Advertisement for orthosearch.org.uk
Results 321 - 340 of 478
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1635 - 1641
1 Dec 2016
Arverud ED Anundsson P Hardell E Barreng G Edman G Latifi A Labruto F Ackermann PW

Aims

Patients with an acute Achilles tendon rupture (ATR) take a long time to heal, have a high incidence of deep vein thrombosis (DVT) and widely variable functional outcomes. This variation in outcome may be explained by a lack of knowledge of adverse factors, and a subsequent shortage of appropriate interventions.

Patients and Methods

A total of 111 patients (95 men, 16 women; mean age 40.3, standard deviation 8.4) with an acute total ATR were prospectively assessed. At one year post-operatively a uniform outcome score, Achilles Combined Outcome Score (ACOS), was obtained by combining three validated, independent, outcome measures: Achilles tendon Total Rupture Score, heel-rise height test, and limb symmetry heel-rise height. Predictors of ACOS included treatment; gender; age; smoking; body mass index; time to surgery; physical activity level pre- and post-injury; symptoms; quality of life and incidence of DVT.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1435 - 1440
1 Oct 2015
Heidt C Hollander K Wawrzuta J Molesworth C Willoughby K Thomason P Khot A Graham HK

Pelvic obliquity is a common finding in adolescents with cerebral palsy, however, there is little agreement on its measurement or relationship with hip development at different gross motor function classification system (GMFCS) levels.

The purpose of this investigation was to study these issues in a large, population-based cohort of adolescents with cerebral palsy at transition into adult services.

The cohort were a subset of a three year birth cohort (n = 98, 65M: 33F, with a mean age of 18.8 years (14.8 to 23.63) at their last radiological review) with the common features of a migration percentage greater than 30% and a history of adductor release surgery.

Different radiological methods of measuring pelvic obliquity were investigated in 40 patients and the angle between the acetabular tear drops (ITDL) and the horizontal reference frame of the radiograph was found to be reliable, with good face validity. This was selected for further study in all 98 patients.

The median pelvic obliquity was 4° (interquartile range 2° to 8°). There was a strong correlation between hip morphology and the presence of pelvic obliquity (effect of ITDL on Sharpe’s angle in the higher hip; rho 7.20 (5% confidence interval 5.59 to 8.81, p < 0.001). This was particularly true in non-ambulant adolescents (GMFCS IV and V) with severe pelvic obliquity, but was also easily detectable and clinically relevant in ambulant adolescents with mild pelvic obliquity.

The identification of pelvic obliquity and its management deserves closer scrutiny in children and adolescents with cerebral palsy.

Cite this article: Bone Joint J 2015;97-B:1435–40.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1070 - 1075
1 Aug 2015
Murphy MT Vardi R Journeaux SF Whitehouse SL

If patients could recall their physical status before total hip (THA) or knee arthroplasty (TKA) accurately it could have valuable applications both clinically and for research. This study evaluated the accuracy of a patient’s recollection one year after either THA or TKA using the Oxford hip or knee scores (OHS and OKS). In total, 113 patients (59 THA, 54 TKA) who had completed the appropriate score pre-operatively were asked to complete the score again at a mean of 12.4 months (standard deviation (sd) 0.8) after surgery, recalling their pre-operative state.

While there were no significant differences between the actual and recalled pre-operative scores (OHS mean difference 0.8, sd 6.21, 95% confidence interval (CI) -0.82 to 2.42, p = 0.329; OKS mean difference -0.11, sd 7.34, 95% CI -2.11 to 1.89, p = 0.912), absolute differences were relatively large (OHS, 5.24; OKS, 5.41), correlation was weak (OHS r = 0.7, OKS r = 0.61) and agreement between actual and recalled responses for individual questions was poor in half of the OHS and two thirds of the OKS.

A patient’s recollection of pre-operative pain and function is inaccurate one year after THA or TKA.

Cite this article: Bone Joint J 2015;97-B:1070–5.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1234 - 1239
1 Sep 2016
Yu HM Malhotra K Butler JS Patel A Sewell MD Li YZ Molloy S

Aims

Patients with multiple myeloma (MM) develop deposits in the spine which may lead to vertebral compression fractures (VCFs). Our aim was to establish which spinopelvic parameters are associated with the greatest disability in patients with spinal myeloma and VCFs.

Patients and Methods

We performed a retrospective cross-sectional review of 148 consecutive patients (87 male, 61 female) with spinal myeloma and analysed correlations between spinopelvic parameters and patient-reported outcome scores. The mean age of the patients was 65.5 years (37 to 91) and the mean number of vertebrae involved was 3.7 (1 to 15).


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1099 - 1105
1 Aug 2016
Weiser L Dreimann M Huber G Sellenschloh K Püschel K Morlock MM Rueger JM Lehmann W

Aims

Loosening of pedicle screws is a major complication of posterior spinal stabilisation, especially in the osteoporotic spine. Our aim was to evaluate the effect of cement augmentation compared with extended dorsal instrumentation on the stability of posterior spinal fixation.

Materials and Methods

A total of 12 osteoporotic human cadaveric spines (T11-L3) were randomised by bone mineral density into two groups and instrumented with pedicle screws: group I (SHORT) separated T12 or L2 and group II (EXTENDED) specimen consisting of T11/12 to L2/3. Screws were augmented with cement unilaterally in each vertebra. Fatigue testing was performed using a cranial-caudal sinusoidal, cyclic (1.0 Hz) load with stepwise increasing peak force.


Bone & Joint Research
Vol. 5, Issue 9 | Pages 362 - 369
1 Sep 2016
Oba M Inaba Y Kobayashi N Ike H Tezuka T Saito T

Objectives

In total hip arthroplasty (THA), the cementless, tapered-wedge stem design contributes to achieving initial stability and providing optimal load transfer in the proximal femur. However, loading conditions on the femur following THA are also influenced by femoral structure. Therefore, we determined the effects of tapered-wedge stems on the load distribution of the femur using subject-specific finite element models of femurs with various canal shapes.

Patients and Methods

We studied 20 femurs, including seven champagne flute-type femurs, five stovepipe-type femurs, and eight intermediate-type femurs, in patients who had undergone cementless THA using the Accolade TMZF stem at our institution. Subject–specific finite element (FE) models of pre- and post-operative femurs with stems were constructed and used to perform FE analyses (FEAs) to simulate single-leg stance. FEA predictions were compared with changes in bone mineral density (BMD) measured for each patient during the first post-operative year.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 689 - 695
1 May 2015
Basques BA Bohl DD Golinvaux NS Samuel AM Grauer JG

The aim of this study was to compare the operating time, length of stay (LOS), adverse events and rate of re-admission for elderly patients with a fracture of the hip treated using either general or spinal anaesthesia. Patients aged ≥ 70 years who underwent surgery for a fracture of the hip between 2010 and 2012 were identified from the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) database. Of the 9842 patients who met the inclusion criteria, 7253 (73.7%) were treated with general anaesthesia and 2589 (26.3%) with spinal anaesthesia. On propensity-adjusted multivariate analysis, general anaesthesia was associated with slightly increased operating time (+5 minutes, 95% confidence interval (CI) +4 to +6, p < 0.001) and post-operative time in the operating room (+5 minutes, 95% CI +2 to +8, p < 0.001) compared with spinal anaesthesia. General anaesthesia was associated with a shorter LOS (hazard ratio (HR) 1.28, 95% CI 1.22 to 1.34, p < 0.001). Any adverse event (odds ratio (OR) 1.21, 95% CI 1.10 to 1.32, p < 0.001), thromboembolic events (OR 1.90, 95% CI 1.24 to 2.89, p = 0.003), any minor adverse event (OR 1.19, 95% CI 1.09 to 1.32, p < 0.001), and blood transfusion (OR 1.34, 95% CI 1.22 to 1.49, p < 0.001) were associated with general anaesthesia. General anaesthesia was associated with decreased rates of urinary tract infection (OR 0.73, 95% CI 0.62 to 0.87, p < 0.001). There was no clear overall advantage of one type of anaesthesia over the other, and surgeons should be aware of the specific risks and benefits associated with each type.

Cite this article: Bone Joint J 2015; 97-B:689–95.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 793 - 801
1 Jun 2015
Liddle AD Pandit H Judge A Murray DW

Whether to use total or unicompartmental knee replacement (TKA/UKA) for end-stage knee osteoarthritis remains controversial. Although UKA results in a faster recovery, lower rates of morbidity and mortality and fewer complications, the long-term revision rate is substantially higher than that for TKA. The effect of each intervention on patient-reported outcome remains unclear. The aim of this study was to determine whether six-month patient-reported outcome measures (PROMs) are better in patients after TKA or UKA, using data from a large national joint registry (NJR).

We carried out a propensity score-matched cohort study which compared six-month PROMs after TKA and UKA in patients enrolled in the NJR for England and Wales, and the English national PROM collection programme. A total of 3519 UKA patients were matched to 10 557 TKAs.

The mean six-month PROMs favoured UKA: the Oxford Knee Score was 37.7 (95% confidence interval (CI) 37.4 to 38.0) for UKA and 36.1 (95% CI 35.9 to 36.3) for TKA; the mean EuroQol EQ-5D index was 0.772 (95% CI 0.764 to 0.780) for UKA and 0.751 (95% CI 0.747 to 0.756) for TKA. UKA patients were more likely to achieve excellent results (odds ratio (OR) 1.59, 95% CI 1.47 to 1.72, p < 0.001) and to be highly satisfied (OR 1.27, 95% CI 1.17 to 1.39, p <  0.001), and were less likely to report complications than those who had undergone TKA.

UKA gives better early patient-reported outcomes than TKA; these differences are most marked for the very best outcomes. Complications and readmission are more likely after TKA. Although the data presented reflect the short-term outcome, they suggest that the high revision rate for UKA may not be because of poorer clinical outcomes. These factors should inform decision-making in patients eligible for either procedure.

Cite this article: Bone Joint J 2015;97-B:793–801.


Bone & Joint Research
Vol. 5, Issue 8 | Pages 338 - 346
1 Aug 2016
MacLeod AR Sullivan NPT Whitehouse MR Gill HS

Objectives

Modular junctions are ubiquitous in contemporary hip arthroplasty. The head-trunnion junction is implicated in the failure of large diameter metal-on-metal (MoM) hips which are the currently the topic of one the largest legal actions in the history of orthopaedics (estimated costs are stated to exceed $4 billion). Several factors are known to influence the strength of these press-fit modular connections. However, the influence of different head sizes has not previously been investigated. The aim of the study was to establish whether the choice of head size influences the initial strength of the trunnion-head connection.

Materials and Methods

Ti-6Al-4V trunnions (n = 60) and two different sizes of cobalt-chromium (Co-Cr) heads (28 mm and 36 mm; 30 of each size) were used in the study. Three different levels of assembly force were considered: 4 kN; 5 kN; and 6 kN (n = 10 each). The strength of the press-fit connection was subsequently evaluated by measuring the pull-off force required to break the connection. The statistical differences in pull-off force were examined using a Kruskal–Wallis test and two-sample Mann–Whitney U test. Finite element and analytical models were developed to understand the reasons for the experimentally observed differences.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 339 - 342
1 Mar 2013
Milligan DJ O’Brien S Bennett D Hill JC Beverland DE

With greater numbers of younger patients undergoing total hip replacement (THR), the effect of patient age on the diameter of the femoral canal may become more relevant. This study aimed to investigate the relationship between the diameter of the diaphysis of the femoral canal with increasing age in a large number of patients who underwent THR. A total of 1685 patients scheduled for THR had their femoral dimensions recorded from calibrated radiographs. There were 736 males and 949 females with mean ages of 67.1 years (34 to 92) and 70.2 years (29 to 92), respectively. The mean diameter of the femoral canal was 13.3 mm (8.0 to 23.0) for males and 12.7 mm (6.0 to 26.0) for females. There was a poor correlation between age and the diameter of the canal in males (r = 0.071, p = 0.05) but a stronger correlation in females (r = 0.31, p < 0.001).

The diameter of the femoral canal diameter of a female patient undergoing THR could be predicted to increase by 3.2 mm between the ages of 40 and 80 years, in contrast a male would be expected to experience only a 0.6 mm increase during the same period. This increase in the diameter of the canal with age might affect the long-term survival of the femoral component in female patients.

Cite this article: Bone Joint J 2013;95-B:339–42.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 14 - 17
1 Dec 2013

The December 2013 Knee Roundup360 looks at: Conflict of interest and hyaluronic acid; Will time indeed tell in microfracture?; Contralateral knee pain and joint replacement outcomes; Patient satisfaction and knee replacement?; Hope in the cytokines for painful TKRs?; Pain severity, cytokines and osteoarthritis?; Quadriceps weakness and pain; and spontaneous osteonecrosis of the knee


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 100 - 105
1 Jan 2014
Shapiro F Zurakowski D Bui T Darras BT

We determined the frequency, rate and extent of development of scoliosis (coronal plane deformity) in wheelchair-dependent patients with Duchenne muscular dystrophy (DMD) who were not receiving steroid treatment. We also assessed kyphosis and lordosis (sagittal plane deformity). The extent of scoliosis was assessed on sitting anteroposterior (AP) spinal radiographs in 88 consecutive non-ambulatory patients with DMD. Radiographs were studied from the time the patients became wheelchair-dependent until the time of spinal fusion, or the latest assessment if surgery was not undertaken. Progression was estimated using a longitudinal mixed-model regression analysis to handle repeated measurements.

Scoliosis ≥ 10° occurred in 85 of 88 patients (97%), ≥ 20° in 78 of 88 (89%) and ≥ 30° in 66 of 88 patients (75%). The fitted longitudinal model revealed that time in a wheelchair was a highly significant predictor of the magnitude of the curve, independent of the age of the patient (p <  0.001). Scoliosis developed in virtually all DMD patients not receiving steroids once they became wheelchair-dependent, and the degree of deformity deteriorated over time.

In general, scoliosis increased at a constant rate, beginning at the time of wheelchair-dependency (p < 0.001). In some there was no scoliosis for as long as three years after dependency, but scoliosis then developed and increased at a constant rate. Some patients showed a rapid increase in the rate of progression of the curve after a few years – the clinical phenomenon of a rapidly collapsing curve over a few months.

A sagittal plane kyphotic deformity was seen in 37 of 60 patients (62%) with appropriate radiographs, with 23 (38%) showing lumbar lordosis (16 (27%) abnormal and seven (11%) normal).

This study provides a baseline to assess the effects of steroids and other forms of treatment on the natural history of scoliosis in patients with DMD, and an approach to assessing spinal deformity in the coronal and sagittal planes in wheelchair-dependent patients with other neuromuscular disorders.

Cite this article: Bone Joint J 2014;96-B:100–5.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 925 - 933
1 Jul 2016
Sidaginamale RP Joyce TJ Bowsher JG Lord JK Avery PJ Natu S Nargol AVF Langton DJ

Aims

We wished to investigate the influence of metal debris exposure on the subsequent immune response and resulting soft-tissue injury following metal-on-metal (MoM) hip arthroplasty. Some reports have suggested that debris generated from the head-neck taper junction is more destructive than equivalent doses from metal bearing surfaces.

Patients and Methods

We investigated the influence of the source and volume of metal debris on chromium (Cr) and cobalt (Co) concentrations in corresponding blood and hip synovial fluid samples and the observed agglomerated particle sizes in excised tissues using multiple regression analysis of prospectively collected data. A total of 199 explanted MoM hips (177 patients; 132 hips female) were analysed to determine rates of volumetric wear at the bearing surfaces and taper junctions.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 32 - 33
1 Feb 2016


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 326 - 333
1 Mar 2016
Morvan A Moreau S Combourieu B Pansard E Marmorat JL Carlier R Judet T Lonjon G

Aims

The primary aim of this study was to analyse the position of the acetabular and femoral components in total hip arthroplasty undertaken using an anterior surgical approach.

Patients and Methods

In a prospective, single centre study, we used the EOS imaging system to analyse the position of components following THA performed via the anterior approach in 102 patients (103 hips) with a mean age of 64.7 years (sd 12.6). Images were taken with patients in the standing position, allowing measurement of both anatomical and functional anteversion of the acetabular component.


Bone & Joint 360
Vol. 4, Issue 6 | Pages 28 - 29
1 Dec 2015

The December 2015 Research Roundup360 looks at: Biomarkers in periprosthetic joint infection; HbA1c and complications in arthroplasty; Getting to the bottom of biofilms; Effective antibiosis for biofilms; Stem cells and avascular necrosis; Predicting LOS in total joint arthroplasty; Long-term antibiotics reduce recurrence in periprosthetic infection


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1223 - 1231
1 Sep 2011
Babazadeh S Dowsey MM Swan JD Stoney JD Choong PFM

The role of computer-assisted surgery in maintaining the level of the joint in primary knee joint replacement (TKR) has not been well defined. We undertook a blinded randomised controlled trial comparing joint-line maintenance, functional outcomes, and quality-of-life outcomes between patients undergoing computer-assisted and conventional TKR. A total of 115 patients were randomised (computer-assisted, n = 55; conventional, n = 60).

Two years post-operatively no significant correlation was found between computer-assisted and conventional surgery in terms of maintaining the joint line. Those TKRs where the joint line was depressed post-operatively improved the least in terms of functional scores. No difference was detected in terms of quality-of-life outcomes. Change in joint line was found to be related to change in alignment. Change in alignment significantly affects change in joint line and functional scores.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1649 - 1656
1 Dec 2014
Lindberg-Larsen M Jørgensen CC Bæk Hansen T Solgaard S Odgaard A Kehlet H

We present detailed information about early morbidity after aseptic revision knee replacement from a nationwide study. All aseptic revision knee replacements undertaken between 1st October 2009 and 30th September 2011 were analysed using the Danish National Patient Registry with additional information from the Danish Knee Arthroplasty Registry. The 1218 revisions involving 1165 patients were subdivided into total revisions, large partial revisions, partial revisions and revisions of unicondylar replacements (UKR revisions). The mean age was 65.0 years (27 to 94) and the median length of hospital stay was four days (interquartile range: 3 to 5), with a 90 days re-admission rate of 9.9%, re-operation rate of 3.5% and mortality rate of 0.2%. The age ranges of 51 to 55 years (p = 0.018), 76 to 80 years (p < 0.001) and ≥ 81 years (p < 0.001) were related to an increased risk of re-admission. The age ranges of 76 to 80 years (p = 0.018) and the large partial revision subgroup (p = 0.073) were related to an increased risk of re-operation. The ages from 76 to 80 years (p < 0.001), age ≥ 81 years (p < 0.001) and surgical time > 120 min (p <  0.001) were related to increased length of hospital stay, whereas the use of a tourniquet (p = 0.008) and surgery in a low volume centre (p = 0.013) were related to shorter length of stay.

In conclusion, we found a similar incidence of early post-operative morbidity after aseptic knee revisions as has been reported after primary procedures. This suggests that a length of hospital stay ≤ four days and discharge home at that time is safe following aseptic knee revision surgery in Denmark.

Cite this article: Bone Joint J 2014;96-B:1649–56.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 49 - 57
1 Jan 2016
Bonnin MP Saffarini M Bossard N Dantony E Victor J

Aims

Analysis of the morphology of the distal femur, and by extension of the femoral components in total knee arthroplasty (TKA), has largely been related to the aspect ratio, which represents the width of the femur. Little is known about variations in trapezoidicity (i.e. whether the femur is more rectangular or more trapezoidal). This study aimed to quantify additional morphological characteristics of the distal femur and identify anatomical features associated with higher risks of over- or under-sizing of components in TKA.

Methods

We analysed the shape of 114 arthritic knees at the time of primary TKA using the pre-operative CT scans. The aspect ratio and trapezoidicity ratio were quantified, and the post-operative prosthetic overhang was calculated. We compared the morphological characteristics with those of 12 TKA models.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1470 - 1474
1 Nov 2015
Selvarajah E Hooper G Grabowski K Frampton C Woodfield TBF Inglis G

Polyethylene wear debris can cause osteolysis and the failure of total hip arthroplasty. We present the five-year wear rates of a highly cross-linked polyethylene (X3) bearing surface when used in conjunction with a 36 mm ceramic femoral head.

This was a prospective study of a cohort of 100 THAs in 93 patients. Pain and activity scores were measured pre- and post-operatively. Femoral head penetration was measured at two months, one year, two years and at five years using validated edge-detecting software (PolyWare Auto).

At a mean of 5.08 years (3.93 to 6.01), 85 hips in 78 patients were available for study. The mean age of these patients was 59.08 years (42 to 73, the mean age of males (n = 34) was 59.15 years, and females (n = 44) was 59.02 years). All patients had significant improvement in their functional scores (p < 0.001). The steady state two-dimensional linear wear rate was 0.109 mm/year. The steady state volumetric wear rate was 29.61 mm3/year. No significant correlation was found between rate of wear and age (p = 0.34), acetabular component size (p = 0.12) or clinical score (p = 0.74).

Our study shows low steady state wear rates at five years in X3 highly cross-linked polyethylene in conjunction with a 36 mm ceramic femoral head. The linear wear rate was almost identical to the osteolysis threshold of 0.1 mm/year recommended in the literature.

Cite this article: Bone Joint J 2015;97-B:1470–4.