Advertisement for orthosearch.org.uk
Results 181 - 200 of 618
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 2 | Pages 292 - 297
1 May 1965
Parker D Chapman R

1. A case of hydatidosis of the innominate bone is described. 2. The disease was treated by local resection combined with instillation of supersaturated salt solution. 3. The disease appears to have been arrested and the functional result is good. 4. The lethal effect of supersaturated salt solution on the parasite is stressed. 5. The experience of other workers in the field of hydatid disease is described


The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 2 | Pages 351 - 359
1 May 1963
Lowe HG

1. The problem of gap defects in the forearm bones and its solution by radio-ulnar fusion is discussed. 2. Seven patients with radio-ulnar fusions are presented. In four patients the operation was done for defects in the ulna, in two for defects in the radius, and in one for non-union of the radius and ulna after fracture. 3. The good cosmetic and functional result after radio-ulnar fusion is emphasised


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 362 - 364
1 May 1992
Herscovici D Fiennes A Allgower M Ruedi T

In ipsilateral mid-clavicular and scapular-neck fractures, the mechanical stability of the suspensory structures is disrupted and muscle forces and the weight of the arm pull the glenoid fragment distally and anteromedially. To prevent late deformity we recommend internal fixation of the fractured clavicle by a plate and screws. We treated seven patients with this unusual injury; all achieved an excellent functional result without deformity


The Journal of Bone & Joint Surgery British Volume
Vol. 41-B, Issue 2 | Pages 365 - 368
1 May 1959
Clark K

1. A case of giant-cell tumour of the proximal end of the humerus treated by resection and fibular grafting twenty-nine years ago is reported. An excellent functional result has been maintained. 2. The literature is reviewed and the results claimed by earlier workers are noted. 3. The present field of application of the operation is probably in cases of advanced or recurrent giant-cell tumour of bone


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 461 - 464
1 May 1991
Twyman R Desai K Aichroth P

Twenty-two knees with osteochondritis dissecans diagnosed before skeletal maturity were followed prospectively into middle age: 32% had radiographic evidence of moderate or severe osteoarthritis at an average follow-up of 33.6 years; only half had a good or excellent functional result. We found that osteoarthritis was more likely to occur if the defect was large or affected the lateral femoral condyle


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1107 - 1114
1 Sep 2019
Uy M Wang J Horner NS Bedi A Leroux T Alolabi B Khan M

Aims

The aim of this study was to evaluate the differences in revision and complication rates, functional outcomes, and radiological outcomes between cemented and press-fit humeral stems in primary anatomical total shoulder arthroplasty (TSA).

Materials and Methods

A comprehensive systematic review and meta-analysis was conducted searching for studies that included patients who underwent primary anatomical TSA for primary osteoarthritis or rheumatoid arthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1162 - 1166
1 Nov 2002
Tsuchiya H Abdel-Wanis ME Sakurakichi K Yamashiro T Tomita K

In 11 patients juxta-articular osteosarcoma around the knee was treated by intraepiphyseal excision of the tumour and reconstruction of the bone defect by distraction osteogenesis. Preoperative and postoperative chemotherapy was given to eight patients with high-grade tumours. The articular cartilage of the epiphysis and a maximum of healthy soft tissues were preserved. Distraction osteogenesis was then carried out. The mean gain in length was 9.7 cm. Full function of the limb was preserved in all except one patient, with a mean follow-up of 53.8 months. Treatment of juxta-articular osteosarcomas around the knee with joint preservation and biological reconstruction using distraction osteogenesis can give excellent functional results


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 943 - 946
1 Nov 1994
Stranks G Cecil T Jeffery I

We report a new method of ankle arthrodesis which combines an anterior approach with a dowel technique of bone grafting and screw fixation. In 20 ankles of 20 patients, ten with osteoarthritis, eight with rheumatoid arthritis and two others, we achieved 19 solid bony fusions and one painless fibrous ankylosis. The average time to union was 12.5 weeks. Patient satisfaction was high and the functional results were as good as for other reported methods, with fewer complications


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 58 - 60
1 Jan 1993
Roysam G

The effect of involvement of the distal radio-ulnar joint on subsequent function was studied in 170 patients with Colles' fractures, reviewed for one year after cast removal. Patients with involvement of this joint had significantly weaker grips and a significantly greater incidence of pain and tenderness over the joint at all stages of follow-up. They also had a poorer range of supination at six months and at one year. The presence or absence of an ulnar styloid fracture was not related to the functional results


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 325 - 327
1 Mar 1998
Hui JHP De SD Balasubramaniam P

Recurrent dislocation of peroneal tendons is uncommon and there are few reports of the long-term results after repair. The Singapore operation, first described in 1985, is an anatomical repair based on the Bankart-like lesion seen in the superior peroneal retinaculum. We reviewed 21 patients after a mean follow-up of 9.3 years, and found no recurrence. Eighteen had good functional results and had returned to their previous levels of vocational and sports activities. The three fair results were due to painful scars or neuromas


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 199 - 203
1 Mar 2001
Dennison MG Pool RD Simonis RB Singh BS

Between 1994 and 1999, we treated six patients with avascular necrosis of the talus by excision of the necrotic body of the talus and tibiocalcaneal fusion using an Ilizarov frame. This was combined with corticotomy and a lengthening procedure. Shortening was corrected in all patients except two, who were over 60 years of age. All patients had previous operations which had failed. All achieved solid bony fusion, with five out of six having either a good or an excellent result. We conclude that this is an effective reconstructive technique which gives a good functional result


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 691 - 695
1 Sep 1995
Dent C Hoy G Stanley J

We reviewed 25 patients with rheumatoid arthritis who had failure of 26 primary total elbow arthroplasties causing pain and loss of function. Most revision cases required special custom implants to treat varying bone loss and soft-tissue disruption. Assessment showed satisfactory functional results in the patients treated by revision at a mean follow-up period of 35 months. Our review suggests that revision surgery produces short- to medium-term painfree function, and is the treatment of choice for a failed total elbow arthroplasty in the absence of infection


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 651 - 658
1 May 2007
Day AC Kinmont C Bircher MD Kumar S

Crescent fracture dislocations are a well-recognised subset of pelvic ring injuries which result from a lateral compression force. They are characterised by disruption of the sacroiliac joint and extend proximally as a fracture of the posterior iliac wing. We describe a classification with three distinct types. Type I is characterised by a large crescent fragment and the dislocation comprises no more than one-third of the sacroiliac joint, which is typically inferior. Type II fractures are associated with an intermediate-size crescent fragment and the dislocation comprises between one- and two-thirds of the joint. Type III fractures are associated with a small crescent fragment where the dislocation comprises most, but not all of the joint. The principal goals of surgical intervention are the accurate and stable reduction of the sacroiliac joint. This classification proves useful in the selection of both the surgical approach and the reduction technique. A total of 16 patients were managed according to this classification and achieved good functional results approximately two years from the time of the index injury. Confounding factors compromise the summary short-form-36 and musculoskeletal functional assessment instrument scores, which is a well-recognised phenomenon when reporting the outcome of high-energy trauma


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 851 - 857
1 Jun 2005
Davidson AW Hong A McCarthy SW Stalley PD

We treated 50 patients with bony malignancy by en-bloc resection, extracorporeal irradiation with 50 Gy and re-implantation of the bone segment. The mean survivor follow-up was 38 months (12 to 92) when 42 patients were alive and without disease. There were four recurrences. The functional results were good according to the Mankin score (17 excellent, 13 good, nine fair, three failures), the Musculoskeletal Tumour Society score (mean 77) and the Toronto Extremity Salvage score (mean 81). There was solid union, but bone resorption was seen in some cases. The dose of radiation was lethal to all cells and produced a dead autograft of perfect fit. Extracorporeal irradiation is a useful technique for limb salvage when there is reasonable residual bone stock. It allows effective re-attachment of tendons and produces a lasting biological reconstruction. There should be no risk of local recurrence or of radiotherapy-induced malignancy in the replanted bone


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 774 - 776
1 Nov 1989
Spencer R

Retrospective review of 25 patients over 65 years of age with unilateral acetabular fractures managed conservatively showed that seven of the 23 survivors (30%) had an unacceptable functional result. Poor results were associated with: displaced posterior column fractures, osteoporosis, femoral head fracture, delayed diagnosis, inadequate radiographs, inappropriate or too brief traction, and early weight-bearing. In this age group acetabular fractures tend to be low-velocity injuries of osteoporotic bone and are not comparable with those in younger patients


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 3 | Pages 398 - 403
1 Aug 1964
Williams G

1. Fifteen cases of bone transplantation for fibrous union of fractures of long bones are described, using boiled minced cancellous bone from cadavers. One transplant became infected but the infection responded to treatment. 2. In one patient with non-union of the shaft of the humerus, bony union was not obtained, but a good functional result obviated further treatment. 3. It is suggested that this relatively simple method of bone transplantation could be used more widely if its potentialities were appreciated more fully


The Journal of Bone & Joint Surgery British Volume
Vol. 33-B, Issue 1 | Pages 65 - 73
1 Feb 1951
Penrose JH

1. The posterior Monteggia fracture usually conforms to a typical pattern. 2. Its incidence is greatest among middle-aged women. 3. The mechanism of the injury is probably similar to that of the dislocated elbow. Excessive rotation of the forearm plays no part in its production. 4. Internal fixation of the ulna combined with excision of the whole radial head, or of its detached segment, is suggested as the treatment of choice. 5. The functional results after operation are excellent, but some slight permanent restriction of movement is to be expected


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 833 - 837
1 Sep 1991
Barrett D

We have assessed 45 patients who had undergone anterior cruciate reconstruction by a modified MacIntosh-Jones method. The results, using standard knee scores and clinical ligament testing, correlated poorly with the patient's own opinion and with the functional result. However, measurement of proprioception in the knee correlated well with both function (r = 0.84) and with patient satisfaction (r = 0.9). This study indicates that proprioception, rather than the clinical excellence of the repair, is a major factor in the outcome of anterior cruciate ligament reconstruction


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 147 - 150
1 Jan 1986
Calvert P Packer N Stoker D Bayley J Kessel L

Double-contrast shoulder arthrograms were performed in 20 patients at an average of 30 months after operative repair of a torn rotator cuff. In 18 out of 20 shoulders the contrast medium leaked into the subacromial bursa indicating a defect in the rotator cuff. Despite this, 17 patients had complete relief of pain and 15 had a full range of shoulder elevation. The results suggest that a completely watertight closure is not essential for a good functional result, and that arthrography may not be helpful in the investigation of failure of repair


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 4 | Pages 646 - 659
1 Nov 1966
Ottolenghi CE

1. Seven cases of massive osteoarticular transplant for conditions affecting major joints are described. In one case the whole femur was replaced. 2. The transplants were well accepted, though there was a varying degree of absorption of bone and necrosis of articular cartilage. 3. The functional results were very satisfactory, and movements of joints were well preserved. 4. In these cases recurrence of the original disease was not seen. 5. Such operations are still in an experimental stage, but they are likely to have a permanent place in treatment in certain carefully selected cases