Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Bone & Joint Open
Vol. 3, Issue 2 | Pages 165 - 172
21 Feb 2022
Kuwahara Y Takegami Y Tokutake K Yamada Y Komaki K Ichikawa T Imagama S

Aims

Postoperative malalignment of the femur is one of the main complications in distal femur fractures. Few papers have investigated the impact of intraoperative malalignment on postoperative function and bone healing outcomes. The aim of this study was to investigate how intraoperative fracture malalignment affects postoperative bone healing and functional outcomes.

Methods

In total, 140 patients were retrospectively identified from data obtained from a database of hospitals participating in a trauma research group. We divided them into two groups according to coronal plane malalignment of more than 5°: 108 had satisfactory fracture alignment (< 5°, group S), and 32 had unsatisfactory alignment (> 5°, group U). Patient characteristics and injury-related factors were recorded. We compared the rates of nonunion, implant failure, and reoperation as healing outcomes and Knee Society Score (KSS) at three, six, and 12 months as functional outcomes. We also performed a sub-analysis to assess the effect of fracture malalignment by plates and nails on postoperative outcomes.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 294 - 298
1 Feb 2021
Hadeed MM Prakash H Yarboro SR Weiss DB

Aims. The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols. Methods. A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals. Results. The spiral and oblique fracture patterns withstood simulated weight-bearing with minimal displacement. The multifragmented model had early implant failure with breaking of the distal locking screws. The spiral fracture model shortened by a mean of 0.3 mm (SD 0.2), and developed a mean coronal angulation of 2.0° (SD 1.9°) and a mean sagittal angulation of 1.2° (SD 1.1°). On average, 88% of the shortening, 74% of the change in coronal alignment, and 75% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. The oblique fracture model shortened by a mean of 0.2 mm (SD 0.1) and developed a mean coronal angulation of 2.4° (SD 1.6°) and a mean sagittal angulation of 2.6° (SD 1.4°). On average, 44% of the shortening, 39% of the change in coronal alignment, and 79% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. Conclusion. For spiral and oblique fracture patterns, simulated weight-bearing resulted in a clinically acceptable degree of displacement. Most displacement occurred early in the test period, and the rate of displacement decreased over time. Based on this model, we offer evidence that early weight-bearing appears safe for well reduced oblique and spiral fractures, but not in multifragmented patterns that have poor bone contact. Cite this article: Bone Joint J 2021;103-B(2):294–298


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 246 - 249
1 Feb 2010
Jain AK Dhammi IK Singh AP Mishra P

The optimal method for the management of neglected traumatic bifacetal dislocation of the subaxial cervical spine has not been established. We treated four patients in whom the mean delay between injury and presentation was four months (1 to 5). There were two dislocations at the C5-6 level and one each at C4-5 and C3-4. The mean age of the patients was 48.2 years (27 to 60). Each patient presented with neck pain and restricted movement of the cervical spine. Three of the four had a myelopathy. We carried out a two-stage procedure under the same anaesthetic. First, a posterior soft-tissue release and partial facetectomy were undertaken. This allowed partial reduction of the dislocation which was then supplemented by interspinous wiring and corticocancellous graft. Next, through an anterior approach, discectomy, tricortical bone grafting and anterior cervical plating were carried out. All the patients achieved a nearly anatomical reduction and sagittal alignment. The mean follow-up was 2.6 years (1 to 4). The myelopathy settled completely in the three patients who had a pre-operative neurological deficit. There was no graft dislodgement or graft-related problems. Bony fusion occurred in all patients and a satisfactory reduction was maintained. The posteroanterior procedure for neglected traumatic bifacetal dislocation of the subaxial cervical spine is a good method of achieving sagittal alignment with less risk of iatrogenic neurological injury, a reduced operating time, decreased blood loss, and a shorter hospital stay compared with other procedures


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1495 - 1497
1 Nov 2007
Jones BG Mehin R Young D

Intramedullary tibial nailing was performed in ten paired cadavers and the insertion of a medial-to-lateral proximal oblique locking screw was simulated in each specimen. Anatomical dissection was undertaken to determine the relationship of the common peroneal nerve to the cross-screw.

The common peroneal nerve was contacted directly in four tibiae and the cross-screw was a mean of 2.6 mm (1.0 to 10.7) away from the nerve in the remaining 16. Iatrogenic injury to the common peroneal nerve by medial-to-lateral proximal oblique locking screws is therefore a significant risk during tibial nailing.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1361 - 1366
1 Oct 2006
Moroz LA Launay F Kocher MS Newton PO Frick SL Sponseller PD Flynn JM

Between 1996 and 2003 six institutions in the United States and France contributed a consecutive series of 234 fractures of the femur in 229 children which were treated by titanium elastic nailing. Minor or major complications occurred in 80 fractures. Full information was available concerning 230 fractures, of which the outcome was excellent in 150 (65%), satisfactory in 57 (25%), and poor in 23 (10%). Poor outcomes were due to leg-length discrepancy in five fractures, unacceptable angulation in 17, and failure of fixation in one. There was a statistically significant relationship (p = 0.003) between age and outcome, and the odds ratio for poor outcome was 3.86 for children aged 11 years and older compared with those below this age. The difference between the weight of children with a poor outcome and those with an excellent or satisfactory outcome was statistically significant (54 kg vs 39 kg; p = 0.003). A poor outcome was five times more likely in children who weighed more than 49 kg.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 692 - 697
1 May 2005
Topliss CJ Jackson M Atkins RM

In a series of 126 consecutive pilon fractures, we have described anatomically explicable fragments. Fracture lines describing these fragments have revealed ten types of pilon fracture which belong to two families, sagittal and coronal. The type of fracture is dictated by the energy of injury, the direction of the force of injury and the age of the patient.