Vol. 99-B, Issue 10 | Pages 1267 - 1279
1 Oct 2017
Chughtai M Piuzzi NS Khlopas A Jones LC Goodman SB Mont MA

Non-traumatic osteonecrosis of the femoral head is a potentially devastating condition, the prevalence of which is increasing. Many joint-preserving forms of treatment, both medical and surgical, have been developed in an attempt to slow or reverse its progression, as it usually affects young patients.

However, it is important to evaluate the best evidence that is available for the many forms of treatment considering the variation in the demographics of the patients, the methodology and the outcomes in the studies that have been published, so that it can be used effectively.

The purpose of this review, therefore, was to provide an up-to-date, evidence-based guide to the management, both non-operative and operative, of non-traumatic osteonecrosis of the femoral head.

Cite this article: Bone Joint J 2017;99-B:1267–79.


Bone & Joint Research
Vol. 5, Issue 6 | Pages 232 - 238
1 Jun 2016
Tanaka A Yoshimura Y Aoki K Kito M Okamoto M Suzuki S Momose T Kato H

Objectives

Our objective was to predict the knee extension strength and post-operative function in quadriceps resection for soft-tissue sarcoma of the thigh.

Methods

A total of 18 patients (14 men, four women) underwent total or partial quadriceps resection for soft-tissue sarcoma of the thigh between 2002 and 2014. The number of resected quadriceps was surveyed, knee extension strength was measured with the Biodex isokinetic dynamometer system (affected side/unaffected side) and relationships between these were examined. The Musculoskeletal Tumor Society (MSTS) score, Toronto Extremity Salvage Score (TESS), European Quality of Life-5 Dimensions (EQ-5D) score and the Short Form 8 were used to evaluate post-operative function and examine correlations with extension strength. The cutoff value for extension strength to expect good post-operative function was also calculated using a receiver operating characteristic (ROC) curve and Fisher’s exact test.


Bone & Joint 360
Vol. 4, Issue 6 | Pages 20 - 21
1 Dec 2015

The December 2015 Spine Roundup360 looks at: Ketamine in scoliosis surgery; Teriparatide in osteoporotic spinal fractures; Trabecular metal in the spine?; Revision surgery a SPORTing chance?; The course of degenerative lumbar spondylolisthesis; Hip or lumbar spine: a common conundrum


Bone & Joint Research
Vol. 6, Issue 7 | Pages 423 - 432
1 Jul 2017
van der Stok J Hartholt KA Schoenmakers DAL Arts JJC

Objectives

The aim of this systematic literature review was to assess the clinical level of evidence of commercially available demineralised bone matrix (DBM) products for their use in trauma and orthopaedic related surgery.

Methods

A total of 17 DBM products were used as search terms in two available databases: Embase and PubMed according to the Preferred Reporting Items for Systematic Reviews and Meta Analyses statement. All articles that reported the clinical use of a DBM-product in trauma and orthopaedic related surgery were included.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 977 - 982
1 Jul 2013
Wu AM Tian NF Wu LJ He W Ni WF Wang XY Xu HZ Chi YL

The purpose of this study was to determine whether it would be feasible to use oblique lumbar interbody fixation for patients with degenerative lumbar disease who required a fusion but did not have a spondylolisthesis.

A series of CT digital images from 60 patients with abdominal disease were reconstructed in three dimensions (3D) using Mimics v10.01: a digital cylinder was superimposed on the reconstructed image to simulate the position of an interbody screw. The optimal entry point of the screw and measurements of its trajectory were recorded. Next, 26 cadaveric specimens were subjected to oblique lumbar interbody fixation on the basis of the measurements derived from the imaging studies. These were then compared with measurements derived directly from the cadaveric vertebrae.

Our study suggested that it is easy to insert the screws for L1/2, L2/3 and L3/4 fixation: there was no significant difference in measurements between those of the 3-D digital images and the cadaveric specimens. For L4/5 fixation, part of L5 inferior articular process had to be removed to achieve the optimal trajectory of the screw. For L5/S1 fixation, the screw heads were blocked by iliac bone: consequently, the interior oblique angle of the cadaveric specimens was less than that seen in the 3D digital images.

We suggest that CT scans should be carried out pre-operatively if this procedure is to be adopted in clinical practice. This will assist in determining the feasibility of the procedure and will provide accurate information to assist introduction of the screws.

Cite this article: Bone Joint J 2013;95-B:977–82.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 705 - 710
1 May 2015
Ozmeric A Yucens M Gultaç E Açar HI Aydogan NH Gül D Alemdaroglu KB

We hypothesised that the anterior and posterior walls of the body of the first sacral vertebra could be visualised with two different angles of inlet view, owing to the conical shape of the sacrum. Six dry male cadavers with complete pelvic rings and eight dry sacrums with K-wires were used to study the effect of canting (angling the C-arm) the fluoroscope towards the head in 5° increments from 10° to 55°. Fluoroscopic images were taken in each position. Anterior and posterior angles of inclination were measured between the upper sacrum and the vertical line on the lateral view. Three authors separately selected the clearest image for overlapping anterior cortices and the upper sacral canal in the cadaveric models. The dry bone and K-wire models were scored by the authors, being sure to check whether the K-wire was in or out.

In the dry bone models the mean score of the relevant inlet position of the anterior or posterior inclination was 8.875 (standard deviation (sd) 0.35), compared with the inlet position of the opposite inclination of –5.75 (sd 4.59). We found that two different inlet views should be used separately to evaluate the borders of the body of the sacrum using anterior and posterior inclination angles of the sacrum, during placement of iliosacral screws.

Cite this article: Bone Joint J 2015;97-B:705–10.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1441 - 1448
1 Nov 2014
Bali K Railton P Kiefer GN Powell JN

We report the clinical and radiological outcome of subcapital osteotomy of the femoral neck in the management of symptomatic femoroacetabular impingement (FAI) resulting from a healed slipped capital femoral epiphysis (SCFE). We believe this is only the second such study in the literature.

We studied eight patients (eight hips) with symptomatic FAI after a moderate to severe healed SCFE. There were six male and two female patients, with a mean age of 17.8 years (13 to 29).

All patients underwent a subcapital intracapsular osteotomy of the femoral neck after surgical hip dislocation and creation of an extended retinacular soft-tissue flap. The mean follow-up was 41 months (20 to 84). Clinical assessment included measurement of range of movement, Harris Hip Score (HHS) and Western Ontario and McMaster Universities Osteoarthritis score (WOMAC). Radiological assessment included pre- and post-operative calculation of the anterior slip angle (ASA) and lateral slip angle (LSA), the anterior offset angle (AOA) and centre head–trochanteric distance (CTD). The mean HHS at final follow-up was 92.5 (85 to 100), and the mean WOMAC scores for pain, stiffness and function were 1.3 (0 to 4), 1.4 (0 to 6) and 3.6 (0 to 19) respectively. There was a statistically significant improvement in all the radiological measurements post-operatively. The mean ASA improved from 36.6° (29° to 44°) to 10.3° (5° to 17°) (p <  0.01). The mean LSA improved from 36.6° (31° to 43°) to 15.4° (8° to 21°) (p < 0.01). The mean AOA decreased from 64.4° (50° to 78°) 32.0° (25° to 39°) post-operatively (p < 0.01). The mean CTD improved from -8.2 mm (-13.8 to +3.1) to +2.8 mm (-7.6 to +11.0) (p < 0.01). Two patients underwent further surgery for nonunion. No patient suffered avascular necrosis of the femoral head.

Subcapital osteotomy for patients with a healed SCFE is more challenging than subcapital re-orientation in those with an acute or sub-acute SCFE and an open physis. An effective correction of the deformity, however, can be achieved with relief of symptoms related to impingement.

Cite this article: Bone Joint J 2014;96-B:1441–8.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 102 - 108
1 Jan 2016
Kang C Kim C Moon J

Aims

The aims of this study were to evaluate the clinical and radiological outcomes of instrumented posterolateral fusion (PLF) performed in patients with rheumatoid arthritis (RA).

Methods

A total of 40 patients with RA and 134 patients without RA underwent instrumented PLF for spinal stenosis between January 2003 and December 2011. The two groups were matched for age, gender, bone mineral density, the history of smoking and diabetes, and number of fusion segments.

The clinical outcomes measures included the visual analogue scale (VAS) and the Korean Oswestry Disability Index (KODI), scored before surgery, one year and two years after surgery. Radiological outcomes were evaluated for problems of fixation, nonunion, and adjacent segment disease (ASD). The mean follow-up was 36.4 months in the RA group and 39.1 months in the non-RA group.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 517 - 522
1 Apr 2013
Henry PDG Dwyer T McKee MD Schemitsch EH

Latissimus dorsi tendon transfer (LDTT) is technically challenging. In order to clarify the local structural anatomy, we undertook a morphometric study using six complete cadavers (12 shoulders). Measurements were made from the tendon to the nearby neurovascular structures with the arm in two positions: flexed and internally rotated, and adducted in neutral rotation. The tendon was then transferred and measurements were taken from the edge of the tendon to a reference point on the humeral head in order to assess the effect of a novel two-stage release on the excursion of the tendon.

With the shoulder flexed and internally rotated, the mean distances between the superior tendon edge and the radial nerve, brachial artery, axillary nerve and posterior circumflex artery were 30 mm (26 to 34), 28 mm (17 to 39), 21 mm (12 to 28) and 15 mm (10 to 21), respectively. The mean distance between the inferior tendon edge and the radial nerve, brachial artery and profunda brachii artery was 18 mm (8 to 27), 22 mm (15 to 32) and 14 mm (7 to 21), respectively. Moving the arm to a neutral position reduced these distances. A mean of 15 mm (8 to 21) was gained from a standard soft-tissue release, and 32 mm (20 to 45) from an extensile release.

These figures help to define further the structural anatomy of this region and the potential for transfer of the latissimus dorsi tendon.

Cite this article: Bone Joint J 2013;95-B:517–22.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 535 - 540
1 Apr 2014
Nagahama K Sudo H Abumi K Ito M Takahata M Hiratsuka S Kuroki K Iwasaki N

We investigated the incidence of anomalies in the vertebral arteries and Circle of Willis with three-dimensional CT angiography in 55 consecutive patients who had undergone an instrumented posterior fusion of the cervical spine.

We recorded any peri-operative and post-operative complications. The frequency of congenital anomalies was 30.9%, abnormal vertebral artery blood flow was 58.2% and vertebral artery dominance 40%.

The posterior communicating artery was occluded on one side in 41.8% of patients and bilaterally in 38.2%. Variations in the vertebral arteries and Circle of Willis were not significantly related to the presence or absence of posterior communicating arteries. Importantly, 18.2% of patients showed characteristic variations in the Circle of Willis with unilateral vertebral artery stenosis or a dominant vertebral artery, indicating that injury may cause lethal complications. One patient had post-operative cerebellar symptoms due to intra-operative injury of the vertebral artery, and one underwent a different surgical procedure because of insufficient collateral circulation.

Pre-operative assessment of the vertebral arteries and Circle of Willis is essential if a posterior spinal fusion with instrumentation is to be carried out safely.

Cite this article: Bone Joint J 2014;96-B:535–40.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 270 - 273
1 Feb 2014
Ogura K Miyamoto S Sakuraba M Chuman H Fujiwara T Kawai A

Resection of malignant bony tumours of the pelvis creates large bone and soft-tissue defects, and is frequently associated with complications such as wound dehiscence and deep infection. We present the results of six patients in whom a rectus abdominis myocutaneous (RAM) flap was used following resection of a malignant tumour of the pelvis. Bony reconstruction was performed using a constrained hip tumour prosthesis in three patients, vascularised fibular graft in two and frozen autograft in one. At a mean follow-up of 63 months (16 to 115), no patients had a problem with the wound.

Immediate reconstruction using a RAM flap may be used after resection of a malignant tumour of the pelvis to provide an adequate volume of tissue to eliminate the dead space, cover the exposed bone or implants with well-vascularised soft tissue and to reduce the risk of complications.

Cite this article: Bone Joint J 2014;96-B:270–3.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 800 - 806
1 Jun 2014
Karampalis C Tsirikos AI

We describe 13 patients with cerebral palsy and lordoscoliosis/hyperlordosis of the lumbar spine who underwent a posterior spinal fusion at a mean age of 14.5 years (10.8 to 17.4) to improve sitting posture and relieve pain. The mean follow-up was 3.3 years (2.2 to 6.2).

The mean pre-operative lumbar lordosis was 108° (80 to 150°) and was corrected to 62° (43° to 85°); the mean thoracic kyphosis from 17° (-23° to 35°) to 47° (25° to 65°); the mean scoliosis from 82° (0° to 125°) to 22° (0° to 40°); the mean pelvic obliquity from 21° (0° to 38°) to 3° (0° to 15°); the mean sacral slope from 79° (54° to 90°) to 50° (31° to 66°). The mean pre-operative coronal imbalance was 5 cm (0 cm to 8.9 cm) and was corrected to 0.6 cm (0 to 3.2). The mean sagittal imbalance of -8 cm (-16 cm to 7.8 cm) was corrected to -1.6 cm (-4 cm to 2.5 cm). The mean operating time was 250 minutes (180 to 360 minutes) and intra-operative blood loss 0.8 of estimated blood volume (0.3 to 2 estimated blood volume). The mean intensive care and hospital stay were 3.5 days (2 to 8) and 14.5 days (10 to 27), respectively. Three patients lost a significant amount of blood intra-operatively and subsequently developed chest or urinary infections and superior mesenteric artery syndrome.

An increased pre-operative lumbar lordosis and sacral slope were associated with increased peri-operative morbidity: scoliosis and pelvic obliquity were not. A reduced lumbar lordosis and increased thoracic kyphosis correlated with better global sagittal balance at follow-up. All patients and their parents reported excellent surgical outcomes.

Lordoscoliosis and hyperlordosis are associated with significant morbidity in quadriplegic patients. They are rare deformities and their treatment is challenging. Sagittal imbalance is the major component: it can be corrected by posterior fusion of the spine with excellent functional results.

Cite this article: Bone Joint J 2014;96-B:800–6.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 399 - 405
1 Mar 2014
Zang J Guo W Yang Y Xie L

We report our early experience with the use of a new prosthesis, the Modular Hemipelvic Prosthesis II, for reconstruction of the hemipelvis after resection of a primary malignant peri-acetabular tumour involving the sacroiliac joint.

We retrospectively reviewed the outcome of 17 patients who had undergone resection of a pelvic tumour and reconstruction with this prosthesis between July 2002 and July 2010.

One patient had a type I+II+III+IV resection (ilium + peri-acetabulum + pubis/ischium + sacrum) and 16 had a type I+II+IV resection (ilium + acetabulum + sacrum). The outcome was assessed at a mean follow-up of 33 months (15 to 59). One patient was alive with disease, 11 were alive without disease and five had died of disease. The overall five-year survival rate was 62.4%. Six patients had a local recurrence. The mean Musculoskeletal Tumour Society score was 58% (33 to 77). Deep infection occurred in two patients, problems with wound healing in five and dislocation in one.

For patients with a primary malignant peri-acetabular sarcoma involving the sacroiliac joint, we believe that this new prosthesis is a viable option for reconstruction of the bony defect left following resection of the tumour. It results in a satisfactory functional outcome with an acceptable rate of complications.

Cite this article: Bone Joint J 2014;96-B:399–405.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 175 - 183
1 Feb 2017
Morita D Hasegawa Y Okura T Osawa Y Ishiguro N

Aims

Transtrochanteric rotational osteotomy (TRO) is performed for young patients with non-traumatic osteonecrosis of the femoral head (ONFH) to preserve the hip. We aimed to investigate the long-term outcomes and the risk factors for failure 15 years after this procedure.

Patients and Methods

This study included 95 patients (111 hips) with a mean age of 40 years (21 to 64) who underwent TRO for ONFH. The mean follow-up was 18.2 years (3 to 26). Kaplan–Meier survivorship analyses were performed with conversion to total hip arthroplasty (THA) and radiological failure due to secondary collapse of the femoral head or osteoarthritic changes as the endpoint. Multivariate analyses were performed to assess risk factors for each outcome.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 358 - 365
1 Mar 2015
Zhu L F. Zhang Yang D Chen A

The aim of this study was to evaluate the feasibility of using the intact S1 nerve root as a donor nerve to repair an avulsion of the contralateral lumbosacral plexus. Two cohorts of patients were recruited. In cohort 1, the L4–S4 nerve roots of 15 patients with a unilateral fracture of the sacrum and sacral nerve injury were stimulated during surgery to establish the precise functional distribution of the S1 nerve root and its proportional contribution to individual muscles. In cohort 2, the contralateral uninjured S1 nerve root of six patients with a unilateral lumbosacral plexus avulsion was transected extradurally and used with a 25 cm segment of the common peroneal nerve from the injured leg to reconstruct the avulsed plexus.

The results from cohort 1 showed that the innervation of S1 in each muscle can be compensated for by L4, L5, S2 and S3. Numbness in the toes and a reduction in strength were found after surgery in cohort 2, but these symptoms gradually disappeared and strength recovered. The results of electrophysiological studies of the donor limb were generally normal.

Severing the S1 nerve root does not appear to damage the healthy limb as far as clinical assessment and electrophysiological testing can determine. Consequently, the S1 nerve can be considered to be a suitable donor nerve for reconstruction of an avulsed contralateral lumbosacral plexus.

Cite this article: Bone Joint J 2015; 97-B:358–65.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 950 - 955
1 Jul 2012
Helenius I Serlo J Pajulo O

We report the results of vertebral column resection (VCR) for paediatric patients with spinal deformity. A total of 49 VCRs in paediatric patients from four university hospitals between 2005 and 2009 with a minimum two-year follow-up were retrospectively identified. After excluding single hemivertebral resections (n = 25) and VCRs performed for patients with myelomeningocele (n = 6), as well as spondylectomies performed for tumour (n = 4), there were 14 patients who had undergone full VCR at a mean age of 12.3 years (6.5 to 17.9). The aetiology was congenital scoliosis in five, neuromuscular scoliosis in three, congenital kyphosis in two, global kyphosis in two, adolescent idiopathic scoliosis in one and secondary scoliosis in one. A total of seven anteroposterior and seven posterolateral approaches were used.

The mean major curve deformity was 86° (67° to 120°) pre-operatively and 37° (17° to 80°) at the two-year follow-up; correction was a mean of 54% (18% to 86%) in the anteroposterior and 60% (41% to 70%) in the posterolateral group at the two-year follow-up (p = 0.53). The mean Scoliosis Research Society-24 total scores were 100 (92 to 108) for the anteroposterior and 102 (95 to 105) for the posterolateral group. There was one paraparesis in the anteroposterior group necessitating urgent re-decompression, with a full recovery.

Patients undergoing VCR are highly satisfied after a successful procedure.


Bone & Joint 360
Vol. 4, Issue 2 | Pages 39 - 40
1 Apr 2015
Wilson-MacDonald MJ


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 717 - 723
1 Jun 2014
Altaf F Heran MKS Wilson LF

Back pain is a common symptom in children and adolescents. Here we review the important causes, of which defects and stress reactions of the pars interarticularis are the most common identifiable problems. More serious pathology, including malignancy and infection, needs to be excluded when there is associated systemic illness. Clinical evaluation and management may be difficult and always requires a thorough history and physical examination. Diagnostic imaging is obtained when symptoms are persistent or severe. Imaging is used to reassure the patient, relatives and carers, and to guide management.

Cite this article: Bone Joint J 2014;96-B:717–23.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1227 - 1233
1 Sep 2016
Bao H Yan P Qiu Y Liu Z Zhu F

Aims

There is a paucity of information on the pre-operative coronal imbalance in patients with degenerative lumbar scoliosis (DLS) and its influence on surgical outcomes.

Patients and Methods

A total of 284 DLS patients were recruited into this study, among whom 69 patients were treated surgically and the remaining 215 patients conservatively Patients were classified based on the coronal balance distance (CBD): Type A, CBD < 3 cm; Type B, CBD > 3 cm and C7 Plumb Line (C7PL) shifted to the concave side of the curve; Type C, CBD > 3 cm and C7PL shifted to the convex side.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1282 - 1288
1 Sep 2010
Shen GW Wu NQ Zhang N Jin ZS Xu J Yin GY

This study prospectively compared the efficacy of kyphoplasty using a Jack vertebral dilator and balloon kyphoplasty to treat osteoporotic compression fractures between T10 and L5. Between 2004 and 2009, two groups of 55 patients each underwent vertebral dilator kyphoplasty and balloon kyphoplasty, respectively. Pain, function, the Cobb angle, and the anterior and middle height of the vertebral body were assessed before and after operation. Leakage of bone cement was recorded. The post-operative change in the Cobb angle was significantly greater in the dilator kyphoplasty group than in the balloon kyphoplasty group (−9.51° (sd 2.56) vs −7.78° (sd 1.19), p < 0.001)). Leakage of cement was less in the dilator kyphoplasty group. No other significant differences were found in the two groups after operation, and both procedures gave equally satisfactory results in terms of all other variables assessed. No serious complications occurred in either group.

These findings suggest that vertebral dilator kyphoplasty can facilitate better correction of kyphotic deformity and may ultimately be a safer procedure in reducing leakage of bone cement.