Bone & Joint Research
Vol. 8, Issue 3 | Pages 118 - 125
1 Mar 2019
Doi N Izaki T Miyake S Shibata T Ishimatsu T Shibata Y Yamamoto T

Objectives

Indocyanine green (ICG) fluorescence angiography is an emerging technique that can provide detailed anatomical information during surgery. The purpose of this study is to determine whether ICG fluorescence angiography can be used to evaluate the blood flow of the rotator cuff tendon in the clinical setting.

Methods

Twenty-six patients were evaluated from October 2016 to December 2017. The participants were categorized into three groups based on their diagnoses: the rotator cuff tear group; normal rotator cuff group; and adhesive capsulitis group. After establishing a posterior standard viewing portal, intravenous administration of ICG at 0.2 mg/kg body weight was performed, and fluorescence images were recorded. The time from injection of the drug to the beginning of enhancement of the observed area was measured. The hypovascular area in the rotator cuff was evaluated, and the ratio of the hypovascular area to the anterolateral area of the rotator cuff tendon was calculated (hypovascular area ratio).


Bone & Joint Research
Vol. 5, Issue 10 | Pages 470 - 480
1 Oct 2016
Sabharwal S Patel NK Griffiths D Athanasiou T Gupte CM Reilly P

Objectives

The objective of this study was to perform a meta-analysis of all randomised controlled trials (RCTs) comparing surgical and non-surgical management of fractures of the proximal humerus, and to determine whether further analyses based on complexity of fracture, or the type of surgical intervention, produced disparate findings on patient outcomes.

Methods

A systematic review of the literature was performed identifying all RCTs that compared surgical and non-surgical management of fractures of the proximal humerus. Meta-analysis of clinical outcomes was performed where possible. Subgroup analysis based on the type of fracture, and a sensitivity analysis based on the type of surgical intervention, were also performed.


Bone & Joint Research
Vol. 2, Issue 7 | Pages 132 - 139
1 Jul 2013
Ketola S Lehtinen J Rousi T Nissinen M Huhtala H Konttinen YT Arnala I

Objectives

To report the five-year results of a randomised controlled trial examining the effectiveness of arthroscopic acromioplasty in the treatment of stage II shoulder impingement syndrome.

Methods

A total of 140 patients were randomly divided into two groups: 1) supervised exercise programme (n = 70, exercise group); and 2) arthroscopic acromioplasty followed by a similar exercise programme (n = 70, combined treatment group).


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 809 - 814
1 Jun 2013
Park HY Yoon JO Jeon IH Chung HW Kim JS

This study was performed to determine whether pure cancellous bone graft and Kirschner (K-) wire fixation were sufficient to achieve bony union and restore alignment in scaphoid nonunion. A total of 65 patients who underwent cancellous bone graft and K-wire fixation were included in this study. The series included 61 men and four women with a mean age of 34 years (15 to 72) and mean delay to surgery of 28.7 months (3 to 240). The patients were divided into an unstable group (A) and stable group (B) depending on the pre-operative radiographs. Unstable nonunion was defined as a lateral intrascaphoid angle > 45°, or a radiolunate angle > 10°. There were 34 cases in group A and 31 cases in group B. Bony union was achieved in 30 patients (88.2%) in group A, and in 26 (83.9%) in group B (p = 0.439). Comparison of the post-operative radiographs between the two groups showed no significant differences in lateral intrascaphoid angle (p = 0.657) and scaphoid length (p = 0.670) and height (p = 0.193). The radiolunate angle was significantly different (p = 0.020) but the mean value in both groups was < 10°. Comparison of the dorsiflexion and palmar flexion of movement of the wrist and the mean Mayo wrist score at the final clinical visit in each group showed no significant difference (p = 0.190, p = 0.587 and p = 0.265, respectively). Cancellous bone graft and K-wire fixation were effective in the treatment of stable and unstable scaphoid nonunion.

Cite this article: Bone Joint J 2013;95-B:809–14.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 721 - 731
1 Jun 2013
Sewell MD Al-Hadithy N Le Leu A Lambert SM

The sternoclavicular joint (SCJ) is a pivotal articulation in the linked system of the upper limb girdle, providing load-bearing in compression while resisting displacement in tension or distraction at the manubrium sterni. The SCJ and acromioclavicular joint (ACJ) both have a small surface area of contact protected by an intra-articular fibrocartilaginous disc and are supported by strong extrinsic and intrinsic capsular ligaments. The function of load-sharing in the upper limb by bulky periscapular and thoracobrachial muscles is extremely important to the longevity of both joints. Ligamentous and capsular laxity changes with age, exposing both joints to greater strain, which may explain the rising incidence of arthritis in both with age. The incidence of arthritis in the SCJ is less than that in the ACJ, suggesting that the extrinsic ligaments of the SCJ provide greater stability than the coracoclavicular ligaments of the ACJ.

Instability of the SCJ is rare and can be difficult to distinguish from medial clavicular physeal or metaphyseal fracture-separation: cross-sectional imaging is often required. The distinction is important because the treatment options and outcomes of treatment are dissimilar, whereas the treatment and outcomes of ACJ separation and fracture of the lateral clavicle can be similar. Proper recognition and treatment of traumatic instability is vital as these injuries may be life-threatening. Instability of the SCJ does not always require surgical intervention. An accurate diagnosis is required before surgery can be considered, and we recommend the use of the Stanmore instability triangle. Most poor outcomes result from a failure to recognise the underlying pathology.

There is a natural reluctance for orthopaedic surgeons to operate in this area owing to unfamiliarity with, and the close proximity of, the related vascular structures, but the interposed sternohyoid and sternothyroid muscles are rarely injured and provide a clear boundary to the medial retroclavicular space, as well as an anatomical barrier to unsafe intervention.

This review presents current concepts of instability of the SCJ, describes the relevant surgical anatomy, provides a framework for diagnosis and management, including physiotherapy, and discusses the technical challenges of operative intervention.

Cite this article: Bone Joint J 2013;95-B:721–31.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1534 - 1539
1 Nov 2012
Karataglis D Papadopoulos P Boutsiadis A Fotiadou A Ditsios K Hatzokos I Christodoulou A

This study evaluates the position of the long head of biceps tendon using ultrasound following simple tenotomy, in patients with arthroscopically repaired rotator cuff tears.

In total, 52 patients with a mean age of 60.7 years (45 to 75) underwent arthroscopic repair of the rotator cuff and simple tenotomy of the long head of biceps tendon. At two years post-operatively, ultrasound revealed that the tendon was inside the bicipital groove in 43 patients (82.7%) and outside in nine (17.3%); in six of these it was lying just outside the groove and in the remaining three (5.8%) it was in a remote position with a positive Popeye Sign. A dynamic ultrasound scan revealed that the tenotomised tendons had adhered to the surrounding tissues (autotenodesis).The initial condition of the tendon influenced its final position (p < 0.0005). The presence of a Popeye sign was statistically influenced by the pre-operative co-existence of supraspinatus and subscapularis tears (p < 0.0001).

It appears that the natural history of the tenotomised long head of biceps tendon is to tenodese itself inside or just outside the bicipital groove, while its pre-operative condition and coexistent subscapularis tears play a significant role in the occurrence of a Popeye sign.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1305 - 1312
1 Oct 2012
Adams J Ryall C Pandyan A Metcalf C Stokes M Bradley S Warwick DJ

We systematically reviewed all the evidence published in the English language on proximal interphalangeal joint (PIPJ) replacement, to determine its effectiveness on the function of the hand and the associated post-operative complications.

Original studies were selected if they reported clinical outcome with a minimum of one year’s follow-up. Quality was assessed using the Cowley systematic review criteria modified for finger-joint replacements. Of 319 articles identified, only five were adequately reported according to our quality criteria; there were no randomised controlled trials. PIPJ replacements had a substantial effect size on hand pain of -23.2 (95% confidence interval (CI) -27.3 to -19.1) and grip strength 1.2 (95% CI -10.7 to 13.1), and a small effect on range of movement 0.2 (95% CI -0.4 to 0.8). A dorsal approach was most successful. Post-operative loosening occurred in 10% (95% CI 3 to 30) of ceramic and 12.5% (95% CI 7 to 21) of pyrocarbon replacements. Post-operative complications occurred in 27.8% (95% CI 20 to 37).

We conclude that the effectiveness of PIPJ replacement has not been established. Small observational case studies and short-term follow-up, together with insufficient reporting of patient data, functional outcomes and complications, limit the value of current evidence.

We recommend that a defined core set of patients, surgical and outcome data for this intervention be routinely and systematically collected within the framework of a joint registry.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 353 - 358
1 Mar 2012
Kim SM Park MJ Kang HJ Choi YL Lee JJ

We investigated the clinical response to arthroscopic synovectomy in patients with undifferentiated chronic monoarthritis (UCMA) of the wrist. Arthroscopic synovectomy was performed on 20 wrists in 20 patients with UCMA of the wrist who had not responded to non-steroidal anti-inflammatory drugs. The mean duration of symptoms at the time of surgery was 4.3 months (3 to 7) and the mean follow-up was 51.8 months (24 to 94). Inflamed synovium was completely removed from the radiocarpal, midcarpal and distal radioulnar joints using more portals than normal. After surgery, nine patients had early remission of synovitis and 11 with uncontrolled synovitis received antirheumatic medication. Overall, there was significant improvement in terms of pain relief, range of movement and Mayo score. Radiological deterioration was seen in five patients who were diagnosed as having rheumatoid arthritis during the follow-up period. Lymphoid follicles and severe lymphocyte infiltration were seen more often in synovial biopsies from patients with uncontrolled synovitis.

These results suggest that arthroscopic synovectomy provides pain relief and functional improvement, and allows rapid resolution of synovitis in about half of patients with UCMA of the wrist.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 80 - 85
1 Jan 2012
Malone AA Sanchez JS Adams R Morrey B

We report the effectiveness of revision of total elbow replacement by re-cementing. Between 1982 and 2004, 53 elbows in 52 patients were treated with re-cementing of a total elbow replacement into part or all of the existing cement mantle or into the debrided host-bone interface, without the use of structural bone augmentation or a custom prosthesis. The original implant revision was still in situ and functional in 42 of 53 elbows (79%) at a mean of 94.5 months (26 to 266) after surgery. In 31 of these 42 elbows (74%) the Mayo Elbow Performance Score was good or excellent. Overall, of the 53 elbows, 18 (34%) required re-operation, ten (19%) for loosening. A classification system was developed to identify those not suitable for revision by this technique, and using this we have showed that successful re-implantation is statistically correlated to properly addressing the bone deficiency for both the humeral (p = 0.005) and the ulnar (p = 0.039) components.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 504 - 510
1 Apr 2009
Henkus HE de Witte PB Nelissen RGHH Brand R van Arkel ERA

In a prospective randomised study we compared the results of arthroscopic subacromial bursectomy alone with debridement of the subacromial bursa followed by acromioplasty. A total of 57 patients with a mean age of 47 years (31 to 60) suffering from primary subacromial impingement without a rupture of the rotator cuff who had failed previous conservative treatment were entered into the trial. The type of acromion was classified according to Bigliani. Patients were assessed at follow-up using the Constant score, the simple shoulder test and visual analogue scores for pain and functional impairment. One patient was lost to follow-up.

At a mean follow-up of 2.5 years (1 to 5) both bursectomy and acromioplasty gave good clinical results. No statistically significant differences were found between the two treatments. The type of acromion and severity of symptoms had a greater influence on the clinical outcome than the type of treatment. As a result, we believe that primary subacromial impingement syndrome is largely an intrinsic degenerative condition rather than an extrinsic mechanical disorder.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 335 - 341
1 Mar 2007
Albert J Meadeb J Guggenbuhl P Marin F Benkalfate T Thomazeau H Chalès G

In a prospective randomised trial of calcifying tendinitis of the rotator cuff, we compared the efficacy of dual treatment sessions delivering 2500 extracorporeal shock waves at either high- or low-energy, via an electromagnetic generator under fluoroscopic guidance. Patients were eligible for the study if they had more than a three-month history of calcifying tendinitis of the rotator cuff, with calcification measuring 10 mm or more in maximum dimension. The primary outcome measure was the change in the Constant and Murley Score. A total of 80 patients were enrolled (40 in each group), and were re-evaluated at a mean of 110 (41 to 255) days after treatment when the increase in Constant and Murley score was significantly greater (t-test, p = 0.026) in the high-energy treatment group than in the low-energy group. The improvement from the baseline level was significant in the high-energy group, with a mean gain of 12.5 (−20.7 to 47.5) points (p < 0.0001). The improvement was not significant in the low-energy group. Total or subtotal resorption of the calcification occurred in six patients (15%) in the high-energy group and in two patients (5%) in the low-energy group. High-energy shock-wave therapy significantly improves symptoms in refractory calcifying tendinitis of the shoulder after three months of follow-up, but the calcific deposit remains unchanged in size in the majority of patients


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 206 - 209
1 Feb 2007
Houshian S Chikkamuniyappa C Schroeder H

We present the outcome of the treatment of chronic post-traumatic contractures of the proximal interphalangeal joint by gradual distraction correction using an external fixator. A total of 30 consecutive patients with a mean age of 34 years (17 to 54) had distraction for a mean of 16 days (10 to 22). The fixator was removed after a mean of 29 days (16 to 40). Assessment at a mean of 34 months (18 to 54) after completion of treatment showed that the mean active range of movement had significantly increased by 63° (30° to 90°; p < 0.001). The mean active extension gained was 47° (30° to 75°).

Patients aged less than 40 years fared slightly better with a mean gain in active range of movement of 65° (30° to 90°) compared with those aged more than 40 years, who had a mean gain in active range of movement of 55° (30° to 70°) but the difference was not statistically significant (p = 0.148).

The use of joint distraction to correct chronic flexion contracture of the proximal interphalangeal joint is a minimally-invasive and effective method of treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 824 - 828
1 Jun 2005
Charousset C Bellaïche L Duranthon LD Grimberg J

CT arthrography and arthroscopy were used to assess tears of the rotator cuff in 259 shoulders. Tear size was determined in the frontal and sagittal planes according to the classification of the French Arthroscopy Society.

CT arthrography had a sensitivity of 99% and a specificity of 100% for the diagnosis of tears of supraspinatus. For infraspinatus these figures were 97.44% and 99.52%, respectively and, for subscapularis, 64.71% and 98.17%. For lesions of the long head of the biceps, the sensitivity was 45.76% and the specificity was 99.57%.

Our study showed an excellent correlation between CT arthrography and arthroscopy when assessing the extent of a rotator cuff tear. CT arthrography should, therefore, be an indispensable part of pre-operative assessment. It allows determination of whether a tear is reparable (retraction of the tendon and fatty degeneration of the corresponding muscle) and whether this is possible by arthroscopy (degree of tendon retraction and extension to subscapularis).


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 348 - 351
1 Mar 2005
Kreuz PC Remiger A Lahm A Herget G Gächter A

We treated surgically 16 shoulders with an isolated traumatic rupture of the subscapularis tendon over a six-year period. Nine patients had a total and seven a partial tear of the subscapularis tendon. Repair was undertaken through a small deltopectoral groove approach. The mean Constant score improved in total tears from 38.7 to 89.3 points (p = 0.003) and in partial tears from 50.7 to 87.9 points (p = 0.008). The total tears were significantly more improved by surgery than the partial tears (p = 0.001). The delay between trauma and surgery was inversely proportional to the improvement in the Constant score suggesting that early diagnosis and surgical repair improves outcome.