We report the 12 to 74 month results of our mark I saddle prosthesis after its use as a salvage device for gross loss of pelvic bone stock in 76 patients with failed hip arthroplasties. The implant transmits load between iliac bone and bare polish chrome-cobalt. Our clinical and radiological results indicate that a useful and stable articulation can be achieved in most cases, provided that continued deep infection can be avoided. The appearance of radiological sclerosis at the bearing site in successful cases seems to indicate that significant late migration will not occur. Based on our experience with the mark I prosthesis we have designed and developed a mark II model which has freedom of axial rotation of the saddle. Our
We reviewed 134 primary noncemented porous-coated total hip replacements in 125 patients: 64 were DePuy AML prostheses, 20 were Howmedica PCA and 50 were Implant Technology LSF. The prostheses had been in situ for an average of 36 months, 40 months and 24 months respectively. The average pre-operative Harris hip scores were 38.2 for AML, 33.2 for PCA, and 41.0 for the LSF prostheses. The average postoperative scores were 80.7 for AML, 83.8 for the PCA, and 91.5 for LSF. Thigh or groin pain associated with the prosthesis was present in 30% of AML, 30% PCA and 8% of the LSF cases. The clinical and radiographic review showed better
We report a randomised prospective trial of the
1. A series of 142 fractures of the trochanteric region treated by fixation with Vitallium nail-plates of the original McLaughlin pattern is described. The hospital mortality was 9 per cent. Disruption of the nail-plate junction occurred in 8 per cent of cases. This confirms McLaughlin and Garcia's (1955) view that this pattern of nail-plate should no longer be used. 2. Despite this, satisfactory functional results were achieved in 78 per cent of the survivors. 3. The new Model V McLaughlin nail-plate is described, and the stresses in nail-plates are considered. On theoretical grounds and laboratory tests the weakness at the nail-plate junction has been eliminated in the new model, and the strength of the appliance as a whole compares favourably with other types of nail-plate. Full clinical trial is therefore justified, and seventy-one patients have so far been operated on, with satisfactory
The Norwegian Arthroplasty Register recorded 24,408 primary total hip replacements from 1987 to 1993; 2907 of them (13%) were performed with uncemented femoral components. We have compared the results of eight different designs, each used in more than 100 patients. Survivorship of the components was estimated by the Kaplan-Meier method using revision for aseptic loosening of the femoral component as the end-point. At 4.5 years, the estimated probability of revision for aseptic loosening for all implants was 4.5%, for the Bio-Fit stem 18.6% (n = 210) and for the Femora stem 13.6% (n = 173). The PM-Prosthesis and the Harris/Galante stem prostheses needed revision in 5.6% and 3.6%, respectively. The clockwise threaded stem of the Femora implant needed revision in 20% of right hips, but in only 4% of left hips. The short-term results of the four best uncemented femoral components (Corail, LMT, Profile and Zweimuller) were similar to those for cemented stems, with revision for loosening in less than 1% at 4.5 years. The importance of the control of innovative designs and the registration of
The crucial role of the radial head in the stability of the elbow in terrible triad injury is acknowledged. This retrospective study aims to compare the results of resection of a severely comminuted radial head with or without prosthetic arthroplasty as part of the reconstruction for this injury. The outcome of radial head resection was compared with prosthetic arthroplasty in 29 and 15 patients with terrible triad injuries, respectively. There were ten female patients (34.5%) in the resection group and six female patients (40%) in the prosthesis group. The mean age was 40.7 years (Aims
Patients and Methods
Aims
Patients and Methods
Aims
Patients and Methods
Severe open fractures of the tibia have a high incidence of complications and a poor outcome. The most usual method of stabilisation is by external fixation, but the advent of small diameter locking intramedullary nails has introduced a new option. We report the
The final results up to 15 years are reported of clinical trials of the management of tuberculosis of the spine in Korea and Hong Kong. In Korea, 350 patients with active spinal tuberculosis were randomised to ambulatory chemotherapy or bed rest in hospital (in Masan) or a plaster-of-Paris jacket for nine months (in Pusan). Patients in both centres were also randomised to either PAS plus isoniazid for 18 months or to the same drugs plus streptomycin for the first three months. In Hong Kong, all 150 patients were treated with the three-drug regime and randomised to either radical excision of the spinal lesion with bone graft or open debridement. On average, the disease was more extensive in Korea, but at 15 years (or 13 or 14 years in a proportion of the patients in Korea) the great majority of patients in both countries achieved a favourable status, no evidence of CNS involvement, no radiological evidence of disease, no sinus or clinically evident abscess, and no restriction of normal physical activity. Most patients had already achieved a favourable status much earlier. The
This study presents the long-term survivorship, risk factors for prosthesis survival, and an assessment of the long-term effects of changes in surgical technique in a large series of patients treated by metal-on-metal (MoM) hip resurfacing arthroplasty (HRA). Between November 1996 and January 2012, 1074 patients (1321 hips) underwent HRA using the Conserve Plus Hip Resurfacing System. There were 787 men (73%) and 287 women (27%) with a mean age of 51 years (14 to 83). The underlying pathology was osteoarthritis (OA) in 1003 (75.9%), developmental dysplasia of the hip (DDH) in 136 (10.3%), avascular necrosis in 98 (7.4%), and other conditions, including inflammatory arthritis, in 84 (6.4%).Aims
Patients and Methods
We describe the development and early clinical application of a ported, proximally-cemented titanium stem for cemented total hip arthroplasty. PMMA bone cement is delivered to the proximal femur under pressure after the stem has been positioned within the femoral canal. A mid-stem cement occluder contains the cement to the proximal stem only. A tapered body is incorporated in the design of the stem to reduce the structural stiffness and hence the degree of stress shielding within the reconstructed joint. We performed preclinical studies to measure the reduction in porosity and the pressurisation achieved. The porosity, as measured by the void percentage within the cured cement mantle, was reduced by more than 50% and there was an almost threefold increase in the mean pressure. Mechanical testing of the stem, using a three-point bend test, showed that the addition of cement injection ports on the anterior and posterior sides of the body of the proximal stem did not reduce its strength. Finite-element analysis indicated that, compared with a fully-cemented conventional stem, there was no change in the stresses within the cement mantle. In a series of 40 proximally-cemented stems followed for up to six years (mean 51 months) the mean Harris hip score was 91, and 85% of patients had good or excellent results. There was excellent pain relief, an increased level of activity and good patient satisfaction. One mechanical failure of the stem required revision at three years after implantation. The
The aim of this review is to address controversies
in the management of dislocations of the acromioclavicular joint. Current
evidence suggests that operative rather than non-operative treatment
of Rockwood grade III dislocations results in better cosmetic and
radiological results, similar functional outcomes and longer time
off work.
The Walch Type C dysplastic glenoid is characterized by excessive
retroversion. This anatomical study describes its morphology. A total of 29 shoulders with a dysplastic glenoid were analyzed.
CT was used to measure retroversion, inclination, height, width,
radius-of-curvature, surface area, depth, subluxation of the humeral
head and the Goutallier classification of fatty infiltration. The
severity of dysplasia and deficiency of the posterior rim of the
glenoid were recorded.Aims
Patients and Methods
The purpose of this study was to compare two different types
of metal-on-metal (MoM) bearing for total hip arthroplasty (THA):
one with a large femoral head (38 mm to 52 mm) and the other with
a conventional femoral head (28 mm or 32 mm). We compared clinical
outcome, blood metal ion levels, and the incidence of pseudotumour in
the two groups. Between December 2009 and December 2011, 62 patients underwent
MoM THA with a large femoral head (Magnum group) and 57 patients
an MoM THA with a conventional femoral head (conventional group).
Clinical outcome was assessed using the Harris Hip score, University
of California, Los Angeles (UCLA) activity score and EuroQol-5D
(EQ-5D). Blood metal ion levels were measured and MRI scans were
analyzed at a minimum of five years postoperatively.Aims
Patients and Methods
Intra-articular 90Yttrium (90Y) is an adjunct
to surgical treatment by synovectomy for patients with diffuse-type tenosynovial
giant-cell tumour (dtTGCT) of the knee, with variable success rates.
Clinical information is, however, sparse and its value remains unclear.
We investigated the long-term outcome of patients who underwent synovectomy
with and without adjuvant treatment with 90Yttrium. All patients with dtTGCT of the knee who underwent synovectomy
between 1991 and 2014 were included in the study. Group A patients
underwent synovectomy and an intra-articular injection of 90Yttrium
between six and eight weeks after surgery. Group B patients underwent
surgery alone.Aims
Patients and Methods
This systematic review examines the current literature regarding surgical techniques for restoring articular cartilage in the hip, from the older microfracture techniques involving perforation to the subchondral bone, to adaptations of this technique using nanofractures and scaffolds. This review discusses the autologous and allograft transfer systems and the autologous matrix-induced chondrogenesis (AMIC) technique, as well as a summary of the previously discussed techniques, which could become common practice for restoring articular cartilage, thus reducing the need for total hip arthroplasty. Using the
The aim of this study was to report the long-term outcome and
implant survival of the lateral resurfacing elbow (LRE) arthroplasty
in the treatment of elbow arthritis. We reviewed a consecutive series of 27 patients (30 elbows) who
underwent LRE arthroplasty between December 2005 and January 2008.
There were 15 women and 12 men, with a mean age of 61 years (25
to 82). The diagnosis was primary hypotrophic osteoarthritis (OA)
in 12 patients (14 elbows), post-traumatic osteoarthritis (PTOA)
in five (five elbows) and rheumatoid arthritis (RA) in ten patients
(11 elbows). The mean clinical outcome scores including the Mayo
Elbow Performance Score (MEPS), the American Shoulder and Elbow
Surgeons elbow score (ASES-e), the mean range of movement and the
radiological outcome were recorded at three, six and 12 months and
at a mean final follow-up of 8.3 years (7.3 to 9.4). A one sample Aim
Patients and Methods