Advertisement for orthosearch.org.uk
Results 1 - 20 of 44
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 53 - 61
1 Jan 2024
Buckland AJ Huynh NV Menezes CM Cheng I Kwon B Protopsaltis T Braly BA Thomas JA

Aims

The aim of this study was to reassess the rate of neurological, psoas-related, and abdominal complications associated with L4-L5 lateral lumbar interbody fusion (LLIF) undertaken using a standardized preoperative assessment and surgical technique.

Methods

This was a multicentre retrospective study involving consecutively enrolled patients who underwent L4-L5 LLIF by seven surgeons at seven institutions in three countries over a five-year period. The demographic details of the patients and the details of the surgery, reoperations and complications, including femoral and non-femoral neuropraxia, thigh pain, weakness of hip flexion, and abdominal complications, were analyzed. Neurological and psoas-related complications attributed to LLIF or posterior instrumentation and persistent symptoms were recorded at one year postoperatively.


Bone & Joint Research
Vol. 12, Issue 4 | Pages 245 - 255
3 Apr 2023
Ryu S So J Ha Y Kuh S Chin D Kim K Cho Y Kim K

Aims

To determine the major risk factors for unplanned reoperations (UROs) following corrective surgery for adult spinal deformity (ASD) and their interactions, using machine learning-based prediction algorithms and game theory.

Methods

Patients who underwent surgery for ASD, with a minimum of two-year follow-up, were retrospectively reviewed. In total, 210 patients were included and randomly allocated into training (70% of the sample size) and test (the remaining 30%) sets to develop the machine learning algorithm. Risk factors were included in the analysis, along with clinical characteristics and parameters acquired through diagnostic radiology.


Aims

The optimal procedure for the treatment of ossification of the posterior longitudinal ligament (OPLL) remains controversial. The aim of this study was to compare the outcome of anterior cervical ossified posterior longitudinal ligament en bloc resection (ACOE) with posterior laminectomy and fusion with bone graft and internal fixation (PTLF) for the surgical management of patients with this condition.

Methods

Between July 2017 and July 2019, 40 patients with cervical OPLL were equally randomized to undergo surgery with an ACOE or a PTLF. The clinical and radiological results were compared between the two groups.


Bone & Joint Research
Vol. 10, Issue 12 | Pages 797 - 806
8 Dec 2021
Chevalier Y Matsuura M Krüger S Traxler H Fleege† C Rauschmann M Schilling C

Aims. Anchorage of pedicle screw rod instrumentation in the elderly spine with poor bone quality remains challenging. Our study aims to evaluate how the screw bone anchorage is affected by screw design, bone quality, loading conditions, and cementing techniques. Methods. Micro-finite element (µFE) models were created from micro-CT (μCT) scans of vertebrae implanted with two types of pedicle screws (L: Ennovate and R: S. 4. ). Simulations were conducted for a 10 mm radius region of interest (ROI) around each screw and for a full vertebra (FV) where different cementing scenarios were simulated around the screw tips. Stiffness was calculated in pull-out and anterior bending loads. Results. Experimental pull-out strengths were excellently correlated to the µFE pull-out stiffness of the ROI (R. 2. > 0.87) and FV (R. 2. > 0.84) models. No significant difference due to screw design was observed. Cement augmentation increased pull-out stiffness by up to 94% and 48% for L and R screws, respectively, but only increased bending stiffness by up to 6.9% and 1.5%, respectively. Cementing involving only one screw tip resulted in lower stiffness increases in all tested screw designs and loading cases. The stiffening effect of cement augmentation on pull-out and bending stiffness was strongly and negatively correlated to local bone density around the screw (correlation coefficient (R) = -0.95). Conclusion. This combined experimental, µCT and µFE study showed that regional analyses may be sufficient to predict fixation strength in pull-out and that full analyses could show that cement augmentation around pedicle screws increased fixation stiffness in both pull-out and bending, especially for low-density bone. Cite this article: Bone Joint Res 2021;10(12):797–806


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 536 - 541
1 Mar 2021
Ferlic PW Hauser L Götzen M Lindtner RA Fischler S Krismer M

Aims

The aim of this retrospective study was to compare the correction achieved using a convex pedicle screw technique and a low implant density achieved using periapical concave-sided screws and a high implant density. We hypothesized that there would be no difference in outcome between the two techniques.

Methods

We retrospectively analyzed a series of 51 patients with a thoracic adolescent idiopathic scoliosis. There were 26 patients in the convex pedicle screw group who had screws implanted periapically (Group 2) and a control group of 25 patients with bilateral pedicle screws (Group 1). The patients’ charts were reviewed and pre- and postoperative radiographs evaluated. Postoperative patient-reported outcome measures (PROMs) were recorded.


Bone & Joint Research
Vol. 9, Issue 10 | Pages 653 - 666
7 Oct 2020
Li W Li G Chen W Cong L

Aims

The aim of this study was to systematically compare the safety and accuracy of robot-assisted (RA) technique with conventional freehand with/without fluoroscopy-assisted (CT) pedicle screw insertion for spine disease.

Methods

A systematic search was performed on PubMed, EMBASE, the Cochrane Library, MEDLINE, China National Knowledge Infrastructure (CNKI), and WANFANG for randomized controlled trials (RCTs) that investigated the safety and accuracy of RA compared with conventional freehand with/without fluoroscopy-assisted pedicle screw insertion for spine disease from 2012 to 2019. This meta-analysis used Mantel-Haenszel or inverse variance method with mixed-effects model for heterogeneity, calculating the odds ratio (OR), mean difference (MD), standardized mean difference (SMD), and 95% confidence intervals (CIs). The results of heterogeneity, subgroup analysis, and risk of bias were analyzed.


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1368 - 1374
3 Oct 2020
McDonnell JM Ahern DP Lui DF Yu H Lehovsky J Noordeen H Molloy S Butler JS Gibson A

Aims

Whether a combined anteroposterior fusion or a posterior-only fusion is more effective in the management of patients with Scheuermann’s kyphosis remains controversial. The aim of this study was to compare the radiological and clinical outcomes of these surgical approaches, and to evaluate the postoperative complications with the hypothesis that proximal junctional kyphosis would be more common in one-stage posterior-only fusion.

Methods

A retrospective review of patients treated surgically for Scheuermann’s kyphosis between 2006 and 2014 was performed. A total of 62 patients were identified, with 31 in each group. Parameters were compared to evaluate postoperative outcomes using chi-squared tests, independent-samples t-tests, and z-tests of proportions analyses where applicable.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 506 - 512
1 Apr 2020
de Bodman C Ansorge A Tabard A Amirghasemi N Dayer R

Aims

The direct posterior approach with subperiosteal dissection of the paraspinal muscles from the vertebrae is considered to be the standard approach for the surgical treatment of adolescent idiopathic scoliosis (AIS). We investigated whether or not a minimally-invasive surgery (MIS) technique could offer improved results.

Methods

Consecutive AIS patients treated with an MIS technique at two tertiary centres from June 2013 to March 2016 were retrospectively included. Preoperative patient deformity characteristics, perioperative parameters, power of deformity correction, and complications were studied. A total of 93 patients were included. The outcome of the first 25 patients and the latter 68 were compared as part of our safety analysis to examine the effect of the learning curve.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 371 - 375
1 Mar 2020
Cawley D Dhokia R Sales J Darwish N Molloy S

With the identification of literature shortfalls on the techniques employed in intraoperative navigated (ION) spinal surgery, we outline a number of measures which have been synthesised into a coherent operative technique. These include positioning, dissection, management of the reference frame, the grip, the angle of attack, the drill, the template, the pedicle screw, the wire, and navigated intrathecal analgesia. Optimizing techniques to improve accuracy allow an overall reduction of the repetition of the surgical steps with its associated productivity benefits including time, cost, radiation, and safety.

Cite this article: Bone Joint J 2020;102-B(3):371–375.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 75 - 82
1 Jan 2019
Kim J Lee SY Jung JH Kim SW Oh J Park MS Chang H Kim T

Aims

The aim of this study was to evaluate the outcome of spinal instrumentation in haemodialyzed patients with native pyogenic spondylodiscitis. Spinal instrumentation in these patients can be dangerous due to rates of complications and mortality, and biofilm formation on the instrumentation.

Patients and Methods

A total of 134 haemodialyzed patients aged more than 50 years who underwent surgical treatment for pyogenic spondylodiscitis were included in the study. Their mean age was 66.4 years (50 to 83); 66 were male (49.3%) and 68 were female (50.7%). They were divided into two groups according to whether spinal instrumentation was used or not. Propensity score matching was used to attenuate the potential selection bias. The outcome of treatment was compared between these two groups.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1187 - 1200
1 Sep 2018
Subramanian T Ahmad A Mardare DM Kieser DC Mayers D Nnadi C

Aims

Magnetically controlled growing rod (MCGR) systems use non-invasive spinal lengthening for the surgical treatment of early-onset scoliosis (EOS). The primary aim of this study was to evaluate the performance of these devices in the prevention of progression of the deformity. A secondary aim was to record the rate of complications.

Patients and Methods

An observational study of 31 consecutive children with EOS, of whom 15 were male, who were treated between December 2011 and October 2017 was undertaken. Their mean age was 7.7 years (2 to 14). The mean follow-up was 47 months (24 to 69). Distractions were completed using the tailgating technique. The primary outcome measure was correction of the radiographic deformity. Secondary outcomes were growth, functional outcomes and complication rates.


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1658 - 1664
1 Dec 2017
Ahmad A Subramanian T Panteliadis P Wilson-Macdonald J Rothenfluh DA Nnadi C

Aims

Magnetically controlled growing rods (MCGRs) allow non-invasive correction of the spinal deformity in the treatment of early-onset scoliosis. Conventional growing rod systems (CGRS) need repeated surgical distractions: these are associated with the effect of the ‘law of diminishing returns’.

The primary aim of this study was to quantify this effect in MCGRs over sequential distractions.

Patients and Methods

A total of 35 patients with a maximum follow-up of 57 months were included in the study. There were 17 boys and 18 girls with a mean age of 7.4 years (2 to 14). True Distraction (TD) was determined by measuring the expansion gap on fluoroscopy. This was compared with Intended Distraction (ID) and expressed as the ‘T/I’ ratio. The T/I ratio and the Cobb angle were calculated at several time points during follow-up.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1366 - 1372
1 Oct 2017
Rickert M Fleege C Tarhan T Schreiner S Makowski MR Rauschmann M Arabmotlagh M

Aims

We compared the clinical and radiological outcomes of using a polyetheretherketone cage with (TiPEEK) and without a titanium coating (PEEK) for instrumented transforaminal lumbar interbody fusion (TLIF).

Materials and Methods

We conducted a randomised clinical pilot trial of 40 patients who were scheduled to undergo a TLIF procedure at one or two levels between L2 and L5. The Oswestry disability index (ODI), EuroQoL-5D, and back and leg pain were determined pre-operatively, and at three, six, and 12 months post-operatively. Fusion rates were assessed by thin slice CT at three months and by functional radiography at 12 months.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1373 - 1380
1 Oct 2017
Rienmüller A Buchmann N Kirschke JS Meyer EL Gempt J Lehmberg J Meyer B Ryang YM

Aims

We aimed to retrospectively assess the accuracy and safety of CT navigated pedicle screws and to compare accuracy in the cervical and thoracic spine (C2-T8) with (COMB) and without (POST) prior anterior surgery (anterior cervical discectomy or corpectomy and fusion with ventral plating: ACDF/ACCF).

Patients and Methods

A total of 592 pedicle screws, which were used in 107 consecutively operated patients (210 COMB, 382 POST), were analysed. The accuracy of positioning was determined according to the classification of Gertzbein and Robbins on post-operative CT scans.


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1080 - 1087
1 Aug 2017
Tsirikos AI Mataliotakis G Bounakis N

Aims

We present the results of correcting a double or triple curve adolescent idiopathic scoliosis using a convex segmental pedicle screw technique.

Patients and Methods

We reviewed 191 patients with a mean age at surgery of 15 years (11 to 23.3). Pedicle screws were placed at the convexity of each curve. Concave screws were inserted at one or two cephalad levels and two caudal levels. The mean operating time was 183 minutes (132 to 276) and the mean blood loss 0.22% of the total blood volume (0.08% to 0.4%). Multimodal monitoring remained stable throughout the operation. The mean hospital stay was 6.8 days (5 to 15).


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 944 - 950
1 Jul 2017
Fan G Fu Q Zhang J Zhang H Gu X Wang C Gu G Guan X Fan Y He S

Aims

Minimally invasive transforaminal lumbar interbody fusion (MITLIF) has been well validated in overweight and obese patients who are consequently subject to a higher radiation exposure. This prospective multicentre study aimed to investigate the efficacy of a novel lumbar localisation system for MITLIF in overweight patients.

Patients and Methods

The initial study group consisted of 175 patients. After excluding 49 patients for various reasons, 126 patients were divided into two groups. Those in Group A were treated using the localisation system while those in Group B were treated by conventional means. The primary outcomes were the effective radiation dosage to the surgeon and the exposure time.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1222 - 1226
1 Sep 2016
Joestl J Lang N Bukaty A Platzer P

Aims. We performed a retrospective, comparative study of elderly patients with an increased risk from anaesthesia who had undergone either anterior screw fixation (ASF) or halo vest immobilisation (HVI) for a type II odontoid fracture. Patients and Methods. A total of 80 patients aged 65 years or more who had undergone either ASF or HVI for a type II odontoid fracture between 1988 and 2013 were reviewed. There were 47 women and 33 men with a mean age of 73 (65 to 96; standard deviation 7). All had an American Society of Anesthesiologists score of 2 or more. Results. Patients who underwent ASF had a significantly better outcome than those who were treated by HVI. There was a rate of nonunion of 10% after ASF and 23% after HVI. Failure of reduction or fixation occurred in 11 patients (15%) but there was no significant difference between the two groups. Mortality rates were also similar: 9% (n = 3) after ASF and 8% (n = 4) after HVI. Conclusion. We conclude that ASF is the preferred method of treatment in this group of elderly patients, having a significantly higher rate of fusion, better clinical outcome and a similar rate of general and treatment-related complications. Cite this article: Bone Joint J 2016;98-B:1222–6


Bone & Joint Research
Vol. 5, Issue 9 | Pages 419 - 426
1 Sep 2016
Leichtle CI Lorenz A Rothstock S Happel J Walter F Shiozawa T Leichtle UG

Objectives

Cement augmentation of pedicle screws could be used to improve screw stability, especially in osteoporotic vertebrae. However, little is known concerning the influence of different screw types and amount of cement applied. Therefore, the aim of this biomechanical in vitro study was to evaluate the effect of cement augmentation on the screw pull-out force in osteoporotic vertebrae, comparing different pedicle screws (solid and fenestrated) and cement volumes (0 mL, 1 mL or 3 mL).

Materials and Methods

A total of 54 osteoporotic human cadaver thoracic and lumbar vertebrae were instrumented with pedicle screws (uncemented, solid cemented or fenestrated cemented) and augmented with high-viscosity PMMA cement (0 mL, 1 mL or 3 mL). The insertion torque and bone mineral density were determined. Radiographs and CT scans were undertaken to evaluate cement distribution and cement leakage. Pull-out testing was performed with a material testing machine to measure failure load and stiffness. The paired t-test was used to compare the two screws within each vertebra.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1099 - 1105
1 Aug 2016
Weiser L Dreimann M Huber G Sellenschloh K Püschel K Morlock MM Rueger JM Lehmann W

Aims

Loosening of pedicle screws is a major complication of posterior spinal stabilisation, especially in the osteoporotic spine. Our aim was to evaluate the effect of cement augmentation compared with extended dorsal instrumentation on the stability of posterior spinal fixation.

Materials and Methods

A total of 12 osteoporotic human cadaveric spines (T11-L3) were randomised by bone mineral density into two groups and instrumented with pedicle screws: group I (SHORT) separated T12 or L2 and group II (EXTENDED) specimen consisting of T11/12 to L2/3. Screws were augmented with cement unilaterally in each vertebra. Fatigue testing was performed using a cranial-caudal sinusoidal, cyclic (1.0 Hz) load with stepwise increasing peak force.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 834 - 839
1 Jun 2016
Wang S Ma H Lin C Chou P Liu C Yu W Chang M

Aim

Many aspects of the surgical treatment of patients with tuberculosis (TB) of the spine, including the use of instrumentation and the types of graft, remain controversial. Our aim was to report the outcome of a single-stage posterior procedure, with or without posterior decompression, in this group of patients.

Patients and Methods

Between 2001 and 2010, 51 patients with a mean age of 62.5 years (39 to 86) underwent long posterior instrumentation and short posterior or posterolateral fusion for TB of the thoracic and lumbar spines, followed by anti-TB chemotherapy for 12 months. No anterior debridement of the necrotic tissue was undertaken. Posterior decompression with laminectomy was carried out for the 30 patients with a neurological deficit.