Advertisement for orthosearch.org.uk
Results 1 - 20 of 3643
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1067 - 1070
1 Aug 2012
Melton JTK Mayahi R Baxter SE Facek M Glezos C

A consecutive series of patients with a hydroxyapatite-coated uncemented total knee replacement (TKR) performed by a single surgeon between 1992 and 1995 was analysed. All patients were invited for clinical review and radiological assessment. Revision for aseptic loosening was the primary outcome. Assessment was based on the Knee Society clinical score (KSS) and an independent radiological analysis. Of 471 TKRs performed in 356 patients, 432 TKRs in 325 patients were followed for a mean of 16.4 years (15 to 18). The 39 TKRs in 31 patients lost to follow-up had a mean KSS of 176 (148 to 198) at a mean of ten years. There were revisions in 26 TKRs (5.5%), of which 11 (2.3%) were for aseptic loosening. Other further surgery was carried out on 49 TKRs (10.4%) including patellar resurfacing in 20, arthrolysis in 19, manipulation under anaesthetic in nine and extensor mechanism reconstruction in one. Survivorship at up to 18 years without aseptic loosening was 96% (95% confidence interval 91.9 to 98.1), at which point the mean KSS was 176 (134 to 200). Of 110 knees that underwent radiological evaluation, osteolysis was observed in five (4.5%), one of which was revised. These data indicate that uncemented hydroxyapatite-coated TKR can achieve favourable long-term survivorship, at least as good as that of cemented designs


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 45 - 51
1 Jan 2013
Williams DP Blakey CM Hadfield SG Murray DW Price AJ Field RE

The Oxford knee score (OKS) is a validated and widely accepted disease-specific patient-reported outcome measure, but there is limited evidence regarding any long-term trends in the score. We reviewed 5600 individual OKS questionnaires (1547 patients) from a prospectively-collected knee replacement database, to determine the trends in OKS over a ten-year period following total knee replacement. The mean OKS pre-operatively was 19.5 (95% confidence interval (CI) 18.8 to 20.2). The maximum post-operative OKS was observed at two years (mean score 34.4 (95% CI 33.7 to 35.2)), following which a gradual but significant decline was observed through to the ten-year assessment (mean score 30.1 (95% CI 29.1 to 31.1)) (p < 0.001). A similar trend was observed for most of the individual OKS components (p < 0.001). Kneeling ability initially improved in the first year but was then followed by rapid deterioration (p < 0.001). Pain severity exhibited the greatest improvement, although residual pain was reported in over two-thirds of patients post-operatively, and peak improvement in the night pain component did not occur until year four. Post-operative OKS was lower for women (p < 0.001), those aged < 60 years (p < 0.003) and those with a body mass index > 35 kg/m. 2. (p < 0.014), although similar changes in scores were observed. This information may assist surgeons in advising patients of their expected outcomes, as well as providing a comparative benchmark for evaluating longer-term outcomes following knee replacement. Cite this article: Bone Joint J 2013;95-B:45–51


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 941 - 945
1 Jul 2012
Faour-Martín O Martín-Ferrero MA Almaraz-Gómez A Vega-Castrillo A

We present the electromyographic (EMG) results ten years after open decompression of the median nerve at the wrist and compare them with the clinical and functional outcomes as judged by Levine’s Questionnaire. This retrospective study evaluated 115 patients who had undergone carpal tunnel decompression at a mean of 10.47 years (9.24 to 11.36) previously. A positive EMG diagnosis was found in 77 patients (67%), including those who were asymptomatic at ten years. It is necessary to include both clinical and functional results as well as electromyographic testing in the long-term evaluation of patients who have undergone carpal tunnel decompression particularly in those in whom revision surgery is being considered. In doubtful cases or when there are differing outcomes, self-administered scales such as Levine’s Questionnaire should prevail over EMG results when deciding on the need for revision surgery


Bone & Joint Open
Vol. 2, Issue 5 | Pages 344 - 350
31 May 2021
Ahmad SS Hoos L Perka C Stöckle U Braun KF Konrads C

Aims. The follow-up interval of a study represents an important aspect that is frequently mentioned in the title of the manuscript. Authors arbitrarily define whether the follow-up of their study is short-, mid-, or long-term. There is no clear consensus in that regard and definitions show a large range of variation. It was therefore the aim of this study to systematically identify clinical research published in high-impact orthopaedic journals in the last five years and extract follow-up information to deduce corresponding evidence-based definitions of short-, mid-, and long-term follow-up. Methods. A systematic literature search was performed to identify papers published in the six highest ranked orthopaedic journals during the years 2015 to 2019. Follow-up intervals were analyzed. Each article was assigned to a corresponding subspecialty field: sports traumatology, knee arthroplasty and reconstruction, hip-preserving surgery, hip arthroplasty, shoulder and elbow arthroplasty, hand and wrist, foot and ankle, paediatric orthopaedics, orthopaedic trauma, spine, and tumour. Mean follow-up data were tabulated for the corresponding subspecialty fields. Comparison between means was conducted using analysis of variance. Results. Of 16,161 published articles, 590 met the inclusion criteria. Of these, 321 were of level IV evidence, 176 level III, 53 level II, and 40 level I. Considering all included articles, a long-term study published in the included high impact journals had a mean follow-up of 151.6 months, a mid-term study of 63.5 months, and a short-term study of 30.0 months. Conclusion. The results of this study provide evidence-based definitions for orthopaedic follow-up intervals that should provide a citable standard for the planning of clinical studies. A minimum mean follow-up of a short-term study should be 30 months (2.5 years), while a mid-term study should aim for a mean follow-up of 60 months (five years), and a long-term study should aim for a mean of 150 months (12.5 years). Level of Evidence: Level I. Cite this article: Bone Jt Open 2021;2(5):344–350


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 933 - 940
1 Jul 2020
Maempel JF Clement ND Wickramasinghe NR Duckworth AD Keating JF

Aims. The aim was to compare long-term patient-reported outcome measures (PROMs) after operative and nonoperative treatment of acute Achilles tendon rupture in the context of a randomized controlled trial. Methods. PROMs including the Short Musculoskeletal Function Assessment (SMFA), Achilles Tendon Total Rupture Score (ATRS), EuroQol five-dimension (EQ-5D), satisfaction, net promoter score and data regarding re-rupture, and venous thromboembolic rates were collected for patients randomized to receive either operative or nonoperative treatment for acute Achilles tendon rupture in a previous study. Of the 80 patients originally randomized, 64 (33 treated surgically, 31 nonoperatively) patients were followed up at a mean of 15.7 years (13.4 to 17.7). Results. There was no statistically significant difference between operatively and nonoperatively treated patients, in SMFA Dysfunction Index (median 1.56 (interquartile range (IQR) 0 to 5.51) vs 1.47 (IQR 0 to 5.15); p = 0.289), SMFA Bother Index (2.08 (IQR 0 to 12.50) vs 0.00 (IQR 0 to 6.25); p = 0.074), ATRS (94 (IQR 86 to 100) vs 95 (IQR 81 to 100); p = 0.313), EQ-5D-5L (1 (IQR 0.75 to 1) vs 1 (IQR 0.84 to 1); p = 0.137) or EQ-5D health today visual analogue score (85 (IQR 72.5 to 95) vs 85 (IQR 8 to 95); p = 0.367). There was no statistically significant difference between operative and nonoperative groups in terms of satisfaction (84% vs 100%; p = 0.119) or willingness to recommend treatment to friends or family (79% vs 87%; p = 0.255). Four nonoperative patients and two in the operative group sustained a re-rupture (p = 0.306). Conclusion. Both patient groups reported good results at long-term follow-up. The findings give no evidence of superior long-term patient reported outcomes (as measured by the SMFA) for surgical treatment over nonoperative treatment. There was no demonstrable difference in other patient reported outcome measures, satisfaction, or re-rupture rates at long-term follow-up. Cite this article: Bone Joint J 2020;102-B(7):933–940


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 112 - 117
1 May 2024
Hickie KL Neufeld ME Howard LC Greidanus NV Masri BA Garbuz DS

Aims. There are limited long-term studies reporting on outcomes of the Zimmer Modular Revision (ZMR) stem, and concerns remain regarding failure. Our primary aim was to determine long-term survival free from all-cause revision and stem-related failure for this modular revision stem in revision total hip arthroplasty (THA). Secondary aims included evaluating radiological and functional outcomes. Methods. We retrospectively identified all patients in our institutional database who underwent revision THA using the ZMR system from January 2000 to December 2007. We included 106 patients (108 hips) with a mean follow-up of 14.5 years (2.3 to 22.3). Mean patient age was 69.2 years (37.0 to 89.4), and 51.9% were female (n = 55). Indications for index revision included aseptic loosening (73.1%), infection (16.7%), fracture (9.3%), and stem fracture (0.9%). Kaplan-Meier analysis was used to determine the all-cause and stem-related failure revision-free survival. At most recent follow-up, Oxford Hip Scores (OHS) were collected, and radiological stem stability was determined using the Engh classification. Results. A total of 17 hips (15.7%) underwent re-revision of any component. Indications for re-revision were stem failure (35.3%; n = 6), infection (29.4%; n = 5), instability (29.4%; n = 5), and acetabular aseptic loosening (5.9%; n = 1). The five- and 15-year all-cause survival was 89.7% (95% confidence interval (CI) 86.7 to 92.7) and 83.3% (95% CI 79.6 to 87.0), respectively. There were six re-revisions (5.6%) for stem failure; five for stem fracture and one for aseptic loosening. The five- and 15-year survival free from stem-related failure was 97.2% (95% CI 95.6 to 98.8) and 94.0% (95% CI 91.6 to 96.4), respectively. At final follow-up, the mean OHS was 36.9 (8.0 to 48.0) and 95.7% (n = 66) of surviving modular revision stems were well-fixed in available radiographs. Conclusion. Femoral revision with the ZMR offers satisfactory long-term all-cause revision-free survival, good survival free of stem-related failure, and favourable clinical outcomes. Stem fracture was the most common reason for stem-related failure and occurred both early and late. This highlights the importance of both early and long-term surveillance for stem-related failure. Cite this article: Bone Joint J 2024;106-B(5 Supple B):112–117


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 957 - 963
1 Sep 2024
Baek CH Kim JG Kim BT

Aims. Favourable short-term outcomes have been reported following latissimus dorsi tendon transfer for patients with an irreparable subscapularis (SSC) tendon tear. The aim of this study was to investigate the long-term outcomes of this transfer in these patients. Methods. This was a retrospective study involving 30 patients with an irreparable SSC tear and those with a SSC tear combined with a reparable supraspinatus tear, who underwent a latissimus dorsi tendon transfer. Clinical scores and active range of motion (aROM), SSC-specific physical examination and the rate of return to work were assessed. Radiological assessment included recording the acromiohumeral distance (AHD), the Hamada grade of cuff tear arthropathy and the integrity of the transferred tendon. Statistical analysis compared preoperative, short-term (two years), and final follow-up at a mean of 8.7 years (7 to 10). Results. There were significant improvements in clinical scores, in the range and strength of internal rotation and aROM compared with the preoperative values in the 26 patients (87%) who were available for long-term follow-up. These improvements were maintained between short- and long-term follow-ups. Although there was a decreased mean AHD of 7.3 mm (SD 1.5) and an increased mean Hamada grade of 1.7 (SD 0.5) at final follow-up, the rate of progression of cuff tear arthropathy remained low-grade. Comparison between the isolated SSC and combined SSC and reparable supraspinatus tear groups showed no significant differences. At final follow-up, one patient (3.8%) had undergone revision surgery to a reverse shoulder arthroplasty (RSA). No neurological complications were associated with the procedure. Conclusion. Latissimus dorsi transfer for an irreparable SSC tendon tear resulted in a significant clinical improvement, particularly in pain, range and strength of internal rotation and aROM, which were maintained over a mean of 8.7 years following surgery. Given that this was a long-term outcome study, there was a low-grade progression in the rate of cuff tear arthropathy. Thus, the long-term clinical efficacy of latissimus dorsi tendon transfer in patients with irreparable SSC was confirmed as a joint-preserving procedure for these patients, suggesting it as an effective alternative to RSA in young, active patients without degenerative changes of the glenohumeral joint. Cite this article: Bone Joint J 2024;106-B(9):957–963


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 455 - 464
15 Mar 2023
de Joode SGCJ Meijer R Samijo S Heymans MJLF Chen N van Rhijn LW Schotanus MGM

Aims. Multiple secondary surgical procedures of the shoulder, such as soft-tissue releases, tendon transfers, and osteotomies, are described in brachial plexus birth palsy (BPBP) patients. The long-term functional outcomes of these procedures described in the literature are inconclusive. We aimed to analyze the literature looking for a consensus on treatment options. Methods. A systematic literature search in healthcare databases (PubMed, Embase, the Cochrane library, CINAHL, and Web of Science) was performed from January 2000 to July 2020, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. The quality of the included studies was assessed with the Cochrane ROBINS-I risk of bias tool. Relevant trials studying BPBP with at least five years of follow-up and describing functional outcome were included. Results. Of 5,941 studies, 19 were included after full-text screening. A total of 15 surgical techniques were described. All studies described an improvement in active external rotation (range 12° to 128°). A decrease in range of motion and Mallet score after long-term (five to 30 years) follow-up compared to short-term follow-up was seen in most studies. Conclusion. The literature reveals that functional outcome increases after different secondary procedures, even in the long term. Due to the poor methodological quality of the included studies and the variations in indication for surgery and surgical techniques described, a consensus on the long-term functional outcome after secondary surgical procedures in BPBP patients cannot be made. Cite this article: Bone Joint J 2023;105-B(4):455–464


Bone & Joint Open
Vol. 4, Issue 12 | Pages 964 - 969
19 Dec 2023
Berwin JT Duffy SDX Gargan MF Barnes JR

Aims. We assessed the long-term outcomes of a large cohort of patients who have undergone a periacetabular osteotomy (PAO), and sought to validate a patient satisfaction questionnaire for use in a PAO cohort. Methods. All patients who had undergone a PAO from July 1998 to February 2013 were surveyed, with several patient-reported outcome measures (PROMs) and radiological measurements of preoperative acetabular dysplasia and postoperative correction also recorded. Patients were asked to rate their level of satisfaction with their operation in achieving pain relief, restoration of activities of daily living, ability to perform recreational activity, and their overall level of satisfaction with the procedure. Results. A total of 143 PAOs were performed between 1998 and 2013. Of those, 90 postoperative surveys were returned. Only 65 patients (73 hips) had both pre- and postoperative radiographs available for measurement. The mean time to follow-up was 15 years (6.5 to 20). Most patients were female (91%), with a mean age of 26.4 years (14.9 to 48.3) at the time of their surgery. A statistically significant improvement in radiological correction was detected in all hips (p < 0.001). A total of 67 patients (92.3%) remained either very satisfied or satisfied with their PAO. The internal consistency of the patient satisfaction questionnaire, measured using Cronbach’s α, ranged from 0.89 to 0.94 indicating ‘good’ to ‘excellent’ reliability. Conclusion. Outcomes of importance to patients undergoing a PAO include several key domains: pain relief, improve activities of daily living, and improve recreational ability. Our study demonstrates high rates of long-term patient satisfaction in all domains, and found the patient satisfaction questionnaire to be a valid and reliable instrument for use in this cohort. Cite this article: Bone Jt Open 2023;4(12):964–969


Bone & Joint Open
Vol. 4, Issue 10 | Pages 776 - 781
16 Oct 2023
Matar HE Bloch BV James PJ

Aims. The aim of this study was to evaluate medium- to long-term outcomes and complications of the Stanmore Modular Individualised Lower Extremity System (SMILES) rotating hinge implant in revision total knee arthroplasty (rTKA) at a tertiary unit. It is hypothesized that this fully cemented construct leads to satisfactory clinical outcomes. Methods. A retrospective consecutive study of all patients who underwent a rTKA using the fully cemented SMILES rotating hinge prosthesis between 2005 to 2018. Outcome measures included aseptic loosening, reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both prospectively collected local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years. Results. Overall, 69 consecutive patients (69 knees) were included with a median age of 78 years (interquartile range 69 to 84), and there were 46 females (66.7%). Indications were septic revisions in 26 (37.7%), and aseptic aetiology in the remining 43 (62.3%). The mean follow-up was 9.7 years (4 to 18), and the overall complication was rate was 7.24%, all with patellofemoral complications. Failure rate with ‘any cause revision’ was 5.8%. There was one case of aseptic loosening of the femoral component. At ten years, 17/69 patients (24.63%) had died, and implant survivorship was 92.2%. Conclusion. In our experience, the SMILES rotating hinge prosthesis achieves satisfactory long-term outcomes with ten-year implant survivorship of 92.2% and a patellofemoral complication rate of 7.24%. Cite this article: Bone Jt Open 2023;4(10):776–781


Aims. The aim of this study was to investigate the distribution of phenotypes in Asian patients with end-stage osteoarthritis (OA) and assess whether the phenotype affected the clinical outcome and survival of mechanically aligned total knee arthroplasty (TKA). We also compared the survival of the group in which the phenotype unintentionally remained unchanged with those in which it was corrected to neutral. Methods. The study involved 945 TKAs, which were performed in 641 patients with primary OA, between January 2000 and January 2009. These were classified into 12 phenotypes based on the combined assessment of four categories of the arithmetic hip-knee-ankle angle and three categories of actual joint line obliquity. The rates of survival were analyzed using Kaplan-Meier methods and the log-rank test. The Hospital for Special Surgery score and survival of each phenotype were compared with those of the reference phenotype with neutral alignment and a parallel joint line. We also compared long-term survival between the unchanged phenotype group and the corrected to neutral alignment-parallel joint line group in patients with Type IV-b (mild to moderate varus alignment-parallel joint line) phenotype. Results. The most common phenotype was Type I-b (mild to moderate varus alignment-medial joint line; 27.1% (n = 256)), followed by Type IV-b (23.2%; n = 219). There was no significant difference in the clinical outcomes and long-term survival between the groups. In Type IV-b phenotypes, the neutrally corrected group showed higher 15-year survival compared with the unchanged-phenotype group (94.9% (95% confidence interval (CI) 92.0 to 97.8) vs 74.2% (95% CI 98.0 to 100); p = 0.020). Conclusion. Constitutional varus was confirmed in more than half of these patients. Mechanically aligned TKA can achieve consistent clinical outcomes and long-term survival, regardless of the patient’s phenotype. The neutrally corrected group had better long-term survival compared with the unchanged phenotype group. Cite this article: Bone Joint J 2024;106-B(5):460–467


Bone & Joint Open
Vol. 5, Issue 10 | Pages 868 - 878
14 Oct 2024
Sekita T Asano N Kobayashi H Yonemoto T Kobayashi E Ishii T Kawai A Nakayama R

Aims. Surgical limb sparing for knee-bearing paediatric bone sarcoma is considered to have a clinically significant influence on postoperative function due to complications and leg-length discrepancies. However, researchers have not fully evaluated the long-term postoperative functional outcomes. Therefore, in this study, we aimed to elucidate the risk factors and long-term functional prognosis associated with paediatric limb-sparing surgery. Methods. We reviewed 40 patients aged under 14 years who underwent limb-sparing surgery for knee bone sarcoma (15 cases in the proximal tibia and 25 in the distal femur) between January 2000 and December 2013, and were followed up for a minimum of five years. A total of 35 patients underwent reconstruction using artificial materials, and five underwent biological reconstruction. We evaluated the patients’ postoperative complications, survival rate of reconstruction material, and limb, limb function, and leg-length discrepancy at the final follow-up, as well as the risk factors for each. Results. Complications were observed in 55% (22/40) of patients. The limb survival and reconstruction material rates at five and ten years were 95% and 91%, and 88% and 66%, respectively. Infection was the only risk factor in both survivals (p < 0.001, p = 0.019). In the 35 patients with limb preservation, the median International Society of Limb Salvage (ISOLS) score at the final follow-up was 80 (47% to 97%). Younger age (p = 0.027) and complications (p = 0.005) were poor prognostic factors. A negative correlation was found between age and leg-length discrepancy (R = −0.426; p = 0.011). The ISOLS scores were significantly lower in patients with a leg-length discrepancy of more than 5 cm (p = 0.005). Conclusion. Young age and complications were linked to an unfavourable functional prognosis. Leg-length correction was insufficient, especially in very young children, resulting in decreased function of the affected limb. Limb-sparing surgery for these children remains a considerable challenge. Cite this article: Bone Jt Open 2024;5(10):868–878


Bone & Joint Open
Vol. 5, Issue 9 | Pages 785 - 792
19 Sep 2024
Clement RGE Wong SJ Hall A Howie SEM Simpson AHRW

Aims. The aims of this study were to: 1) report on a cohort of skeletally mature patients with native hip and knee septic arthritis over a 14-year period; 2) to determine the rate of joint failure in patients who had experienced an episode of hip or knee septic arthritis; and 3) to assess the outcome following septic arthritis relative to the infecting organism, whether those patients infected by Staphylococcus aureus would be more likely to have adverse outcomes than those infected by other organisms. Methods. All microbiological samples from joint aspirations between March 2000 and December 2014 at our institution were reviewed in order to identify cases of culture-proven septic arthritis. Cases in children (aged < 16 years) and prosthetic joints were excluded. Data were abstracted on age at diagnosis, sex, joint affected (hip or knee), type of organisms isolated, cause of septic arthritis, comorbidities within the Charlson Comorbidity Index (CCI), details of treatment, and outcome. Results. A total of 142 patients were confirmed to have had an episode of septic arthritis in a native hip (n = 17) or knee joint (n = 125). S. aureus accounted for 57.7% of all hip and knee joint infections. There were 13 inpatient deaths attributed to septic arthritis. The median age of the patients who died was 77.5 (46.9 to 92.2) and their median age-adjusted CCI was 8 (6 to 12). A failure of the joint occurred in 26 knees (21%) and nine hips (53%). Of the knee joints infected by S. aureus (n = 71), 23 knees (32%) went into failure of joint, whereas of those infected by other organisms (n = 54), only three knees (6%) failed. Conclusion. Based on our study findings, hip and knee septic arthritis long-term outcomes were substantially worse than their immediate outcome suggested. Failure of knee joint is 6.1 times more likely to occur in those infected with S. aureus. Cite this article: Bone Jt Open 2024;5(9):785–792


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 110 - 114
1 Mar 2024
Yee AHF Chan VWK Fu H Chan P Chiu KY

Aims. The aim of this study was to evaluate the survival of a collarless, straight, hydroxyapatite-coated femoral stem in total hip arthroplasty (THA) at a minimum follow-up of 20 years. Methods. We reviewed the results of 165 THAs using the Omnifit HA system in 138 patients, performed between August 1993 and December 1999. The mean age of the patients at the time of surgery was 46 years (20 to 77). Avascular necrosis was the most common indication for THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (20 to 31). At 20 and 25 years, 113 THAs in 91 patients and 63 THAs in 55 patients were available for review, respectively, while others died or were lost to follow-up. Kaplan-Meier analysis was performed to evaluate the survival of the stem. Radiographs were reviewed regularly, and the stability of the stem was evaluated using the Engh classification. Results. A total of seven stems (4.2%) were revised during the study period: one for aseptic loosening, three for periprosthetic fracture, two for infection, and one for recurrent dislocation. At 20 years, survival with revision of the stem for any indication and for aseptic loosening as the endpoint was 96.0% (95% confidence interval (CI) 92.6 to 99.5) and 98.4% (95% CI 96.2 to 100), respectively. At 25 years, the corresponding rates of survival were 94.5% (95% CI 89.9 to 99.3) and 98.1% (95% CI 95.7 to 99.6), respectively. There was radiological evidence of stable bony fixation in 86 stems (76.1%) and evidence of loosening in four (3.5%) at 20 years. All patients with radiological evidence of loosening were asymptomatic. Conclusion. The Omnifit HA femoral stem offered promising long-term survival into the third decade. Cite this article: Bone Joint J 2024;106-B(3 Supple A):110–114


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 38 - 43
1 Mar 2024
Buckner BC Urban ND Cahoy KM Lyden ER Deans CF Garvin KL

Aims. Oxidized zirconium (OxZi) and highly cross-linked polyethylene (HXLPE) were developed to minimize wear and risk of osteolysis in total hip arthroplasty (THA). However, retrieval studies have shown that scratched femoral heads may lead to runaway wear, and few reports of long-term results have been published. The purpose of this investigation is to report minimum ten-year wear rates and clinical outcomes of THA with OxZi femoral heads on HXLPE, and to compare them with a retrospective control group of cobalt chrome (CoCr) or ceramic heads on HXLPE. Methods. From 2003 to 2006, 108 THAs were performed on 96 patients using an OxZi head with a HXLPE liner with minimum ten-year follow-up. Harris Hip Scores (HHS) were collected preoperatively and at the most recent follow-up (mean 13.3 years). Linear and volumetric liner wear was measured on radiographs of 85 hips with a minimum ten-year follow-up (mean 14.5 years). This was compared to a retrospective control group of 45 THAs using ceramic or CoCr heads from October 1999 to February 2005, with a minimum of ten years’ follow-up. Results. Average HHS improved from 50.8 to 91.9 and 51.0 to 89.8 in the OxZi group and control group, respectively (p = 0.644), with no osteolysis in either group. Linear and volumetric wear rates in the OxZi group averaged 0.03 mm/year and 3.46 mm. 3. /year, respectively. There was no statistically significant difference in HHS scores, nor in linear or volumetric wear rate between the groups, and no revision for any indication. Conclusion. The radiological and clinical outcomes, and survivorship of THA with OxZi femoral heads and HXLPE liners, were excellent, and comparable to CoCr or ceramic heads at minimum ten-year follow-up. Wear rates are below what would be expected for development of osteolysis. OxZi-HXLPE is a durable bearing couple with excellent long-term outcomes. Cite this article: Bone Joint J 2024;106-B(3 Supple A):38–43


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 864 - 871
1 Aug 2023
Tyas B Marsh M de Steiger R Lorimer M Petheram TG Inman DS Reed MR Jameson SS

Aims. Several different designs of hemiarthroplasty are used to treat intracapsular fractures of the proximal femur, with large variations in costs. No clinical benefit of modular over monoblock designs has been reported in the literature. Long-term data are lacking. The aim of this study was to report the ten-year implant survival of commonly used designs of hemiarthroplasty. Methods. Patients recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) between 1 September 1999 and 31 December 2020 who underwent hemiarthroplasty for the treatment of a hip fracture with the following implants were included: a cemented monoblock Exeter Trauma Stem (ETS), cemented Exeter V40 with a bipolar head, a monoblock Thompsons prosthesis (Cobalt/Chromium or Titanium), and an Exeter V40 with a Unitrax head. Overall and age-defined cumulative revision rates were compared over the ten years following surgery. Results. A total of 41,949 hemiarthroplasties were included. Exeter V40 with a Unitrax head was the most commonly used (n = 20,707, 49.4%). The overall rate of revision was small. A total of 28,201 patients (67.2%) were aged > 80 years. There were no significant differences in revision rates across all designs of hemiarthroplasty in patients of this age at any time. The revision rates for all designs were < 3.5%, three years postoperatively. At subsequent times the ETS and Exeter V40 with a bipolar head performed well in all age groups. The unadjusted ten-year mortality rate for the whole cohort was 82.2%. Conclusion. There was no difference in implant survival between all the designs of hemiarthroplasty in the first three years following surgery, supporting the selection of a cost-effective design of hemiarthroplasty for most patients with an intracapsular fracture of the hip, as determined by local availability and costs. Beyond this, the ETS and Exeter bipolar designs performed well in all age groups. Cite this article: Bone Joint J 2023;105-B(8):864–871


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 668 - 678
1 Jun 2023
Friedman RJ Boettcher ML Grey S Flurin P Wright TW Zuckerman JD Eichinger JK Roche C

Aims. The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system. Methods. We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217). Results. Relative to their preoperative condition, each glenoid cohort had significant improvements in clinical outcomes from two years to ten years after surgery. Patients with cage glenoids had significantly better clinical outcomes, with higher patient-reported outcome scores and significantly increased active range of motion, compared with those with keel and peg glenoids. Those with cage glenoids also had significantly fewer complications (keel: 13.3%, peg: 13.1%, cage: 7.4%), revisions (keel: 7.1%, peg 9.7%, cage 3.5%), and aseptic glenoid loosening and failure (keel: 4.7%, peg: 5.8%, cage: 2.5%). Regarding radiological outcomes, 70 patients (11.2%) with cage glenoids had glenoid radiolucent lines (RLLs). The cage glenoid RLL rate was 3.3-times (p < 0.001) less than those with keel glenoids (37.3%) and 4.6-times (p < 0.001) less than those with peg glenoids (51.2%). Conclusion. These findings show that good long-term clinical and radiological outcomes can be achieved with each of the three aTSA designs of glenoid component analyzed in this study. However, there were some differences in clinical and radiological outcomes: generally, cage glenoids performed best, followed by cemented keel glenoids, and finally cemented peg glenoids. Cite this article: Bone Joint J 2023;105-B(6):668–678


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1464 - 1471
1 Sep 2021
Barker TP Steele N Swamy G Cook A Rai A Crawford R Lutchman L

Aims. Cauda equina syndrome (CES) can be associated with chronic severe lower back pain and long-term autonomic dysfunction. This study assesses the recently defined core outcome set for CES in a cohort of patients using validated questionnaires. Methods. Between January 2005 and December 2019, 82 patients underwent surgical decompression for acute CES secondary to massive lumbar disc prolapse at our hospital. After review of their records, patients were included if they presented with the clinical and radiological features of CES, then classified as CES incomplete (CESI) or with painless urinary retention (CESR) in accordance with guidelines published by the British Association of Spinal Surgeons. Patients provided written consent and completed a series of questionnaires. Results. In total, 61 of 82 patients returned a completed survey. Their mean age at presentation was 43 years (20 to 77; SD 12.7), and the mean duration of follow-up 58.2 months (11 to 182; SD 45.3). Autonomic dysfunction was frequent: 33% of patients reported bladder dysfunction, and 10% required a urinary catheter. There was a 38% and 53% incidence of bowel and sexual dysfunction, respectively: 47% of patients reported genital numbness. A total of 67% reported significant back pain: 44% required further investigation and 10% further intervention for the management of lower back pain. Quality of life was lower than expected when corrected for age and sex. Half the patients reported moderate or worse depression, and 40% of patients of working age could no longer work due to problems attributable to CES. Urinary and faecal incontinence, catheter use, sexual dysfunction, and genital numbness were significantly more common in patients with CESR. Conclusion. This study reports the long-term outcome of patients with CES and is the first to use validated patient-reported outcome measures to assess the CES Core Outcome Set. Persistent severe back pain and on-going autonomic dysfunction were frequently reported at a mean follow-up of five years. Cite this article: Bone Joint J 2021;103-B(9):1464–1471


Bone & Joint Open
Vol. 3, Issue 5 | Pages 375 - 382
5 May 2022
Teunissen JS van der Oest MJW Selles RW Ulrich DJO Hovius SER van der Heijden B

Aims. The primary aim of this study was to describe long-term patient-reported outcomes after ulna shortening osteotomy for ulna impaction syndrome. Methods. Overall, 89 patients treated between July 2011 and November 2017 who had previously taken part in a routine outcome evaluation up to 12 months postoperatively were sent an additional questionnaire in February 2021. The primary outcome was the Patient-Rated Wrist and Hand Evaluation (PRWHE) total score. Secondary outcomes included patient satisfaction with treatment results, complications, and subsequent treatment for ulnar-sided wrist pain. Linear mixed models were used to compare preoperative, 12 months, and late follow-up (ranging from four to nine years) PRWHE scores. Results. Long-term outcomes were available in 66 patients (74%) after a mean follow-up of six years (SD 1). The mean PRWHE total score improved from 63 before surgery to 19 at late follow-up (difference in means (Δ) 44; 95% confidence interval (CI) 39 to 50; p = <0.001). Between 12 months and late follow-up, the PRWHE total score also improved (Δ 12; 95% CI 6 to 18; p = < 0.001). At late follow-up, 14/66 of patients (21%) reported a PRWHE total score of zero, whereas this was 3/51 patients (6%) at 12 months (p = 0.039). In all, 58/66 patients (88%) would undergo the same treatment again under similar circumstances. Subsequent treatment (total n = 66; surgical n = 57) for complications or recurrent symptoms were performed in 50/66 patients (76%). The most prevalent type of reoperation was hardware removal in 42/66 (64%), and nonunion occurred in 8/66 (12%). Conclusion. Ulna shortening osteotomy improves patient-reported pain and function that seems to sustain at late follow-up. While satisfaction levels are generally high, reoperations such as hardware removal are common. Cite this article: Bone Jt Open 2022;3(5):375–382


Bone & Joint Open
Vol. 2, Issue 11 | Pages 981 - 987
25 Nov 2021
Feitz R Khoshnaw S van der Oest MJW Souer JS Slijper HP Hovius SER Selles RW

Aims. Studies on long-term patient-reported outcomes after open surgery for triangular fibrocartilage complex (TFCC) are scarce. Surgeons and patients would benefit from self-reported outcome data on pain, function, complications, and satisfaction after this surgery to enhance shared decision-making. The aim of this study is to determine the long-term outcome of adults who had open surgery for the TFCC. Methods. A prospective cohort study that included patients with open surgery for the TFCC between December 2011 and September 2015. In September 2020, we sent these patients an additional follow-up questionnaire, including the Patient-Rated Wrist Evaluation (PRWE), to score satisfaction, complications, pain, and function. Results. A total of 113 patients were included in the analysis. At ≥ 60 months after an open TFCC reinsertion, we found a mean PRWE total score of 19 (SD 21), a mean PRWE pain score of 11 (SD 11), and a PRWE function score of 9 (SD 10). The percentage of patients obtaining minimum clinically important difference rose from 77% at 12 months to 83% at more than 60 months (p < 0.001). Patients reported fewer complications than surgeons, and overall complication rate was low. Conclusion. Outcomes of patient-reported pain, function scores, and satisfaction are improved five years after open surgery for the TFCC. Cite this article: Bone Jt Open 2021;2(11):981–987