Stable fractures of the ankle can be successfully treated non-operatively by a below-knee
We have had experience of an 18-month-old boy with a cardiomyopathy who died a few minutes after removal of his cast with a saw, apparently from a malignant cardiac arrhythmia triggered by anxiety. We therefore examined the anxiety reaction to this method of removal of a
The use of Orthoplast cast-bracing to allow early hand function in the treatment of displaced Colles' fractures was investigated in 243 patients. They were randomly allocated into three groups: in the first a conventional Colles' type plaster was used; in the second an above-elbow cast-brace with the forearm in supination; and in the third a below-elbow cast-brace. Radiographic measurements were made at each stage of treatment, and the final anatomical result was scored using Sarmiento's (1975) criteria. Function was assessed at three months and at six months. The anatomical result was not influenced by the method of immobilisation but was related to the efficacy of reduction. Loss of position in the braces was no greater than in plaster. The functional result at three months also was uninfluenced by the method of immobilisation; it was, however, related to the severity of the initial displacement, and (to a lesser degree) to the anatomical result, an effect which was lost at six months. Early hand function and the supinated position advocated by Sarmiento were found to confer no anatomical or functional advantage; we could see no reason to change from the use of conventional
Aims. The aim of this study was to compare the longer-term outcomes of operatively and nonoperatively managed patients treated with a removable brace (fixed-angle removable orthosis) or a
Rockers are applied to lower limb casts to assist walking but there is little information on their biomechanical effects. The performances of 10 commercially available rockers were compared. They were applied to a below-knee cast worn by a normal subject who was also tested walking in the cast alone. Gait analysis was used to evaluate kinematic and kinetic data. The design of rocker had no effect upon the kinematics of walking. However, using new criteria for kinetic assessment of rocker function (tibial floor angular velocity and centre of pressure progression), most designs had a deleterious effect on the biomechanics of gait. Only two rockers approached the ideal kinetic criteria.
Aims. The primary aim of this study was to report the radiological outcomes of patients with a dorsally displaced distal radius fracture who were randomized to a moulded cast or surgical fixation with wires following manipulation and closed reduction of their fracture. The secondary aim was to correlate radiological outcomes with patient-reported outcome measures (PROMs) in the year following injury. Methods. Participants were recruited as part of DRAFFT2, a UK multicentre clinical trial. Participants were aged 16 years or over with a dorsally displaced distal radius fracture, and were eligible for the trial if they needed a manipulation of their fracture, as recommended by their treating surgeon. Participants were randomly allocated on a 1:1 ratio to moulded cast or Kirschner wires after manipulation of the fracture in the operating theatre. Standard posteroanterior and lateral radiographs were performed in the radiology department of participating centres at the time of the patient’s initial assessment in the emergency department and six weeks postoperatively. Intraoperative fluoroscopic images taken at the time of fracture reduction were also assessed. Results. Patients treated with surgical fixation with wires had less dorsal angulation of the radius versus those treated in a moulded cast at six weeks after manipulation of the fracture; the mean difference of -4.13° was statistically significant (95% confidence interval 5.82 to -2.45). There was no evidence of a difference in radial shortening. However, there was no correlation between these radiological measurements and PROMs at any timepoint in the 12 months post-injury. Conclusion. For patients with a dorsally displaced distal radius fracture treated with a closed manipulation, surgical fixation with wires leads to less dorsal angulation on radiographs at six weeks compared with patients treated in a moulded
Aims. To explore individuals’ experience of a scaphoid waist fracture and its subsequent treatment. Methods. A purposive sample was created, consisting of 49 participants in the Scaphoid Waist Internal Fixation for Fractures Trial of initial surgery compared with
The aim of this study was to compare the cost-effectiveness of surgical fixation with Kirschner (K-)wire ersus moulded casting after manipulation of a fracture of the distal radius in an operating theatre setting. An economic evaluation was conducted based on data collected from the Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT2) multicentre randomized controlled trial in the UK. Resource use was collected at three, six, and 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from an NHS and personal social services perspective. Sensitivity analyses were conducted to examine the robustness of cost-effectiveness estimates, and decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves.Aims
Methods
The purpose of this study was to investigate the effects of right leg restriction at the knee, ankle or both, on a driver’s braking times. Previous studies have not investigated the effects of knee restriction on braking performance. A total of 23 healthy drivers performed a series of emergency braking tests in a driving simulator in either an above-knee
We hypothesised that adjuvant intermittent pneumatic
compression (IPC) beneath a
Objectives. The evidence base to inform the management of Achilles tendon
rupture is sparse. The objectives of this research were to establish
what current practice is in the United Kingdom and explore clinicians’
views on proposed further research in this area. This study was
registered with the ISRCTN (ISRCTN68273773) as part of a larger
programme of research. Methods. We report an online survey of current practice in the United
Kingdom, approved by the British Orthopaedic Foot and Ankle Society
and completed by 181 of its members. A total of ten of these respondents
were invited for a subsequent one-to-one interview to explore clinician
views on proposed further research in this area. Results. The survey showed wide variations in practice, with patients
being managed in
Aims. Displaced distal radius fractures were investigated at a level 1 major trauma centre during the COVID-19 2020 lockdown due to the implementation of temporary changes in practice. The primary aim was to establish if follow-up at one week in place of the 72-hour British Orthopaedic Association Standards for Trauma & Orthopaedics (BOAST) guidance was safe following manipulation under anaesthetic. A parallel adaptation during lockdown was the non-expectation of Bier’s block. The secondary aim was to compare clinical outcomes with respect to block type. Methods. Overall, 90 patients were assessed in a cross-sectional cohort study using a mixed, retrospective-prospective approach. Consecutive sampling of 30 patients pre-lockdown (P1), 30 during lockdown (P2), and 30 during post-lockdown (P3) was applied. Type of block, operative status, follow-up, and complications were extracted. Primary endpoints were early complications (≤ one week). Secondary endpoints were later complications including malunion, delayed union or osteotomy. Results. In P1, 86.6% of patients were seen between days one to three, 26.7% in P2, and 56.7% in P3. There were no documented complications from days one to three. Operative rate was 35.5%, which did not vary significantly (p= 0.712). Primary endpoints occurred between day four to seven, and included one patient each period treated for
Aims. Describe a statistical and economic analysis plan for the Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT2) randomized controlled trial. Methods. DRAFFT2 is a multicentre, parallel, two-arm randomized controlled trial. It compares surgical fixation with K-wires versus
Aims. The Ponseti method is an effective evidence-based treatment for clubfoot. It uses gentle manipulation to adjust the position of the foot in serial treatments towards a more physiological position. Casting is used to hold the newly achieved position. At first, the foot resists the new position imposed by the
Objectives. We aimed to examine the characteristics of deep venous flow in
the leg in a cast and the effects of a wearable neuromuscular stimulator
(geko; FirstKind Ltd) and also to explore the participants’ tolerance
of the stimulator. Methods. This is an open-label physiological study on ten healthy volunteers.
Duplex ultrasonography of the superficial femoral vein measured
normal flow and cross-sectional area in the standing and supine
positions (with the lower limb initially horizontal and then elevated).
Flow measurements were repeated during activation of the geko stimulator
placed over the peroneal nerve. The process was repeated after the
application of a below-knee cast. Participants evaluated discomfort
using a questionnaire (verbal rating score) and a scoring index
(visual analogue scale). Results. The geko device was effective in significantly increasing venous
blood flow in the lower limb both with a
We describe a direct method of measuring the tightness of
Deep vein thrombosis is a common complication
of immobilising the lower limb after surgery. We hypothesised that
intermittent pneumatic compression (IPC) therapy in outpatients
who had undergone surgical repair of acute ruptures of the Achilles
tendon could reduce the incidence of this problem. A total of 150 patients who had undergone surgical repair of
the Achilles tendon were randomised to either treatment with IPC
for six hours per day (n = 74) under an orthosis or treatment as
usual (n = 74) in a