Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 635 - 640
1 Jun 2023
Karczewski D Siljander MP Larson DR Taunton MJ Lewallen DG Abdel MP

Aims

Knowledge on total knee arthroplasties (TKAs) in patients with a history of poliomyelitis is limited. This study compared implant survivorship and clinical outcomes among affected and unaffected limbs in patients with sequelae of poliomyelitis undergoing TKAs.

Methods

A retrospective review of our total joint registry identified 94 patients with post-polio syndrome undergoing 116 primary TKAs between January 2000 and December 2019. The mean age was 70 years (33 to 86) with 56% males (n = 65) and a mean BMI of 31 kg/m2 (18 to 49). Rotating hinge TKAs were used in 14 of 63 affected limbs (22%), but not in any of the 53 unaffected limbs. Kaplan-Meier survivorship analyses were completed. The mean follow-up was eight years (2 to 19).


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1126 - 1131
1 Oct 2022
Hannon CP Kruckeberg BM Pagnano MW Berry DJ Hanssen AD Abdel MP

Aims

We have previously reported the mid-term outcomes of revision total knee arthroplasty (TKA) for flexion instability. At a mean of four years, there were no re-revisions for instability. The aim of this study was to report the implant survivorship and clinical and radiological outcomes of the same cohort of of patients at a mean follow-up of ten years.

Methods

The original publication included 60 revision TKAs in 60 patients which were undertaken between 2000 and 2010. The mean age of the patients at the time of revision TKA was 65 years, and 33 (55%) were female. Since that time, 21 patients died, leaving 39 patients (65%) available for analysis. The cumulative incidence of any re-revision with death as a competing risk was calculated. Knee Society Scores (KSSs) were also recorded, and updated radiographs were reviewed.


Bone & Joint Research
Vol. 7, Issue 1 | Pages 20 - 27
1 Jan 2018
Kang K Son J Suh D Kwon SK Kwon O Koh Y

Objectives

Patient-specific (PS) implantation surgical technology has been introduced in recent years and a gradual increase in the associated number of surgical cases has been observed. PS technology uses a patient’s own geometry in designing a medical device to provide minimal bone resection with improvement in the prosthetic bone coverage. However, whether PS unicompartmental knee arthroplasty (UKA) provides a better biomechanical effect than standard off-the-shelf prostheses for UKA has not yet been determined, and still remains controversial in both biomechanical and clinical fields. Therefore, the aim of this study was to compare the biomechanical effect between PS and standard off-the-shelf prostheses for UKA.

Methods

The contact stresses on the polyethylene (PE) insert, articular cartilage and lateral meniscus were evaluated in PS and standard off-the-shelf prostheses for UKA using a validated finite element model. Gait cycle loading was applied to evaluate the biomechanical effect in the PS and standard UKAs.


Bone & Joint Research
Vol. 2, Issue 1 | Pages 1 - 8
1 Jan 2013
Costa AJ Lustig S Scholes CJ Balestro J Fatima M Parker DA

Objectives

There remains a lack of data on the reliability of methods to estimate tibial coverage achieved during total knee replacement. In order to address this gap, the intra- and interobserver reliability of a three-dimensional (3D) digital templating method was assessed with one symmetric and one asymmetric prosthesis design.

Methods

A total of 120 template procedures were performed according to specific rotational and over-hang criteria by three observers at time zero and again two weeks later. Total and sub-region coverage were calculated and the reliability of the templating and measurement method was evaluated.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 638 - 641
1 May 2012
Ha C Na S

We aimed to obtain anthropometric data on Korean knees and to compare these with data on commonly available total knee arthroplasties (TKAs). The dimensions of the femora and tibiae of 1168 knees were measured intra-operatively. The femoral components were found to show a tendency toward mediolateral (ML) under-coverage in small femurs and ML overhang in the large femurs. The ML under-coverage was most prominent for the small prostheses. The ML/anteroposterior (ML/AP) ratio of Korean tibiae was greater than that of tibial components.

This study shows that, for different reasons, current TKAs do not provide a reasonable fit for small or large Korean knees, and that the ‘gender-specific’ and ‘stature-specific’ components help for large Korean femurs but offer less satisfactory fits for small femurs. Specific modifications of prostheses are needed for Asian knees.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 333 - 336
1 Mar 2005
Bae DK Yoon KH Kim HS Song SJ

Between July 1986 and August 1996, we performed 32 total knee arthroplasties (TKA) on 32 patients with partially or completely ankylosed knees secondary to infection. Their mean age at surgery was 40 years (20 to 63) and the mean follow-up was ten years (5 to 13). The mean post-operative range of movement was 75.3° (30 to 115) in those with complete and 98.7° (60 to 130) in those with partial ankylosis. The mean Hospital for Special Surgery knee score increased from 57 to 86 points post-operatively. There were complications in four knees (12.5%), which included superficial infection (one), deep infection (one), supracondylar femoral fracture (one) and transient palsy of the common peroneal nerve (one). Although TKA in the ankylosed knee is technically demanding and has a considerable rate of complications, reasonable restoration of function can be obtained by careful selection of patients, meticulous surgical technique, and aggressive rehabilitation.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 638 - 640
1 Jul 1997
Heim M Wershavski M Zwas S Siev-Ner I Nadvorna H Azaria M

The use of silicone inner sockets, with or without the incorporation of shuttle locks, has greatly improved the function of artificial limbs. They cushion and protect the stump and provide a means for prosthetic suspension, allowing more comfortable use, especially in patients with ischaemic stumps. They also allow greater movement at the proximal joint.