Advertisement for orthosearch.org.uk
Results 241 - 260 of 346
Results per page:
Bone & Joint Research
Vol. 3, Issue 1 | Pages 14 - 19
1 Jan 2014
James SJ Mirza SB Culliford DJ Taylor PA Carr AJ Arden NK

Aims

Osteoporosis and abnormal bone metabolism may prove to be significant factors influencing the outcome of arthroplasty surgery, predisposing to complications of aseptic loosening and peri-prosthetic fracture. We aimed to investigate baseline bone mineral density (BMD) and bone turnover in patients about to undergo arthroplasty of the hip and knee.

Methods

We prospectively measured bone mineral density of the hip and lumbar spine using dual-energy X-ray absorptiometry (DEXA) scans in a cohort of 194 patients awaiting hip or knee arthroplasty. We also assessed bone turnover using urinary deoxypyridinoline (DPD), a type I collagen crosslink, normalised to creatinine.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 57 - 62
1 Nov 2013
Stulberg SD Patel RM

Conventional uncemented femoral implants provide dependable long-term fixation in patients with a wide range of functional requirements. Yet challenges associated with proximal–distal femoral dimensional mismatch, preservation of bone stock, and minimally invasive approaches have led to exploration into alternative implant designs. Short stem designs focusing on a stable metaphyseal fit have emerged to address these issues in total hip replacement (THR). Uncemented metaphyseal-engaging short stem implants are stable and are associated with proximal bone remodeling closer to the metaphysis when compared with conventional stems and they also have comparable clinical performances. Short stem metaphyseal-engaging implants can meet the goals of a successful THR, including tolerating a high level of patient function, as well as durable fixation.

Cite this article: Bone Joint J 2013;95-B, Supple A:57–62.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1239 - 1243
1 Sep 2014
Zafra M Uceda P Flores M Carpintero P

Patients with pain and loss of shoulder function due to nonunion of a fracture of the proximal third of the humerus may benefit from reverse total shoulder replacement. This paper reports a prospective, multicentre study, involving three hospitals and three surgeons, of 35 patients (28 women, seven men) with a mean age of 69 years (46 to 83) who underwent a reverse total shoulder replacement for the treatment of nonunion of a fracture of the proximal humerus. Using Checchia’s classification, nine nonunions were type I, eight as type II, 12 as type III and six as type IV. The mean follow-up was 51 months (24 to 99). Post-operatively, the patients had a significant decrease in pain (p < 0.001), and a significant improvement in flexion, abduction, external rotation and Constant score (p < 0.001), but not in internal rotation. A total of nine complications were recorded in seven patients: six dislocations, one glenoid loosening in a patient who had previously suffered dislocation, one transitory paresis of the axillary nerve and one infection.

Reverse total shoulder replacement may lead to a significant reduction in pain, improvement in function and a high degree of satisfaction. However, the rate of complications, particularly dislocation, was high.

Cite this article: Bone Joint J 2014;96-B:1239–43.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 956 - 962
1 Jul 2014
Ahearn N Oppy A Halliday R Rowett-Harris J Morris SA Chesser TJ Livingstone JA

Unstable bicondylar tibial plateau fractures are rare and there is little guidance in the literature as to the best form of treatment. We examined the short- to medium-term outcome of this injury in a consecutive series of patients presenting to two trauma centres. Between December 2005 and May 2010, a total of 55 fractures in 54 patients were treated by fixation, 34 with peri-articular locking plates and 21 with limited access direct internal fixation in combination with circular external fixation using a Taylor Spatial Frame (TSF). At a minimum of one year post-operatively, patient-reported outcome measures including the WOMAC index and SF-36 scores showed functional deficits, although there was no significant difference between the two forms of treatment. Despite low outcome scores, patients were generally satisfied with the outcome. We achieved good clinical and radiological outcomes, with low rates of complication. In total, only three patients (5%) had collapse of the joint of > 4 mm, and metaphysis to diaphysis angulation of greater than 5º, and five patients (9%) with displacement of > 4 mm. All patients in our study went on to achieve full union.

This study highlights the serious nature of this injury and generally poor patient-reported outcome measures following surgery, despite treatment by experienced surgeons using modern surgical techniques. Our findings suggest that treatment of complex bicondylar tibial plateau fractures with either a locking plate or a TSF gives similar clinical and radiological outcomes.

Cite this article: Bone Joint J 2014;96-B:956–62.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 530 - 534
1 Apr 2014
Gallucci GL Piuzzi NS Slullitel PAI Boretto JG Alfie VA Donndorff A De Carli P

We retrospectively evaluated the clinical and radiological outcomes of a consecutive cohort of patients aged > 70 years with a displaced fracture of the olecranon, which was treated non-operatively with early mobilisation. We identified 28 such patients (27 women) with a mean age of 82 years (71 to 91). The elbow was initially immobilised in an above elbow cast in 90° of flexion of the elbow for a mean of five days. The cast was then replaced by a sling. Active mobilisation was encouraged as tolerated. No formal rehabilitation was undertaken. At a mean follow-up of 16 months (12 to 26), the mean ranges of flexion and extension were 140° and 15° respectively. On a visual analogue scale of 1 (no pain) to 10, the mean pain score was 1 (0 to 8). Of the original 28 patients 22 developed nonunion, but no patients required surgical treatment.

We conclude that non-operative functional treatment of displaced olecranon fractures in the elderly gives good results and a high rate of satisfaction.

Cite this article: Bone Joint J 2014;96-B:530–4.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 519 - 525
1 Apr 2014
Rasmussen JV Polk A Sorensen AK Olsen BS Brorson S

In this study, we evaluated patient-reported outcomes, the rate of revision and the indications for revision following resurfacing hemiarthroplasty of the shoulder in patients with osteoarthritis.

All patients with osteoarthritis who underwent primary resurfacing hemiarthroplasty and reported to the Danish Shoulder Arthroplasty Registry (DSR), between January 2006 and December 2010 were included. There were 772 patients (837 arthroplasties) in the study. The Western Ontario Osteoarthritis of the Shoulder (WOOS) index was used to evaluate patient-reported outcome 12 months (10 to 14) post-operatively. The rates of revision were calculated from the revisions reported to the DSR up to December 2011 and by checking deaths with the Danish National Register of Persons.

A complete questionnaire was returned by 688 patients (82.2%). The mean WOOS was 67 (0 to 100). A total of 63 hemiarthroplasties (7.5%) required revision; the cumulative five-year rate of revision was 9.9%. Patients aged < 55 years had a statistically significant inferior WOOS score, which exceeded the minimal clinically important difference, compared with older patients (mean difference 14.2 (8.8; 95% CI 19.6; p < 0.001), but with no increased risk of revision. There was no significant difference in the mean WOOS or the risk of revision between designs of resurfacing hemiarthroplasty.

Cite this article: Bone Joint J 2014;96-B:519–25.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 319 - 324
1 Mar 2014
Abolghasemian M Sadeghi Naini M Tangsataporn S Lee P Backstein D Safir O Kuzyk P Gross AE

We retrospectively reviewed 44 consecutive patients (50 hips) who underwent acetabular re-revision after a failed previous revision that had been performed using structural or morcellised allograft bone, with a cage or ring for uncontained defects. Of the 50 previous revisions, 41 cages and nine rings were used with allografts for 14 minor-column and 36 major-column defects. We routinely assessed the size of the acetabular bone defect at the time of revision and re-revision surgery. This allowed us to assess whether host bone stock was restored. We also assessed the outcome of re-revision surgery in these circumstances by means of radiological characteristics, rates of failure and modes of failure. We subsequently investigated the factors that may affect the potential for the restoration of bone stock and the durability of the re-revision reconstruction using multivariate analysis.

At the time of re-revision, there were ten host acetabula with no significant defects, 14 with contained defects, nine with minor-column, seven with major-column defects and ten with pelvic discontinuity. When bone defects at re-revision were compared with those at the previous revision, there was restoration of bone stock in 31 hips, deterioration of bone stock in nine and remained unchanged in ten. This was a significant improvement (p <  0.001). Morselised allografting at the index revision was not associated with the restoration of bone stock.

In 17 hips (34%), re-revision was possible using a simple acetabular component without allograft, augments, rings or cages. There were 47 patients with a mean follow-up of 70 months (6 to 146) available for survival analysis. Within this group, the successful cases had a minimum follow-up of two years after re-revision. There were 22 clinical or radiological failures (46.7%), 18 of which were due to aseptic loosening. The five and ten year Kaplan–Meier survival rate was 75% (95% CI, 60 to 86) and 56% (95% CI, 40 to 70) respectively with aseptic loosening as the endpoint. The rate of aseptic loosening was higher for hips with pelvic discontinuity (p = 0.049) and less when the allograft had been in place for longer periods (p = 0.040).

The use of a cage or ring over structural allograft bone for massive uncontained defects in acetabular revision can restore host bone stock and facilitate subsequent re-revision surgery to a certain extent.

Cite this article: Bone Joint J 2014;96-B:319–24.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 536 - 542
1 Apr 2013
Puchwein P Jester B Freytag B Tanzer K Maizen C Gumpert R Pichler W

Ventral screw osteosynthesis is a common surgical method for treating fractures of the odontoid peg, but there is still no consensus about the number and diameter of the screws to be used. The purpose of this study was to develop a more accurate measurement technique for the morphometry of the odontoid peg (dens axis) and to provide a recommendation for ventral screw osteosynthesis.

Images of the cervical spine of 44 Caucasian patients, taken with a 64-line CT scanner, were evaluated using the measuring software MIMICS. All measurements were performed by two independent observers. Intraclass correlation coefficients were used to measure inter-rater variability.

The mean length of the odontoid peg was 39.76 mm (sd 2.68). The mean screw entry angle α was 59.45° (sd 3.45). The mean angle between the screw and the ventral border of C2 was 13.18° (sd 2.70), the maximum possible mean converging angle of two screws was 20.35° (sd 3.24). The measurements were obtained at the level of 66% of the total odontoid peg length and showed mean values of 8.36 mm (sd 0.84) for the inner diameter in the sagittal plane and 7.35 mm (sd 0.97) in the coronal plane. The mean outer diameter of the odontoid peg was 12.88 mm (sd 0.91) in the sagittal plane and 11.77 mm (sd 1.09) in the coronal plane. The results measured at the level of 90% of the total odontoid peg length were a mean of 6.12 mm (sd 1.14) for the sagittal inner diameter and 5.50 mm (sd 1.05) for the coronal inner diameter. The mean outer diameter of the odontoid peg was 11.10 mm (sd 1.0) in the sagittal plane and 10.00 mm (sd 1.07) in the coronal plane. In order to calculate the necessary screw length using 3.5 mm cannulated screws, 1.5 mm should be added to the measured odontoid peg length when anatomical reduction seems possible.

The cross-section of the odontoid peg is not circular but slightly elliptical, with a 10% greater diameter in the sagittal plane. In the majority of cases (70.5%) the odontoid peg offers enough room for two 3.5 mm cannulated cortical screws.

Cite this article: Bone Joint J 2013;95-B:536–42.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 249 - 253
1 Feb 2014
Euler SA Hengg C Kolp D Wambacher M Kralinger F

Antegrade nailing of proximal humeral fractures using a straight nail can damage the bony insertion of the supraspinatus tendon and may lead to varus failure of the construct. In order to establish the ideal anatomical landmarks for insertion of the nail and their clinical relevance we analysed CT scans of bilateral proximal humeri in 200 patients (mean age 45.1 years (sd 19.6; 18 to 97) without humeral fractures. The entry point of the nail was defined by the point of intersection of the anteroposterior and lateral vertical axes with the cortex of the humeral head. The critical point was defined as the intersection of the sagittal axis with the medial limit of the insertion of the supraspinatus tendon on the greater tuberosity. The region of interest, i.e. the biggest entry hole that would not encroach on the insertion of the supraspinatus tendon, was calculated setting a 3 mm minimal distance from the critical point. This identified that 38.5% of the humeral heads were categorised as ‘critical types’, due to morphology in which the predicted offset of the entry point would encroach on the insertion of the supraspinatus tendon that may damage the tendon and reduce the stability of fixation.

We therefore emphasise the need for ‘fastidious’ pre-operative planning to minimise this risk.

Cite this article: Bone Joint J 2014;96-B:249–53.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1160 - 1169
1 Sep 2012
Bohm ER Tufescu TV Marsh JP

This review considers the surgical treatment of displaced fractures involving the knee in elderly, osteoporotic patients. The goals of treatment include pain control, early mobilisation, avoidance of complications and minimising the need for further surgery. Open reduction and internal fixation (ORIF) frequently results in loss of reduction, which can result in post-traumatic arthritis and the occasional conversion to total knee replacement (TKR). TKR after failed internal fixation is challenging, with modest functional outcomes and high complication rates. TKR undertaken as treatment of the initial fracture has better results to late TKR, but does not match the outcome of primary TKR without complications. Given the relatively infrequent need for late TKR following failed fixation, ORIF is the preferred management for most cases. Early TKR can be considered for those patients with pre-existing arthritis, bicondylar femoral fractures, those who would be unable to comply with weight-bearing restrictions, or where a single definitive procedure is required.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 95 - 97
1 Nov 2013
Cross MB Paprosky WG

If a surgeon is faced with altered lesser trochanter anatomy when revising the femoral component in revision total hip replacement, a peri-prosthetic fracture, or Paprosky type IIIb or type IV femoral bone loss, a modular tapered stem offers the advantages of accurately controlling femoral version and length. The splines of the taper allow rotational control, and improve the fit in femoral canals with diaphyseal bone loss. In general, two centimetres of diaphyseal contact is all that is needed to gain stability with modular tapered stems. By allowing the proximal body trial to rotate on a well-fixed distal segment during trial reduction, appropriate anteversion can be obtained in order to improve intra-operative stability, and decrease the dislocation risk. However, modular stems should not be used for all femoral revisions, as implant fracture and corrosion at modular junctions can still occur.

Cite this article: Bone Joint J 2013;95-B, Supple A:95–7.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 51 - 52
1 Nov 2013
Murray DW

There is a North Atlantic divide, with cementless femoral stems being used more frequently in the USA and cemented stems being used more frequently in many countries in Europe. This is primarily because different cemented stems have been used on different sides of the Atlantic and the results of the cemented stems in the US have often been poor, whereas the results of the stems used in Europe have been good. In the National registers in Europe, cemented stems have tended to achieve better results than cementless.

Cite this article: Bone Joint J 2013;95-B, Supple A:51–2.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 217 - 223
1 Feb 2013
Hwang CJ Lee JH Baek H Chang B Lee C

We evaluated the efficacy of Escherichia coli-derived recombinant human bone morphogenetic protein-2 (E-BMP-2) in a mini-pig model of spinal anterior interbody fusion. A total of 14 male mini-pigs underwent three-level anterior lumbar interbody fusion using polyether etherketone (PEEK) cages containing porous hydroxyapatite (HA). Four groups of cages were prepared: 1) control (n = 10 segments); 2) 50 μg E-BMP-2 (n = 9); 3) 200 μg E-BMP-2 (n = 10); and 4) 800 μg E-BMP-2 (n = 9). At eight weeks after surgery the mini-pigs were killed and the specimens were evaluated by gross inspection and manual palpation, radiological evaluation including plain radiographs and micro-CT scans, and histological analysis. Rates of fusion within PEEK cages and overall union rates were calculated, and bone formation outside vertebrae was evaluated. One animal died post-operatively and was excluded, and one section was lost and also excluded, leaving 38 sites for assessment. This rate of fusion within cages was 30.0% (three of ten) in the control group, 44.4% (four of nine) in the 50 μg E-BMP-2 group, 60.0% (six of ten) in the 200 μg E-BMP-2 group, and 77.8% (seven of nine) in the 800 μg E-BMP-2 group. Fusion rate was significantly increased by the addition of E-BMP-2 and with increasing E-BMP-2 dose (p = 0.046). In a mini-pig spinal anterior interbody fusion model using porous HA as a carrier, the implantation of E-BMP-2-loaded PEEK cages improved the fusion rate compared with PEEK cages alone, an effect that was significantly increased with increasing E-BMP-2 dosage.

Cite this article: Bone Joint J 2013;95-B:217–23.


Bone & Joint Research
Vol. 2, Issue 12 | Pages 264 - 269
1 Dec 2013
Antoniades G Smith EJ Deakin AH Wearing SC Sarungi M

Objective

This study compared the primary stability of two commercially available acetabular components from the same manufacturer, which differ only in geometry; a hemispherical and a peripherally enhanced design (peripheral self-locking (PSL)). The objective was to determine whether altered geometry resulted in better primary stability.

Methods

Acetabular components were seated with 0.8 mm to 2 mm interference fits in reamed polyethylene bone substrate of two different densities (0.22 g/cm3 and 0.45 g/cm3). The primary stability of each component design was investigated by measuring the peak failure load during uniaxial pull-out and tangential lever-out tests.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 11 - 16
1 Nov 2013
Sierra RJ Mabry TM Sems SA Berry DJ

Total hip replacement (THR) after acetabular fracture presents unique challenges to the orthopaedic surgeon. The majority of patients can be treated with a standard THR, resulting in a very reasonable outcome. Technical challenges however include infection, residual pelvic deformity, acetabular bone loss with ununited fractures, osteonecrosis of bone fragments, retained metalwork, heterotopic ossification, dealing with the sciatic nerve, and the difficulties of obtaining long-term acetabular component fixation. Indications for an acute THR include young patients with both femoral head and acetabular involvement with severe comminution that cannot be reconstructed, and the elderly, with severe bony comminution. The outcomes of THR for established post-traumatic arthritis include excellent pain relief and functional improvements. The use of modern implants and alternative bearing surfaces should improve outcomes further.

Cite this article: Bone Joint J 2013;95-B, Supple A:11–16.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 811 - 816
1 Jun 2011
Duckworth AD Bennet SJ Aderinto J Keating JF

The aim of this study was to determine the comorbid risk factors for failure in young patients who undergo fixation of a displaced fracture of the femoral neck. We identified from a prospective database all such patients ≤ 60 years of age treated with reduction and internal fixation. The main outcome measures were union, failure of fixation, nonunion and the development of avascular necrosis.

There were 122 patients in the study. Union occurred in 83 patients (68%) at a mean follow-up of 58 months (18 to 155). Complications occurred in 39 patients (32%) at a mean of 11 months (0.5 to 39). The rate of nonunion was 7.4% (n = 9) and of avascular necrosis was 11.5% (n = 14). Failures were more common in patients over 40 years of age (p = 0.03). Univariate analysis identified that delay in time to fixation (> 24 hours), alcohol excess and pre-existing renal, liver or respiratory disease were all predictive of failure (all p < 0.05). Of these, alcohol excess, renal disease and respiratory disease were most predictive of failure on multivariate analysis.

Younger patients with fractures of the femoral neck should be carefully evaluated for comorbidities that increase the risk of failure after reduction and fixation. In patients with a history of alcohol abuse, renal or respiratory disease, arthroplasty should be considered as an alternative treatment.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 31 - 36
1 Nov 2013
Gustke K

Total hip replacement for developmental hip dysplasia is challenging. The anatomical deformities on the acetabular and femoral sides are difficult to predict. The Crowe classification is usually used to describe these cases – however, it is not a very helpful tool for pre-operative planning. Small acetabular components, acetabular augments, and modular femoral components should be available for all cases. Regardless of the Crowe classification, the surgeon must be prepared to perform a femoral osteotomy for shortening, or to correct rotation, and/or angulation.

Cite this article: Bone Joint J 2013;95-B, Supple A:31–6.


Bone & Joint Research
Vol. 2, Issue 10 | Pages 206 - 209
1 Oct 2013
Griffin XL McArthur J Achten J Parsons N Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. Controversy exists regarding the optimal treatment for patients with unstable trochanteric proximal femoral fractures. The recognised treatment alternatives are extramedullary fixation usually with a sliding hip screw and intramedullary fixation with a cephalomedullary nail. Current evidence suggests that best results and lowest complication rates occur using a sliding hip screw. Complications in these difficult fractures are relatively common regardless of type of treatment. We believe that a novel device, the X-Bolt dynamic plating system, may offer superior fixation over a sliding hip screw with lower reoperation risk and better function. We therefore propose to investigate the clinical effectiveness of the X-bolt dynamic plating system compared with standard sliding hip screw fixation within the framework of a the larger WHiTE (Warwick Hip Trauma Evaluation) Comprehensive Cohort Study.

Cite this article: Bone Joint Res 2013;2:206–9.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 114 - 119
1 Nov 2013
Whitehouse MR Duncan CP

Hip arthrodesis remains a viable surgical technique in well selected patients, typically the young manual labourer with isolated unilateral hip disease. Despite this, its popularity with patients and surgeons has decreased due to the evolution of hip replacement, and is seldom chosen by young adult patients today. The surgeon is more likely to encounter a patient who requests conversion to total hip replacement (THR). The most common indications are a painful pseudarthrosis, back pain, ipsilateral knee pain or contralateral hip pain. Occasionally the patient will request conversion because of difficulty with activities of daily living, body image and perceived cosmesis. The technique of conversion and a discussion of the results are presented.

Cite this article: Bone Joint J 2013;95-B, Supple A:114–19.


Bone & Joint 360
Vol. 2, Issue 4 | Pages 29 - 31
1 Aug 2013

The August 2013 Research Roundup360 looks at: passive smoking and bone substitutes; platelet-rich plasma and osteogenesis; plantar fasciitis and platelet-rich plasma: a match made in heaven?; MRSA decolonisation decreases infection rates; gums, bisphosphonates and orthopaedics; PRAISE and partner violence; blunt impact and post-traumatic OA; and IDEAL research and implants