This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant. A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life.Aims
Methods
In this retrospective study, using the prospectively collected database of the AO-Documentation Centre, we analysed the outcome of 57 malunited fractures of the ankle treated by reconstructive osteotomy. In all cases the position of the malunited fibula had been corrected, in several cases it was combined with other osteotomies and the fixation of any non-united fragments. Patients were seen on a regular basis, with a minimum follow-up of ten years. The aim of the study was to establish whether reconstruction improves ankle function and prevents the progression of arthritic changes. Good or excellent results were obtained in 85% (41) of patients indicating that reconstructive surgery is effective in most and that the beneficial effects can last for up to 27 years after the procedure. Minor
Intraoperative pressure sensors allow surgeons to quantify soft-tissue balance during total knee arthroplasty (TKA). The aim of this study was to determine whether using sensors to achieve soft-tissue balance was more effective than manual balancing in improving outcomes in TKA. A multicentre randomized trial compared the outcomes of sensor balancing (SB) with manual balancing (MB) in 250 patients (285 TKAs). The primary outcome measure was the mean difference in the four Knee injury and Osteoarthritis Outcome Score subscales (ΔKOOS4) in the two groups, comparing the preoperative and two-year scores. Secondary outcomes included intraoperative balance data, additional patient-reported outcome measures (PROMs), and functional measures.Aims
Methods
The aim of the HIPGEN consortium is to develop the first cell therapy product for hip fracture patients using PLacental-eXpanded (PLX-PAD) stromal cells. HIPGEN is a multicentre, multinational, randomized, double-blind, placebo-controlled trial. A total of 240 patients aged 60 to 90 years with low-energy femoral neck fractures (FNF) will be allocated to two arms and receive an intramuscular injection of either 150 × 106 PLX-PAD cells or placebo into the medial gluteal muscle after direct lateral implantation of total or hemi hip arthroplasty. Patients will be followed for two years. The primary endpoint is the Short Physical Performance Battery (SPPB) at week 26. Secondary and exploratory endpoints include morphological parameters (lean body mass), functional parameters (abduction and handgrip strength, symmetry in gait, weightbearing), all-cause mortality rate and patient-reported outcome measures (Lower Limb Measure, EuroQol five-dimension questionnaire). Immunological biomarker and in vitro studies will be performed to analyze the PLX-PAD mechanism of action. A sample size of 240 subjects was calculated providing 88% power for the detection of a 1 SPPB point treatment effect for a two-sided test with an α level of 5%.Aims
Methods
Free vascularised fibular grafting has been reported
to be successful for adult patients with osteonecrosis of the femoral
head (ONFH). However, its benefit in teenage patients with post-traumatic
ONFH has not been determined. We evaluated the effectiveness of
free vascularised fibular grafting in the treatment of this condition
in children and adolescents. We retrospectively analysed 28 hips
in 28 patients in whom an osteonecrotic femoral head had been treated
with free vascularised fibular grafting between 2002 and 2008. Their
mean age was 16.3 years (13 to 19). The stage of the disease at
time of surgery, and results of treatment including pre- and post-operative
Harris hip scores, were studied. We defined clinical failure as
conversion to total hip replacement. All patients were followed
up for a mean of four years (2 to 7). The mean Harris hip score
improved from 60.4 (37 to 84) pre-operatively to 94.2 (87 to 100)
at final follow-up. At the latest follow-up we found improved or
unchanged radiographs in all four initially stage II hips and in
23 of 24 stage III or IV hips. Only one hip (stage V) deteriorated.
No patient underwent total hip replacement. Free vascularised fibular grafting is indicated for the treatment
of
The October 2012 Wrist &
Hand Roundup. 360. looks at: osteoarticular flaps to the PIPJ; prognosis after wrist arthroscopy; adipofascial flaps and
We have reviewed 32 patients who sustained a substantial knee ligament injury during adolescence when their knee epiphyses were open. They were all treated non-operatively and re-examined and evaluated in detail after an average of eight years. There were 25 Grade II partial tears and seven Grade III complete tears. After Grade II injuries the functional results were excellent or good, though static instability had not improved from the initial
This systematic review and meta-analysis was conducted to compare open reduction and internal fixation (ORIF) with primary arthrodesis (PA) in the treatment of Lisfranc injuries, regarding patient-reported outcome measures (PROMs), and risk of secondary surgery. The aim was to conclusively determine the best available treatment based on the most complete and recent evidence available. A systematic search was conducted in PubMed, Cochrane Controlled Register of Trials (CENTRAL), EMBASE, CINAHL, PEDro, and SPORTDiscus. Additionally, ongoing trial registers and reference lists of included articles were screened. Risk of bias (RoB) and level of evidence were assessed using the Cochrane risk of bias tools and the Grading of Recommendations Assessment, Development and Evaluation (GRADE) tool. The random and fixed-effect models were used for the statistical analysis.Aims
Methods
The results of proximal humeral replacement following trauma are substantially worse than for osteoarthritis or rheumatoid arthritis. The stable reattachment of the lesser and greater tuberosity fragments to the rotator cuff and the restoration of shoulder biomechanics are difficult. In 1992 we developed a prosthesis designed to improve fixation of the tuberosity fragments in comminuted fractures of the proximal humerus. The implant enables fixation of the fragments to the shaft of the prosthesis and the diaphyseal fragment using screws, washers and a special toothed plate. Between 1992 and 2003 we used this technique in 50 of 76 patients referred to our institution for shoulder reconstruction after trauma. In the remaining 26, reconstruction with a prosthesis and nonabsorbable sutures was performed, as the tuberosity fragments were too small and too severely damaged to allow the use of screws and the toothed plate. The Constant score two years post-operatively was a mean of 12 points better in the acute trauma group and 11 points better in the late
This review considers the surgical treatment
of displaced fractures involving the knee in elderly, osteoporotic patients.
The goals of treatment include pain control, early mobilisation,
avoidance of complications and minimising the need for further surgery.
Open reduction and internal fixation (ORIF) frequently results in
loss of reduction, which can result in
The use and variety of stemless humeral components in anatomical total shoulder arthroplasty (TSA) have proliferated since their advent in 2004. Early outcomes are reassuring but independent mid-term results are scarce. This independent study reports a consecutive series of 143 Eclipse stemless shoulder prostheses with a minimum five-year (5 to 10) follow-up. Outcomes of 143 procedures undertaken for all indications in 131 patients were reviewed, with subset analysis of those for osteoarthritis (OA) (n = 99). The primary outcome was the Oxford Shoulder Score (OSS) at a minimum of five years. Secondary outcomes were ranges of motion and radiological analysis of humeral radiolucency, rotator cuff failure, and glenoid loosening.Aims
Methods
Prompt surgical decompression is the only means of preventing the late sequelae of ischaemic contracture in
Between 1992 and 2000, 57 patients with 57 isolated fractures of the medial malleolus were treated conservatively by immobilisation in a cast. The results were assessed by examination, radiography and completion of the short form-36 questionnaire and American Orthopaedic Foot and Ankle Society ankle-hindfoot score. Of the 57 fractures 55 healed without further treatment. The mean combined dorsi- and plantar flexion was 52.3° (25° to 82°) and the mean short form-36 and American Orthopaedic Foot and Ankle Society scores 48.1 (28 to 60) and 89.8 (69 to 100), respectively. At review there was no evidence of medial instability, dermatological complications, malalignment of the mortise or of
Objective . A clinical investigation into a new bone void filler is giving
first data on systemic and local exposure to the anti-infective
substance after implantation. Method . A total of 20 patients with
Linburg-Comstock syndrome is characterised by an anomalous tendon slip from the flexor pollicis longus to the flexor digitorum profundus, usually of the index finger. An incidence as high as 60% to 70% has been reported.
Short uncemented humeral stems can preserve humeral
bone stock and facilitate revision surgery but may be prone to malalignment
or loosening, especially when used in reverse total shoulder replacement
(TSR). We undertook a retrospective review of 44 patients with a
mean age of 76 years (59 to 92) who underwent primary reverse TSR
with a short uncemented humeral stem. There were 29 females. The
indications for joint replacement included cuff tear associated
arthropathy (33), avascular necrosis (six),