header advert
Results 261 - 280 of 284
Results per page:
Bone & Joint 360
Vol. 1, Issue 4 | Pages 10 - 12
1 Aug 2012

The August 2012 Hip & Pelvis Roundup360 looks at: whether cemented hip replacement might be bad for your health; highly cross-linked polyethylene; iHOT-33 - a new hip outcome measure; hamstring injuries; total hip replacement; stemmed metal-on-metal THR; bipolar hemiarthroplasty, neuromuscular disease and dislocation; the high risk of secondary hemiarthroplasty; and whether we have to repair the labrum after all?


Bone & Joint Research
Vol. 2, Issue 2 | Pages 18 - 25
1 Feb 2013
Kon E Filardo G Di Matteo B Perdisa F Marcacci M

Objectives

Matrix-assisted autologous chondrocyte transplantation (MACT) has been developed and applied in the clinical practice in the last decade to overcome most of the disadvantages of the first generation procedures. The purpose of this systematic review is to document and analyse the available literature on the results of MACT in the treatment of chondral and osteochondral lesions of the knee.

Methods

All studies published in English addressing MACT procedures were identified, including those that fulfilled the following criteria: 1) level I-IV evidence, 2) measures of functional or clinical outcome, 3) outcome related to cartilage lesions of the knee cartilage.


Bone & Joint 360
Vol. 1, Issue 1 | Pages 12 - 13
1 Feb 2012


Bone & Joint Research
Vol. 1, Issue 12 | Pages 324 - 332
1 Dec 2012
Verhelst L Guevara V De Schepper J Van Melkebeek J Pattyn C Audenaert EA

The aim of this review is to evaluate the current available literature evidencing on peri-articular hip endoscopy (the third compartment). A comprehensive approach has been set on reports dealing with endoscopic surgery for recalcitrant trochanteric bursitis, snapping hip (or coxa-saltans; external and internal), gluteus medius and minimus tears and endoscopy (or arthroscopy) after total hip arthroplasty. This information can be used to trigger further research, innovation and education in extra-articular hip endoscopy.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 729 - 734
1 Jun 2012
Kakkos SK Warwick D Nicolaides AN Stansby GP Tsolakis IA

We performed a systematic review and meta-analysis to compare the efficacy of intermittent mechanical compression combined with pharmacological thromboprophylaxis, against either mechanical compression or pharmacological prophylaxis in preventing deep-vein thrombosis (DVT) and pulmonary embolism in patients undergoing hip or knee replacement. A total of six randomised controlled trials, evaluating a total of 1399 patients, were identified. In knee arthroplasty, the rate of DVT was reduced from 18.7% with anticoagulation alone to 3.7% with combined modalities (risk ratio (RR) 0.27, p = 0.03; number needed to treat: seven). There was moderate, albeit non-significant, heterogeneity (I2 = 42%). In hip replacement, there was a non-significant reduction in DVT from 8.7% with mechanical compression alone to 7.2% with additional pharmacological prophylaxis (RR 0.84) and a significant reduction in DVT from 9.7% with anticoagulation alone to 0.9% with additional mechanical compression (RR 0.17, p < 0.001; number needed to treat: 12), with no heterogeneity (I2 = 0%). The included studies had insufficient power to demonstrate an effect on pulmonary embolism.

We conclude that the addition of intermittent mechanical leg compression augments the efficacy of anticoagulation in preventing DVT in patients undergoing both knee and hip replacement. Further research on the role of combined modalities in thromboprophylaxis in joint replacement and in other high-risk situations, such as fracture of the hip, is warranted.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1305 - 1312
1 Oct 2012
Adams J Ryall C Pandyan A Metcalf C Stokes M Bradley S Warwick DJ

We systematically reviewed all the evidence published in the English language on proximal interphalangeal joint (PIPJ) replacement, to determine its effectiveness on the function of the hand and the associated post-operative complications.

Original studies were selected if they reported clinical outcome with a minimum of one year’s follow-up. Quality was assessed using the Cowley systematic review criteria modified for finger-joint replacements. Of 319 articles identified, only five were adequately reported according to our quality criteria; there were no randomised controlled trials. PIPJ replacements had a substantial effect size on hand pain of -23.2 (95% confidence interval (CI) -27.3 to -19.1) and grip strength 1.2 (95% CI -10.7 to 13.1), and a small effect on range of movement 0.2 (95% CI -0.4 to 0.8). A dorsal approach was most successful. Post-operative loosening occurred in 10% (95% CI 3 to 30) of ceramic and 12.5% (95% CI 7 to 21) of pyrocarbon replacements. Post-operative complications occurred in 27.8% (95% CI 20 to 37).

We conclude that the effectiveness of PIPJ replacement has not been established. Small observational case studies and short-term follow-up, together with insufficient reporting of patient data, functional outcomes and complications, limit the value of current evidence.

We recommend that a defined core set of patients, surgical and outcome data for this intervention be routinely and systematically collected within the framework of a joint registry.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 152 - 157
1 Feb 2012
Longo UG Loppini M Denaro L Maffulli N Denaro V

Osteoporotic vertebral compression fractures (VCFs) are an increasing public health problem. Recently, randomised controlled trials on the use of kyphoplasty and vertebroplasty in the treatment of these fractures have been published, but no definitive conclusions have been reached on the role of these interventions. The major problem encountered when trying to perform a meta-analysis of the available studies for the use of cementoplasty in patients with a VCF is that conservative management has not been standardised. Forms of conservative treatment commonly used in these patients include bed rest, analgesic medication, physiotherapy and bracing.

In this review, we report the best evidence available on the conservative care of patients with osteoporotic VCFs and associated back pain, focusing on the role of the most commonly used spinal orthoses. Although orthoses are used for the management of these patients, to date, there has been only one randomised controlled trial published evaluating their value. Until the best conservative management for patients with VCFs is defined and standardised, no conclusions can be drawn on the superiority or otherwise of cementoplasty techniques over conservative management.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 577 - 583
1 May 2012
Smith CD Guyver P Bunker TD

The outcome of an anatomical shoulder replacement depends on an intact rotator cuff. In 1981 Grammont designed a novel large-head reverse shoulder replacement for patients with cuff deficiency. Such has been the success of this replacement that it has led to a rapid expansion of the indications. We performed a systematic review of the literature to evaluate the functional outcome of each indication for the reverse shoulder replacement. Secondary outcome measures of range of movement, pain scores and complication rates are also presented.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 276 - 280
1 Feb 2012
Buijze GA Weening AA Poolman RW Bhandari M Ring D

Using inaccurate quotations can propagate misleading information, which might affect the management of patients. The aim of this study was to determine the predictors of quotation inaccuracy in the peer-reviewed orthopaedic literature related to the scaphoid. We randomly selected 100 papers from ten orthopaedic journals. All references were retrieved in full text when available or otherwise excluded. Two observers independently rated all quotations from the selected papers by comparing the claims made by the authors with the data and expressed opinions of the reference source. A statistical analysis determined which article-related factors were predictors of quotation inaccuracy. The mean total inaccuracy rate of the 3840 verified quotes was 7.6%. There was no correlation between the rate of inaccuracy and the impact factor of the journal. Multivariable analysis identified the journal and the type of study (clinical, biomechanical, methodological, case report or review) as important predictors of the total quotation inaccuracy rate.

We concluded that inaccurate quotations in the peer-reviewed orthopaedic literature related to the scaphoid were common and slightly more so for certain journals and certain study types. Authors, reviewers and editorial staff play an important role in reducing this inaccuracy.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1188 - 1196
1 Sep 2007
Hobby J Griffin D Dunbar M Boileau P

A systematic search of the literature published between January 1985 and February 2006 identified 62 studies which reported the results of arthroscopic procedures for chronic anterior shoulder instability or comparisons between arthroscopic and open surgery. These studies were classified by surgical technique and research methodology, and when appropriate, were included in a meta-analysis.

The failure rate of arthroscopic shoulder stabilisation using staples or transglenoid suture techniques appeared to be significantly higher than that of either open surgery or arthroscopic stabilisation using suture anchors or bio-absorbable tacks. Arthroscopic anterior stabilisation using the most effective techniques has a similar rate of failure to open stabilisation after two years.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 549 - 555
1 Apr 2012
Lefaivre KA Slobogean GP Valeriote J O’Brien PJ Macadam SA

We performed a systematic review of the literature to evaluate the use and interpretation of generic and disease-specific functional outcome instruments in the reporting of outcome after the surgical treatment of disruptions of the pelvic ring. A total of 28 papers met our inclusion criteria, with eight reporting only generic outcome instruments, 13 reporting only pelvis-specific outcome instruments, and six reporting both. The Short-Form 36 (SF-36) was by far the most commonly used generic outcome instrument, used in 12 papers, with widely variable reporting of scores. The pelvis-specific outcome instruments were used in 19 studies; the Majeed score in ten, Iowa pelvic score in six, Hannover pelvic score in two and the Orlando pelvic score in one. Four sets of authors, all testing construct validity based on correlation with the SF-36, performed psychometric testing of three pelvis-specific instruments (Majeed, IPS and Orlando scores). No testing of responsiveness, content validity, criterion validity, internal consistency or reproducibility was performed.

The existing literature in this area is inadequate to inform surgeons or patients in a meaningful way about the functional outcomes of these fractures after fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1154 - 1159
1 Sep 2011
Parsons NR Hiskens R Price CL Achten J Costa ML

The poor reporting and use of statistical methods in orthopaedic papers has been widely discussed by both clinicians and statisticians. A detailed review of research published in general orthopaedic journals was undertaken to assess the quality of experimental design, statistical analysis and reporting. A representative sample of 100 papers was assessed for compliance to CONSORT and STROBE guidelines and the quality of the statistical reporting was assessed using a validated questionnaire. Overall compliance with CONSORT and STROBE guidelines in our study was 59% and 58% respectively, with very few papers fulfilling all criteria. In 37% of papers patient numbers were inadequately reported; 20% of papers introduced new statistical methods in the ‘results’ section not previously reported in the ‘methods’ section, and 23% of papers reported no measurement of error with the main outcome measure. Taken together, these issues indicate a general lack of statistical rigour and are consistent with similar reviews undertaken in a number of other scientific and clinical research disciplines. It is imperative that the orthopaedic research community strives to improve the quality of reporting; a failure to do so could seriously limit the development of future research.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 113 - 121
1 Jan 2012
Poultsides LA Gonzalez Della Valle A Memtsoudis SG Ma Y Roberts T Sharrock N Salvati E

We performed a meta-analysis of modern total joint replacement (TJR) to determine the post-operative mortality and the cause of death using different thromboprophylactic regimens as follows: 1) no routine chemothromboprophylaxis (NRC); 2) Potent anticoagulation (PA) (unfractionated or low-molecular-weight heparin, ximelagatran, fondaparinux or rivaroxaban); 3) Potent anticoagulation combined (PAC) with regional anaesthesia and/or pneumatic compression devices (PCDs); 4) Warfarin (W); 5) Warfarin combined (WAC) with regional anaesthesia and/or PCD; and 6) Multimodal (MM) prophylaxis, including regional anaesthesia, PCDs and aspirin in low-risk patients. Cause of death was classified as autopsy proven, clinically certain or unknown. Deaths were grouped into cardiopulmonary excluding pulmonary embolism (PE), PE, bleeding-related, gastrointestinal, central nervous system, and others (miscellaneous). Meta-analysis based on fixed effects or random effects models was used for pooling incidence data.

In all, 70 studies were included (99 441 patients; 373 deaths). The mortality was lowest in the MM (0.2%) and WC (0.2%) groups. The most frequent cause of death was cardiopulmonary (47.9%), followed by PE (25.4%) and bleeding (8.9%). The proportion of deaths due to PE was not significantly affected by the thromboprophylaxis regimen (PA, 35.5%; PAC, 28%; MM, 23.2%; and NRC, 16.3%). Fatal bleeding was higher in groups relying on the use of anticoagulation (W, 33.8%; PA, 9.4%; PAC, 10.8%) but the differences were not statistically significant.

Our study demonstrated that the routine use of PA does not reduce the overall mortality or the proportion of deaths due to PE.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 293 - 297
1 Mar 2011
Labek G Thaler M Janda W Agreiter M Stöckl B

In a systematic review, reports from national registers and clinical studies were identified and analysed with respect to revision rates after joint replacement, which were calculated as revisions per 100 observed component years.

After primary hip replacement, a mean of 1.29 revisions per 100 observed component years was seen. The results after primary total knee replacement are 1.26 revisions per 100 observed component years, and 1.53 after medial unicompartmental replacement. After total ankle replacement a mean of 3.29 revisions per 100 observed component years was seen.

The outcomes of total hip and knee replacement are almost identical. Revision rates of about 6% after five years and 12% after ten years are to be expected.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 2 - 9
1 Jan 2005
Giannoudis PV Grotz MRW Papakostidis C Dinopoulos H

Over the past 40 years, the management of displaced fractures of the acetabulum has changed from conservative to operative. We have undertaken a meta-analysis to evaluate the classification, the incidence of complications and the functional outcome of patients who had undergone operative treatment of such injuries.

We analysed a total of 3670 fractures. The most common long-term complication was osteoarthritis which occurred in approximately 20% of the patients. Other late complications, including heterotopic ossification and avascular necrosis of the femoral head, were present in less than 10%. However, only 8% of patients who were treated surgically needed a further operation, usually a hip arthroplasty, and between 75% and 80% of patients gained an excellent or good result at a mean of five years after injury. Factors influencing the functional outcome included the type of fracture and/or dislocation, damage to the femoral head, associated injuries and co-morbidity which can be considered to be non-controllable, and the timing of the operation, the surgical approach, the quality of reduction and local complications which are all controllable. The treatment of these injuries is challenging. Tertiary referrals need to be undertaken as early as possible, since the timing of surgery is of the utmost importance. It is important, at operation, to obtain the most accurate reduction of the fracture which is possible, with a minimal surgical approach, as both are related to improved outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 289 - 292
1 Feb 2010
Lewis JRP Gibson PH

The management of joint replacement in lysosomal storage diseases has not been well reported. We present three patients with progressive degenerative changes of the hips who required bilateral total hip replacement in early childhood. The stature of the patients make it essential to have access to appropriately scaled prostheses. Consideration has to be given to associated disorders of the skeleton which must be carefully screened to ensure safety in providing appropriate anaesthesia as well as ensuring that there is no cardiac abnormality. In one patient, a periprosthetic fracture was sustained in one hip in the early post-operative course requiring internal fixation.

The patient made a full recovery and all six hips were clinically and radiologically satisfactory at mid-term review.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 39 - 46
1 Jan 2011
Sukeik M Alshryda S Haddad FS Mason JM

We report a systematic review and meta-analysis of published randomised controlled trials evaluating the efficacy of tranexamic acid (TXA) in reducing blood loss and transfusion in total hip replacement (THR). The data were evaluated using the generic evaluation tool designed by the Cochrane Bone, Joint and Muscle Trauma Group. We identified 11 clinical trials which were suitable for detailed extraction of data. There were no trials that used TXA in revision THR. A total of seven studies (comprising 350 patients) were eligible for the blood loss outcome data. The use of TXA reduced intra-operative blood loss by a mean of 104 ml (95% confidence interval (CI) −164 to −44, p = 0.0006, heterogeneity I2 0%), postoperative blood loss by a mean of 172 ml (95% CI −263 to −81, p = 0.0002, heterogeneity I2 63%) and total blood loss by a mean of 289 ml (95% CI −440 to −138, p < 0.0002, heterogeneity I2 54%).

TXA led to a significant reduction in the proportion of patients requiring allogeneic blood transfusion (risk difference −0.20, 95% CI −0.29 to −0.11, p < 0.00001, I2 15%). There were no significant differences in deep-vein thrombosis, pulmonary embolism, infection rates or other complications among the study groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 851 - 854
1 Jul 2009
Timperley AJ Whitehouse SL

Recently the National Patient Safety Agency in the United Kingdom published a report entitled “Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur”. A total of 26 deaths had been reported to them when cement was used at hemiarthroplasty between October 2003 and October 2008. This paper considers the evidence for using cement fixation of a hemiarthroplasty in the treatment of hip fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1267 - 1273
1 Oct 2009
Queally JM Abdulkarim A Mulhall KJ

Neurological conditions affecting the hip pose a considerable challenge in replacement surgery since poor and imbalanced muscle tone predisposes to dislocation and loosening. Consequently, total hip replacement (THR) is rarely performed in such patients. In a systematic review of the literature concerning THR in neurological conditions, we found only 13 studies which described the outcome. We have reviewed the evidence and discussed the technical challenges of this procedure in patients with cerebral palsy, Parkinson’s disease, poliomyelitis and following a cerebrovascular accident, spinal injury or development of a Charcot joint. Contrary to traditional perceptions, THR can give a good outcome in these often severly disabled patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 987 - 996
1 Aug 2009
Alsousou J Thompson M Hulley P Noble A Willett K

Although mechanical stabilisation has been a hallmark of orthopaedic surgical management, orthobiologics are now playing an increasing role. Platelet-rich plasma (PRP) is a volume of plasma fraction of autologous blood having platelet concentrations above baseline. The platelet α granules are rich in growth factors that play an essential role in tissue healing, such as transforming growth factor-β, vascular endothelial growth factor, and platelet-derived growth factor. PRP is used in various surgical fields to enhance bone and soft-tissue healing by placing supraphysiological concentrations of autologous platelets at the site of tissue damage. The easily obtainable PRP and its possible beneficial outcome hold promise for new regenerative treatment approaches.

The aim of this literature review was to describe the bioactivities of PRP, to elucidate the different techniques for PRP preparation, to review animal and human studies, to evaluate the evidence regarding the use of PRP in trauma and orthopaedic surgery, to clarify risks, and to provide guidance for future research.