the strain of weight bearing is essential; a simple head prosthesis is inadequate, and a head with either a neck extension or an intramedullary prolongation may give better results


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 1014 - 1022
1 Nov 1990
Nieder E Elson R Engelbrecht E Kasselt M Keller A Steinbrink K

We report the 12 to 74 month results of our mark I saddle prosthesis after its use as a salvage device for gross loss of pelvic bone stock in 76 patients with failed hip arthroplasties. The implant transmits load between iliac bone and bare polish chrome-cobalt. Our clinical and radiological results indicate that a useful and stable articulation can be achieved in most cases, provided that continued deep infection can be avoided. The appearance of radiological sclerosis at the bearing site in successful cases seems to indicate that significant late migration will not occur. Based on our experience with the mark I prosthesis we have designed and developed a mark II model which has freedom of axial rotation of the saddle. Our early results in 40 cases show a significant improvement over the results which could have been predicted for the mark I device