Advertisement for orthosearch.org.uk
Results 21 - 40 of 61
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1542 - 1548
2 Nov 2020
Stirling PHC Oliver WM Ling Tan H Brown IDM Oliver CW McQueen MM Molyneux SG Duckworth AD

Aims

The primary aim of this study was to describe patient satisfaction and health-related quality of life (HRQoL) following corrective osteotomy for a symptomatic malunion of the distal radius.

Methods

We retrospectively identified 122 adult patients from a single centre over an eight-year period who had undergone corrective osteotomy for a symptomatic malunion of the distal radius. The primary long-term outcome was the Patient-Rated Wrist Evaluation (PRWE) score. Secondary outcomes included the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, the EQ-5D-5L score, complications, and the Net Promoter Score (NPS). Multivariate regression analysis was used to determine factors associated with the PRWE score.


Aims

To assess the proportion of patients with distal radius fractures (DRFs) who were managed nonoperatively during the COVID-19 pandemic in accordance with the British Orthopaedic Association BOAST COVID-19 guidelines, who would have otherwise been considered for an operative intervention.

Methods

We retrospectively reviewed the radiographs and clinical notes of all patients with DRFs managed nonoperatively, following the publication of the BOAST COVID-19 guidelines on the management of urgent trauma between 26 March and 18 May 2020. Radiological parameters including radial height, radial inclination, intra-articular step-off, and volar tilt from post-reduction or post-application of cast radiographs were measured. The assumption was that if one radiological parameter exceeds the acceptable criteria, the patient would have been considered for an operative intervention in pre-COVID times.


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1082 - 1087
1 Aug 2020
Yiğit Ş Arslan H Akar MS Şahin MA

Aims

Osteopetrosis (OP) is a rare hereditary disease that causes reduced bone resorption and increased bone density as a result of osteoclastic function defect. Our aim is to review the difficulties, mid-term follow-up results, and literature encountered during the treatment of OP.

Methods

This is a retrospective and observational study containing data from nine patients with a mean age of 14.1 years (9 to 25; three female, six male) with OP who were treated in our hospital between April 2008 and October 2018 with 20 surgical procedures due to 17 different fractures. Patient data included age, sex, operating time, length of stay, genetic type of the disease, previous surgery, fractures, complications, and comorbidity.


Bone & Joint Research
Vol. 8, Issue 7 | Pages 313 - 322
1 Jul 2019
Law GW Wong YR Yew AK Choh ACT Koh JSB Howe TS

Objectives

The paradoxical migration of the femoral neck element (FNE) superomedially against gravity, with respect to the intramedullary component of the cephalomedullary device, is a poorly understood phenomenon increasingly seen in the management of pertrochanteric hip fractures with the intramedullary nail. The aim of this study was to investigate the role of bidirectional loading on the medial migration phenomenon, based on unique wear patterns seen on scanning electron microscopy of retrieved implants suggestive of FNE toggling.

Methods

A total of 18 synthetic femurs (Sawbones, Vashon Island, Washington) with comminuted pertrochanteric fractures were divided into three groups (n = 6 per group). Fracture fixation was performed using the Proximal Femoral Nail Antirotation (PFNA) implant (Synthes, Oberdorf, Switzerland; n = 6). Group 1 was subjected to unidirectional compression loading (600 N), with an elastomer (70A durometer) replacing loose fracture fragments to simulate surrounding soft-tissue tensioning. Group 2 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading), also with the elastomer replacing loose fracture fragments. Group 3 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading) without the elastomer. All constructs were tested at 2 Hz for 5000 cycles or until cut-out occurred. The medial migration distance (MMD) was recorded at the end of the testing cycles.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 530 - 538
1 Apr 2020
Rollick NC Gadinsky NE Klinger CE Kubik JF Dyke JP Helfet DL Wellman DS

Aims

Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity.

Methods

A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature.


Bone & Joint 360
Vol. 8, Issue 2 | Pages 33 - 35
1 Apr 2019


Bone & Joint 360
Vol. 7, Issue 6 | Pages 31 - 33
1 Dec 2018


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 973 - 983
1 Jul 2018
Schmal H Froberg L S. Larsen M Südkamp NP Pohlemann T Aghayev E Goodwin Burri K

Aims

The best method of treating unstable pelvic fractures that involve the obturator ring is still a matter for debate. This study compared three methods of treatment: nonoperative, isolated posterior fixation and combined anteroposterior stabilization.

Patients and Methods

The study used data from the German Pelvic Trauma Registry and compared patients undergoing conservative management (n = 2394), surgical treatment (n = 1345) and transpubic surgery, including posterior stabilization (n = 730) with isolated posterior osteosynthesis (n = 405) in non-complex Type B and C fractures that only involved the obturator ring anteriorly. Calculated odds ratios were adjusted for potential confounders. Outcome criteria were intraoperative and general short-term complications, the incidence of nerve injuries, and mortality.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1121 - 1122
1 Sep 2017
Haddad FS


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1232 - 1236
1 Sep 2017
Dahill M McArthur J Roberts GL Acharya MR Ward AJ Chesser TJS

Aims

The anterior pelvic internal fixator is increasingly used for the treatment of unstable, or displaced, injuries of the anterior pelvic ring. The evidence for its use, however, is limited. The aim of this paper is to describe the indications for its use, how it is applied and its complications.

Patients and Methods

We reviewed the case notes and radiographs of 50 patients treated with an anterior pelvic internal fixator between April 2010 and December 2015 at a major trauma centre in the United Kingdom. The median follow-up time was 38 months (interquartile range 24 to 51).


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 109 - 118
1 Jan 2018
Talbot C Davis N Majid I Young M Bouamra O Lecky FE Jones S

Aims

The aim of this study was to describe the epidemiology of closed isolated fractures of the femoral shaft in children, and to compare the treatment and length of stay (LOS) between major trauma centres (MTCs) and trauma units (TUs) in England.

Patients and Methods

National data were obtained from the Trauma and Audit Research Network for all isolated, closed fractures of the femoral shaft in children from birth to 15 years of age, between 2012 and 2015. Age, gender, the season in which the fracture occurred, non-accidental injury, the mechanism of injury, hospital trauma status, LOS and type of treatment were recorded.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 298 - 300
1 Mar 2016
Fullilove S Gozzard C

The results of the DRAFFT (distal radius acute fracture fixation trial) study, which compared volar plating with Kirschner (K-) wire fixation for dorsally displaced fractures of the distal radius, were published in August 2014. The use of K-wires to treat these fractures is now increasing, with a concomitant decline in the use of volar locking plates.

We provide a critical appraisal of the DRAFFT study and question whether surgeons have been unduly influenced by its headline conclusions.

Cite this article: Bone Joint J 2016;98-B:298–300.


Bone & Joint Research
Vol. 5, Issue 10 | Pages 490 - 491
1 Oct 2016
Ghert M McKee M


Bone & Joint 360
Vol. 5, Issue 5 | Pages 2 - 7
1 Oct 2016
Forward DP Ollivere BJ Ng JWG Coughlin TA Rollins KE

Rib fracture fixation by orthopaedic and cardiothoracic surgeons has become increasingly popular for the treatment of chest injuries in trauma. The literature, though mainly limited to Level II and III evidence, shows favourable results for operative fixation. In this paper we review the literature and discuss the indications for rib fracture fixation, surgical approaches, choice of implants and the future direction for management. With the advent of NICE guidance and new British Orthopaedic Association Standards for Trauma (BOAST) guidelines in production, the management of rib fractures is going to become more and more commonplace.


Bone & Joint 360
Vol. 2, Issue 5 | Pages 32 - 34
1 Oct 2013

The October 2013 Trauma Roundup360 looks at: Radiological, electromagnetic or just leave it out altogether?: distal locking in intramedullary nailing; Internal fixation of radiation-induced pathological fractures of the femur has a high rate of failure; Obesity and trauma; Short and sweet?: antibiotics in open fractures; Extremity injuries more important than previously thought?; Cement nails tiptop for osteomyelitis; Oxygen measurements for compartment syndrome?


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 814 - 817
1 Jun 2015
Bose D Kugan R Stubbs D McNally M

Infected nonunion of a long bone continues to present difficulties in management. In addition to treating the infection, it is necessary to establish bony stability, encourage fracture union and reconstruct the soft-tissue envelope.

We present a series of 67 infected nonunions of a long bone in 66 patients treated in a multidisciplinary unit. The operative treatment of patients suitable for limb salvage was performed as a single procedure. Antibiotic regimes were determined by the results of microbiological culture.

At a mean follow-up of 52 months (22 to 97), 59 patients (88%) had an infection-free united fracture in a functioning limb. Seven others required amputation (three as primary treatment, three after late failure of limb salvage and one for recalcitrant pain after union).

The initial operation achieved union in 54 (84%) of the salvaged limbs at a mean of nine months (three to 26), with recurrence of infection in 9%. Further surgery in those limbs that remained ununited increased the union rate to 62 (97%) of the 64 limbs treated by limb salvage at final follow-up. The use of internal fixation was associated with a higher risk of recurrent infection than external fixation.

Cite this article: Bone Joint J 2015; 97-B:814–17.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1632 - 1637
1 Dec 2011
Robinson CM Stone OD Murray IR

We identified 16 patients with a mean age of 56.5 years (31 to 86) from a large consecutive series of patients with proximal humeral fractures over a 15-year period, who had sustained a fracture with skin compromise after a blunt injury. The study group represented 0.2% of 7825 proximal humeral fractures treated during this period and all had a displaced Neer two-part fracture pattern. Two patterns of skin injury were identified: in ten patients there was skin penetration at the time of the original injury, and the other six patients initially had closed injuries. These six patients had fracture fragments penetrating the muscular envelope to lie subcutaneously producing either early skin tethering (two patients) or delayed skin penetration and sinus formation (four patients). The pattern of injury to the soft-tissue envelope and the fracture pattern were similar for all injuries. Treatment of these injuries was determined by the initial severity of the soft-tissue injury and the medical status of the patient. We currently favour open reduction and internal fixation of these fractures wherever possible, owing to the high rate of nonunion with non-operative management.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 558 - 563
1 Apr 2015
Windolf M Fischer MF Popp AW Matthys R Schwieger K Gueorguiev B Hunter JB Slongo TF

End caps are intended to prevent nail migration (push-out) in elastic stable intramedullary nailing. The aim of this study was to investigate the force at failure with and without end caps, and whether different insertion angles of nails and end caps would alter that force at failure.

Simulated oblique fractures of the diaphysis were created in 15 artificial paediatric femurs. Titanium Elastic Nails with end caps were inserted at angles of 45°, 55° and 65° in five specimens for each angle to create three study groups. Biomechanical testing was performed with axial compression until failure. An identical fracture was created in four small adult cadaveric femurs harvested from two donors (both female, aged 81 and 85 years, height 149 cm and 156 cm, respectively). All femurs were tested without and subsequently with end caps inserted at 45°.

In the artificial femurs, maximum force was not significantly different between the three groups (p = 0.613). Push-out force was significantly higher in the cadaveric specimens with the use of end caps by an up to sixfold load increase (830 N, standard deviation (SD) 280 vs 150 N, SD 120, respectively; p = 0.007).

These results indicate that the nail and end cap insertion angle can be varied within 20° without altering construct stability and that the risk of elastic stable intramedullary nailing push–out can be effectively reduced by the use of end caps.

Cite this article: Bone Joint J 2015;97-B:558–63.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 22 - 24
1 Feb 2015

The February 2015 Shoulder & Elbow Roundup360 looks at: Proximal Humerus fractures a comprehensive review, Predicting complications in shoulder ORIF, The Coronoid Revisited, Remplissage and bankart repair for Hill-Sach’s lesions, Diabetes and elbow arthroplasty, Salvage surgery for failed bankart repair, Sternoclavicular Joint Reconstruction, Steroids effective in the short-term for tennis elbow


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 237 - 244
1 Feb 2011
Berber O Amis AA Day AC

The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°.

The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1° of rotation around the mediolateral axis at a load of 500 N.