The aim of this study was to compare the pain caused by the application
of a tourniquet after exsanguination of the upper limb with that
occurring after simple elevation. We used 26 healthy volunteers (52 arms), each of whom acted as
their own matched control. The primary outcome measure was the total pain experienced by
each volunteer while the tourniquet was inflated for 20 minutes.
This was calculated as the area under the pain curve for each individual
subject. Secondary outcomes were pain at each time point; the total
pain experienced during the recovery phase; the ability to tolerate the
tourniquet and the time for full recovery after deflation of the
tourniquet. Aims
Patients and Methods
We present a review of claims made to the NHS
Litigation Authority (NHSLA) by patients with conditions affecting the
shoulder and elbow, and identify areas of dissatisfaction and potential
improvement. Between 1995 and 2012, the NHSLA recorded 811 claims
related to the shoulder and elbow, 581 of which were settled. This
comprised 364 shoulder (64%), and 217 elbow (36%) claims. A total
of £18.2 million was paid out in settled claims. Overall diagnosis,
mismanagement and intra-operative nerve injury were the most common
reasons for litigation. The highest cost paid out resulted from
claims dealing with incorrect, missed or delayed diagnosis, with
just under £6 million paid out overall. Fractures and dislocations
around the shoulder and elbow were common injuries in this category.
All 11 claims following wrong-site surgery that were settled led
to successful payouts. This study highlights the diagnoses and procedures that need
to be treated with particular vigilance. Having an awareness of
the areas that lead to litigation in shoulder and elbow surgery
will help to reduce inadvertent risks to patients and prevent dissatisfaction
and possible litigation. Cite this article:
We performed a systematic review of the literature to determine
whether earlier surgical repair of acute rotator cuff tear (ARCT)
leads to superior post-operative clinical outcomes. The MEDLINE, Embase, CINAHL, Web of Science, Cochrane Libraries,
controlled-trials.com and clinicaltrials.gov databases were searched
using the terms: ‘rotator cuff’, or ‘supraspinatus’, or ‘infraspinatus’,
or ‘teres minor’, or ‘subscapularis’ AND ‘surgery’ or ‘repair’.
This gave a total of 15 833 articles. After deletion of duplicates
and the review of abstracts and full texts by two independent assessors,
15 studies reporting time to surgery for ARCT repair were included.
Studies were grouped based on time to surgery <
3 months (group
A, seven studies), or >
3 months (group B, eight studies). Weighted
means were calculated and compared using Student’s Aims
Methods
The purpose of this study was to compare the
outcome and complications of endoscopic versus open
release for the treatment of de Quervain’s tenosynovitis. Patients
with this condition were randomised to undergo either endoscopic (n
= 27) or open release (n = 25). Visual Analogue Scale (VAS) pain
and Disabilities of Arm, Shoulder, and Hand (DASH) scores were measured
at 12 and 24 weeks after surgery. Scar
Most patients with a nightstick fracture of the
ulna are treated conservatively. Various techniques of immobilisation or
early mobilisation have been studied. We performed a systematic
review of all published randomised controlled trials and observational
studies that have assessed the outcome of these fractures following
above- or below-elbow immobilisation, bracing and early mobilisation.
We searched multiple electronic databases, related bibliographies and
other studies. We included 27 studies comprising 1629 fractures
in the final analysis. The data relating to the time to radiological
union and the rates of delayed union and nonunion could be pooled
and analysed statistically. We found that early mobilisation produced the shortest radiological
time to union (mean 8.0 weeks) and the lowest mean rate of nonunion
(0.6%). Fractures treated with above- or below-elbow immobilisation
and braces had longer mean radiological times to union (9.2 weeks,
9.2 weeks and 8.7 weeks, respectively) and higher mean rates of
nonunion (3.8%, 2.1% and 0.8%, respectively). There was no statistically
significant difference in the rate of non- or delayed union between
those treated by early mobilisation and the three forms of immobilisation
(p = 0.142 to p = 1.000, respectively). All the studies had significant
biases, but until a robust randomised controlled trial is undertaken
the best advice for the treatment of undisplaced or partially displaced
nightstick fractures appears to be early mobilisation, with a removable
forearm support for comfort as required. Cite this article:
The sternoclavicular joint (SCJ) is a pivotal
articulation in the linked system of the upper limb girdle, providing
load-bearing in compression while resisting displacement in tension
or distraction at the manubrium sterni. The SCJ and acromioclavicular
joint (ACJ) both have a small surface area of contact protected
by an intra-articular fibrocartilaginous disc and are supported
by strong extrinsic and intrinsic capsular ligaments. The function
of load-sharing in the upper limb by bulky periscapular and thoracobrachial
muscles is extremely important to the longevity of both joints.
Ligamentous and capsular laxity changes with age, exposing both
joints to greater strain, which may explain the rising incidence
of arthritis in both with age. The incidence of arthritis in the
SCJ is less than that in the ACJ, suggesting that the extrinsic
ligaments of the SCJ provide greater stability than the coracoclavicular
ligaments of the ACJ. Instability of the SCJ is rare and can be difficult to distinguish
from medial clavicular physeal or metaphyseal fracture-separation:
cross-sectional imaging is often required. The distinction is important
because the treatment options and outcomes of treatment are dissimilar,
whereas the treatment and outcomes of ACJ separation and fracture
of the lateral clavicle can be similar. Proper recognition and treatment
of traumatic instability is vital as these injuries may be life-threatening.
Instability of the SCJ does not always require surgical intervention.
An accurate diagnosis is required before surgery can be considered,
and we recommend the use of the Stanmore instability triangle. Most
poor outcomes result from a failure to recognise the underlying
pathology. There is a natural reluctance for orthopaedic surgeons to operate
in this area owing to unfamiliarity with, and the close proximity
of, the related vascular structures, but the interposed sternohyoid
and sternothyroid muscles are rarely injured and provide a clear
boundary to the medial retroclavicular space, as well as an anatomical
barrier to unsafe intervention. This review presents current concepts of instability of the SCJ,
describes the relevant surgical anatomy, provides a framework for
diagnosis and management, including physiotherapy, and discusses
the technical challenges of operative intervention. Cite this article:
The purpose of this study was to assess the clinical
and radiological outcomes of dorsal intercarpal ligament capsulodesis
for the treatment of static scapholunate instability at a minimum
follow-up of four years. A total of 59 patients who underwent capsulodesis
for this condition were included in a retrospective analysis after
a mean of 8.25 years (4.3 to 12). A total of eight patients underwent
a salvage procedure at a mean of 2.33 years (0.67 to 7.6) and were
excluded. The mean range of extension/flexion was 88° (15° to 135°)
and of ulnar/radial deviation was 38° (0° to 75°) at final follow-up.
The mean Disabilities of the Arm Shoulder and Hand (DASH) score
and Mayo wrist scores were 28 (0 to 85) and 61 (0 to 90), respectively Capsulodesis did not maintain carpal reduction over time. Although
the consequent ongoing scapholunate instability resulted in early
arthritic degeneration, most patients had acceptable long-term function
of the wrist.
The Motec cementless modular metal-on-metal ball-and-socket
wrist arthroplasty was implanted in 16 wrists with scaphoid nonunion
advanced collapse (SNAC; grades 3 or 4) and 14 wrists with scapholunate
advanced collapse (SLAC) in 30 patients (20 men) with severe (grades
3 or 4) post-traumatic osteoarthritis of the wrist. The mean age of
the patients was 52 years (31 to 71). All prostheses integrated
well radiologically. At a mean follow-up of 3.2 years (1.1 to 6.1)
no luxation or implant breakage occurred. Two wrists were converted
to an arthrodesis for persistent pain. Loosening occurred in one
further wrist at five years post-operatively. The remainder demonstrated close
bone–implant contact. The clinical results were good, with markedly
decreased Disabilities of the Arm Shoulder and Hand (DASH) and pain
scores, and increased movement and grip strength. No patient used
analgesics and most had returned to work. Good short-term function was achieved using this wrist arthroplasty
in a high-demand group of patients with post-traumatic osteoarthritis.
We systematically reviewed all the evidence published
in the English language on proximal interphalangeal joint (PIPJ)
replacement, to determine its effectiveness on the function of the
hand and the associated post-operative complications. Original studies were selected if they reported clinical outcome
with a minimum of one year’s follow-up. Quality was assessed using
the Cowley systematic review criteria modified for finger-joint
replacements. Of 319 articles identified, only five were adequately
reported according to our quality criteria; there were no randomised
controlled trials. PIPJ replacements had a substantial effect size
on hand pain of -23.2 (95% confidence interval (CI) -27.3 to -19.1)
and grip strength 1.2 (95% CI -10.7 to 13.1), and a small effect
on range of movement 0.2 (95% CI -0.4 to 0.8). A dorsal approach
was most successful. Post-operative loosening occurred in 10% (95%
CI 3 to 30) of ceramic and 12.5% (95% CI 7 to 21) of pyrocarbon
replacements. Post-operative complications occurred in 27.8% (95%
CI 20 to 37). We conclude that the effectiveness of PIPJ replacement has not
been established. Small observational case studies and short-term
follow-up, together with insufficient reporting of patient data,
functional outcomes and complications, limit the value of current
evidence. We recommend that a defined core set of patients, surgical and
outcome data for this intervention be routinely and systematically
collected within the framework of a joint registry.
Injectable collagenase is an alternative to surgical
treatment for Dupuytren’s disease. Previous studies have reported
on the effectiveness of collagenase in finger contractures. This
prospective study reports on the short-term safety and efficacy
of collagenase treatment in five thumb and first web space Dupuytren’s
contractures. The thumb and first web space contractures were treated
with injectable collagenase in four consecutive patients (five hands) with
experience of previous surgical digital fasciectomy. The thumb contracture
was measured by angle and span in two planes of thumb extension
and abduction before injection and after manipulation. Collagenase
treatment resulted in release of the contracture with a mean increase
in thumb to index angle from 23° (10° to 35°) to 56° (45° to 60°)
in extension and from 30° (10° to 50°) to 58° (50° to 65°) in abduction
and a mean increase in span from 1.9 cm (1 to 3.5) to 3.9 cm (3
to 5) in extension and from 2.4 cm (1.5 to 3.5) to 3.9 cm (3 to
4.5) in abduction. All patients reported an increased range of movement
and function and described collagenase therapy as preferable to
surgery. In the short-term collagenase is an effective, well-tolerated
and safe alternative to surgery for Dupuytren’s disease of the thumb.
There is little information about the management
of peri-prosthetic fracture of the humerus after total shoulder replacement
(TSR). This is a retrospective review of 22 patients who underwent
a revision of their original shoulder replacement for peri-prosthetic
fracture of the humerus with bone loss and/or loose components.
There were 20 women and two men with a mean age of 75 years (61
to 90) and a mean follow-up 42 months (12 to 91): 16 of these had
undergone a previous revision TSR. Of the 22 patients, 12 were treated
with a long-stemmed humeral component that bypassed the fracture.
All their fractures united after a mean of 27 weeks (13 to 94).
Eight patients underwent resection of the proximal humerus with
endoprosthetic replacement to the level of the fracture. Two patients
were managed with a clam-shell prosthesis that retained the original
components. The mean Oxford shoulder score (OSS) of the original
TSRs before peri-prosthetic fracture was 33 (14 to 48). The mean
OSS after revision for fracture was 25 (9 to 31). Kaplan-Meier survival
using re-intervention for any reason as the endpoint was 91% (95%
confidence interval (CI) 68 to 98) and 60% (95% CI 30 to 80) at
one and five years, respectively. There were two revisions for dislocation of the humeral head,
one open reduction for modular humeral component dissociation, one
internal fixation for nonunion, one trimming of a prominent screw
and one re-cementation for aseptic loosening complicated by infection,
ultimately requiring excision arthroplasty. Two patients sustained
nerve palsies. Revision TSR after a peri-prosthetic humeral fracture associated
with bone loss and/or loose components is a salvage procedure that
can provide a stable platform for elbow and hand function. Good
rates of union can be achieved using a stem that bypasses the fracture.
There is a high rate of complications and function is not as good as
with the original replacement.
Objectives. The aim of this study was to determine whether there is any significant
difference in temporal measurements of pain, function and rates
of re-tear for arthroscopic rotator cuff repair (RCR) patients compared
with those patients undergoing open RCR. Methods. This study compared questionnaire- and clinical examination-based
outcomes over two years or longer for two series of patients who
met the inclusion criteria: 200 open RCR and 200 arthroscopic RCR
patients. All surgery was performed by a single surgeon. . Results. Most pain measurements were similar for both groups. However, the
arthroscopic RCR group reported less night pain severity at six
months, less extreme pain and greater
Scapulothoracic fusion (STF) for painful winging
of the scapula in neuromuscular disorders can provide effective pain
relief and functional improvement, but there is little information
comparing outcomes between patients with dystrophic and non-dystrophic
conditions. We performed a retrospective review of 42 STFs in 34
patients with dystrophic and non-dystrophic conditions using a multifilament
trans-scapular, subcostal cable technique supported by a dorsal
one-third semi-tubular plate. There were 16 males and 18 females
with a mean age of 30 years (15 to 75) and a mean follow-up of 5.0
years (2.0 to 10.6). The mean Oxford shoulder score improved from
20 (4 to 39) to 31 (4 to 48). Patients with non-dystrophic conditions
had lower overall functional scores but achieved greater improvements
following STF. The mean active forward elevation increased from
59° (20° to 90°) to 97° (30° to 150°), and abduction from 51° (10°
to 90°) to 83° (30° to 130°) with a greater range of movement achieved
in the dystrophic group. Revision fusion for nonunion was undertaken
in five patients at a mean time of 17 months (7 to 31) and two required
revision for fracture. There were three pneumothoraces, two rib
fractures, three pleural effusions and six nonunions. The main risk
factors for nonunion were smoking, age and previous shoulder girdle surgery. STF is a salvage procedure that can provide good patient satisfaction
in 82% of patients with both dystrophic and non-dystrophic pathologies,
but there was a relatively high failure rate (26%) when poor outcomes
were analysed. Overall function was better in patients with dystrophic
conditions which correlated with better range of movement; however,
patients with non-dystrophic conditions achieved greater functional
improvement.
The aim of this study was to compare a third-generation
cementing procedure for glenoid components with a new technique
for cement pressurisation. In 20 pairs of scapulae, 20 keeled and
20 pegged glenoid components were implanted using either a third-generation
cementing technique (group 1) or a new pressuriser (group 2). Cement penetration
was measured by three-dimensional (3D) analysis of micro-CT scans.
The mean 3D depth of penetration of the cement was significantly
greater in group 2 (p <
0.001). The mean thickness of the cement
mantle for keeled glenoids was 2.50 mm (2.0 to 3.3) in group 1 and
5.18 mm (4.4 to 6.1) in group 2, and for pegged glenoids it was 1.72 mm
(0.9 to 2.3) in group 1 and 5.63 mm (3.6 to 6.4) in group 2. A cement
mantle <
2 mm was detected less frequently in group 2 (p <
0.001). Using the cement pressuriser the proportion of cement mantles
<
2 mm was significantly reduced compared with the third-generation
cementing technique.
We investigated the clinical response to arthroscopic
synovectomy in patients with undifferentiated chronic monoarthritis
(UCMA) of the wrist. Arthroscopic synovectomy was performed on 20
wrists in 20 patients with UCMA of the wrist who had not responded
to non-steroidal anti-inflammatory drugs. The mean duration of symptoms
at the time of surgery was 4.3 months (3 to 7) and the mean follow-up
was 51.8 months (24 to 94). Inflamed synovium was completely removed
from the radiocarpal, midcarpal and distal radioulnar joints using
more portals than normal. After surgery, nine patients had early
remission of synovitis and 11 with uncontrolled synovitis received
antirheumatic medication. Overall, there was significant improvement
in terms of pain relief, range of movement and Mayo score. Radiological
deterioration was seen in five patients who were diagnosed as having rheumatoid
arthritis during the follow-up period. Lymphoid follicles and severe
lymphocyte infiltration were seen more often in synovial biopsies
from patients with uncontrolled synovitis. These results suggest that arthroscopic synovectomy provides
pain relief and functional improvement, and allows rapid resolution
of synovitis in about half of patients with UCMA of the wrist.
In light of the growing number of elderly osteopenic
patients with distal humeral fractures, we discuss the history of
their management and current trends. Under most circumstances operative
fixation and early mobilisation is the treatment of choice, as it
gives the best results. The relative indications for and results
of total elbow replacement
Radiological changes and differences between cemented and uncemented components of Grammont reverse shoulder arthroplasties (DePuy) were analysed at a mean follow-up of 9.6 years (8 to 12). Of 122 reverse shoulder arthroplasties implanted in five shoulder centres between 1993 and 2000, a total of 68 (65 patients) were available for study. The indications for reversed shoulder arthroplasty were cuff tear arthropathy in 48 shoulders, revision of shoulder prostheses of various types in 11 and massive cuff tear in nine. The development of scapular notching, bony scapular spur formation, heterotopic ossification, glenoid and humeral radiolucencies, stem subsidence, radiological signs of stress shielding and resorption of the tuberosities were assessed on standardised true anteroposterior and axillary radiographs. A scapular notch was observed in 60 shoulders (88%) and was associated with the superolateral approach (p = 0.009). Glenoid radiolucency was present in 11 (16%), bony scapular spur and/or ossifications in 51 (75%), and subsidence of the stem and humeral radiolucency in more than three zones were present in three (8.8%) and in four (11.8%) of 34 cemented components, respectively, and in one (2.9%) and two (5.9%) of 34 uncemented components, respectively. Radiological signs of stress shielding were significantly more frequent with uncemented components (p <
0.001), as was resorption of the greater (p <
0.001) and lesser tuberosities (p = 0.009).
Mason type III fractures of the radial head are treated by open reduction and internal fixation, resection or prosthetic joint replacement. When internal fixation is performed, fixation of the radial head to the shaft is difficult and implant-related complications are common. Furthermore, problems of devascularisation of the radial head can result from fixation of the plate to the radial neck. In a small retrospective study, the treatment of Mason type III fractures with fixation of the radial neck in 13 cases (group 2) was compared with 12 cases where no fixation was performed (group 1). The mean clinical and radiological follow-up was four years (1 to 9). The Broberg-Morrey index showed excellent results in both groups. Degenerative radiological changes were seen more frequently in group 2, and removal of the implant was necessary in seven of 13 cases. Post-operative evaluation of these two different techniques revealed similar ranges of movement and functional scores. We propose that anatomical reconstruction of the radial head without metalwork fixation to the neck is preferable, and the outcome is the same as that achieved with the conventional technique. In addition degenerative changes of the elbow joint may develop less frequently, and implant removal is not necessary.
The combination of an irreparable tear of the rotator cuff and destructive arthritis of the shoulder joint may cause severe pain, disability and loss of independence in the aged. Standard anatomical shoulder replacements depend on a functioning rotator cuff, and hence may fail in the presence of tears in the cuff. Many designs of non-anatomical constrained or semi-constrained prostheses have been developed for cuff tear arthropathy, but have proved unsatisfactory and were abandoned. The DePuy Delta III reverse prosthesis, designed by Grammont, medialises and stabilises the centre of rotation of the shoulder joint and has shown early promise. This study evaluated the mid-term clinical and radiological results of this arthroplasty in a consecutive series of 50 shoulders in 43 patients with a painful pseudoparalysis due to an irreparable cuff tear and destructive arthritis, performed over a period of seven years by a single surgeon. A follow-up of 98% was achieved, with a mean duration of 39 months (8 to 81). The mean age of the patients at the time of surgery was 81 years (59 to 95). The female to male ratio was 5:1. During the seven years, six patients died of natural causes. The clinical outcome was assessed using the American Shoulder and Elbow score, the Oxford Shoulder Score and the Short-form 36 score. A radiological review was performed using the Sirveaux score for scapular notching. The mean American Shoulder and Elbow score was 19 (95% confidence interval (CI) 14 to 23) pre-operatively, and 65 (95% CI 48 to 82) (paired The mean maximum elevation improved from 55° pre-operatively to 105° at final follow-up. There were seven complications during the whole series, although only four patients required further surgery.
Total shoulder replacement is a successful procedure for degenerative or some inflammatory diseases of the shoulder. However, fixation of the glenoid seems to be the main weakness with a high rate of loosening. The results using all-polyethylene components have been better than those using metal-backed components. We describe our experience with 35 consecutive total shoulder replacements using a new metal-backed glenoid component with a mean follow-up of 75.4 months (48 to 154). Our implant differs from others because of its mechanism of fixation. It has a convex metal-backed bone interface and the main stabilising factor is a large hollow central peg. The patients were evaulated with standard radiographs and with the Constant Score, the Simple Shoulder Test and a visual analogue scale. All the scores improved and there was no loosening, no polyethylene-glenoid disassembly and no other implant-related complications. We conclude that a metal-backed glenoid component is a good option in total shoulder replacement with no worse results than of those using a cemented all-polyethylene prosthesis.