We have treated 42 consecutive complex ununited fractures of the femoral shaft by wave-plate osteosynthesis at five different medical centres. There were 13 with previous
We have designed a modular cemented femoral component for revision of failed total hip arthroplasty in which deficiency of the proximal femur is such as to require a variable extrafemoral portion of the stem. We present the results of the first 74 operations in 72 patients; 56 of the patients had grade-3 or grade-4 femoral deficiency as defined by Gustilo and Pasternak and 24 had fractures of the proximal femur, of which 22 were periprosthetic. There was or had been
Non-tuberculous mycobacterial infections pose a significant diagnostic and therapeutic challenge. We report two cases of such
Breast cancer is generally managed surgically with adjuvant agents which include hormone therapy, chemotherapy, radiotherapy and bisphosphonate therapy. However, some of these adjuvant therapies may cause adverse events, including wound
The aim of this study was to investigate the clinical and radiographic
outcomes of microendoscopic laminotomy in patients with lumbar stenosis
and concurrent degenerative spondylolisthesis (DS), and to determine
the effect of this procedure on spinal stability. A total of 304 consecutive patients with single-level lumbar
DS with concomitant stenosis underwent microendoscopic laminotomy
without fusion between January 2004 and December 2010. Patients
were divided into two groups, those with and without advanced DS
based on the degree of spondylolisthesis and dynamic instability. A
total of 242 patients met the inclusion criteria. There were 101
men and 141 women. Their mean age was 68.1 years (46 to 85). Outcome
was assessed using the Japanese Orthopaedic Association and Roland
Morris Disability Questionnaire scores, a visual analogue score
for pain and the Short Form Health-36 score. The radiographic outcome
was assessed by measuring the slip and the disc height. The clinical
and radiographic parameters were evaluated at a mean follow-up of
4.6 years (3 to 7.5).Aims
Patients and Methods
The aim of this study was to determine whether the sequential
application of povidone iodine-alcohol (PVI) followed by chlorhexidine
gluconate-alcohol (CHG) would reduce surgical wound contamination
to a greater extent than PVI applied twice in patients undergoing
spinal surgery. A single-centre, interventional, two arm, parallel group randomised
controlled trial was undertaken, involving 407 patients who underwent
elective spinal surgery. For 203 patients, the skin was disinfected before surgery using
PVI (10% [w/w (1% w/w available iodine)] in 95% industrial denatured
alcohol, povidone iodine; Videne Alcoholic Tincture) twice, and
for 204 patients using PVI once followed by CHG (2% [w/v] chlorhexidine
gluconate in 70% [v/v] isopropyl alcohol; Chloraprep with tint).
The primary outcome measure was contamination of the wound determined
by aerobic and anaerobic bacterial growth from samples taken after
disinfection.Aims
Patients and Methods
Total hip arthroplasty was performed in 45 hips of 44 patients who had pyogenic arthritis of the hip during childhood. The average age of the patients was 36.4 years (range 19 to 50). The interval between active
In developing countries locally-made low-cost prostheses are mainly used in limb-salvage surgery to alleviate the economic burden. We retrospectively collected data on 104 patients treated by limb-salvage surgery between July 1997 and July 2005. We used a locally-designed and fabricated stainless-steel endoprosthesis in each case. Oncological and functional outcomes were evaluated at a mean follow-up of 47 months (12 to 118). A total of 73 patients (70.2%) were free from disease, nine (8.7%) were alive with disease, 19 (18.2%) had died from their disease and three (2.9%) from unrelated causes. According to the Musculoskeletal Tumor Society scoring system, the mean functional score was 76.3% (SD 17.8). The five-year survival for the implant was 70.5%. There were nine cases (8.7%) of
We have investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the proximal tibia following resection of a tumour. Survival of the implant and ‘servicing’ procedures have been documented using a prospective database. A total of 194 patients underwent a proximal tibial replacement, with 95 having a fixed-hinge design and 99 a rotating-hinge with a hydroxyapatite collar; their median age was 21.5 years (10 to 74). At a mean follow-up of 14.7 years (5 to 29), 115 patients remain alive. The risk of revision for any reason in the fixed-hinge group was 32% at five years, 61% at ten years and 75% at 15 and 20 years, and in the rotating-hinge group 12% at five years, 25% at ten years and 30% at 15 years. Aseptic loosening was the most common reason for revision in the fixed-hinge knees, fracture of the implant in the early design of rotating hinges and
The success of anterior cruciate ligament reconstruction (ACLR)
depends on osseointegration at the graft-tunnel interface and intra-articular
ligamentization. Our aim was to conduct a systematic review of clinical
and preclinical studies that evaluated biological augmentation of
graft healing in ACLR. In all, 1879 studies were identified across three databases.
Following assessment against strict criteria, 112 studies were included
(20 clinical studies; 92 animal studies). Aims
Materials and Methods
We tested prospectively for hepatitis C virus (HCV) in one orthopaedic surgeon's operative practice for one year. Of 425 consecutive patients, 19 (4.5%) were positive for HCV
A prospective nation-wide study of knee arthroplasty has been under way in Sweden since October 1975. By the end of 1983, 4505 arthroplasties for osteoarthritis and 3495 for rheumatoid arthritis had been recorded and reviewed one, three and six years after the operation. Using actuarial methods, the probability of the prosthesis remaining in situ after six years was calculated. In osteoarthritis this probability ranged from 65% for hinged prostheses to 90% for medial compartment prostheses. Two-and three-compartment prostheses produced intermediate results with 87% survival. In rheumatoid arthritis the probability varied from 72% for medial compartment prostheses to 90% for two- and three-compartment prostheses. The main reason for failure was loosening of the components, the second most common was
Distraction osteogenesis is widely used for leg lengthening, but often requires a long period of external fixation which carries risks of pin-track sepsis, malalignment, stiffness of the joint and late fracture of the regenerate. We present the results of 20 cases in which, in an attempt to reduce the rate of complications, a combination of external fixation and intramedullary nailing was used. The mean gain in length was 4.7 cm (2 to 8.6). The mean time of external fixation was 20 days per centimetre gain in length. All distracted segments healed spontaneously without refracture or malalignment. There were three cases of deep
One hundred and three sequential Stanmore knee replacements were reviewed retrospectively on two occasions with a maximal follow-up period of nine years three months. This knee prosthesis, which is hinged, was successful in alleviating pain, stabilising an unstable knee and modestly increasing the arc of flexion. Walking capacity was increased and flexion contractures were reduced. There were seven cases of
Failure of union of the tibia with a large defect is difficult to treat, especially in the presence of sepsis and adherent scars. Conventional methods of fixation and bone grafting are not easily applicable. Experiments on Macaca monkeys showed that a vascularised pedicle graft of the shaft of the ipsilateral fibula could be fixed across a defect in the tibia and remain viable, even if it was isolated from surrounding soft tissues. Transfer of part of the shaft of the ipsilateral fibula on a vascular and muscle pedicle was carried out in 11 patients with large tibial defects and sepsis. There was one failure because of severe
This study aimed to assess the effect of age and osteoporosis on the proliferative and differentiating capacity of bone-marrow-derived mesenchymal stem cells (MSCs) in female rats. We also discuss the role of these factors on expression and migration of cells along the C-X-C chemokine receptor type 4 (CXCR-4) / stromal derived factor 1 (SDF-1) axis. Mesenchymal stem cells were harvested from the femora of young, adult, and osteopenic Wistar rats. Cluster of differentiation (CD) marker and CXCR-4 expression was measured using flow cytometry. Cellular proliferation was measured using Alamar Blue, osteogenic differentiation was measured using alkaline phosphatase expression and alizarin red production, and adipogenic differentiation was measured using Oil red O. Cells were incubated in Boyden chambers to quantify their migration towards SDF-1. Data was analyzed using a Student’s Objectives
Methods
Patients with flexion instability after total knee arthroplasty
(TKA) often present with a recurrent effusion, which may be a haemarthrosis.
While the radiographic factors contributing to flexion instability
have been elucidated, the clinical diagnosis remains challenging.
Our aim, in this study, was to determine the mean white cell count
and differential profile in pre-operative aspirations of synovial
fluid in a consecutive series of patients undergoing revision TKA
for flexion instability. Between 2000 and 2010, 60 patients undergoing aseptic revision
TKA for flexion instability were identified. The results of the
pre-operative aspiration of synovial fluid were available for 53
patients (88%). These patients were 1:2 matched to 106 patients
who underwent aseptic TKA for indications other than flexion instability.
The mean age of the patients at revision TKA was 65 years (44 to
82) and 55% were women. The mean follow-up was 4.3 years (2 to 10.2).Aims
Patients and Methods
Adolescent idiopathic scoliosis (AIS) is a complex
3D deformity of the spine. Its prevalence is between 2% and 3% in the
general population, with almost 10% of patients requiring some form
of treatment and up to 0.1% undergoing surgery. The cosmetic aspect
of the deformity is the biggest concern to the patient and is often
accompanied by psychosocial distress. In addition, severe curves
can cause cardiopulmonary distress. With proven benefits from surgery,
the aims of treatment are to improve the cosmetic and functional
outcomes. Obtaining correction in the coronal plane is not the only
important endpoint anymore. With better understanding of spinal
biomechanics and the long-term effects of multiplanar imbalance,
we now know that sagittal balance is equally, if not more, important.
Better correction of deformities has also been facilitated by an
improvement in the design of implants and a better understanding
of metallurgy. Understanding the unique character of each deformity
is important. In addition, using the most appropriate implant and
applying all the principles of correction in a bespoke manner is important
to achieve optimum correction. In this article, we review the current concepts in AIS surgery. Cite this article: