The aims were to assess whether joint-specific outcome after total knee arthroplasty (TKA) was influenced by implant design over a 12-year follow-up period, and whether patient-related factors were associated with loss to follow-up and mortality risk. Long-term follow-up of a randomized controlled trial was undertaken. A total of 212 patients were allocated a Triathlon or a Kinemax TKA. Patients were assessed preoperatively, and one, three, eight, and 12 years postoperatively using the Oxford Knee Score (OKS). Reasons for patient lost to follow-up, mortality, and revision were recorded.Aims
Methods
The primary aim of this study is to quantify and compare outcomes following a dorsally displaced fracture of the distal radius in elderly patients (aged ≥ 65 years) who are managed conservatively versus with surgical fixation (open reduction and internal fixation). Secondary aims are to assess and compare upper limb-specific function, health-related quality of life, wrist pain, complications, grip strength, range of motion, radiological parameters, healthcare resource use, and cost-effectiveness between the groups. A prospectively registered (ISRCTN95922938) randomized parallel group trial will be conducted. Elderly patients meeting the inclusion criteria with a dorsally displaced distal radius facture will be randomized (1:1 ratio) to either conservative management (cast without further manipulation) or surgery. Patients will be assessed at six, 12, 26 weeks, and 52 weeks post intervention. The primary outcome measure and endpoint will be the Patient-Rated Wrist Evaluation (PRWE) at 52 weeks. In addition, the abbreviated version of the Disabilities of Arm, Shoulder and Hand questionnaire (QuickDASH), EuroQol five-dimension questionnaire, pain score (visual analogue scale 1 to 10), complications, grip strength (dynamometer), range of motion (goniometer), and radiological assessments will be undertaken. A cost-utility analysis will be performed to assess the cost-effectiveness of surgery. We aim to recruit 89 subjects per arm (total sample size 178).Aims
Methods
Despite the vast quantities of published artificial intelligence (AI) algorithms that target trauma and orthopaedic applications, very few progress to inform clinical practice. One key reason for this is the lack of a clear pathway from development to deployment. In order to assist with this process, we have developed the Clinical Practice Integration of Artificial Intelligence (CPI-AI) framework – a five-stage approach to the clinical practice adoption of AI in the setting of trauma and orthopaedics, based on the IDEAL principles ( Cite this article:
Total hip and knee arthroplasty (THA, TKA) are largely successful procedures; however, both have variable outcomes, resulting in some patients being dissatisfied with the outcome. Surgeons are turning to technologies such as robotic-assisted surgery in an attempt to improve outcomes. Robust studies are needed to find out if these innovations are really benefitting patients. The Robotic Arthroplasty Clinical and Cost Effectiveness Randomised Controlled Trials (RACER) trials are multicentre, patient-blinded randomized controlled trials. The patients have primary osteoarthritis of the hip or knee. The operation is Mako-assisted THA or TKA and the control groups have operations using conventional instruments. The primary clinical outcome is the Forgotten Joint Score at 12 months, and there is a built-in analysis of cost-effectiveness. Secondary outcomes include early pain, the alignment of the components, and medium- to long-term outcomes. This annotation outlines the need to assess these technologies and discusses the design and challenges when conducting such trials, including surgical workflows, isolating the effect of the operation, blinding, and assessing the learning curve. Finally, the future of robotic surgery is discussed, including the need to contemporaneously introduce and evaluate such technologies. Cite this article:
To perform an incremental cost-utility analysis and assess the impact of differential costs and case volume on the cost-effectiveness of robotic arm-assisted unicompartmental knee arthroplasty (rUKA) compared to manual (mUKA). This was a five-year follow-up study of patients who were randomized to rUKA (n = 64) or mUKA (n = 65). Patients completed the EuroQol five-dimension questionnaire (EQ-5D) preoperatively, and at three months and one, two, and five years postoperatively, which was used to calculate quality-adjusted life years (QALYs) gained. Costs for the primary and additional surgery and healthcare costs were calculated.Aims
Methods
Scoliosis is a lateral curvature of the spine with associated rotation, often causing distress due to appearance. For some curves, there is good evidence to support the use of a spinal brace, worn for 20 to 24 hours a day to minimize the curve, making it as straight as possible during growth, preventing progression. Compliance can be poor due to appearance and comfort. A night-time brace, worn for eight to 12 hours, can achieve higher levels of curve correction while patients are supine, and could be preferable for patients, but evidence of efficacy is limited. This is the protocol for a randomized controlled trial of ‘full-time bracing’ versus ‘night-time bracing’ in adolescent idiopathic scoliosis (AIS). UK paediatric spine clinics will recruit 780 participants aged ten to 15 years-old with AIS, Risser stage 0, 1, or 2, and curve size (Cobb angle) 20° to 40° with apex at or below T7. Patients are randomly allocated 1:1, to either full-time or night-time bracing. A qualitative sub-study will explore communication and experiences of families in terms of bracing and research. Patient and Public Involvement & Engagement informed study design and will assist with aspects of trial delivery and dissemination.Aims
Methods
Olecranon fractures are usually caused by falling directly on to the olecranon or following a fall on to an outstretched arm. Displaced fractures of the olecranon with a stable ulnohumeral joint are commonly managed by open reduction and internal fixation. The current predominant method of management of simple displaced fractures with ulnohumeral stability (Mayo grade IIA) in the UK and internationally is a low-cost technique using tension band wiring. Suture or suture anchor techniques have been described with the aim of reducing the hardware related complications and reoperation. An all-suture technique has been developed to fix the fracture using strong synthetic sutures alone. The aim of this trial is to investigate the clinical and cost-effectiveness of tension suture repair versus traditional tension band wiring for the surgical fixation of Mayo grade IIA fractures of the olecranon. SOFFT is a multicentre, pragmatic, two-arm parallel-group, non-inferiority, randomized controlled trial. Participants will be assigned 1:1 to receive either tension suture fixation or tension band wiring. 280 adult participants will be recruited. The primary outcome will be the Disabilities of the Arm, Shoulder and Hand (DASH) score at four months post-randomization. Secondary outcome measures include DASH (at 12, 18, and 24 months), pain, Net Promotor Score (patient satisfaction), EuroQol five-dimension five-level score (EQ-5D-5L), radiological union, complications, elbow range of motion, and re-operations related to the injury or to remove metalwork. An economic evaluation will assess the cost-effectiveness of treatments.Aims
Methods
This study reports the ten-year wear rates, incidence of osteolysis, clinical outcomes, and complications of a multicentre randomized controlled trial comparing oxidized zirconium (OxZr) versus cobalt-chrome (CoCr) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) and highly cross-linked polyethylene (XLPE) liners in total hip arthroplasty (THA). Patients undergoing primary THA were recruited from four institutions and prospectively allocated to the following treatment groups: Group A, CoCr femoral head with XLPE liner; Group B, OxZr femoral head with XLPE liner; and Group C, OxZr femoral head with UHMWPE liner. All study patients and assessors recording outcomes were blinded to the treatment groups. The outcomes of 262 study patients were analyzed at ten years’ follow-up.Aims
Methods
Hand trauma accounts for one in five of emergency department attendances, with a UK incidence of over five million injuries/year and 250,000 operations/year. Surgical site infection (SSI) in hand trauma surgery leads to further interventions, poor outcomes, and prolonged recovery, but has been poorly researched. Antimicrobial sutures have been recognized by both the World Health Organization and the National Institute for Clinical Excellence as potentially effective for reducing SSI. They have never been studied in hand trauma surgery: a completely different patient group and clinical pathway to previous randomized clinical trials (RCTs) of these sutures. Antimicrobial sutures are expensive, and further research in hand trauma is warranted before they become standard of care. The aim of this protocol is to conduct a feasibility study of antimicrobial sutures in patients undergoing hand trauma surgery to establish acceptability, compliance, and retention for a definitive trial. A two-arm, multicentre feasibility RCT of 116 adult participants with hand and wrist injuries, randomized to either antimicrobial sutures or standard sutures. Study participants and outcome assessors will be blinded to treatment allocation. Outcome measures will be recorded at baseline (preoperatively), 30 days, 90 days, and six months, and will include SSI, patient-reported outcome measures, and return to work.Aims
Methods
The aim of this study was to compare the clinical outcomes of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) during the first six weeks and at one year postoperatively. A per protocol analysis of 76 patients, 43 of whom underwent TKA and 34 of whom underwent bi-UKA, was performed from a prospective, single-centre, randomized controlled trial. Diaries kept by the patients recorded pain, function, and the use of analgesics daily throughout the first week and weekly between the second and sixth weeks. Patient-reported outcome measures (PROMs) were compared preoperatively, and at three months and one year postoperatively. Data were also compared longitudinally and a subgroup analysis was conducted, stratified by preoperative PROM status.Aims
Methods
This study evaluates the quality of patient-reported outcome measures (PROMs) reported in childhood fracture trials and recommends outcome measures to assess and report physical function, functional capacity, and quality of life using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) standards. A Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)-compliant systematic review of OVID Medline, Embase, and Cochrane CENTRAL was performed to identify all PROMs reported in trials. A search of OVID Medline, Embase, and PsycINFO was performed to identify all PROMs with validation studies in childhood fractures. Development studies were identified through hand-searching. Data extraction was undertaken by two reviewers. Study quality and risk of bias was evaluated by COSMIN guidelines and recorded on standardized checklists.Aims
Methods
Dislocation is the most common indication for further surgery following total hip arthroplasty (THA) when undertaken in patients with a femoral neck fracture. This study aimed to assess the complication rates of THA with dual mobility components (THA-DMC) following a femoral neck fracture and to compare outcomes between THA-DMC, conventional THA, and hemiarthroplasty (HA). We performed a systematic review of all English language articles on THA-DMC published between 2010 and 2019 in the MEDLINE, EMBASE, and Cochrane databases. After the application of rigorous inclusion and exclusion criteria, 23 studies dealing with patients who underwent treatment for a femoral neck fracture using THA-DMC were analyzed for the rate of dislocation. Secondary outcomes included reoperation, periprosthetic fracture, infection, mortality, and functional outcome. The review included 7,189 patients with a mean age of 77.8 years (66.4 to 87.6) and a mean follow-up of 30.9 months (9.0 to 68.0).Aims
Methods
There are comparatively few randomized studies evaluating knee arthroplasty prostheses, and fewer still that report longer-term functional outcomes. The aim of this study was to evaluate mid-term outcomes of an existing implant trial cohort to document changing patient function over time following total knee arthroplasty using longitudinal analytical techniques and to determine whether implant design chosen at time of surgery influenced these outcomes. A mid-term follow-up of the remaining 125 patients from a randomized cohort of total knee arthroplasty patients (initially comprising 212 recruited patients), comparing modern (Triathlon) and traditional (Kinemax) prostheses was undertaken. Functional outcomes were assessed with the Oxford Knee Score (OKS), knee range of movement, pain numerical rating scales, lower limb power output, timed functional assessment battery, and satisfaction survey. Data were linked to earlier assessment timepoints, and analyzed by repeated measures analysis of variance (ANOVA) mixed models, incorporating longitudinal change over all assessment timepoints.Aims
Methods
A pragmatic, single-centre, double-blind randomized clinical trial was conducted in a NHS teaching hospital to evaluate whether there is a difference in functional knee scores, quality-of-life outcome assessments, and complications at one-year after intervention between total knee arthroplasty (TKA) and patellofemoral arthroplasty (PFA) in patients with severe isolated patellofemoral arthritis. This parallel, two-arm, superiority trial was powered at 80%, and involved 64 patients with severe isolated patellofemoral arthritis. The primary outcome measure was the functional section of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score at 12 months. Secondary outcomes were the full 24-item WOMAC, Oxford Knee Score (OKS), American Knee Society Score (AKSS), EuroQol five dimension (EQ-5D) quality-of-life score, the University of California, Los Angeles (UCLA) Physical Activity Rating Scale, and complication rates collected at three, six, and 12 months. For longer-term follow-up, OKS, EQ-5D, and self-reported satisfaction score were collected at 24 and 60 months.Aims
Methods
Total knee arthroplasty (TKA) is an established
and successful procedure. However, the design of prostheses continues
to be modified in an attempt to optimise the functional outcome
of the patient. The aim of this study was to determine if patient outcome after
TKA was influenced by the design of the prosthesis used. A total of 212 patients (mean age 69; 43 to 92; 131 female (62%),
81 male (32%)) were enrolled in a single centre double-blind trial
and randomised to receive either a Kinemax (group 1) or a Triathlon
(group 2) TKA. Patients were assessed pre-operatively, at six weeks, six months,
one year and three years after surgery. The outcome assessments
used were the Oxford Knee Score; range of movement; pain numerical
rating scales; lower limb power output; timed functional assessment
battery and a satisfaction survey. Data were assessed incorporating
change over all assessment time points, using repeated measures
analysis of variance longitudinal mixed models. Implant group 2
showed a significantly greater range of movement (p = 0.009), greater
lower limb power output (p = 0.026) and reduced report of ‘worst
daily pain’ (p = 0.003) over the three years of follow-up. Differences
in Oxford Knee Score (p = 0.09), report of ‘average daily pain’
(p = 0.57) and timed functional performance tasks (p = 0.23) did
not reach statistical significance. Satisfaction with outcome was
significantly better in group 2 (p = 0.001). These results suggest that patient outcome after TKA can be influenced
by the prosthesis used. Cite this article: