The April 2013 Spine Roundup360 looks at: smuggling spinal implants; local bone graft and PLIF; predicting disability with slipped discs; mortality and spinal surgery; spondyloarthropathy; brachytherapy; and fibrin mesh and BMP.
Immunosuppression following intra-articular injections of steroid into the hip may interfere with asepsis in a subsequent total hip arthroplasty (THA). We have undertaken a retrospective, matched, cohort study of infective complications after THA, in 40 patients who had received such an injection and 40 who had not. In the injection group there were five revisions, four of which were for deep infection. There were none in the matched group. The overall rate of revision in our database of 979 primary THAs was 1.02%. Six additional patients who had received injections underwent investigation for infection because of persistent problems in the hip as compared with one in the control group.
Most problems encountered in complex revision
total knee arthroplasty can be managed with the wide range of implant
systems currently available. Modular metaphyseal sleeves, metallic
augments and cones provide stability even with significant bone
loss. Hinged designs substitute for significant ligamentous deficiencies.
Catastrophic failure that precludes successful reconstruction can
be encountered. The alternatives to arthroplasty in such drastic
situations include knee arthrodesis, resection arthroplasty and
amputation. The relative indications for the selection of these
alternatives are recurrent deep infection, immunocompromised host,
and extensive non-reconstructible bone or soft-tissue defects.
Antibiotic impregnated articulating spacers are
used in two-stage revision total knee arthroplasty to deliver local antibiotic
therapy while preserving function. We have observed infection control
in greater than 95% of cases with functional outcomes approaching
those seen in revision for aseptic loosening. Higher failure has
been observed with methicillin resistant organisms.
PCL retaining fixed-bearing TKA is a highly successful
operation with the need for more surgery occurring at the rate of
approximately 0.4% per year over the first 27 years. The most common
cause for revision surgery is related to polyethylene insert failure
and accounts for approximately 50% of re-operations. Late metastatic
infection is the next most frequent cause followed by patellar problems,
late instability and component loosening in decreasing frequency.
A myriad of rare miscellaneous problems can also occur.
The practice of removing a well-fixed cementless
femoral component is associated with high morbidity. Ceramic bearing
couples are low wearing and their use minimises the risk of subsequent
further revision due to the production of wear debris. A total of
165 revision hip replacements were performed, in which a polyethylene-lined acetabular
component was revised to a new acetabular component with a ceramic
liner, while retaining the well-fixed femoral component. A titanium
sleeve was placed over the used femoral trunnion, to which a ceramic
head was added. There were 100 alumina and 65 Delta bearing couples
inserted. The mean Harris hip score improved significantly from 71.3 (9.0
to 100.0) pre-operatively to 91.0 (41.0 to 100.0) at a mean follow
up of 4.8 years (2.1 to 12.5) (p <
0.001). No patients reported
squeaking of the hip. There were two fractures of the ceramic head, both in alumina
bearings. No liners were seen to fracture. No fractures were observed
in components made of Delta ceramic. At 8.3Â years post-operatively
the survival with any cause of failure as the endpoint was 96.6%
(95% confidence interval (CI) 85.7 to 99.3) for the acetabular component and
94.0% (95% CI 82.1 to 98.4) for the femoral component. The technique of revising the acetabular component in the presence
of a well-fixed femoral component with a ceramic head placed on
a titanium sleeve over the used trunnion is a useful adjunct in
revision hip practice. The use of Delta ceramic is recommended. Cite this article:
Achieving arthrodesis of the ankle can be difficult
in the presence of infection, deformity, poor soft tissues and bone loss.
We present a series of 48 patients with complex ankle pathology,
treated with the Ilizarov technique. Infection was present in 30
patients and 30Â had significant deformity before surgery. Outcome
was assessed clinically and with patient-reported outcome measures
(Modified American Orthopaedic Foot and Ankle Society (MAOFAS) scale and
the Short-Form (SF-36)). Arthrodesis was achieved in 40 patients with the Ilizarov technique
alone and in six further patients with additional surgery. Infection
was eradicated in all patients at a mean follow-up of 46.6 months
(13 to 162). Successful arthrodesis was less likely in those with
comorbidities and in tibiocalcaneal fusion compared with tibiotalar
fusion. These patients had poor general health scores compared with the
normal population before surgery. The mean MAOFAS score improved
significantly from 24.3 (0 to 90) pre-operatively to 56.2 (30 to
90) post-operatively, but there was only a modest improvement in
general health; the mean SF-36 improved from 44.8 (19 to 66) to
50.1 (21 to 76). There was a major benefit in terms of pain relief. Arthrodesis using the Ilizarov technique is an effective treatment
for complex ankle pathology, with good clinical outcomes and eradication
of infection. However, even after successful arthrodesis general
health scores remain limited. Cite this article:
An eight-week-old boy developed severe thoracic
spondylodiscitis following pneumonia and septicaemia. A delay in
diagnosis resulted in complete destruction of the T4 and T5 vertebral
bodies and adjacent discs, with a paraspinal abscess extending into
the mediastinum and epidural space. Antibiotic treatment controlled
the infection and the abscess was aspirated. At the age of six months,
he underwent posterior spinal fusion Spondylodiscitis should be included in the differential diagnosis
of infants who present with severe illness and atypical symptoms.
Delayed diagnosis can result in major spinal complications with
a potentially fatal outcome.
The December 2012 Trauma Roundup360 looks at: whether tranexamic acid stops bleeding in trauma across the board; antibiotic beads and VAC; whether anaesthetic determines the outcome in surgery for distal radial fractures; high complications in surgery on bisphosphonate-hardened bone; better outcomes but more dislocations in femoral neck fractures; the mythical hip fracture; plate augmentation in nonunion surgery; and SIGN intramedullary nailing and infections.
Disruption of the extensor mechanism in total
knee arthroplasty may occur by tubercle avulsion, patellar or quadriceps
tendon rupture, or patella fracture, and whether occurring intra-operatively
or post-operatively can be difficult to manage and is associated
with a significant rate of failure and associated complications.
This surgery is frequently performed in compromised tissues, and
repairs must frequently be protected with cerclage wiring and/or
augmentation with local tendon (semi-tendinosis, gracilis) which
may also be used to treat soft-tissue loss in the face of chronic
disruption. Quadriceps rupture may be treated with conservative
therapy if the patient retains active extension. Component loosening
or loss of active extension of 20° or greater are clear indications
for surgical treatment of patellar fracture. Acute patellar tendon
disruption may be treated by primary repair. Chronic extensor failure
is often complicated by tissue loss and retraction can be treated
with medial gastrocnemius flaps, achilles tendon allografts, and
complete extensor mechanism allografts. Attention to fixing the
graft in full extension is mandatory to prevent severe extensor
lag as the graft stretches out over time.
Since 1996 more than one million metal-on-metal
articulations have been implanted worldwide. Adverse reactions to
metal debris are escalating. Here we present an algorithmic approach
to patient management. The general approach to all arthroplasty
patients returning for follow-up begins with a detailed history,
querying for pain, discomfort or compromise of function. Symptomatic
patients should be evaluated for intra-articular and extra-articular
causes of pain. In large head MoM arthroplasty, aseptic loosening
may be the source of pain and is frequently difficult to diagnose.
Sepsis should be ruled out as a source of pain. Plain radiographs
are evaluated to rule out loosening and osteolysis, and assess component
position. Laboratory evaluation commences with erythrocyte sedimentation
rate and C-reactive protein, which may be elevated. Serum metal
ions should be assessed by an approved facility. Aspiration, with
manual cell count and culture/sensitivity should be performed, with
cloudy to creamy fluid with predominance of monocytes often indicative
of failure. Imaging should include ultrasound or metal artifact
reduction sequence MRI, specifically evaluating for fluid collections
and/or masses about the hip. If adverse reaction to metal debris
is suspected then revision to metal or ceramic-on-polyethylene is indicated
and can be successful. Delay may be associated with extensive soft-tissue
damage and hence poor clinical outcome.
We undertook a retrospective review of 33 patients who underwent total femoral endoprosthetic replacement as limb salvage following excision of a malignant bone tumour. In 22 patients this was performed as a primary procedure following total femoral resection for malignant disease. Revision to a total femoral replacement was required in 11 patients following failed segmental endoprosthetic or allograft reconstruction. There were 33 patients with primary malignant tumours, and three had metastatic lesions. The mean age of the patients was 31 years (5 to 68). The mean follow-up was 4.2 years (9 months to 16.4 years). At five years the survival of the implants was 100%, with removal as the endpoint and 56% where the endpoint was another surgical intervention. At five years the patient survival was 32%. Complications included dislocation of the hip in six patients (18%), local recurrence in three (9%), peri-prosthetic fracture in two and infection in one. One patient subsequently developed pulmonary metastases. There were no cases of aseptic loosening or amputation. Four patients required a change of bushings. The mean Musculoskeletal Tumour Society functional outcome score was 67%, the mean Harris Hip Score was 70, and the mean Oxford Knee Score was 34. Total femoral endoprosthetic replacement can provide good functional outcome without compromising patient survival, and in selected cases provides an effective alternative to amputation.
We report on two cases of infective spondylodiscitis
caused by We describe the clinical features, investigations and treatment
options.
Compartment pressures have not previously been studied in healthy children. We compared the pressures in the four lower leg compartments of healthy children with those of healthy adults. We included patients aged between two months and six years, and measured the pressures in 80 compartments of 20 healthy children using simple needle manometry. Measurements were repeated in a control group of 20 healthy adults. The mean compartment pressure in the lower leg in children was significantly higher than in adults (p <
0.001). On average, pressures in the four compartments varied between 13.3 mmHg and 16.6 mmHg in the children and between 5.2 mmHg and 9.7 mmHg in the adults. The latter is in accordance with those recorded in the literature. The mean arterial pressure did not relate to age or to pressure in the compartment. The findings of this study that the normal compartment pressure of the lower leg in healthy children is significantly higher than that in adults may be of considerable significance in clinical decision-making in children of this age.
In this paper, we consider wound healing after
total knee arthroplasty.
Between 1986 and 1991 we implanted 331 consecutive Furlong hydroxyapatite-coated femoral components of a total hip replacement in 291 patients. A cemented acetabular prosthesis was used in 217 hips and a hydroxyapatite-coated component in 114. We describe the long-term clinical and radiological survival of the femoral component at a mean follow-up of 17.5 years (15 to 21). Only two patients (0.68%) were lost to follow-up. With revision of the femoral component for any reason as the endpoint, the survival at a mean of 17 years was 97.4% (95% confidence interval 94.1 to 99.5), and with revision for aseptic loosening as the endpoint it was 100%. The survival at a maximum of 21 years with revision of the femoral component for any reason as the endpoint was 97.4% (95% confidence interval 81.0 or 99.5). These results compare favourably with the best long-term results of cemented or uncemented femoral components used in total hip replacement.
Fracture of a ceramic component in total hip
replacement is a rare but potentially catastrophic complication.
The incidence is likely to increase as the use of ceramics becomes
more widespread. We describe such a case, which illustrates how
inadequate initial management will lead to further morbidity and
require additional surgery. We present the case as a warning that
fracture of a ceramic component should be revised to another ceramic-on-ceramic
articulation in order to minimise the risk of further catastrophic
wear.
Seven stiff total knee arthroplasties are presented
to illustrate the roles of: 1) manipulation under general anesthesia;
2) multiple concurrent diagnoses in addition to stiffness; 3) extra-articular
pathology; 4) pain as part of the stiffness triad (pain and limits
to flexion or extension); 5) component internal rotation; 6) multifactorial
etiology; and 7) surgical exposure in this challenging clinical
problem.
Local corticosteroid infiltration is a common practice of treatment
for lateral epicondylitis. In recent studies no statistically significant
or clinically relevant results in favour of corticosteroid injections
were found. The injection of autologous blood has been reported
to be effective for both intermediate and long-term outcomes. It
is hypothesised that blood contains growth factors, which induce
the healing cascade. A total of 60 patients were included in this prospective randomised
study: 30 patients received 2 ml autologous blood drawn from contralateral
upper limb vein + 1 ml 0.5% bupivacaine, and 30 patients received
2 ml local corticosteroid + 1 ml 0.5% bupivacaine at the lateral
epicondyle. Outcome was measured using a pain score and Nirschl
staging of lateral epicondylitis. Follow-up was continued for total
of six months, with assessment at one week, four weeks, 12 weeks
and six months.Objectives
Methods
We examined 204 children (137 boys and 67 girls) aged 12 years and under with septic arthritis. Their mean age was 31.1 months (1 to 144; SD 41.6). The most common joints affected were the knees and shoulders. Joints in the upper limb were affected more often in younger children and in the lower limb in those who were older. The mean age for an infection was 12 months in the shoulder and 73 months in the hip. The most common organisms cultured were species of Salmonella.