An algorithm to determine the constitutional alignment of the lower limb once arthritic deformity has occurred would be of value when undertaking kinematically aligned total knee arthroplasty (TKA). The purpose of this study was to determine if the arithmetic hip-knee-ankle angle (aHKA) algorithm could estimate the constitutional alignment of the lower limb following development of significant arthritis. A matched-pairs radiological study was undertaken comparing the aHKA of an osteoarthritic knee (aHKA-OA) with the mechanical HKA of the contralateral normal knee (mHKA-N). Patients with Grade 3 or 4 Kellgren-Lawrence tibiofemoral osteoarthritis in an arthritic knee undergoing TKA and Grade 0 or 1 osteoarthritis in the contralateral normal knee were included. The aHKA algorithm subtracts the lateral distal femoral angle (LDFA) from the medial proximal tibial angle (MPTA) measured on standing long leg radiographs. The primary outcome was the mean of the paired differences in the aHKA-OA and mHKA-N. Secondary outcomes included comparison of sex-based differences and capacity of the aHKA to determine the constitutional alignment based on degree of deformity.Aims
Methods
The purpose of this study was to compare the radiological outcomes of manual versus robotic-assisted medial unicompartmental knee arthroplasty (UKA). Postoperative radiological outcomes from 86 consecutive robotic-assisted UKAs (RAUKA group) from a single academic centre were retrospectively reviewed and compared to 253 manual UKAs (MUKA group) drawn from a prior study at our institution. Femoral coronal and sagittal angles (FCA, FSA), tibial coronal and sagittal angles (TCA, TSA), and implant overhang were radiologically measured to identify outliers.Aims
Methods
This study explored the relationship between the initial stability of the femoral component and penetration of cement into the graft bed following impaction allografting. Impaction allografting was carried out in human cadaveric femurs. In one group the cement was pressurised conventionally but in the other it was not pressurised. Migration and micromotion of the implant were measured under simulated walking loads. The specimens were then cross-sectioned and penetration of the cement measured. Around the distal half of the implant we found approximately 70% and 40% of contact of the cement with the endosteum in the pressure and no-pressure groups, respectively. The distal migration/micromotion, and
We report the outcome of 32 patients (37 knees) who underwent hemicallostasis with a dynamic external fixator for osteoarthritis of the medial compartment of the knee. There were 16 men (19 knees) and 16 women (18 knees) with a mean age at operation of 54.6 years (27 to 72). The aim was to achieve a
We present the results of 17 children of Tanner stage 1 or 2 who underwent reconstruction of the anterior cruciate ligament between 1999 and 2006 using a transphyseal procedure, employing an ipsilateral four-strand hamstring graft. The mean age of the children was 12.1 years (9.5 to 14). The mean follow-up was 44 months (25 to 100). Survival of the graft, the functional outcome and complications were recorded. There was one re-rupture following another injury. Of the remaining patients, all had good or excellent results and a normal International Knee Documentation Committee score. The mean post-operative Lysholm score was 97.5 (. sd. 2.6) and the mean Tegner activity scale was 7.9 (. sd. 1.4). One patient had a mild
Twenty patients underwent simultaneous bilateral medial unicompartmental knee arthroplasty. Pre-operative hip-knee-ankle alignment and
We have carried out a radiostereometric study of 50 patients (54 knees) with osteoarthritis of the knee who were randomly allocated to receive a cemented or a hydroxyapatite-coated femoral component for total knee replacement. The patients were also stratified to receive one of three types of articulating surface (standard, rotating platform, Freeman-Samuelson (FS)1000) all based on the Freeman-Samuelson design. The tibial components were cemented in all cases. Radiostereometry was performed post-operatively and at 3, 12 and 24 months. The analysis was restricted to rotation of the femoral component over time. After two years, rotation of the femoral components in the transverse, longitudinal and sagittal planes did not differ between the cemented and the hydroxyapatite-coated implants (p = 0.2 to 0.9). In total knee replacements with a rotating platform, the femoral component tended to tilt more posteriorly than in the other two designs, regardless of the choice of fixation (cemented or hydroxyapatite-coated, p = 0.04). The standard version of the femoral component, whether cemented or hydroxyapatite-coated, rotated more into
We have carried out a retrospective review of 20 patients with segmental fractures of the tibia who had been treated by circular external fixation. We describe the heterogeneity of these fractures, their association with multiple injuries and the need for multilevel stability with the least compromise of the biology of the fracture segments. The assessment of outcome included union, complications, the measurement of the functional IOWA knee and ankle scores and the general health status (Short-form 36). The mean time to union was 21.7 weeks (12.8 to 31), with no difference being observed between proximal and distal levels of fracture. Complications were encountered in four patients. Two had nonunion at the distal level, one a wire-related infection which required further surgery and another shortening of 15 mm with 8° of
The direct anterior (DA) approach has been associated with rapid patient recovery after total hip arthroplasty (THA) but may be associated with more frequent femoral complications including implant loosening. The objective of this study was to determine whether the addition of a collar to the femoral stem affects implant migration, patient activity, and patient function following primary THA using the DA approach. Patients were randomized to either a collared (n = 23) or collarless (n = 26) cementless femoral stem implanted using the DA approach. Canal fill ratio (CFR) was measured on the first postoperative radiographs. Patients underwent a supine radiostereometric analysis (RSA) exam postoperatively on the day of surgery and at two, four, six, 12, 26, and 52 weeks postoperatively. Patient-reported outcome measures (Western Ontario and McMaster Universities Osteoarthritis (WOMAC) Index, the 12-item Short Form Health Survey Mental and Physical Score, and University of California, Los Angeles (UCLA) Activity Score) were measured preoperatively and at each post-surgery clinic visit. Activity and function were also measured as the weekly average step count recorded by an activity tracker, and an instrumented timed up-and-go (TUG) test in clinic, respectively.Aims
Methods
Intertrochanteric osteotomy may postpone the need for total hip replacement (THR). In young patients with an acquired deformity of the femoral head and secondary osteoarthritis, a
Despite advances in the treatment of paediatric hip disease, adolescent and young adult patients can develop early onset end-stage osteoarthritis. The aims of this study were to address the indications and medium-term outcomes for total hip arthroplasty (THA) with ceramic bearings for teenage patients. Surgery was performed by a single surgeon working in the paediatric orthopaedic unit of a tertiary referral hospital. Databases were interrogated from 2003 to 2017 for all teenage patients undergoing THA with a minimum 2.3 year follow-up. Data capture included patient demographics, the underlying hip pathology, number of previous surgeries, and THA prostheses used. Institutional ethical approval was granted to contact patients for prospective clinical outcomes and obtain up-to-date radiographs. In total, 60 primary hips were implanted in 51 patients (35 female, 16 male) with nine bilateral cases. The mean age was 16.7 years (12 to 19) and mean follow-up was 9.3 years (2.3 to 16.8).Aims
Methods
The long-term success of total knee replacement is multifactorial, including factors relating to the patient, the operation and the implant. The purpose of this study was to examine the 20-year survival of the cemented Anatomical Graduated Component (AGC) total knee replacement. Between 1983 and 2004, 7760 of these were carried out at our institution. Of these, 6726 knees which received the non-modular metal-backed tibial component with compression-moulded polyethylene and had a minimum two-year follow-up were available for study. In all, 36 knees were followed over 20 years with a survival of the tibial and femoral components together of 97.8% (95% confidence interval (CI) 0.9851 to 0.9677), with no implants being revised for polyethylene wear or osteolysis. Age >
70 was associated with increased survival (99.6%, 95% CI 99.0 to 99.8) (p <
0.0001) but pre-operative
Vitamin E-infused highly cross-linked polyethylene (E1) has recently been introduced in total knee arthroplasty (TKA). An in vitro wear simulator study showed that E1 reduced polyethylene wear. However there is no published information regarding in vivo wear. Previous reports suggest that newly introduced materials which reduce in vitro polyethylene wear do not necessarily reduce in vivo polyethylene wear. To assist in the evaluation of the newly introduced material before widespread use, we established an in vivo polyethylene wear particle analysis for TKA. The aim of this study was to compare in vivo polyethylene wear particle generation between E1 and conventional polyethylene (ArCom) in TKA. A total of 34 knees undergoing TKA (17 each with ArCom or E1) were investigated. Except for the polyethylene insert material, the prostheses used for both groups were identical. Synovial fluid was obtained at a mean of 3.4 years (SD 1.3) postoperatively. The in vivo polyethylene wear particles were isolated from the synovial fluid using a previously validated method and examined by scanning electron microscopy.Aims
Methods
The aims of this study is to report the clinical and radiological outcomes after pre-, central-, and postaxial polydactyly resection in children from a tertiary referral centre. All children who underwent resection of a supernumerary toe between 2001 and 2013 were prospectively enrolled and invited for a single re-assessment. Clinical parameters and several dedicated outcome scores (visual analogue scale (VAS), Paediatric Outcomes Data Collection Instrument (PODCI), Activities Scale for Kids (ASK), and American Orthopaedic Foot and Ankle Society Score (AOFAS)) were obtained, as were radiographs of the operated and non-operated feet along with pedobarographs.Aims
Methods
Premature epiphysial fusion is a common complication of injury of the capitulum in childhood and sometimes results in
The treatment of tibial aplasia is controversial. Amputation represents the gold standard with good functional results, but is frequently refused by the families. In these patients, treatment with reconstructive limb salvage can be considered. Due to the complexity of the deformity, this remains challenging and should be staged. The present study evaluated the role of femoro-pedal distraction using a circular external fixator in reconstructive treatment of tibial aplasia. The purpose of femoro-pedal distraction is to realign the limb and achieve soft tissue lengthening to allow subsequent reconstructive surgery. This was a retrospective study involving ten patients (12 limbs) with tibial aplasia, who underwent staged reconstruction. During the first operation a circular hexapod external fixator was applied and femoro-pedal distraction was undertaken over several months. Subsequent surgery included reconstruction of the knee joint and alignment of the foot.Aims
Methods
No randomized comparative study has compared the extensile lateral approach (ELA) and sinus tarsi approach (STA) for Sanders type 2 calcaneal fractures. This randomized comparative study was conducted to confirm whether the STA was prone to fewer wound complications than the ELA. Between August 2013 and August 2018, 64 patients with Sanders type 2 calcaneus fractures were randomly assigned to receive surgical treatment by the ELA (32 patients) and STA (32 patients). The primary outcome was development of wound complications. The secondary outcomes were postoperative complications, pain scored of a visual analogue scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS) score, 36-item Short Form health survey, operative duration, subtalar joint range of motion (ROM), Böhler’s angle and calcaneal width, and posterior facet reduction.Aims
Methods
The object of this study was to develop a method to assess the accuracy of an image-free total knee replacement navigation system in legs with normal or abnormal mechanical axes. A phantom leg was constructed with simulated hip and knee joints and provided a means to locate the centre of the ankle joint. Additional joints located at the midshaft of the tibia and femur allowed deformation in the flexion/extension, varus/