Advertisement for orthosearch.org.uk
Results 241 - 260 of 379
Results per page:
Bone & Joint Research
Vol. 4, Issue 9 | Pages 154 - 162
1 Sep 2015

Objective

Clinical studies of patients with bone sarcomas have been challenged by insufficient numbers at individual centres to draw valid conclusions. Our objective was to assess the feasibility of conducting a definitive multi-centre randomised controlled trial (RCT) to determine whether a five-day regimen of post-operative antibiotics, in comparison to a 24-hour regimen, decreases surgical site infections in patients undergoing endoprosthetic reconstruction for lower extremity primary bone tumours.

Methods

We performed a pilot international multi-centre RCT. We used central randomisation to conceal treatment allocation and sham antibiotics to blind participants, surgeons, and data collectors. We determined feasibility by measuring patient enrolment, completeness of follow-up, and protocol deviations for the antibiotic regimens.


Bone & Joint 360
Vol. 5, Issue 3 | Pages 36 - 37
1 Jun 2016
Das A


Bone & Joint 360
Vol. 1, Issue 4 | Pages 36 - 36
1 Aug 2012
Carey Smith R Wood D


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1043 - 1049
1 Aug 2016
Huijbregts HJTAM Khan RJK Fick DP Hall MJ Punwar SA Sorensen E Reid MJ Vedove SD Haebich S

Aims

We conducted a randomised controlled trial to assess the accuracy of positioning and alignment of the components in total knee arthroplasty (TKA), comparing those undertaken using standard intramedullary cutting jigs and those with patient-specific instruments (PSI).

Patients and Methods

There were 64 TKAs in the standard group and 69 in the PSI group.

The post-operative hip-knee-ankle (HKA) angle and positioning was investigated using CT scans. Deviation of > 3° from the planned position was regarded as an outlier. The operating time, Oxford Knee Scores (OKS) and Short Form-12 (SF-12) scores were recorded.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 277 - 282
1 Feb 2015
Shetty RP Mathew M Smith J Morse LP Mehta JA Currie BJ

Little information is available about several important aspects of the treatment of melioidosis osteomyelitis and septic arthritis.

We undertook a retrospective review of 50 patients with these conditions in an attempt to determine the effect of location of the disease, type of surgical intervention and duration of antibiotic treatment on outcome, particularly complications and relapse.

We found that there was a 27.5% risk of osteomyelitis of the adjacent bone in patients with septic arthritis in the lower limb. Patients with septic arthritis and osteomyelitis of an adjacent bone were in hospital significantly longer (p = 0.001), needed more operations (p = 0.031) and had a significantly higher rate of complications and re-presentation (p = 0.048).

More than half the patients (61%), most particularly those with multifocal bone and joint involvement, and those with septic arthritis and osteomyelitis of an adjacent bone who were treated operatively, needed more visits to theatre.

Cite this article: Bone Joint J 2015;97-B:277–82.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 101 - 104
1 Nov 2014
Lombardi Jr AV Berend KR Adams JB

Previous studies of failure mechanisms leading to revision total knee replacement (TKR) performed between 1986 and 2000 determined that many failed early, with a disproportionate amount accounted for by infection and implant-associated factors including wear, loosening and instability. Since then, efforts have been made to improve implant performance and instruct surgeons in best practice. Recently our centre participated in a multi-centre evaluation of 844 revision TKRs from 2010 to 2011. The purpose was to report a detailed analysis of failure mechanisms over time and to see if failure modes have changed over the past 10 to 15 years. Aseptic loosening was the predominant mechanism of failure (31.2%), followed by instability (18.7%), infection (16.2%), polyethylene wear (10.0%), arthrofibrosis (6.9%) and malalignment (6.6%). The mean time to failure was 5.9 years (ten days to 31 years), 35.3% of all revisions occurred at less than two years, and 60.2% in the first five years. With improvements in implant and polyethylene manufacture, polyethylene wear is no longer a leading cause of failure. Early mechanisms of failure are primarily technical errors. In addition to improving implant longevity, industry and surgeons must work together to decrease these technical errors. All reports on failure of TKR contain patients with unexplained pain who not infrequently have unmet expectations. Surgeons must work to achieve realistic patient expectations pre-operatively, and therefore, improve patient satisfaction post-operatively.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):101–4.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1313 - 1320
1 Oct 2012
Middleton RG Shabani F Uzoigwe CE AS Moqsith M Venkatesan M

Osteoporosis is common and the health and financial cost of fragility fractures is considerable. The burden of cardiovascular disease has been reduced dramatically by identifying and targeting those most at risk. A similar approach is potentially possible in the context of fragility fractures. The World Health Organization created and endorsed the use of FRAX, a fracture risk assessment tool, which uses selected risk factors to calculate a quantitative, patient-specific, ten-year risk of sustaining a fragility fracture. Treatment can thus be based on this as well as on measured bone mineral density. It may also be used to determine at-risk individuals, who should undergo bone densitometry. FRAX has been incorporated into the national osteoporosis guidelines of countries in the Americas, Europe, the Far East and Australasia. The United Kingdom National Institute for Health and Clinical Excellence also advocates its use in their guidance on the assessment of the risk of fragility fracture, and it may become an important tool to combat the health challenges posed by fragility fractures.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 20 - 21
1 Feb 2016


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1589 - 1590
1 Dec 2015
Haddad FS


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 10 - 13
1 Jan 2016
Brooks PJ

Hip resurfacing has been proposed as an alternative to traditional total hip arthroplasty in young, active patients. Much has been learned following the introduction of metal-on-metal resurfacing devices in the 1990s. The triad of a well-designed device, implanted accurately, in the correct patient has never been more critical than with these implants.

Following Food and Drug Administration approval in 2006, we studied the safety and effectiveness of one hip resurfacing device (Birmingham Hip Resurfacing) at our hospital in a large, single-surgeon series. We report our early to mid–term results in 1333 cases followed for a mean of 4.3 years (2 to 5.7) using a prospective, observational registry. The mean patient age was 53.1 years (12 to 84); 70% were male and 91% had osteoarthritis. Complications were few, including no dislocations, no femoral component loosening, two femoral neck fractures (0.15%), one socket loosening (0.08%), three deep infections (0.23%), and three cases of metallosis (0.23%). There were no destructive pseudotumours.

Overall survivorship at up to 5.7 years was 99.2%. Aseptic survivorship in males under the age of 50 was 100%. We believe this is the largest United States series of a single surgeon using a single resurfacing system.

Cite this article: Bone Joint J 2016;98-B (1 Suppl A):10–13.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 291 - 297
1 Mar 2016
Rogmark C Leonardsson O

This review summarises the evidence for the treatment of displaced fractures of the femoral neck in elderly patients. Results from randomised clinical trials and national register studies are presented when available.

The advantages of arthroplasty compared with internal fixation are supported by several studies. A number of studies contribute to the discussions of total hip arthroplasty (THA) versus hemiarthroplasty and unipolar versus bipolar hemiarthroplasty, but no clear-cut evidence-based recommendation can be made. THA may be particularly advantageous for active, lucid patients with a relatively long life expectancy. For patients who are physiologically older, hemiarthoplasty is probably satisfactory, and for the oldest patients with more comorbidities, unipolar implants are considered to be sufficient. If the hospital can support emergency THA surgery in sufficient numbers and quality, there may be few patients who warrant bipolar hemiarthroplasty.

The direct lateral approach reduces the risk of dislocation compared with the posterior approach. Cemented implants lower the risk of periprosthetic fracture and its subsequent morbidity and mortality. As the risk of peri-operative death related to bone cement can be reduced by adequate measures, cemented implants are recommended in fracture cases.

Take home message: There remains a great variation in the surgical management of patients with a hip fracture, and an evidence-based approach should improve the outcomes for this vulnerable patient group.

Cite this article: Bone Joint J 2016;98-B:291–7.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1178 - 1184
1 Sep 2014
Tarrant SM Hardy BM Byth PL Brown TL Attia J Balogh ZJ

There is a high rate of mortality in elderly patients who sustain a fracture of the hip. We aimed to determine the rate of preventable mortality and errors during the management of these patients. A 12 month prospective study was performed on patients aged > 65 years who had sustained a fracture of the hip. This was conducted at a Level 1 Trauma Centre with no orthogeriatric service. A multidisciplinary review of the medical records by four specialists was performed to analyse errors of management and elements of preventable mortality. During 2011, there were 437 patients aged > 65 years admitted with a fracture of the hip (85 years (66 to 99)) and 20 died while in hospital (86.3 years (67 to 96)). A total of 152 errors were identified in the 80 individual reviews of the 20 deaths. A total of 99 errors (65%) were thought to have at least a moderate effect on death; 45 reviews considering death (57%) were thought to have potentially been preventable. Agreement between the panel of reviewers on the preventability of death was fair. A larger-scale assessment of preventable mortality in elderly patients who sustain a fracture of the hip is required. Multidisciplinary review panels could be considered as part of the quality assurance process in the management of these patients.

Cite this article: Bone Joint J 2014;96-B:1178–84.


Bone & Joint 360
Vol. 3, Issue 3 | Pages 16 - 18
1 Jun 2014

The June 2014 Hip & Pelvis Roundup360 looks at: Modular femoral necks: early signs are not good; is corrosion to blame for modular neck failures; metal-on-metal is not quite a closed book; no excess failures in fixation of displaced femoral neck fractures; noise no problem in hip replacement; heterotopic ossification after hip arthroscopy: are NSAIDs the answer?; thrombotic and bleeding events surprisingly low in total joint replacement; and the elephant in the room: complications and surgical volume.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 293 - 297
1 Mar 2011
Labek G Thaler M Janda W Agreiter M Stöckl B

In a systematic review, reports from national registers and clinical studies were identified and analysed with respect to revision rates after joint replacement, which were calculated as revisions per 100 observed component years.

After primary hip replacement, a mean of 1.29 revisions per 100 observed component years was seen. The results after primary total knee replacement are 1.26 revisions per 100 observed component years, and 1.53 after medial unicompartmental replacement. After total ankle replacement a mean of 3.29 revisions per 100 observed component years was seen.

The outcomes of total hip and knee replacement are almost identical. Revision rates of about 6% after five years and 12% after ten years are to be expected.


Bone & Joint Research
Vol. 5, Issue 4 | Pages 153 - 161
1 Apr 2016
Kleinlugtenbelt YV Nienhuis RW Bhandari M Goslings JC Poolman RW Scholtes VAB

Objectives

Patient-reported outcome measures (PROMs) are often used to evaluate the outcome of treatment in patients with distal radial fractures. Which PROM to select is often based on assessment of measurement properties, such as validity and reliability. Measurement properties are assessed in clinimetric studies, and results are often reviewed without considering the methodological quality of these studies. Our aim was to systematically review the methodological quality of clinimetric studies that evaluated measurement properties of PROMs used in patients with distal radial fractures, and to make recommendations for the selection of PROMs based on the level of evidence of each individual measurement property.

Methods

A systematic literature search was performed in PubMed, EMbase, CINAHL and PsycINFO databases to identify relevant clinimetric studies. Two reviewers independently assessed the methodological quality of the studies on measurement properties, using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. Level of evidence (strong / moderate / limited / lacking) for each measurement property per PROM was determined by combining the methodological quality and the results of the different clinimetric studies.


Bone & Joint Research
Vol. 2, Issue 8 | Pages 162 - 168
1 Aug 2013
Chia PH Gualano L Seevanayagam S Weinberg L

Objectives

To determine the morbidity and mortality outcomes of patients presenting with a fractured neck of femur in an Australian context. Peri-operative variables related to unfavourable outcomes were identified to allow planning of intervention strategies for improving peri-operative care.

Methods

We performed a retrospective observational study of 185 consecutive adult patients admitted to an Australian metropolitan teaching hospital with fractured neck of femur between 2009 and 2010. The main outcome measures were 30-day and one-year mortality rates, major complications and factors influencing mortality.


Bone & Joint 360
Vol. 2, Issue 4 | Pages 33 - 33
1 Aug 2013
Das A

Things have not been quiet in the Cochrane Collaboration in the four months since the last 'Cochrane Corner', with the publication of six new or updated reviews summarised here, all conducted with the bulletproof Collaboration's methodology representing the pinnacle of evidence relevant to orthopaedic surgeons.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 19 - 23
1 Jan 2014
Sabharwal S Gauher S Kyriacou S Patel V Holloway I Athanasiou T

We evaluated the quality of guidelines on thromboprophylaxis in orthopaedic surgery by examining how they adhere to validated methodological standards in their development. A structured review was performed for guidelines that were published between January 2005 and April 2013 in medical journals or on the Internet. A pre-defined computerised search was used in MEDLINE, Scopus and Google to identify the guidelines. The AGREE II assessment tool was used to evaluate the quality of the guidelines in the study.

Seven international and national guidelines were identified. The overall methodological quality of the individual guidelines was good. ‘Scope and Purpose’ (median score 98% interquartile range (IQR)) 86% to 98%) and ‘Clarity of Presentation’ (median score 90%, IQR 90% to 95%) were the two domains that received the highest scores. ‘Applicability’ (median score 68%, IQR 45% to 75%) and ‘Editorial Independence’ (median score 71%, IQR 68% to 75%) had the lowest scores.

These findings reveal that although the overall methodological quality of guidelines on thromboprophylaxis in orthopaedic surgery is good, domains within their development, such as ‘Applicability’ and ‘Editorial Independence’, need to be improved. Application of the AGREE II instrument by the authors of guidelines may improve the quality of future guidelines and provide increased focus on aspects of methodology used in their development that are not robust.

Cite this article: Bone Joint J 2014;96-B:19–23.


Bone & Joint 360
Vol. 4, Issue 3 | Pages 33 - 34
1 Jun 2015
Foy MA


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1474 - 1479
1 Nov 2013
Tsang SJ Gaston P

Total hip replacement (THR) has been shown to be a cost-effective procedure. However, it is not risk-free. Certain conditions, such as diabetes mellitus, are thought to increase the risk of complications. In this study we have evaluated the prevalence of diabetes mellitus in patients undergoing THR and the associated risk of adverse operative outcomes. A meta-analysis and systematic review were conducted according to the guidelines of the meta-analysis of observational studies in epidemiology. Inclusion criteria were observational studies reporting the prevalence of diabetes in the study population, accompanied by reports of at least one of the following outcomes: venous thromboembolic events; acute coronary events; infections of the urinary tract, lower respiratory tract or surgical site; or requirement for revision arthroplasty. Altman and Bland’s methods were used to calculate differences in relative risks. The prevalence of diabetes mellitus was found to be 5.0% among patients undergoing THR, and was associated with an increased risk of established surgical site infection (odds ratio (OR) 2.04 (95% confidence interval (CI) 1.52 to 2.76)), urinary infection (OR 1.43 (95% CI 1.33 to 1.55)) and lower respiratory tract infections (OR 1.95 (95% CI 1.61 to 2.26)). Diabetes mellitus is a relatively common comorbidity encountered in THR. Diabetic patients have a higher rate of developing both surgical site and non-surgical site infections following THR.

Cite this article: Bone Joint J 2013;95-B:1474–9.