Advertisement for orthosearch.org.uk
Results 1 - 14 of 14
Results per page:
Bone & Joint Research
Vol. 1, Issue 6 | Pages 118 - 124
1 Jun 2012
Grawe B Le T Williamson S Archdeacon A Zardiackas L

Objectives

We aimed to further evaluate the biomechanical characteristics of two locking screws versus three standard bicortical screws in synthetic models of normal and osteoporotic bone.

Methods

Synthetic tubular bone models representing normal bone density and osteoporotic bone density were used. Artificial fracture gaps of 1 cm were created in each specimen before fixation with one of two constructs: 1) two locking screws using a five-hole locking compression plate (LCP) plate; or 2) three non-locking screws with a seven-hole LCP plate across each side of the fracture gap. The stiffness, maximum displacement, mode of failure and number of cycles to failure were recorded under progressive cyclic torsional and eccentric axial loading.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 72 - 81
1 Jan 2023
Stake IK Ræder BW Gregersen MG Molund M Wang J Madsen JE Husebye EE

Aims

The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients.

Methods

In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims

Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery.

Methods

A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 696 - 702
1 May 2016
Theologis AA Burch S Pekmezci M

Aims. We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy. Materials and Methods. Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers. Results. There were no neuroforaminal breaches in either group. The set-up time for the O-Arm was significantly longer than for the C-Arm, while total time for placement of the screws was significantly shorter for the O-Arm than for the C-Arm (p = 0.001). The mean absorbed radiation dose during fluoroscopy was 1063 mRad (432.5 mRad to 4150 mRad). No radiation was detected on the surgeon during fluoroscopy, or when he left the room during the use of the O-Arm. The mean radiation detected on the cadavers was significantly higher in the O-Arm group (2710 mRem standard deviation (. sd. ) 1922) than during fluoroscopy (11.9 mRem . sd 14.8). (p < 0.01). Conclusion. O-Arm/Stealth Navigation allows for faster percutaneous placement of iliosacral screws in a radiation-free environment for surgeons, albeit with the same accuracy and significantly more radiation exposure to cadavers, when compared with standard fluoroscopy. Take home message: Placement of iliosacral screws with O-Arm/Stealth Navigation can be performed safely and effectively. Cite this article: Bone Joint J 2016;98-B:696–702


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1182 - 1189
1 Oct 2024
Nisar S Lamb J Johansen A West R Pandit H

Aims

To determine if patient ethnicity among patients with a hip fracture influences the type of fracture, surgical care, and outcome.

Methods

This was an observational cohort study using a linked dataset combining data from the National Hip Fracture Database and Hospital Episode Statistics in England and Wales. Patients’ odds of dying at one year were modelled using logistic regression with adjustment for ethnicity and clinically relevant covariates.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 385 - 387
1 Mar 2009
Pichler W Grechenig W Tesch NP Weinberg AM Heidari N Clement H

Percutaneous stabilisation of tibial fractures by locking plates has become an accepted form of osteosynthesis. A potential disadvantage of this technique is the risk of damage to the neurovascular bundles in the anterior and peroneal compartments. Our aim in this anatomical study was to examine the relationship of the deep peroneal nerve to a percutaneously-inserted Less Invasive Stabilisation System tibial plate in the lower limbs of 18 cadavers. Screws were inserted through stab incisions. The neurovascular bundle was dissected to reveal its relationship to the plate and screws. In all cases, the deep peroneal nerve was in direct contact with the plate between the 11th and the 13th holes. In ten specimens the nerve crossed superficial to the plate, in six it was interposed between the plate and the bone and in the remaining two specimens it coursed at the edge of the plate. Percutaneous insertion of plates with more than ten holes is not recommended because of the risk of injury to the neurovascular structures. When longer plates are required we suggest distal exposure so that the neurovascular bundle may be displayed and protected


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 775 - 781
1 Apr 2021
Mellema JJ Janssen S Schouten T Haverkamp D van den Bekerom MPJ Ring D Doornberg JN

Aims

This study evaluated variation in the surgical treatment of stable (A1) and unstable (A2) trochanteric hip fractures among an international group of orthopaedic surgeons, and determined the influence of patient, fracture, and surgeon characteristics on choice of implant (intramedullary nailing (IMN) versus sliding hip screw (SHS)).

Methods

A total of 128 orthopaedic surgeons in the Science of Variation Group evaluated radiographs of 30 patients with Type A1 and A2 trochanteric hip fractures and indicated their preferred treatment: IMN or SHS. The management of Type A3 (reverse obliquity) trochanteric fractures was not evaluated. Agreement between surgeons was calculated using multirater kappa. Multivariate logistic regression models were used to assess whether patient, fracture, and surgeon characteristics were independently associated with choice of implant.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 152 - 159
1 Feb 2016
Corbacho B Duarte A Keding A Handoll H Chuang LH Torgerson D Brealey S Jefferson L Hewitt C Rangan A

Aims

A pragmatic multicentre randomised controlled trial (PROFHER) was conducted in United Kingdom National Health Service (NHS) hospitals to evaluate the clinical effectiveness and cost effectiveness of surgery compared with non-surgical treatment for displaced fractures of the proximal humerus involving the surgical neck in adults.

Methods

A cost utility analysis from the NHS perspective was performed. Differences between surgical and non-surgical treatment groups in costs and quality adjusted life years (QALYs) at two years were used to derive an estimate of the cost effectiveness of surgery using regression methods.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 956 - 962
1 Jul 2014
Ahearn N Oppy A Halliday R Rowett-Harris J Morris SA Chesser TJ Livingstone JA

Unstable bicondylar tibial plateau fractures are rare and there is little guidance in the literature as to the best form of treatment. We examined the short- to medium-term outcome of this injury in a consecutive series of patients presenting to two trauma centres. Between December 2005 and May 2010, a total of 55 fractures in 54 patients were treated by fixation, 34 with peri-articular locking plates and 21 with limited access direct internal fixation in combination with circular external fixation using a Taylor Spatial Frame (TSF). At a minimum of one year post-operatively, patient-reported outcome measures including the WOMAC index and SF-36 scores showed functional deficits, although there was no significant difference between the two forms of treatment. Despite low outcome scores, patients were generally satisfied with the outcome. We achieved good clinical and radiological outcomes, with low rates of complication. In total, only three patients (5%) had collapse of the joint of > 4 mm, and metaphysis to diaphysis angulation of greater than 5º, and five patients (9%) with displacement of > 4 mm. All patients in our study went on to achieve full union.

This study highlights the serious nature of this injury and generally poor patient-reported outcome measures following surgery, despite treatment by experienced surgeons using modern surgical techniques. Our findings suggest that treatment of complex bicondylar tibial plateau fractures with either a locking plate or a TSF gives similar clinical and radiological outcomes.

Cite this article: Bone Joint J 2014;96-B:956–62.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 548 - 554
1 Apr 2014
Sun H Luo CF Zhong B Shi HP Zhang CQ Zeng BF

Our aim was to compare polylevolactic acid screws with titanium screws when used for fixation of the distal tibiofibular syndesmosis at mid-term follow-up. A total of 168 patients, with a mean age of 38.5 years (18 to 72) who were randomly allocated to receive either polylevolactic acid (n = 86) or metallic (n = 82) screws were included. The Baird scoring system was used to assess the overall satisfaction and functional recovery post-operatively. The demographic details and characteristics of the injury were similar in the two groups. The mean follow-up was 55.8 months (48 to 66). The Baird scores were similar in the two groups at the final follow-up. Patients in the polylevolactic acid group had a greater mean dorsiflexion (p = 0.011) and plantar-flexion of the injured ankles (p < 0.001). In the same group, 18 patients had a mild and eight patients had a moderate foreign body reaction. In the metallic groups eight had mild and none had a moderate foreign body reaction (p <  0.001). In total, three patients in the polylevolactic acid group and none in the metallic group had heterotopic ossification (p = 0.246).

We conclude that both screws provide adequate fixation and functional recovery, but polylevolactic acid screws are associated with a higher incidence of foreign body reactions.

Cite this article: Bone Joint J 2014;96-B:548–54.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 230 - 238
1 Feb 2013
Giannoudis PV Kanakaris NK Delli Sante E Morell DJ Stengel D Prevezas N

Over a five-year period, adult patients with marginal impaction of acetabular fractures were identified from a registry of patients who underwent acetabular reconstruction in two tertiary referral centres. Fractures were classified according to the system of Judet and Letournel. A topographic classification to describe the extent of articular impaction was used, dividing the joint surface into superior, middle and inferior thirds. Demographic information, hospitalisation and surgery-related complications, functional (EuroQol 5-D) and radiological outcome according to Matta’s criteria were recorded and analysed. In all, 60 patients (57 men, three women) with a mean age of 41 years (18 to 72) were available at a mean follow-up of 48 months (24 to 206). The quality of the reduction was ‘anatomical’ in 44 hips (73.3%) and ‘imperfect’ in 16 (26.7%). The originally achieved anatomical reduction was lost in12 patients (25.8%). Radiologically, 33 hips (55%) were graded as ‘excellent’, 11 (18.3%) as ‘good’, one (1.7%) as ‘fair’ and 15 (25%) as ‘poor’. A total of 11 further operations were required in 11 cases, of which six were total hip replacements.

Univariate linear regression analysis of the functional outcome showed that factors associated with worse pain were increasing age and an inferior location of the impaction. Elevation of the articular impaction leads to joint preservation with satisfactory overall medium-term functional results, but secondary collapse is likely to occur in some patients.

Cite this article: Bone Joint J 2013;95-B:230–8.


Bone & Joint Research
Vol. 1, Issue 11 | Pages 289 - 296
1 Nov 2012
Savaridas T Wallace RJ Muir AY Salter DM Simpson AHRW

Objectives

Small animal models of fracture repair primarily investigate indirect fracture healing via external callus formation. We present the first described rat model of direct fracture healing.

Methods

A rat tibial osteotomy was created and fixed with compression plating similar to that used in patients. The procedure was evaluated in 15 cadaver rats and then in vivo in ten Sprague-Dawley rats. Controls had osteotomies stabilised with a uniaxial external fixator that used the same surgical approach and relied on the same number and diameter of screw holes in bone.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1669 - 1677
1 Dec 2010
Thakar C Alsousou J Hamilton TW Willett K

We evaluated the cost and consequences of proximal femoral fractures requiring further surgery because of complications. The data were collected prospectively in a standard manner from all patients with a proximal femoral fracture presenting to the trauma unit at the John Radcliffe Hospital over a five-year period. The total cost of treatment for each patient was calculated by separating it into its various components. The risk factors for the complications that arose, the location of their discharge and the mortality rates for these patients were compared to those of a matched control group. There were 2360 proximal femoral fractures in 2257 patients, of which 144 (6.1%) required further surgery. The mean cost of treatment in patients with complications was £18 709 (£2606.30 to £60.827.10), compared with £8610 (£918.54 to £45 601.30) for uncomplicated cases (p < 0.01), with a mean length of stay of 62.8 (44.5 to 79.3) and 32.7 (23.8 to 35.0) days, respectively. The probability of mortality after one month in these cases was significantly higher than in the control group, with a mean survival of 209 days, compared with 496 days for the controls. Patients with complications were statistically less likely to return to their own home (p < 0.01).

Greater awareness and understanding are required to minimise the complications of proximal femoral fractures and consequently their cost.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1053 - 1059
1 Aug 2006
Foss NB Kehlet H

Our aim was to determine the total blood loss associated with surgery for fracture of the hip and to identify risk factors for increased blood loss. We prospectively studied 546 patients with hip fracture. The total blood loss was calculated on the basis of the haemoglobin difference, the number of transfusions and the estimated blood volume. The hidden blood loss, in excess of that observed during surgery, varied from 547 ml (screws/ pins) to 1473 ml (intramedullary hip nail and screw) and was significantly associated with medical complications and increased hospital stay. The type of surgery, treatment with aspirin, intra-operative hypotension and gastro-intestinal bleeding or ulceration were all independent predictors of blood loss.

We conclude that total blood loss after surgery for hip fracture is much greater than that observed intra-operatively. Frequent post-operative measurements of haemoglobin are necessary to avoid anaemia.