Advertisement for orthosearch.org.uk
Results 181 - 200 of 423
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 680 - 686
1 Jun 2022
Robinson JR Bruce D Davies H Porteous AJ Murray JRD Howells NR

Aims

The best surgical strategy for the management of displaced bucket-handle (BH) meniscal tears in an anterior cruciate ligament (ACL)-deficient knee is unclear. Combining meniscal repair with ACL reconstruction (ACLR) is thought to improve meniscal healing rates; however, patients with displaced BH meniscal tears may lack extension. This leads some to advocate staged surgery to avoid postoperative stiffness and loss of range of motion (ROM) following ACLR.

Methods

We reviewed the data for a consecutive series of 88 patients (mean age 27.1 years (15 to 49); 65 male (74%) and 23 female (26%)) who underwent single-stage repair of a displaced BH meniscal tear (67 medial (76%) and 21 lateral (24%)) with concomitant hamstring autograft ACLR. The patient-reported outcome measures (PROMs) EuroQol visual analogue scale (EQ-VAS), EuroQol five-dimension health questionnaire (EQ-5D), Knee injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee score (IKDC), and Tegner score were recorded at final follow-up. A Kaplan-Meier survival analysis was performed to estimate meniscal repair survivorship. Analyses were performed with different cut-offs for meniscal and ACL injury-to-surgery time (within three weeks, three to ten weeks, and more than ten weeks).


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1285 - 1286
1 Sep 2011
Baker JF Vioreanu MH Khan HA

A variety of materials were used for early hip prostheses. The introduction of Vitallium by Smith-Petersen represented a further advance in this surgical field. We present the longest known follow-up of a Smith-Petersen Vitallium mould arthroplasty.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1202 - 1207
1 Sep 2016
Jeyaseelan L Chandrashekar S Mulligan A Bosman HA Watson AJS

Aims

The mainstay of surgical correction of hallux valgus is first metatarsal osteotomy, either proximally or distally. We present a technique of combining a distal chevron osteotomy with a proximal opening wedge osteotomy, for the correction of moderate to severe hallux valgus.

Patients and Methods

We reviewed 45 patients (49 feet) who had undergone double osteotomy. Outcome was assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) and the Short Form (SF) -36 Health Survey scores. Radiological measurements were undertaken to assess the correction.

The mean age of the patients was 60.8 years (44.2 to 75.3). The mean follow-up was 35.4 months (24 to 51).


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1085 - 1089
1 Aug 2010
Goddard NJ Mann HA Lee CA

Haemophilia is an x-linked inherited bleeding disorder which can cause severe arthropathy. We have reviewed the results of 70 primary total knee replacements (TKR) performed in 57 haemophilic patients between 1983 and 2007. The functional results were assessed using the Hospital for Special Surgery (HSS) knee scoring system and Kaplan-Meier survivorship analysis. Six patients died. HSS scores were available for 60 TKRs at a mean follow-up of 9.2 years (2 to 23); 57 (95%) had good or excellent results. Deep infection was recorded in one patient. Kaplan-Meier analysis using infection and aseptic loosening as endpoints showed the survival rate at 20 years to be 94.0%.

A reduction in infection, spontaneous haemarthrosis and improvement in the quality of life were noted to justify surgery in our series of patients with a mean age of 43 (25 to 70). We have found that using the latest techniques of continuous infusion of clotting Factor have significantly helped to reduce the complication rates and have achieved results which match those of the non-haemophilic population undergoing TKR.


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 2 | Pages 273 - 279
1 May 1965
El-Sharkawi AH Fattah HA

1. A method of treatment of displaced supracondylar fractures of the humerus in children by manipulative reduction and fixation in plaster in full extension of the elbow and supination of the forearm is described.

2. The method is easy, safe and requires a short period of hospitalisation. The carrying angle at the elbow can only be recorded, controlled and maintained when the elbow is extended and the forearm is fully supinated. Thus cubitus varus can be avoided.

3. The results of treatment in seventy-two displaced fractures treated by this method are reported.

4. Treatment by other methods is reviewed.


The Journal of Bone & Joint Surgery British Volume
Vol. 33-B, Issue 2 | Pages 231 - 239
1 May 1951
Müller GM Sissons HA

A case is described in which a clinical diagnosis of "metaphysial dysostosis" was made, but in which histological examination of involved bones showed the changes of rickets, presumably renal, with secondary hyperparathyroidism.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 499 - 503
1 May 2003
Aebli N Krebs J Schwenke D Stich H Schawalder P Theis J

We carried out a histological study of a proximally hydroxyapatite (HA)-coated femoral component, retrieved after 9.5 years of good function. The HA coating had completely degraded. Bone was in direct contact with the titanium surface in all the areas which had been coated, with no interposing fibrous tissue. There were no signs of particles, third-body wear, adverse tissue reactions or osteolysis. Bone remodelling was evident by the presence of resorption lacunae; tetracycline labelling showed bone laid down six years after implantation. The loss of the HA-coating had no negative effect on the osseo-integration of the stem. We conclude that the HA coating contributes to the fixation of the implant and that its degradation does not adversely affect the long-term fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 979 - 987
1 Sep 2001
Hamadouche M Witvoet J Porcher R Meunier A Sedel L Nizard R

We have carried out a prospective, randomised study designed to compare the long-term stability of the stem of cementless femoral implants with differing surface configurations. A total of 50 hips (46 patients) was randomised into two groups, according to whether the medullary stem had been grit blasted (GB) or coated with hydroxyapatite (HA). Both femoral prostheses were of the same geometrical design. We used Ein Bild Roentgen Analyse femoral component analysis (EBRA-FCA) to assess the stability of the stem. The mean follow-up was for 8.66 years. The mean migration of the stem was 1.26 mm in the HA group compared with 2.57 mm in the GB group (Mann-Whitney U test, p = 0.04). A mixed model ANOVA showed that the development of subsidence was statistically different in the two groups during the first 24 months. After this subsidence increased in both groups with no difference between them. Our results indicate that, with the same design of stem, HA coating enhanced the stability of the femoral stem when compared with GB stems


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 387 - 391
1 Apr 2002
Sandén B Olerud C Petrén-Mallmin M Larsson S

We investigated the effects of hydroxyapatite (HA) coating on the purchase of pedicle screws. A total of 23 consecutive patients undergoing lumbar fusion was randomly assigned to one of three treatment groups. The first received uncoated stainless-steel screws, the second screws which were partly coated with HA, and the third screws which were fully coated. The insertion torque was recorded. After 11 to 16 months, 21 screws had been extracted. The extraction torque was recorded. Radiographs were taken to assess fusion and to detect loosening of the screws. At removal, the extraction torques exceeded the upper limit of the torque wrench (600 Ncm) for many HA-coated screws. The calculated mean extraction torque was 29 ± 36 Ncm for the uncoated group, 447 ± 114 Ncm for the partly-coated group and 574 ± 52 Ncm for the fully-coated group. There were significant differences between all three groups (p < 0.001). There were more radiolucent zones surrounding the uncoated screws than the HA-coated screws (p < 0.001). HA coating of pedicle screws resulted in improved fixation with reduced risk of loosening of the screws


Aims

Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of tibial plateau fractures.

Methods

A structured search of MEDLINE, EMBASE, the online archives of Bone & Joint Publishing, and CENTRAL databases from inception until 28 July 2021 was performed. Randomized, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture nonunion, or chondral defects were excluded. Outcome data were assessed using the Risk of Bias 2 (ROB2) framework and synthesized in random-effect meta-analysis. The Preferred Reported Items for Systematic Review and Meta-Analyses guidance was followed throughout.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 87 - 97
1 Jan 2021
Burssens A De Roos D Barg A Welck MJ Krähenbühl N Saltzman CL Victor J

Aims

Patients with a deformity of the hindfoot present a particular challenge when performing total knee arthroplasty (TKA). The literature contains little information about the relationship between TKA and hindfoot alignment. This systematic review aimed to determine from both clinical and radiological studies whether TKA would alter a preoperative hindfoot deformity and whether the outcome of TKA is affected by the presence of a postoperative hindfoot deformity.

Methods

A systematic literature search was performed in the databases PubMed, EMBASE, Cochrane Library, and Web of Science. Search terms consisted of “total knee arthroplasty/replacement” combined with “hindfoot/ankle alignment”. Inclusion criteria were all English language studies analyzing the association between TKA and the alignment of the hindfoot, including the clinical or radiological outcomes. Exclusion criteria consisted of TKA performed with a concomitant extra-articular osteotomy and case reports or expert opinions. An assessment of quality was conducted using the modified Methodological Index for Non-Randomized Studies (MINORS). The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines and registered in the PROSPERO database (CRD42019106980).


Bone & Joint 360
Vol. 10, Issue 2 | Pages 24 - 26
1 Apr 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 508 - 512
1 May 1998
Hobby JL Lyall HA Meggitt BF

We report a long-term follow-up of abduction-extension osteotomy of the first metacarpal, performed for painful trapeziometacarpal osteoarthritis. Of a consecutive series of 50 operations, 41 thumbs (82%) were reviewed at a mean follow-up of 6.8 years. Good or excellent pain relief was achieved in 80%, and 93% considered that surgery had improved hand function, while 82% had normal grip and pinch strength, with restoration of thumb abduction. Metacarpal osteotomy was equally successful in relieving symptoms of those with early (grade 2) and moderate (grade 3) degenerative changes. This simple procedure provides lasting pain relief, corrects adduction contracture and restores grip and pinch strength, giving good results with few complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 1 | Pages 96 - 102
1 Feb 1972
Taylor AR Arden GP Rainey HA

1. The results have been reviewed of forty-two traumatic dislocations of the knee in forty-one patients, twenty-six of which were treated conservatively.

2. Primary operative repair was carried out in only three cases, although a further ten had operative intervention for various complications.

3. It was not possible to compare the results of operation with those of conservative treatment, because the operative procedures were so diverse in nature.

4. The conservative treatment of twenty-six dislocations yielded surprisingly good results with regard to stability, absence of pain, and range of flexion movement.

5. In general, immobilisation for long periods, like operative repair, led to reduced movement.

6. In the absence of complications, conservative treatment is the method of choice.


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 1 | Pages 157 - 180
1 Feb 1965
Lee WR Marshall JH Sissons HA

1. In two dogs, approximately one to two years and three to four months of age, an experimental comparison was made between the calcium accretion rate as defined by the Bauer-Carlsson-Lindquist equation, and the bone formation rate determined by double tetracycline labelling.

2. The overall calcium accretion rate was determined from the specific activity of the blood plasma, and the urinary and faecal excretion of isotope, following an intravenous tracer dose of Ca45. A time of five days after injection was used for the calculation of accretion rates, but data for shorter times of calculation are included.

3. Local accretion rates were obtained for different parts of the skeleton by determining the specific activities of bone samples at the end of the experiment.

4. The amount of isotope the uptake of which was not related to new bone formation (the diffuse component) was determined autoradiographically.

5. Local values for appositional growth rate and bone formation rate were obtained, using sections of undecalcified bone specimens, by measuring the linear separation between two tetracycline bone markers and the area of new bone enclosed by them.

6. In the older dog, the measurements for cortical bone showed that the accretion rate was two to three times as great as the bone formation rate: the observed diffuse component was sufficient to account for the greater part of this difference. Measurement of the bone formation rate for cancellous bone presented difficulties, but the approximate values obtained suggested that the accretion rate and the bone formation rate were of about the same order for this tissue.

7. In the younger dog, the bone formation rate could be determined only in cortical bone: at the sites studied, the values for the accretion rate and the bone formation rate did not differ by more than 20 per cent. It is suggested that this is due partly to the low specific activity of the diffuse component in this young animal, and partly to the relatively large amounts of new bone formed during the period of the experiment.

8. Despite the important differences between the rates of calcium accretion and bone formation that were found to exist in regions where there was only a small amount of new bone formation, there was a strong correlation between the two rates. The value of the accretion rate as a parameter of bone metabolism is clear.


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 4 | Pages 622 - 629
1 Nov 1954
Cameron JAP Young WB Sissons HA

1. Details of clinical, radiological, biochemical and histological investigations of a case of metaphysial dysostosis are presented.

2. The patient was a boy of seven years, and showed widespread lesions (involving long bones of limbs, small bones of hands and feet, pelvis, clavicles, and ribs) characterised by retardation of growth and ossification with masses of partly calcified tissue in the metaphyses.

3. No radiological, clinical or histological evidence of renal osteodystrophy was found in the case described.

4. Metaphysial dysostosis is discussed in relation to other chondrodystrophies.


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 3 | Pages 428 - 435
1 Aug 1954
Golding JSR St Andrew Sissons HA

Two cases of benign osteoblastic tumours of the spine, occurring in young patients, and presenting as expanding osteolytic lesions with some central calcification and ossification, are described. It is suggested that they represent a condition allied to, but usefully separated from, osteoid osteoma of bone. The name osteogenic fibroma of bone, proposed by Lichtenstein for this type of case, is accepted.


Bone & Joint 360
Vol. 10, Issue 2 | Pages 26 - 28
1 Apr 2021


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 50 - 55
1 Jan 2015
Zuiderbaan HA Khamaisy S Thein R Nawabi DH Pearle AD

Progressive degenerative changes in the medial compartment of the knee following lateral unicompartmental arthroplasty (UKA) remains a leading indication for revision surgery. The purpose of this study is to evaluate changes in the congruence and joint space width (JSW) of the medial compartment following lateral UKA. The congruence of the medial compartment of 53 knees (24 men, 23 women, mean age 13.1 years; sd 62.1) following lateral UKA was evaluated pre-operatively and six weeks post-operatively, and compared with 41 normal knees (26 men, 15 women, mean age 33.7 years; sd 6.4), using an Interactive closest point algorithm which calculated the congruence index (CI) by performing a rigid transformation that best aligns the digitised tibial and femoral surfaces. Inner, middle and outer JSWs were measured by sub-dividing the medial compartment into four quarters on pre- and post-operative, weight bearing tunnel view radiographs. The mean CI of knees following lateral UKA significantly improved from 0.92 (sd 0.06) pre-operatively to 0.96 (sd 0.02) (p < 0.001) six weeks post-operatively. The mean CI of the healthy control group was 0.99 sd 0.01. Post-operatively, the mean inner JSW increased (p = 0.006) and the outer decreased (p = 0.002). The JSW was restored post-operatively as no significant differences were noted in all three locations compared with the control group (inner JSW p = 0.43; middle JSW p = 0.019, outer JSW p = 0.51).

Our data suggest that a well conducted lateral UKA may improve the congruence and normalise the JSW of the medial compartment, potentially preventing progression of degenerative change.

Cite this article: Bone Joint J 2015;97-B:50–5.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1550 - 1555
1 Nov 2011
Hill RA Ibrahim T Mann HA Siapkara A

We present our experience of forearm lengthening in children with various conditions performed by a single surgeon between 1995 and 2009. A total of 19 children with a mean age of 9.8 years (2.1 to 15.9) at the time of surgery had 22 forearm lengthenings using either an Ilizarov/spatial and Ilizarov circular frame or a monolateral external fixator. The patients were divided into two groups: group A, in whom the purpose of treatment was to restore the relationship between the radius and the ulna, and group B, in whom the objective was to gain forearm length. The mean follow-up after removal of the frame was 26 months (13 to 53).

There were ten patients (11 forearms) in group A with a mean radioulnar discrepancy of 2.4 cm (1.5 to 3.3) and nine patients (11 forearms) in group B. In group A, the mean lengthening achieved was 2.7 cm (1.0 to 5.5), with a lengthening index of 11.1 weeks/cm. Equalisation or overcorrection of the discrepancy was achieved in seven of 11 forearms, but lengthening was only partially successful at preventing subluxation or dislocation of the radial head. In group B, the mean lengthening achieved was 3.8 cm (1.9 to 6.8), with a lengthening index of 7.25 weeks/cm. Common complications in both groups were pin-site infection and poor regenerate formation.

Forearm lengthening by distraction osteogenesis is a worthwhile procedure in children that can improve cosmesis and function, particularly in patients with shortening of both radius and ulna.