Advertisement for orthosearch.org.uk
Results 221 - 240 of 327
Results per page:
Bone & Joint 360
Vol. 4, Issue 2 | Pages 15 - 17
1 Apr 2015

The April 2015 Foot & Ankle Roundup360 looks at: Plantar pressures linked to radiographs; Strength training for ankle instability?; Is weight loss good for your feet?; Diabetes and foot surgery complications; Tantalum for failed ankle arthroplasty?; Steroids, costs and Morton’s neuroma; Ankle arthritis and subtalar joint


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 544 - 549
1 Apr 2015
Qu H Guo W Yang R Tang X Yan T Li D Yang Y Zang J

We determined the efficacy of a devitalised autograft (n = 13) and allograft (n = 16) cortical strut bone graft combined with long-stem endoprosthetic reconstruction in the treatment of massive tumours of the lower limb. A total of 29 patients (18 men:11 women, mean age 20.1 years (12 to 45) with a ratio of length of resection to that of the whole prosthesis of > 50% were treated between May 2003 and May 2012. The mean follow-up was 47 months (15 to 132). The stem of the prosthesis was introduced through bone graft struts filled with cement, then cemented into the residual bone. Bone healing was achieved in 23 patients (86%). The mean Musculoskeletal Tumour Society functional score was 85% (57 to 97). The five-year survival rate of the endoprostheses was 81% (95% confidence intervals 67.3 to 92.3). The mean length of devitalised autografts and allografts was 8.6 cm (5 to 15), which increased the ratio of the the length of the stem of the prosthesis to that of the whole length of the prosthesis from a theoretical 35% to an actual 55%.

Cortical strut bone grafting and long-stem endoprosthetic reconstruction is an option for treating massive segmental defects following resection of a tumour in the lower limb. Patients can regain good function with a low incidence of aseptic loosening. The strut graft and the residual bone together serve as a satisfactory bony environment for a revision prosthesis, if required, once union is achieved.

Cite this article: Bone Joint J 2015;97-B:544–9.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1610 - 1617
1 Dec 2014
Lainiala O Eskelinen A Elo P Puolakka T Korhonen J Moilanen T

We conducted a retrospective study to assess the prevalence of adverse reactions to metal debris (ARMD) in patients operated on at our institution with metal-on-metal (MoM) total hip replacements with 36 mm heads using a Pinnacle acetabular shell. A total of 326 patients (150 males, 175 hips; 176 females, 203 hips) with a mean age of 62.7 years (28 to 85) and mean follow-up of 7.5 years (0.1 to 10.8) participating in our in-depth modern MoM follow-up programme were included in the study, which involved recording whole blood cobalt and chromium ion measurements, Oxford hip scores (OHS) and plain radiographs of the hip and targeted cross-sectional imaging. Elevated blood metal ion levels (> 5 parts per billion) were seen in 32 (16.1%) of the 199 patients who underwent unilateral replacement. At 23 months after the start of our modern MoM follow-up programme, 29 new cases of ARMD had been revealed. Hence, the nine-year survival of this cohort declined from 96% (95% CI 95 to 98) with the old surveillance routine to 86% (95% CI 82 to 90) following the new protocol. Although ARMD may not be as common in 36 mm MoM THRs as in those with larger heads, these results support the Medicines and Healthcare Products Regulatory Agency guidelines on regular reviews and further investigations, and emphasise the need for specific a follow-up programme for patients with MoM THRs.

Cite this article: Bone Joint J 2014; 96-B:1610–17.


Bone & Joint 360
Vol. 3, Issue 3 | Pages 2 - 8
1 Jun 2014
Phillips JRA Waterson HB Searle DJ Mandalia VI Toms AD

This is the second of a series of reviews of registries. This review looks specifically at worldwide registry data that have been collected on knee arthroplasty, what we have learned from their reports, and what the limitations are as to what we currently know.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 215 - 220
1 Feb 2015
Soons J Rakhorst HA Ruettermann M Luijsterburg AJM Bos PK Zöphel OT

A total of seven patients (six men and one woman) with a defect in the Achilles tendon and overlying soft tissue underwent reconstruction using either a composite radial forearm flap (n = 3) or an anterolateral thigh flap (n = 4). The Achilles tendons were reconstructed using chimeric palmaris longus (n = 2) or tensor fascia lata (n = 2) flaps or transfer of the flexor hallucis longus tendon (n = 3). Surgical parameters such as the rate of complications and the time between the initial repair and flap surgery were analysed. Function was measured objectively by recording the circumference of the calf, the isometric strength of the plantar flexors and the range of movement of the ankle. The Achilles tendon Total Rupture Score (ATRS) questionnaire was used as a patient-reported outcome measure. Most patients had undergone several previous operations to the Achilles tendon prior to flap surgery. The mean time to flap surgery was 14.3 months (2.1 to 40.7).

At a mean follow-up of 32.3 months (12.1 to 59.6) the circumference of the calf on the operated lower limb was reduced by a mean of 1.9 cm (sd 0.74) compared with the contralateral limb (p = 0.042). The mean strength of the plantar flexors on the operated lower limb was reduced to 88.9% of that of the contralateral limb (p = 0.043). There was no significant difference in the range of movement between the two sides (p = 0.317). The mean ATRS score was 72 points (sd 20.0). One patient who had an initial successful reconstruction developed a skin defect of the composite flap 12 months after free flap surgery and this resulted in recurrent infections, culminating in transtibial amputation 44 months after reconstruction.

These otherwise indicate that reconstruction of the Achilles tendon combined with flap cover results in a successful and functional reconstruction.

Cite this article: Bone Joint J 2015;97-B:215–20.


Bone & Joint 360
Vol. 3, Issue 4 | Pages 21 - 23
1 Aug 2014

The August 2014 Shoulder & Elbow Roundup360 looks at: Myofibroblasts perhaps not implicated in post-traumatic elbow stiffness; olecranon tip biomechanically sound for coranoid reconstruction; obesity and elbow replacement don’t mix; single column plating successful for extra-articular distal humeral fractures; satisfaction not predictable in frozen shoulder; tenodesis and repair both acceptable in Grade II SLAP tears; glenoid bone grafting is effective and glenohumeral articular lesions best seen with an arthroscope.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 10 - 18
1 Jan 2015
Sabah SA Henckel J Cook E Whittaker R Hothi H Pappas Y Blunn G Skinner JA Hart AJ

Arthroplasty registries are important for the surveillance of joint replacements and the evaluation of outcome. Independent validation of registry data ensures high quality. The ability for orthopaedic implant retrieval centres to validate registry data is not known. We analysed data from the National Joint Registry for England, Wales and Northern Ireland (NJR) for primary metal-on-metal hip arthroplasties performed between 2003 and 2013. Records were linked to the London Implant Retrieval Centre (RC) for validation. A total of 67 045 procedures on the NJR and 782 revised pairs of components from the RC were included. We were able to link 476 procedures (60.9%) recorded with the RC to the NJR successfully. However, 306 procedures (39.1%) could not be linked. The outcome recorded by the NJR (as either revised, unrevised or death) for a primary procedure was incorrect in 79 linked cases (16.6%). The rate of registry-retrieval linkage and correct assignment of outcome code improved over time. The rates of error for component reference numbers on the NJR were as follows: femoral head category number 14/229 (5.0%); femoral head batch number 13/232 (5.3%); acetabular component category number 2/293 (0.7%) and acetabular component batch number 24/347 (6.5%).

Registry-retrieval linkage provided a novel means for the validation of data, particularly for component fields. This study suggests that NJR reports may underestimate rates of revision for many types of metal-on-metal hip replacement. This is topical given the increasing scope for NJR data. We recommend a system for continuous independent evaluation of the quality and validity of NJR data.

Cite this article: Bone Joint J 2015;97-B:10–18.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 807 - 816
1 Jun 2014
Rajaee SS Kanim LEA Bae HW

Using the United States Nationwide Inpatient Sample, we identified national trends in revision spinal fusion along with a comprehensive comparison of comorbidities, inpatient complications and surgical factors of revision spinal fusion compared to primary spinal fusion.

In 2009, there were 410 158 primary spinal fusion discharges and 22 128 revision spinal fusion discharges. Between 2002 and 2009, primary fusion increased at a higher rate compared with revision fusion (56.4% vs 51.0%; p < 0.001). In 2009, the mean length of stay and hospital charges were higher for revision fusion discharges than for primary fusion discharges (4.2 days vs 3.8 days, p < 0.001; USD $91 909 vs. $87 161, p < 0.001). In 2009, recombinant human bone morphogenetic protein (BMP) was used more in revision fusion than in primary fusion (39.6% vs 27.6%, p < 0.001), whereas interbody devices were used less in revision fusion (41.8% vs 56.6%, p < 0.001).

In the multivariable logistic regression model for all spinal fusions, depression (odds ratio (OR) 1.53, p < 0.001), psychotic disorders (OR 1.49, p < 0.001), deficiency anaemias (OR 1.35, p < 0.001) and smoking (OR 1.10, p = 0.006) had a greater chance of occurrence in revision spinal fusion discharges than in primary fusion discharges, adjusting for other variables. In terms of complications, after adjusting for all significant comorbidities, this study found that dural tears (OR 1.41; p < 0.001) and surgical site infections (OR 3.40; p < 0.001) had a greater chance of occurrence in revision spinal fusion discharges than in primary fusion discharges (p < 0.001). A p-value < 0.01 was considered significant in all final analyses.

Cite this article: Bone Joint J 2014;96-B:807–16.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1546 - 1552
1 Nov 2014
Hägglund G Alriksson-Schmidt A Lauge-Pedersen H Rodby-Bousquet E Wagner P Westbom L

In 1994 a cerebral palsy (CP) register and healthcare programme was established in southern Sweden with the primary aim of preventing dislocation of the hip in these children.

The results from the first ten years were published in 2005 and showed a decrease in the incidence of dislocation of the hip, from 8% in a historical control group of 103 children born between 1990 and 1991 to 0.5% in a group of 258 children born between 1992 and 1997. These two cohorts have now been re-evaluated and an additional group of 431 children born between 1998 and 2007 has been added.

By 1 January 2014, nine children in the control group, two in the first study group and none in the second study group had developed a dislocated hip (p < 0.001). The two children in the first study group who developed a dislocated hip were too unwell to undergo preventive surgery. Every child with a dislocated hip reported severe pain, at least periodically, and four underwent salvage surgery. Of the 689 children in the study groups, 91 (13%) underwent preventive surgery.

A population-based hip surveillance programme enables the early identification and preventive treatment, which can result in a significantly lower incidence of dislocation of the hip in children with CP.

Cite this article: Bone Joint J 2014; 96-B:1546–52.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1649 - 1656
1 Dec 2014
Lindberg-Larsen M Jørgensen CC Bæk Hansen T Solgaard S Odgaard A Kehlet H

We present detailed information about early morbidity after aseptic revision knee replacement from a nationwide study. All aseptic revision knee replacements undertaken between 1st October 2009 and 30th September 2011 were analysed using the Danish National Patient Registry with additional information from the Danish Knee Arthroplasty Registry. The 1218 revisions involving 1165 patients were subdivided into total revisions, large partial revisions, partial revisions and revisions of unicondylar replacements (UKR revisions). The mean age was 65.0 years (27 to 94) and the median length of hospital stay was four days (interquartile range: 3 to 5), with a 90 days re-admission rate of 9.9%, re-operation rate of 3.5% and mortality rate of 0.2%. The age ranges of 51 to 55 years (p = 0.018), 76 to 80 years (p < 0.001) and ≥ 81 years (p < 0.001) were related to an increased risk of re-admission. The age ranges of 76 to 80 years (p = 0.018) and the large partial revision subgroup (p = 0.073) were related to an increased risk of re-operation. The ages from 76 to 80 years (p < 0.001), age ≥ 81 years (p < 0.001) and surgical time > 120 min (p <  0.001) were related to increased length of hospital stay, whereas the use of a tourniquet (p = 0.008) and surgery in a low volume centre (p = 0.013) were related to shorter length of stay.

In conclusion, we found a similar incidence of early post-operative morbidity after aseptic knee revisions as has been reported after primary procedures. This suggests that a length of hospital stay ≤ four days and discharge home at that time is safe following aseptic knee revision surgery in Denmark.

Cite this article: Bone Joint J 2014;96-B:1649–56.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 22 - 24
1 Feb 2015

The February 2015 Shoulder & Elbow Roundup360 looks at: Proximal Humerus fractures a comprehensive review, Predicting complications in shoulder ORIF, The Coronoid Revisited, Remplissage and bankart repair for Hill-Sach’s lesions, Diabetes and elbow arthroplasty, Salvage surgery for failed bankart repair, Sternoclavicular Joint Reconstruction, Steroids effective in the short-term for tennis elbow


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1404 - 1410
1 Oct 2014
Wafa H Grimer RJ Jeys L Abudu AT Carter SR Tillman RM

The aim of this study was to evaluate the functional and oncological outcome of extracorporeally irradiated autografts used to reconstruct the pelvis after a P1/2 internal hemipelvectomy.

The study included 18 patients with a primary malignant bone tumour of the pelvis. There were 13 males and five females with a mean age of 24.8 years (8 to 62). Of these, seven had an osteogenic sarcoma, six a Ewing’s sarcoma, and five a chondrosarcoma. At a mean follow-up of 51.6 months (4 to 185), nine patients had died with metastatic disease while nine were free from disease. Local recurrence occurred in three patients all of whom eventually died of their disease. Deep infection occurred in three patients and required removal of their graft in two while the third underwent a hindquarter amputation for extensive flap necrosis.

The mean Musculoskeletal Tumor Society functional score of the 16 patients who could be followed-up for at least 12 months was 77% (50 to 90). Those 15 patients who completed the Toronto Extremity Salvage Score questionnaire had a mean score of 71% (53 to 85).

Extracorporeal irradiation and re-implantation of bone is a valid method of reconstruction after an internal hemipelvectomy. It has an acceptable morbidity and a functional outcome that compares favourably with other available reconstructive techniques.

Cite this article: Bone Joint J 2014;96-B:1404–10


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1464 - 1471
1 Nov 2014
Lindberg-Larsen M Jørgensen CC Hansen TB Solgaard S Kehlet H

Data on early morbidity and complications after revision total hip replacement (THR) are limited. The aim of this nationwide study was to describe and quantify early morbidity after aseptic revision THR and relate the morbidity to the extent of the revision surgical procedure. We analysed all aseptic revision THRs from 1st October 2009 to 30th September 2011 using the Danish National Patient Registry, with additional information from the Danish Hip Arthroplasty Registry. There were 1553 procedures (1490 patients) performed in 40 centres and we divided them into total revisions, acetabular component revisions, femoral stem revisions and partial revisions. The mean age of the patients was 70.4 years (25 to 98) and the median hospital stay was five days (interquartile range 3 to 7). Within 90 days of surgery, the readmission rate was 18.3%, mortality rate 1.4%, re-operation rate 6.1%, dislocation rate 7.0% and infection rate 3.0%. There were no differences in these outcomes between high- and low-volume centres. Of all readmissions, 255 (63.9%) were due to ‘surgical’ complications versus 144 (36.1%) ‘medical’ complications. Importantly, we found no differences in early morbidity across the surgical subgroups, despite major differences in the extent and complexity of operations. However, dislocations and the resulting morbidity represent the major challenge for improvement in aseptic revision THR.

Cite this article: Bone Joint J 2014; 96-B:1464–71.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1411 - 1418
1 Oct 2014
Hultgren T Jönsson K Roos F Järnbert-Pettersson H Hammarberg H

We present the long-term results of open surgery for internal shoulder rotational deformity in brachial plexus birth palsy (BPBP).

From 1997 to 2005, 207 patients (107 females, 100 males, mean age 6.2 (0.6 to 34)) were operated on with subscapularis elongation and/or latissimus dorsi to infraspinatus transfer. Incongruent shoulder joints were relocated. The early results of these patients has been reported previously. We analysed 118 (64 females, 54 males, mean age 15.1 (7.6 to 34)) of the original patient cohort at a mean of 10.4 years (7.0 to 15.1) post-operatively. A third of patients with relocated joints had undergone secondary internal rotational osteotomy of the humerus.

A mixed effects models approach was used to evaluate the effects of surgery on shoulder rotation, abduction, and the Mallet score. Independent factors were time (pre-and post-surgery), gender, age, joint category (congruent, relocated, relocated plus osteotomy) and whether or not a transfer had been performed. Data from a previously published short-term evaluation were reworked in order to obtain pre-operative values.

The mean improvement in external rotation from pre-surgery to the long-term follow-up was 66.5° (95% confidence interval (CI) 61.5 to 71.6). The internal rotation had decreased by a mean of 22.6° (95% CI -18.7 to -26.5). The mean improvement in the three-grade aggregate Mallet score was 3.1 (95% CI 2.7 to 3.4), from 8.7 (95% CI 8.4 to 9.0) to 11.8 (11.5 to 12.1).

Our results show that open subscapularis elongation achieves good long-term results for patients with BPBP and an internal rotation contracture, providing lasting joint congruency and resolution of the trumpet sign, but with a moderate mean loss of internal rotation.

Cite this article: Bone Joint J 2014;96-B:1411–18


Bone & Joint 360
Vol. 2, Issue 5 | Pages 8 - 12
1 Oct 2013
Phillips JRA

Not all questions can be answered by prospective randomised controlled trials. Registries were introduced as a way of collecting information on joint replacements at a population level. They have helped to identify failing implants and the data have also been used to monitor the performance of individual surgeons. This review aims to look at some of the less well known registries that are currently being used worldwide, including those kept on knee ligaments, ankle arthroplasty, fractures and trauma.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 876 - 883
1 Jul 2014
Grammatopoulos G Pandit HG da Assunção R Taylor A McLardy-Smith P De Smet KA Murray DW Gill HS

The orientation of the acetabular component is influenced not only by the orientation at which the surgeon implants the component, but also the orientation of the pelvis at the time of implantation. Hence, the orientation of the pelvis at set-up and its movement during the operation, are important. During 67 hip replacements, using a validated photogrammetric technique, we measured how three surgeons orientated the patient’s pelvis, how much the pelvis moved during surgery, and what effect these had on the final orientation of the acetabular component. Pelvic orientation at set-up, varied widely (mean (± 2, standard deviation (sd))): tilt 8° (2sd ±32), obliquity –4° (2sd ±12), rotation –8° (2sd ±14). Significant differences in pelvic positioning were detected between surgeons (p < 0.001). The mean angular movement of the pelvis between set-up and component implantation was 9° (sd 6). Factors influencing pelvic movement included surgeon, approach (posterior >  lateral), procedure (hip resurfacing > total hip replacement) and type of support (p < 0.001). Although, on average, surgeons achieved their desired acetabular component orientation, there was considerable variability (2sd ±16) in component orientation. We conclude that inconsistency in positioning the patient at set-up and movement of the pelvis during the operation account for much of the variation in acetabular component orientation. Improved methods of positioning and holding the pelvis are required.

Cite this article: Bone Joint J 2014; 96-B:876–83.


Bone & Joint Research
Vol. 3, Issue 1 | Pages 14 - 19
1 Jan 2014
James SJ Mirza SB Culliford DJ Taylor PA Carr AJ Arden NK

Aims

Osteoporosis and abnormal bone metabolism may prove to be significant factors influencing the outcome of arthroplasty surgery, predisposing to complications of aseptic loosening and peri-prosthetic fracture. We aimed to investigate baseline bone mineral density (BMD) and bone turnover in patients about to undergo arthroplasty of the hip and knee.

Methods

We prospectively measured bone mineral density of the hip and lumbar spine using dual-energy X-ray absorptiometry (DEXA) scans in a cohort of 194 patients awaiting hip or knee arthroplasty. We also assessed bone turnover using urinary deoxypyridinoline (DPD), a type I collagen crosslink, normalised to creatinine.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 641 - 645
1 May 2014
Tsutsumimoto T Yui M Uehara M Ohta H Kosaku H Misawa H

Little information is available about the incidence and outcome of incidental dural tears associated with microendoscopic lumbar decompressive surgery. We prospectively examined the incidence of dural tears and their influence on the outcome six months post-operatively in 555 consecutive patients (mean age 47.4 years (13 to 89)) who underwent this form of surgery. The incidence of dural tears was 5.05% (28/555). The risk factors were the age of the patient and the procedure of bilateral decompression via a unilateral approach. The rate of recovery of the Japanese Orthopaedic Association score in patients with dural tears was significantly lower than that in those without a tear (77.7% vs 87.6%; p < 0.02), although there were no significant differences in the improvement of the Oswestry Disability Index between the two groups. Most dural tears were small, managed by taking adequate care of symptoms of low cerebrospinal fluid pressure, and did not require direct dural repair. Routine MRI scans were undertaken six months post-operatively; four patients with a dural tear had recurrent or residual disc herniation and two had further stenosis, possibly because the dural tear prevented adequate decompression and removal of the fragments of disc during surgery; as yet, none of these patients have undergone further surgery.

Cite this article: Bone Joint J 2014;96-B:641–5.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 345 - 349
1 Mar 2014
Liddle AD Pandit HG Jenkins C Lobenhoffer P Jackson WFM Dodd CAF Murray DW

The cementless Oxford unicompartmental knee replacement has been demonstrated to have superior fixation on radiographs and a similar early complication rate compared with the cemented version. However, a small number of cases have come to our attention where, after an apparently successful procedure, the tibial component subsides into a valgus position with an increased posterior slope, before becoming well-fixed. We present the clinical and radiological findings of these six patients and describe their natural history and the likely causes. Two underwent revision in the early post-operative period, and in four the implant stabilised and became well-fixed radiologically with a good functional outcome.

This situation appears to be avoidable by minor modifications to the operative technique, and it appears that it can be treated conservatively in most patients.

Cite this article: Bone Joint J 2014;96-B:345–9.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1204 - 1208
1 Sep 2013
Kerens B Boonen B Schotanus MGM Lacroix H Emans PJ Kort NP

Although it has been suggested that the outcome after revision of a unicondylar knee replacement (UKR) to total knee replacement (TKR) is better when the mechanism of failure is understood, a comparative study on this subject has not been undertaken.

A total of 30 patients (30 knees) who underwent revision of their unsatisfactory UKR to TKR were included in the study: 15 patients with unexplained pain comprised group A and 15 patients with a defined cause for pain formed group B. The Oxford knee score (OKS), visual analogue scale for pain (VAS) and patient satisfaction were assessed before revision and at one year after revision, and compared between the groups.

The mean OKS improved from 19 (10 to 30) to 25 (11 to 41) in group A and from 23 (11 to 45) to 38 (20 to 48) in group B. The mean VAS improved from 7.7 (5 to 10) to 5.4 (1 to 8) in group A and from 7.4 (2 to 9) to 1.7 (0 to 8) in group B. There was a statistically significant difference between the mean improvements in each group for both OKS (p = 0.022) and VAS (p = 0.002). Subgroup analysis in group A, performed in order to define a patient factor that predicts outcome of revision surgery in patients with unexplained pain, showed no pre-operative differences between both subgroups.

These results may be used to inform patients about what to expect from revision surgery, highlighting that revision of UKR to TKR for unexplained pain generally results in a less favourable outcome than revision for a known cause of pain.

Cite this article: Bone Joint J 2013;95-B:1204–8.