Nerve injury is a rare complication of total hip replacement which may be related to the exposure used for the operation. The posterior approach is traditionally associated with injury to the sciatic nerve. We have compared the incidence of nerve injury after primary total hip replacement (THR) using either a posterior or a direct lateral approach. We studied 42 consecutive patients undergoing primary total hip replacement. The surgeons used a posterior (22 patients) or direct lateral (20 patients) approach in accordance with their normal practice. The obturator, femoral, posterior tibial and common peroneal nerves were assessed clinically and electrophysiologically by electromyography (EMG) and measurement of the velocity of nerve conduction before operation and at four weeks after. All patients were free from symptoms of nerve injury after operation but five lesions were identified in four patients by the electrophysiological studies; the obturator nerve was involved in two, the femoral in one, the common peroneal in one and the posterior tibial in one. All these injuries occurred using the lateral approach. Clinical assessment alone underestimates the incidence of nerve injury complicating THR. Our study does not confirm the association of nerve injury with the posterior approach which had been described previously.
The production of particulate wear debris is a recognised complication of joint arthroplasty, but interest has concentrated on local tissue reactions and a possible association with implant loosening. The fate of wear products in the body remains unknown, although some of the metals used in the construction of orthopaedic implants are known to have toxic and oncogenic properties. We report histological and electron-microscopic evidence from two cases which shows that metallic debris can be identified in the lymphoreticular tissues of the body distant from the hip some years after joint replacement. The increase in the use of total arthroplasty in younger patients, the development of new alloys and the use of porous coatings must raise concern for the long-term effects of the accumulation of wear debris in the body.
In 78 consecutive patients, we performed fine-needle aspiration of the hip before revision surgery. At the revision operation biopsies were taken from the capsule and joint tissues. The aspirate and the homogenised soft-tissue specimens were cultured using a radiometric technique. Fifteen hips proved to be infected and 63 sterile on culture of the tissues taken during revision surgery; 94% of the aspiration results were correct. The sensitivity of the technique was 87% and the specificity 95%. Fine-needle aspiration combined with a radiometric culture technique is a simple and reliable method of diagnosing infection of hip prostheses.
One hundred hips in patients who had had primary uncemented replacements were followed up for one or two years, and assessed by five different methods. All produced different results. The Hospital for Special Surgery rating produced the most optimistic assessment and the Merle d'Aubigne rating the most pessimistic. The functional class of the patients, as defined by Charnley in 1979, significantly affected the ratings, and these should clearly be included in all rating systems. Moreover, if systems are to be compared, they should all use descriptive words, such as limp or pain, in precisely the same way.
A leading problem with cementless hip replacement is thigh pain, probably due to some degree of loosening. This is most pronounced during activities such as stair climbing or getting up from a chair. Our study compares the immediate fixation of three stems in widespread clinical use, using a cadaver test simulation in which the femur was horizontal, and cyclic forces acted vertically downward on the prosthetic head with gradual increments of load. We implanted and tested 18 pairs of femurs, making analyses between stem types by right to left comparisons. We found no statistically significant differences in loosening between cementless AML and PCA prostheses, but cemented stems withstood greater loads than uncemented stems by a factor of five or more.
Ten uncemented total hip replacements were performed in 1975 using an implant in which the cobalt-chrome femoral stem was coated to give a porous surface. In all but one case a high-density polyethylene head was used. The radiological changes in the upper femoral shafts were assessed between three and nine years later. Seven showed extensive stress-relieving changes, loss of calcar, stress fractures at the root of the lesser trochanter with subsequent detachment, and osteoporosis followed by avulsion of the greater trochanter. In these seven patients the lower part of the stem appeared to be soundly embedded, although in only one was there evidence of bony incorporation. It is suggested that if the fixation of a fully coated implant of this sort remains sound, gross atrophy of the upper femoral shaft develops after five years. This atrophy, associated with an implant which can be removed only at the expense of further bone destruction, presents substantial problems if revision is needed.
The April 2024 Hip & Pelvis Roundup. 360. looks at: Impaction bone grafting for femoral revision
We investigated the implant-bone interface around one design of femoral stem, proximally coated with either a plasma-sprayed porous coating (plain porous) or a hydroxyapatite porous coating (porous HA), or which had been grit-blasted (Interlok). Of 165 patients implanted with a Bimetric hip hemiarthroplasty (Biomet, Bridgend, UK) specimens were retrieved from 58 at post-mortem. We estimated ingrowth and attachment of bone to the surface of the implant in 21 of these, eight plain porous, seven porous HA and six Interlok, using image analysis and light morphometric techniques. The amount of HA coating was also quantified. There was significantly more ingrowth (p = 0.012) and attachment of bone (p >
0.05) to the porous HA surface (mean bone ingrowth 29.093 ± 2.019%; mean bone attachment 37.287 ± 2.489%) than to the plain porous surface (mean bone ingrowth 21.762 ± 2.068%; mean bone attachment 18.9411 ± 1.971%). There was no significant difference in attachment between the plain porous and Interlok surfaces. Bone grew more evenly over the surface of the HA coating whereas on the porous surface, bone ingrowth and attachment occurred more on the distal and medial parts of the coated surface. No significant differences in the volume of HA were found with the passage of time. This study shows that HA coating increases the amount of ingrowth and attachment of bone and leads to a more even distribution of bone over the surface of the implant. This may have implications in reducing stress shielding and limiting osteolysis induced by wear particles.
Torsional instability of femoral components has not received much attention, and is difficult to detect in conventional radiographs. To test this we designed a system to apply a load in an anteroposterior direction to the head of a femoral component, implanted into a cadaveric femur. Rotation within the bone was measured, using a purpose built transducer, with and without preservation of the neck, with and without cement, and with longitudinal ridges but no cement. The results show that torsional instability may be a problem in uncemented replacement. Preservation of the femoral neck and the use of a ridged prosthesis increases resistance to rotation. Rotational movements occurring in vivo during such activities as climbing stairs and rising from the seated position may contribute to mechanical loosening.
Retrospective review of 730 consecutive primary uncemented and cemented total hip arthroplasties revealed 19 intra-operative hoop-stress fractures of the femoral neck. These were incomplete, linear, and minimally displaced. Management was by cerclage wiring (12), bone graft and cerclage (two), further impaction (two), and the use of cement (three), with no change from our standard postoperative management and rehabilitation. Eighteen patients had excellent or good results with an average Harris hip score of 93. Radiographically, all but one patient had Engh stability-fixation scores consistent with stable bone ingrowth. We conclude that hoop-stress fractures of the proximal femur, properly managed, do not detract from the results of total hip arthroplasty.
Total hip replacement using porous-coated cobalt-chrome femoral implants designed for biological fixation has been evaluated in 307 patients after two years and in 89 patients after five years. Histological study of 11 retrieved specimens showed bone ingrowth in nine and fibrous tissue fixation in two. Fixation by bone ingrowth occurred in 93% of the cases in which a press fit of the stem at the isthmus was achieved, but in only 69% of those without a press fit. The clinical results at two years were excellent. The incidence of pain and limp was much lower when there was either a press fit of the stem or radiographic evidence of bone ingrowth. Factors such as age, sex, and the disease process did not influence the clinical results. Most cases showed only slight resorptive remodelling of the upper femur, but in a few cases with a larger, more rigid stem, more extensive bone loss occurred. The results after five years showed no deterioration with time. Fixation by the ingrowth of bone or of fibrous tissue both appeared to be stable, but bone ingrowth gave better clinical results.
Matrix metalloproteinases (MMPs) may have a role in the process of aseptic loosening. Doxycycline has been shown to inhibit MMPs. Our aim was to investigate the potential pharmacological effect of doxycycline on aseptic loosening. We used radiolabelled mouse calvariae cultured with human interface membrane cells from aseptically loosened hips. Bone resorption was confirmed in this model. The effect of doxycycline was assessed by culturing dead radiolabelled bone discs with cells from the interface membrane with doxycycline. The control group consisted of the same culture system without doxycycline. Supernatant 45calcium and the total 45calcium remaining in the bone discs at the completion of the culture were used to measure osteolysis. We found that doxycycline can inhibit osteolysis at the interface membrane of aseptically loosened hips. This may have therapeutic implications for the treatment of patients with aseptic loosening of total joint replacements.
Aims. Current diagnostic tools are not always able to effectively identify periprosthetic joint infections (PJIs). Recent studies suggest that circulating microRNAs (miRNAs) undergo changes under pathological conditions such as infection. The aim of this study was to analyze miRNA expression in
We determined the midterm survival, incidence
of peri-prosthetic fracture and the enhancement of the width of
the femur when combining struts and impacted bone allografts in
24 patients (25 hips) with severe femoral bone loss who underwent
revision hip surgery. The pre-operative diagnosis was aseptic loosening
in 16 hips, second-stage reconstruction in seven, peri-prosthetic
fracture in one and stem fracture in one hip. A total of 14 hips
presented with an Endoklinik grade 4 defect and 11 hips a grade
3 defect. The mean pre-operative Merle D’Aubigné and Postel score
was 5.5 points (1 to 8). The survivorship was 96% (95% confidence interval 72 to 98) at
a mean of 54.5 months (36 to 109). The mean functional score was
17.3 points (16 to 18). One patient in which the strut did not completely
bypass the femoral defect was further revised using a long cemented
stem due to peri-prosthetic fracture at six months post-operatively.
The mean subsidence of the stem was 1.6 mm (1 to 3). There was no
evidence of osteolysis, resorption or radiolucencies during follow-up
in any hip. Femoral width was enhanced by a mean of 41% (19% to
82%). A total of 24 hips had partial or complete bridging of the
strut allografts. This combined biological method was associated with a favourable
survivorship, a low incidence of peri-prosthetic fracture and enhancement
of the width of the femur in revision total hip replacement in patients
with severe proximal femoral bone loss.
Aims. Elevated blood cobalt levels secondary to metal-on-metal (MoM)
Aims. Professional dancers represent a unique patient population in the setting of
Aims. This study investigates the use of the metabolic equivalent of task (MET) score in a young
Aims. Hip and knee arthroplasty is commonly performed for end-stage arthritis. There is limited information to guide golfers on the impact this procedure will have postoperatively. This study aimed to determine the impact of lower limb arthroplasty on amateur golfer performance and return to play. Methods. A retrospective observational study was designed to collect information from golfers following arthroplasty. Data were collected from 18 April 2019 to 30 April 2019 and combined a patient survey with in-app handicap data. Results. A total of 2,198 responses were analyzed (1,097 hip and 1,101 knee). Of the respondents, 1,763 (80%) were male and the mean age was 70 years (26 to 92).
Aims. To assess the feasibility of a randomized controlled trial (RCT) that compares three treatments for acetabular fractures in older patients: surgical fixation, surgical fixation and
Aims. A substantial fraction of patients undergoing knee arthroplasty (KA) or