Advertisement for orthosearch.org.uk
Results 1 - 20 of 32
Results per page:

Aims. Olecranon fractures are usually caused by falling directly on to the olecranon or following a fall on to an outstretched arm. Displaced fractures of the olecranon with a stable ulnohumeral joint are commonly managed by open reduction and internal fixation. The current predominant method of management of simple displaced fractures with ulnohumeral stability (Mayo grade IIA) in the UK and internationally is a low-cost technique using tension band wiring. Suture or suture anchor techniques have been described with the aim of reducing the hardware related complications and reoperation. An all-suture technique has been developed to fix the fracture using strong synthetic sutures alone. The aim of this trial is to investigate the clinical and cost-effectiveness of tension suture repair versus traditional tension band wiring for the surgical fixation of Mayo grade IIA fractures of the olecranon. Methods. SOFFT is a multicentre, pragmatic, two-arm parallel-group, non-inferiority, randomized controlled trial. Participants will be assigned 1:1 to receive either tension suture fixation or tension band wiring. 280 adult participants will be recruited. The primary outcome will be the Disabilities of the Arm, Shoulder and Hand (DASH) score at four months post-randomization. Secondary outcome measures include DASH (at 12, 18, and 24 months), pain, Net Promotor Score (patient satisfaction), EuroQol five-dimension five-level score (EQ-5D-5L), radiological union, complications, elbow range of motion, and re-operations related to the injury or to remove metalwork. An economic evaluation will assess the cost-effectiveness of treatments. Discussion. There is currently no high-quality evidence comparing the clinical and cost effectiveness of the tension suture repair to the traditional tension band wiring currently offered for the internal fixation of displaced fractures of the olecranon. The Simple Olecranon Fracture Fixation Trial (SOFFT) is a randomized controlled trial with sufficient power and design rigour to provide this evidence for the subtype of Mayo grade IIA fractures. Cite this article: Bone Jt Open 2023;4(1):27–37


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 245 - 250
1 Feb 2011
Wilson J Bajwa A Kamath V Rangan A

Compression and absolute stability are important in the management of intra-articular fractures. We compared tension band wiring with plate fixation for the treatment of fractures of the olecranon by measuring compression within the fracture. Identical transverse fractures were created in models of the ulna. Tension band wires were applied to ten fractures and ten were fixed with Acumed plates. Compression was measured using a Tekscan force transducer within the fracture gap. Dynamic testing was carried out by reproducing cyclical contraction of the triceps of 20 N and of the brachialis of 10 N. Both methods were tested on each sample. Paired t-tests compared overall compression and compression at the articular side of the fracture. The mean compression for plating was 819 N (. sd. 602, 95% confidence interval (CI)) and for tension band wiring was 77 N (. sd. 19, 95% CI) (p = 0.039). The mean compression on the articular side of the fracture for plating was 343 N (. sd. 276, 95% CI) and for tension band wiring was 1 N (. sd. 2, 95% CI) (p = 0.038). During simulated movements, the mean compression was reduced in both groups, with tension band wiring at −14 N (. sd. 7) and for plating −173 N (. sd. 32). No increase in compression on the articular side was detected in the tension band wiring group. Pre-contoured plates provide significantly greater compression than tension bands in the treatment of transverse fractures of the olecranon, both over the whole fracture and specifically at the articular side of the fracture. In tension band wiring the overall compression was reduced and articular compression remained negligible during simulated contraction of the triceps, challenging the tension band principle


Bone & Joint 360
Vol. 3, Issue 4 | Pages 25 - 28
1 Aug 2014

The August 2014 Trauma Roundup. 360 . looks at: On-table CT for calcaneal fractures; timing of femoral fracture surgery and outcomes; salvage arthroplasty for failed internal fixation of the femoral neck; screw insertion in osteoporotic bone; fibular intramedullary nailing on the ascendant; posterior wall acetabular fractures not all that innocent; bugs, plating and resistance and improving outcomes in olecranon tension band wiring


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 280 - 282
1 Mar 1990
Curtis M

Cadaveric experiments in 10 knees were used to study the strength of two methods of internal fixation for a fractured patella. A modified AO tension band technique was compared with the combination of cerclage wiring and a tension band used at Pyrford. The repairs were stressed to failure; the combination of cerclage and tension band wiring proved to be significantly stronger and is recommended


Bone & Joint 360
Vol. 13, Issue 1 | Pages 26 - 29
1 Feb 2024

The February 2024 Shoulder & Elbow Roundup360 looks at: Does indomethacin prevent heterotopic ossification following elbow fracture fixation?; Arthroscopic capsular shift in atraumatic shoulder joint instability; Ultrasound-guided lavage with corticosteroid injection versus sham; Combined surgical and exercise-based interventions following primary traumatic anterior shoulder dislocation: a systematic review and meta-analysis; Are vascularized fibula autografts a long-lasting reconstruction after intercalary resection of the humerus for primary bone tumours?; Anatomical versus reverse total shoulder arthroplasty with limited forward elevation; Tension band or plate fixation for simple displaced olecranon fractures?; Is long-term follow-up and monitoring in shoulder and elbow arthroplasty needed?


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 942 - 948
1 Sep 2024
Kingery MT Kadiyala ML Walls R Ganta A Konda SR Egol KA

Aims

This study evaluated the effect of treating clinician speciality on management of zone 2 fifth metatarsal fractures.

Methods

This was a retrospective cohort study of patients with acute zone 2 fifth metatarsal fractures who presented to a single large, urban, academic medical centre between December 2012 and April 2022. Zone 2 was the region of the fifth metatarsal base bordered by the fourth and fifth metatarsal articulation on the oblique radiograph. The proportion of patients allowed to bear weight as tolerated immediately after injury was compared between patients treated by orthopaedic surgeons and podiatrists. The effects of unrestricted weightbearing and foot and/or ankle immobilization on clinical healing were assessed. A total of 487 patients with zone 2 fractures were included (mean age 53.5 years (SD 16.9), mean BMI 27.2 kg/m2 (SD 6.0)) with a mean follow-up duration of 2.57 years (SD 2.64).


Bone & Joint Research
Vol. 12, Issue 8 | Pages 504 - 511
23 Aug 2023
Wang C Liu S Chang C

Aims

This study aimed to establish the optimal fixation methods for calcaneal tuberosity avulsion fractures with different fragment thicknesses in a porcine model.

Methods

A total of 36 porcine calcanea were sawed to create simple avulsion fractures with three different fragment thicknesses (5, 10, and 15 mm). They were randomly fixed with either two suture anchors or one headless screw. Load-to-failure and cyclic loading tension tests were performed for the biomechanical analysis.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 112 - 123
1 Feb 2023
Duckworth AD Carter TH Chen MJ Gardner MJ Watts AC

Despite being one of the most common injuries around the elbow, the optimal treatment of olecranon fractures is far from established and stimulates debate among both general orthopaedic trauma surgeons and upper limb specialists. It is almost universally accepted that stable non-displaced fractures can be safely treated nonoperatively with minimal specialist input. Internal fixation is recommended for the vast majority of displaced fractures, with a range of techniques and implants to choose from. However, there is concern regarding the complication rates, largely related to symptomatic metalwork resulting in high rates of implant removal. As the number of elderly patients sustaining these injuries increases, we are becoming more aware of the issues associated with fixation in osteoporotic bone and the often fragile soft-tissue envelope in this group. Given this, there is evidence to support an increasing role for nonoperative management in this high-risk demographic group, even in those presenting with displaced and/or multifragmentary fracture patterns. This review summarizes the available literature to date, focusing predominantly on the management techniques and available implants for stable fractures of the olecranon. It also offers some insights into the potential avenues for future research, in the hope of addressing some of the pertinent questions that remain unanswered.

Cite this article: Bone Joint J 2023;105-B(2):112–123.


Bone & Joint 360
Vol. 11, Issue 2 | Pages 27 - 30
1 Apr 2022


Bone & Joint 360
Vol. 10, Issue 3 | Pages 26 - 29
1 Jun 2021


Bone & Joint 360
Vol. 9, Issue 6 | Pages 31 - 33
1 Dec 2020


Bone & Joint Open
Vol. 1, Issue 7 | Pages 376 - 382
10 Jul 2020
Gill JR Vermuyten L Schenk SA Ong JCY Schenk W

Aims

The aim of this study is to report the results of a case series of olecranon fractures and olecranon osteotomies treated with two bicortical screws.

Methods

Data was collected retrospectively for all olecranon fractures and osteotomies fixed with two bicortical screws between January 2008 and December 2019 at our institution. The following outcome measures were assessed; re-operation, complications, radiological loss of reduction, and elbow range of flexion-extension.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 26 - 28
1 Feb 2016


Bone & Joint 360
Vol. 6, Issue 5 | Pages 21 - 24
1 Oct 2017


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 260 - 265
1 Mar 2019
Lee SH Han SS Yoo BM Kim JW

Aims

The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients.

Patients and Methods

We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH).


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1178 - 1182
1 Sep 2006
Stanley JK Penn DS Wasseem M

Surgical access to the head of the radius is usually performed through a lateral approach. We present an alternative technique through a modified posterior approach which was developed following dissections of 22 human cadavers. An osteotomy of the supinator tuberosity was performed and reflected as a single unit with the attached annular ligament. Excellent exposure of the head of the radius was achieved, replacement of the head was undertaken and the osteotomy site repaired. The elbows were stable and had a full range of movement. The approach was then carried out on 13 patients for elective replacement of the head and was found to be safe and reproducible. In the patient group all osteotomies united, the elbows were stable and had an improved range of supination and pronation. There was no change in flexion and extension of the elbow. Complications included a haematoma and a reflex sympathetic dystrophy.

The modified posterior approach provides excellent access to the head and neck of the radius, gives good stability of the elbow and allows early mobilisation of the joint.


Bone & Joint 360
Vol. 5, Issue 4 | Pages 29 - 31
1 Aug 2016


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1206 - 1209
1 Sep 2007
Moonot P Ashwood N Hamlet M

Secure fixation of displaced proximal fractures of the humerus is a challenging problem. A total of 32 patients with acutely displaced three- or four-part proximal fractures of the humerus were treated by open reduction and internal fixation using the proximal humeral internal locking system (PHILOS) plate. There were 23 women and nine men with a mean age of 59.9 years (18 to 87). Data were collected prospectively and the outcomes were assessed using the Constant score. The mean follow-up was for 11 months (3 to 24). In 31 patients (97%) the fracture united clinically and radiologically at a mean of 10 weeks (8 to 24). The mean Constant score at final review was 66.5 (30 to 92). There was no significant difference in outcome when comparing patients aged more than 60 years (18 patients) with those aged less than 60 years (14 patients) (t-test, p = 0.8443). There was one case each of nonunion, malunion and a broken screw in the elderly population.

This plate provides an alternative method of fixation for fractures of the proximal humerus. It provides a stable fixation in young patients with good-quality bone sufficient to permit early mobilisation. Failure of the screws to maintain fixation in the elderly remains a problem.


Bone & Joint 360
Vol. 4, Issue 6 | Pages 18 - 19
1 Dec 2015

The December 2015 Shoulder & Elbow Roundup360 looks at:


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1187 - 1191
1 Sep 2005
Pitts D Rowley DI Sher JL