Advertisement for orthosearch.org.uk
Results 321 - 340 of 539
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 120 - 124
1 Jan 2016
Sculco PK Abdel MP Hanssen AD Lewallen DG

The treatment of bone loss in revision total knee arthroplasty has evolved over the past decade. While the management of small to moderate sized defects has demonstrated good results with a variety of traditional techniques (cement and screws, small metal augments, impaction bone grafting or modular stems), the treatment of severe defects continues to be problematic. The use of a structural allograft has declined in recent years due to an increased failure rate with long-term follow-up and with the introduction of highly porous metal augments that emphasise biological metaphyseal fixation. Recently published mid-term results on the use of tantalum cones in patients with severe bone loss has reaffirmed the success of this treatment strategy.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):120–4.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 365 - 373
1 Mar 2016
Lucas y Hernandez J Golanó† P Roshan-Zamir S Darcel V Chauveaux D Laffenêtre O

Aims

The aim of this study was to report a single surgeon series of consecutive patients with moderate hallux valgus managed with a percutaneous extra-articular reverse-L chevron (PERC) osteotomy.

Patients and Methods

A total of 38 patients underwent 45 procedures. There were 35 women and three men. The mean age of the patients was 48 years (17 to 69). An additional percutaneous Akin osteotomy was performed in 37 feet and percutaneous lateral capsular release was performed in 22 feet. Clinical and radiological assessments included the type of forefoot, range of movement, the American Orthopedic Foot and Ankle (AOFAS) score, a subjective rating and radiological parameters.

The mean follow-up was 59.1 months (45.9 to 75.2). No patients were lost to follow-up.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 37 - 43
1 Jan 2016
Beverland DE O’Neill CKJ Rutherford M Molloy D Hill JC

Ideal placement of the acetabular component remains elusive both in terms of defining and achieving a target. Our aim is to help restore original anatomy by using the transverse acetabular ligament (TAL) to control the height, depth and version of the component. In the normal hip the TAL and labrum extend beyond the equator of the femoral head and therefore, if the definitive acetabular component is positioned such that it is cradled by and just deep to the plane of the TAL and labrum and is no more than 4mm larger than the original femoral head, the centre of the hip should be restored. If the face of the component is positioned parallel to the TAL and psoas groove the patient specific version should be restored. We still use the TAL for controlling version in the dysplastic hip because we believe that the TAL and labrum compensate for any underlying bony abnormality.

The TAL should not be used as an aid to inclination. Worldwide, > 75% of surgeons operate with the patient in the lateral decubitus position and we have shown that errors in post-operative radiographic inclination (RI) of > 50° are generally caused by errors in patient positioning. Consequently, great care needs to be taken when positioning the patient. We also recommend 35° of apparent operative inclination (AOI) during surgery, as opposed to the traditional 45°.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):37–43.


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 16 - 19
1 Oct 2015
Oussedik S Abdel MP Cross MB Haddad FS

Many aspects of total knee arthroplasty have changed since its inception. Modern prosthetic design, better fixation techniques, improved polyethylene wear characteristics and rehabilitation, have all contributed to a large change in revision rates. Arthroplasty patients now expect longevity of their prostheses and demand functional improvement to match. This has led to a re-examination of the long-held belief that mechanical alignment is instrumental to a successful outcome and a focus on restoring healthy joint kinematics. A combination of kinematic restoration and uncemented, adaptable fixation may hold the key to future advances.

Cite this article: Bone Joint J 2015;97-B(10 Suppl A):16–19.


Bone & Joint 360
Vol. 4, Issue 5 | Pages 16 - 18
1 Oct 2015

The October 2015 Wrist & Hand Roundup360 looks at: Base of thumb arthritis – steroids not a waste of time; De Quervain’s tenosynovitis and steroids; Use your therapy time wisely!; Excision osteotomy for the carpometacarpal joint?; CORDLESS at five years?; Arthroscopy again of no benefit?; Distal radius stirring up trouble again!; Scaphoid arthroscopy under the spotlight


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 536 - 542
1 Apr 2013
Puchwein P Jester B Freytag B Tanzer K Maizen C Gumpert R Pichler W

Ventral screw osteosynthesis is a common surgical method for treating fractures of the odontoid peg, but there is still no consensus about the number and diameter of the screws to be used. The purpose of this study was to develop a more accurate measurement technique for the morphometry of the odontoid peg (dens axis) and to provide a recommendation for ventral screw osteosynthesis.

Images of the cervical spine of 44 Caucasian patients, taken with a 64-line CT scanner, were evaluated using the measuring software MIMICS. All measurements were performed by two independent observers. Intraclass correlation coefficients were used to measure inter-rater variability.

The mean length of the odontoid peg was 39.76 mm (sd 2.68). The mean screw entry angle α was 59.45° (sd 3.45). The mean angle between the screw and the ventral border of C2 was 13.18° (sd 2.70), the maximum possible mean converging angle of two screws was 20.35° (sd 3.24). The measurements were obtained at the level of 66% of the total odontoid peg length and showed mean values of 8.36 mm (sd 0.84) for the inner diameter in the sagittal plane and 7.35 mm (sd 0.97) in the coronal plane. The mean outer diameter of the odontoid peg was 12.88 mm (sd 0.91) in the sagittal plane and 11.77 mm (sd 1.09) in the coronal plane. The results measured at the level of 90% of the total odontoid peg length were a mean of 6.12 mm (sd 1.14) for the sagittal inner diameter and 5.50 mm (sd 1.05) for the coronal inner diameter. The mean outer diameter of the odontoid peg was 11.10 mm (sd 1.0) in the sagittal plane and 10.00 mm (sd 1.07) in the coronal plane. In order to calculate the necessary screw length using 3.5 mm cannulated screws, 1.5 mm should be added to the measured odontoid peg length when anatomical reduction seems possible.

The cross-section of the odontoid peg is not circular but slightly elliptical, with a 10% greater diameter in the sagittal plane. In the majority of cases (70.5%) the odontoid peg offers enough room for two 3.5 mm cannulated cortical screws.

Cite this article: Bone Joint J 2013;95-B:536–42.


Bone & Joint Research
Vol. 4, Issue 10 | Pages 170 - 175
1 Oct 2015
Sandberg OH Aspenberg P

Objectives

Healing in cancellous metaphyseal bone might be different from midshaft fracture healing due to different access to mesenchymal stem cells, and because metaphyseal bone often heals without a cartilaginous phase. Inflammation plays an important role in the healing of a shaft fracture, but if metaphyseal injury is different, it is important to clarify if the role of inflammation is also different. The biology of fracture healing is also influenced by the degree of mechanical stability. It is unclear if inflammation interacts with stability-related factors.

Methods

We investigated the role of inflammation in three different models: a metaphyseal screw pull-out, a shaft fracture with unstable nailing (IM-nail) and a stable external fixation (ExFix) model. For each, half of the animals received dexamethasone to reduce inflammation, and half received control injections. Mechanical and morphometric evaluation was used.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1411 - 1416
1 Oct 2015
Li Y Yang S Chen H Kao Y Tu Y

We evaluated the impact of lumbar instrumented circumferential fusion on the development of adjacent level vertebral compression fractures (VCFs). Instrumented posterior lumbar interbody fusion (PLIF) has become a popular procedure for degenerative lumbar spine disease. The immediate rigidity produced by PLIF may cause more stress and lead to greater risk of adjacent VCFs. However, few studies have investigated the relationship between PLIF and the development of subsequent adjacent level VCFs.

Between January 2005 and December 2009, a total of 1936 patients were enrolled. Of these 224 patients had a new VCF and the incidence was statistically analysed with other covariants. In total 150 (11.1%) of 1348 patients developed new VCFs with PLIF, with 108 (72%) cases at adjacent segment. Of 588 patients, 74 (12.5%) developed new subsequent VCFs with conventional posterolateral fusion (PLF), with 37 (50%) patients at an adjacent level. Short-segment fusion, female and age older than 65 years also increased the development of new adjacent VCFs in patients undergoing PLIF. In the osteoporotic patient, more rigid fusion and a higher stress gradient after PLIF will cause a higher adjacent VCF rate.

Cite this article: Bone Joint J 2015;97-B:1411–16.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1667 - 1672
1 Dec 2013
Oh C Apivatthakakul T Oh J Kim J Lee H Kyung H Baek S Jung G

Although gradual bone transport may permit the restoration of large-diameter bones, complications are common owing to the long duration of external fixation. In order to reduce such complications, a new technique of bone transport involving the use of an external fixator and a locking plate was devised for segmental tibial bone defects.

A total of ten patients (nine men, one woman) with a mean age at operation of 40.4 years (16 to 64) underwent distraction osteogenesis with a locking plate to treat previously infected post-traumatic segmental tibial defects. The locking plate was fixed percutaneously to bridge proximal and distal segments, and was followed by external fixation. After docking, percutaneous screws were fixed at the transported segment through plate holes. At the same time, bone grafting was performed at the docking site with the external fixator removed.

The mean defect size was 5.9 cm (3.8 to 9.3) and mean external fixation index was 13.4 days/cm (11.8 to 19.5). In all cases, primary union of the docking site and distraction callus was achieved, with an excellent bony result. There was no recurrence of deep infection or osteomyelitis, and with the exception of one patient with a pre-existing peroneal nerve injury, all achieved an excellent or good functional result.

With short external fixation times and low complication rates, bone transport with a locking plate could be recommended for patients with segmental tibial defects.

Cite this article: Bone Joint J 2013;95-B:1667–72.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1208 - 1214
1 Sep 2016
Cowling PD Akhtar MA Liow RYL

Objectives

A variety of operative techniques have been described as under the term ‘Bristow-Latarjet’ procedure. This review aims to define the original procedure, and compare the variation in techniques described in the literature, assessing any effect on clinical outcomes.

Materials and Methods

A systematic review of 24 studies was performed to compare specific steps of the technique (coracoid osteotomy site, subscapularis approach, orientation and position of coracoid graft fixation and fixation method, additional labral and capsular repair) and detect any effect this variability had on outcomes.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1428 - 1434
1 Oct 2015
Clement ND Vats A Duckworth AD Gaston MS Murray AW

Controversy remains whether the contralateral hip should be fixed in patients presenting with unilateral slipped capital femoral epiphysis (SCFE). This retrospective study compares the outcomes and cost of those patients who had prophylactic fixation with those who did not.

Between January 2000 and December 2010 a total of 50 patients underwent unilateral fixation and 36 had prophylactic fixation of the contralateral hip. There were 54 males and 32 females with a mean age of 12.3 years (9 to 16). The rate of a subsequent slip without prophylactic fixation was 46%. The risk of complications was greater, the generic health measures (Short Form-12 physical (p < 0.001) and mental (p = 0.004) summary scores) were worse. Radiographic cam lesions in patients presenting with unilateral SCFE were only seen in patients who did not have prophylactic fixation. Furthermore, prophylactic fixation of the contralateral hip was found to be a cost-effective procedure, with a cost per quality adjusted life year gained of £1431 at the time of last follow-up.

Prophylactic fixation of the contralateral hip is a cost-effective operation that limits the morbidity from the complications of a further slip, and the diminished functional outcome associated with unilateral fixation.

Cite this article: Bone Joint J 2015;97-B:1428–34.


We evaluated the outcome of treatment of nonunion of an intracapsular fracture of the femoral neck in young patients using two cannulated screws and a vascularised bone graft. A total of 32 patients (15 women and 17 men, with a mean age of 36.5 years; 20 to 50) with failed internal fixation of an intracapsular fracture were included in the study. Following removal of the primary fixation, two cannulated compression screws were inserted with a vascularised iliac crest bone graft based on the ascending branch of the lateral femoral circumflex artery.

At a mean follow-up of 6.8 years (4 to 10), union was achieved in 27 hips (84%). A total of five patients with a mean age of 40.5 years (35 to 50) had a persistent nonunion and underwent total hip arthroplasty as also did two patients whose fracture united but who developed osteonecrosis of the femoral head two years post-operatively. Statistical analysis showed that younger patients achieved earlier and more reliable union (p < 0.001). The functional outcome, as assessed by the Harris Hip score, was better in patients aged < 45 years compared with those aged > 45 years (p < 0.001).

These findings suggest that further fixation using two cannulated compression screws and a vascularised iliac crest bone graft is an effective salvage treatment in patients aged <  45 years, in whom osteosynthesis of a displaced intracapsular fractures of the femoral neck has failed.

Cite this article: Bone Joint J 2015; 97-B:988–91.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 950 - 955
1 Jul 2014
Guzman JZ Baird EO Fields AC McAnany SJ Qureshi SA Hecht AC Cho SK

C5 nerve root palsy is a rare and potentially debilitating complication of cervical spine surgery. Currently, however, there are no guidelines to help surgeons to prevent or treat this complication.

We carried out a systematic review of the literature to identify the causes of this complication and options for its prevention and treatment. Searches of PubMed, Embase and Medline yielded 60 articles for inclusion, most of which addressed C5 palsy as a complication of surgery. Although many possible causes were given, most authors supported posterior migration of the spinal cord with tethering of the nerve root as being the most likely.

Early detection and prevention of a C5 nerve root palsy using neurophysiological monitoring and variations in surgical technique show promise by allowing surgeons to minimise or prevent the incidence of C5 palsy. Conservative treatment is the current treatment of choice; most patients make a full recovery within two years.

Cite this article: Bone Joint J 2014;96-B:950–5.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1242 - 1249
1 Sep 2015
Hintermann B Wagener J Knupp M Schweizer C J. Schaefer D

Large osteochondral lesions (OCLs) of the shoulder of the talus cannot always be treated by traditional osteochondral autograft techniques because of their size, articular geometry and loss of an articular buttress. We hypothesised that they could be treated by transplantation of a vascularised corticoperiosteal graft from the ipsilateral medial femoral condyle.

Between 2004 and 2011, we carried out a prospective study of a consecutive series of 14 patients (five women, nine men; mean age 34.8 years, 20 to 54) who were treated for an OCL with a vascularised bone graft. Clinical outcome was assessed using a visual analogue scale (VAS) for pain and the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score. Radiological follow-up used plain radiographs and CT scans to assess graft incorporation and joint deterioration.

At a mean follow-up of 4.1 years (2 to 7), the mean VAS for pain had decreased from 5.8 (5 to 8) to 1.8 (0 to 4) (p = 0.001) and the mean AOFAS hindfoot score had increased from 65 (41 to 70) to 81 (54 to 92) (p = 0.003). Radiologically, the talar contour had been successfully reconstructed with stable incorporation of the vascularised corticoperiosteal graft in all patients. Joint degeneration was only seen in one ankle.

Treatment of a large OCL of the shoulder of the talus with a vascularised corticoperiosteal graft taken from the medial condyle of the femur was found to be a safe, reliable method of restoring the contour of the talus in the early to mid-term.

Cite this article: Bone Joint J 2015;97-B:1242–9.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1197 - 1203
1 Sep 2015
Kim Y Park J Kim J

A number of studies have reported satisfactory results from the isolated revision of an acetabular component. However, many of these studies reported only the short- to intermediate-term results of heterogeneous bearing surfaces in a mixed age group.

We present our experience of using a ceramic-on-ceramic (CoC) bearing for isolated revision of an uncemented acetabular component in 166 patients (187 hips) who were under the age of 50 years at the time of revision. There were 78 men and 88 women with a mean age of 47.4 years (28 to 49). The most common reason for revision was polyethylene wear and acetabular osteolysis in 123 hips (66%), followed by aseptic loosening in 49 hips (26%).

We report the clinical and radiological outcome, complication rate, and survivorship of this group. The mean duration of follow-up was 15.6 years (11 to 19).

The mean pre-operative Harris hip score was 33 points (1 to 58), and improved to a mean of 88 points (51 to 100) at follow-up. The mean pre-operative total Western Ontario and McMaster Universities Osteoarthritis Index score was 63.2 (43 to 91) and improved to 19.8 points (9 to 61) post-operatively. Overall, 153 of 166 patients (92%) were satisfied with their outcome. Kaplan–Meier survivorship analysis, with revision or radiological evidence of implant failure (13 patients, 8%) as end-points, was 92% at 15 years (95% confidence interval 0.89 to 0.97).

Isolated revision of a cementless acetabular component using a CoC bearing gives good results in patients under 50 years of age.

Cite this article: Bone Joint J 2015;97-B:1197–1203.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1226 - 1231
1 Sep 2015
Nakamura R Komatsu N Murao T Okamoto Y Nakamura S Fujita K Nishimura H Katsuki Y

The objective of this study was to validate the efficacy of Takeuchi classification for lateral hinge fractures (LHFs) in open wedge high tibial osteotomy (OWHTO). In all 74 osteoarthritic knees (58 females, 16 males; mean age 62.9 years, standard deviation 7.5, 42 to 77) were treated with OWHTO using a TomoFix plate. The knees were divided into non-fracture (59 knees) and LHF (15 knees) groups, and the LHF group was further divided into Takeuchi types I, II, and III (seven, two, and six knees, respectively). The outcomes were assessed pre-operatively and one year after OWHTO. Pre-operative characteristics (age, gender and body mass index) showed no significant difference between the two groups. The mean Japanese Orthopaedic Association score was significantly improved one year after operation regardless of the presence or absence of LHF (p = 0.0015, p < 0.001, respectively). However, six of seven type I cases had no LHF-related complications; both type II cases had delayed union; and of six type III cases, two had delayed union with correction loss and one had overcorrection. These results suggest that Takeuchi type II and III LHFs are structurally unstable compared with type I.

Cite this article: Bone Joint J 2015;97-B:1226–31.


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1082 - 1089
1 Aug 2014
Roberts SB Tsirikos AI Subramanian AS

Clinical, radiological, and Scoliosis Research Society-22 questionnaire data were reviewed pre-operatively and two years post-operatively for patients with thoracolumbar/lumbar adolescent idiopathic scoliosis treated by posterior spinal fusion using a unilateral convex segmental pedicle screw technique. A total of 72 patients were included (67 female, 5 male; mean age at surgery 16.7 years (13 to 23)) and divided into groups: group 1 included 53 patients who underwent fusion between the vertebrae at the limit of the curve (proximal and distal end vertebrae); group 2 included 19 patients who underwent extension of the fusion distally beyond the caudal end vertebra.

A mean scoliosis correction of 80% (45% to 100%) was achieved. The mean post-operative lowest instrumented vertebra angle, apical vertebra translation and trunk shift were less than in previous studies. A total of five pre-operative radiological parameters differed significantly between the groups and correlated with the extension of the fusion distally: the size of the thoracolumbar/lumbar curve, the lowest instrumented vertebra angle, apical vertebra translation, the Cobb angle on lumbar convex bending and the size of the compensatory thoracic curve. Regression analysis allowed an equation incorporating these parameters to be developed which had a positive predictive value of 81% in determining whether the lowest instrumented vertebra should be at the caudal end vertebra or one or two levels more distal. There were no differences in the Scoliosis Research Society-22 outcome scores between the two groups (p = 0.17).

In conclusion, thoracolumbar/lumbar curves in patients with adolescent idiopathic scoliosis may be effectively treated by posterior spinal fusion using a unilateral segmental pedicle screw technique. Five radiological parameters correlate with the need for distal extension of the fusion, and an equation incorporating these parameters reliably informs selection of the lowest instrumented vertebra.

Cite this article: Bone Joint J 2014;96-B:1082–9.


Bone & Joint 360
Vol. 2, Issue 3 | Pages 31 - 33
1 Jun 2013

The June 2013 Trauma Roundup360 looks at: open foot fractures; the diagnostic accuracy of continuous compartment pressure monitoring; conservative treatment for supracondylar fractures; high complication rates in patellar fractures; vitamin D and fracture; better function with K-wires; and tensionless bands.


Bone & Joint 360
Vol. 4, Issue 2 | Pages 35 - 36
1 Apr 2015
Forward DP Lewis CP


Bone & Joint 360
Vol. 4, Issue 2 | Pages 23 - 25
1 Apr 2015

The April 2015 Spine Roundup360 looks at: Hyperostotic spine in injury; App based back pain control; Interspinous process devices should be avoided in claudication; Robot assisted pedicle screws: fad or advance?; Vancomycin antibiotic power in spinal surgery; What to do with that burst fracture?; Increasing complexity of spinal fractures in major trauma pathways; Vitamin D and spinal fractures