Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 783 - 788
1 Jun 2014
Kanakaris N Gudipati S Tosounidis T Harwood P Britten S Giannoudis PV

Intramedullary infection in long bones represents a complex clinical challenge, with an increasing incidence due to the increasing use of intramedullary fixation. We report a prospective case series using an intramedullary reaming device, the Reamer–Irrigator–Aspirator (RIA) system, in association with antibiotic cement rods for the treatment of lower limb long bone infections. A total of 24 such patients, 16 men and eight women, with a mean age of 44.5 years (17 to 75), 14 with femoral and 10 with tibial infection, were treated in a staged manner over a period of 2.5 years in a single referral centre. Of these, 21 patients had had previous surgery, usually for fixation of a fracture (seven had sustained an open fracture originally and one had undergone fasciotomies). According to the Cierny–Mader classification system, 18 patients were classified as type 1A, four as 3A (discharging sinus tract), one as type 4A and one as type 1B. Staphylococcus species were isolated in 20 patients (83.3%). Local antibiotic delivery was used in the form of impregnated cement rods in 23 patients. These were removed at a mean of 2.6 months (1 to 5). Pathogen-specific antibiotics were administered systemically for a mean of six weeks (3 to 18). At a mean follow-up of 21 months (8 to 36), 23 patients (96%) had no evidence of recurrent infection. One underwent a planned trans-tibial amputation two weeks post-operatively due to peripheral vascular disease and chronic recalcitrant osteomyelitis of the tibia and foot. The combination of RIA reaming, the administration of systemic pathogen-specific antibiotics and local delivery using impregnated cement rods proved to be a safe and efficient form of treatment in these patients.

Cite this article: Bone Joint J 2014; 96-B:783–8.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1667 - 1672
1 Dec 2013
Oh C Apivatthakakul T Oh J Kim J Lee H Kyung H Baek S Jung G

Although gradual bone transport may permit the restoration of large-diameter bones, complications are common owing to the long duration of external fixation. In order to reduce such complications, a new technique of bone transport involving the use of an external fixator and a locking plate was devised for segmental tibial bone defects.

A total of ten patients (nine men, one woman) with a mean age at operation of 40.4 years (16 to 64) underwent distraction osteogenesis with a locking plate to treat previously infected post-traumatic segmental tibial defects. The locking plate was fixed percutaneously to bridge proximal and distal segments, and was followed by external fixation. After docking, percutaneous screws were fixed at the transported segment through plate holes. At the same time, bone grafting was performed at the docking site with the external fixator removed.

The mean defect size was 5.9 cm (3.8 to 9.3) and mean external fixation index was 13.4 days/cm (11.8 to 19.5). In all cases, primary union of the docking site and distraction callus was achieved, with an excellent bony result. There was no recurrence of deep infection or osteomyelitis, and with the exception of one patient with a pre-existing peroneal nerve injury, all achieved an excellent or good functional result.

With short external fixation times and low complication rates, bone transport with a locking plate could be recommended for patients with segmental tibial defects.

Cite this article: Bone Joint J 2013;95-B:1667–72.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 75 - 79
1 Jan 2012
Herscovici, Jr D Scaduto JM

The use of autograft bone is the best option when undertaking a procedure that requires bone graft because it is osteogenic, osteoconductive and osseo-inductive. Pain, morbidity and complications associated with harvesting iliac or non-iliac sites occur in between 6% and 30% of cases. An alternative source of graft with possibly a lower morbidity is the intramedullary canal. In this study, 28 patients undergoing 30 arthrodesis procedures on the hindfoot had a mean of 48 cm. 3 . (43 to 50) of bone harvested locally from the hindfoot or the tibial shaft by antegrade or retrograde reaming. No patient sustained a fracture of the calcaneum, talus or tibia. There was no morbidity except for one complication when the reamer breached the medial tibial cortex. This healed uneventfully. . This method of using the reamer–irrigator–aspirator system is an extension of the standard technique of intramedullary reaming of the lower limb: it produces good-quality bone graft with viable growth factors consistent with that of the iliac crest, and donor site morbidity is low. This is an efficient method of obtaining autologous bone for use in arthrodesis of the ankle or hindfoot


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 747 - 750
1 Jun 2006
Schwarz RJ Macdonald MRC van der Pas M

We describe the results of arthrodesis for the treatment of recurrent acute neuropathic bone disease in 24 feet and of chronic disease with deformity in 91 feet, undertaken between January 1984 and December 2003. All were due to leprosy.

Correction of the deformity was achieved in 80 of 106 feet (76%) and fusion in 97 of 110 feet (88%). In the 24 feet in which recurrent neuropathic bone disease was the reason for surgery, 17 (71%) obtained stability while in seven (29%) symptoms recurred postoperatively. Complications were experienced following 58 of the 110 operations (53%). In patients presenting primarily with deformity with a minimum follow-up of two years (79 feet), there was a reduced frequency of ulceration in 40 (51%). Normal footwear could be worn by 32 patients (40%) after surgery, while 40 (51%) required a moulded insole. Arthrodesis of the ankle in the neuropathic foot due to leprosy has a good overall rate of success although the rate of complications is high.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 343 - 347
1 Mar 2005
Winson IG Robinson DE Allen PE

We reviewed 116 patients who underwent 118 arthroscopic ankle arthrodeses. The mean age at operation was 57 years, 2 months (20 to 86 years). The indication for operation was post-traumatic osteoarthritis in 67, primary osteoarthritis in 36, inflammatory arthropathy in 13 and avascular necrosis in two. The mean follow-up was 65 months (18 to 144). Nine patients (10 ankles) died before final review and three were lost to follow-up, leaving 104 patients (105 ankles) who were assessed by a standard telephone interview. The pre-operative talocrural deformity was between 22° valgus and 28° varus, 94 cases were within 10° varus/valgus. The mean time to union was 12 weeks (6 to 20). Nonunion occurred in nine cases (7.6%). Other complications included 22 cases requiring removal of a screw for prominence, three superficial infections, two deep vein thromboses/pulmonary emboli, one revision of fixation, one stress fracture and one deep infection. Six patients had a subtalar fusion at a mean of 48 months after ankle fusion. There were 48 patients with excellent, 35 with good, 10 with fair and 11 with poor clinical results.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 175 - 178
1 Feb 2005
Rosenfeld PF Budgen SA Saxby TS

Our aim was to evaluate the results of triple arthrodesis, performed without the use of supplementary bone graft. We carried out a retrospective review of 100 consecutive triple arthrodeses. All the operations had been performed by the senior author (TSS) using a standard technique. Only local bone graft from the excised joint surfaces had been used, thereby avoiding complications at the donor site.

The mean age of the patients at surgery was 58 years (18 to 84). The mean time to union was 5.1 months (3 to 17). There were 75 good, 20 fair and five poor results. There were four cases of nonunion.

Our study has shown that comparable rates of union are achieved without the need for supplementary bone graft from the iliac crest or other donor site.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 179 - 183
1 Feb 2005
Whittaker J Smith G Makwana N Roberts S Harrison PE Laing P Richardson JB

Autologous chondrocyte implantation (ACI) has been used most commonly as a treatment for cartilage defects in the knee and there are few studies of its use in other joints. We describe ten patients with an osteochondral lesion of the talus who underwent ACI using cartilage taken from the knee and were prospectively reviewed with a mean follow-up of 23 months. In nine patients the satisfaction score was ‘pleased’ or ‘extremely pleased’, which was sustained at four years. The mean Mazur ankle score increased by 23 points at a mean follow-up of 23 months. The Lysholm knee score returned to the pre-operative level at one year in three patients, with the remaining seven showing a reduction of 15% at 12 months, suggesting donor-site morbidity. Nine patients underwent arthroscopic examination at one year and all were shown to have filled defects and stable cartilage. Biopsies taken from graft sites showed mostly fibrocartilage with some hyaline cartilage. The short-term results of ACI for osteochondral lesions of the talus are good despite some morbidity at the donor site


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1013 - 1015
1 Sep 2004
Kim JS Baek GH Chung MS Yoon PW

We performed nine metatarsal and three proximal phalangeal lengthenings in five patients with congenital brachymetatarsia of the first and one or two other metatarsal bones, by a one-stage combined shortening and lengthening procedure using intercalcary autogenous bone grafts from adjacent shortened metatarsal bones. Instead of the isolated lengthening of the first and the other metatarsal bones, we shortened the adjacent normal metatarsal and used the excised bone to lengthen the short toes, except for the great toe, to restore the normal parabola. One skin incision was used. All the operations were performed bilaterally and the patients were followed up for a mean period of 69.5 months (29 to 107). They all regained a nearly normal parabola and were satisfied with the cosmetic results. Our technique is straightforward and produces good cosmetic results. Satisfactory, bony union is achieved, morbidity is low, and no additional surgery is required for the removal of metal implants