We examined the one-year risk of symptomatic
venous thromboembolism (VTE) following primary total hip replacement
(THR) among Danish patients and a comparison cohort from the general
population. From the Danish Hip Arthroplasty Registry we identified
all primary THRs performed in Denmark between 1995 and 2010 (n =
85 965). In all, 97% of patients undergoing THR received low-molecular-weight
heparin products during hospitalisation. Through the Danish Civil
Registration System we sampled a comparison cohort who had not undergone
THR from the general population (n = 257 895). Among the patients
undergoing THR, the risk of symptomatic VTE was 0.79% between 0
and 90 days after surgery and 0.29% between 91 and 365 days after
surgery. In the comparison cohort the corresponding risks were 0.05%
and 0.12%, respectively. The adjusted relative risks of symptomatic
VTE among patients undergoing THR were 15.84 (95% confidence interval
(CI) 13.12 to 19.12) during the first 90 days after surgery and
2.41 (95% CI 2.04 to 2.85) during 91 to 365 days after surgery,
compared with the comparison cohort. The relative risk of VTE was
elevated irrespective of the gender, age and level of comorbidity
at the time of THR. We concluded that THR was associated with an increased risk of
symptomatic VTE up to one year after surgery compared with the general
population, although the absolute risk is small.
We performed a randomised, radiostereometric study comparing two different bone cements, one of which has been sparsely clinically documented. Randomisation of 60 total hip replacements (57 patients) into two groups of 30 was undertaken. All the patients were operated on using a cemented Charnley total hip replacement, the only difference between groups being the bone cement used to secure the femoral component. The two cements used were Palamed G and Palacos R with gentamicin. The patients were followed up with repeated clinical and radiostereometric examinations for two years to assess the micromovement of the femoral component and the clinical outcome. The mean subsidence was 0.18 mm and 0.21 mm, and the mean internal rotation was 1.7° and 2.0° at two years for the Palamed G and Palacos R with gentamicin bone cements, respectively. We found no statistically significant differences between the groups. Micromovement occurred between the femoral component and the cement, while the cement mantle was stable inside the bone. The Harris hip score improved from a mean of 38 points (14 to 54) and 36 (10 to 57) pre-operatively to a mean of 92 (77 to 100) and 91 (63 to 100) at two years in the Palamed G and Palacos R groups, respectively. No differences were found between the groups. Both bone cements provided good initial fixation of the femoral component and good clinical results at two years.