Advertisement for orthosearch.org.uk
Results 1 - 50 of 1508
Results per page:

Aims

For rare cases when a tumour infiltrates into the hip joint, extra-articular resection is required to obtain a safe margin. Endoprosthetic reconstruction following tumour resection can effectively ensure local control and improve postoperative function. However, maximizing bone preservation without compromising surgical margin remains a challenge for surgeons due to the complexity of the procedure. The purpose of the current study was to report clinical outcomes of patients who underwent extra-articular resection of the hip joint using a custom-made osteotomy guide and 3D-printed endoprosthesis.

Methods

We reviewed 15 patients over a five-year period (January 2017 to December 2022) who had undergone extra-articular resection of the hip joint due to malignant tumour using a custom-made osteotomy guide and 3D-printed endoprosthesis. Each of the 15 patients had a single lesion, with six originating from the acetabulum side and nine from the proximal femur. All patients had their posterior column preserved according to the surgical plan.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 953 - 961
1 Nov 2024
Mew LE Heaslip V Immins T Ramasamy A Wainwright TW

Aims

The evidence base within trauma and orthopaedics has traditionally favoured quantitative research methodologies. Qualitative research can provide unique insights which illuminate patient experiences and perceptions of care. Qualitative methods reveal the subjective narratives of patients that are not captured by quantitative data, providing a more comprehensive understanding of patient-centred care. The aim of this study is to quantify the level of qualitative research within the orthopaedic literature.

Methods

A bibliometric search of journals’ online archives and multiple databases was undertaken in March 2024, to identify articles using qualitative research methods in the top 12 trauma and orthopaedic journals based on the 2023 impact factor and SCImago rating. The bibliometric search was conducted and reported in accordance with the preliminary guideline for reporting bibliometric reviews of the biomedical literature (BIBLIO).


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1199 - 1202
1 Nov 2024
Watts AC Tennent TD Haddad FS


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1223 - 1230
1 Nov 2024
Dugdale EM Uvodich ME Pagnano MW Berry DJ Abdel MP Bedard NA

Aims

The prevalence of obesity is increasing substantially around the world. Elevated BMI increases the risk of complications following total hip arthroplasty (THA). We sought to evaluate trends in BMI and complication rates of obese patients undergoing primary THA over the last 30 years.

Methods

Through our institutional total joint registry, we identified 15,455 primary THAs performed for osteoarthritis from 1990 to 2019. Patients were categorized according to the World Health Organization (WHO) obesity classification and groups were trended over time. Cox proportional hazards regression analysis controlling for confounders was used to investigate the association between year of surgery and two-year risk of any reoperation, any revision, dislocation, periprosthetic joint infection (PJI), venous thromboembolism (VTE), and periprosthetic fracture. Regression was stratified by three separate groups: non-obese; WHO Class I and Class II (BMI 30 to 39 kg/m2); and WHO Class III patients (BMI ≥ 40 kg/m2).


Bone & Joint Open
Vol. 5, Issue 10 | Pages 904 - 910
18 Oct 2024
Bergman EM Mulligan EP Patel RM Wells J

Aims

The Single Assessment Numerical Evalution (SANE) score is a pragmatic alternative to longer patient-reported outcome measures (PROMs). The purpose of this study was to investigate the concurrent validity of the SANE and hip-specific PROMs in a generalized population of patients with hip pain at a single timepoint upon initial visit with an orthopaedic surgeon who is a hip preservation specialist. We hypothesized that SANE would have a strong correlation with the 12-question International Hip Outcome Tool (iHOT)-12, the Hip Outcome Score (HOS), and the Hip disability and Osteoarthritis Outcome Score (HOOS), providing evidence for concurrent validity of the SANE and hip-specific outcome measures in patients with hip pain.

Methods

This study was a cross-sectional retrospective database analysis at a single timepoint. Data were collected from 2,782 patients at initial evaluation with a hip preservation specialist using the iHOT-12, HOS, HOOS, and SANE. Outcome scores were retrospectively analyzed using Pearson correlation coefficients.


Bone & Joint Open
Vol. 5, Issue 10 | Pages 837 - 843
7 Oct 2024
Zalikha AK Waheed MA Twal C Keeley J El-Othmani MM Hajj Hussein I

Aims

This study aims to evaluate the impact of metabolic syndrome in the setting of obesity on in-hospital outcomes and resource use after total joint replacement (TJR).

Methods

A retrospective analysis was conducted using the National Inpatient Sample from 2006 to the third quarter of 2015. Discharges representing patients aged 40 years and older with obesity (BMI > 30 kg/m2) who underwent primary TJR were included. Patients were stratified into two groups with and without metabolic syndrome. The inverse probability of treatment weighting (IPTW) method was used to balance covariates.


Bone & Joint 360
Vol. 13, Issue 5 | Pages 24 - 26
1 Oct 2024

The October 2024 Knee Roundup360 looks at: Managing the unexpected: treatment of intraoperative medial collateral ligament injuries; Identifying subgroups of patients that may benefit from robotic arm-assisted total knee arthroplasty: secondary analysis of data from a randomized controlled trial; Cost-effectiveness of enoxaparin versus aspirin in the prevention of venous thromboembolism after total hip or knee arthroplasty: an analysis from the CRISTAL cluster-randomized trial; Cartilage regeneration and long-term survival in medial knee osteoarthritis patients treated with high tibial osteotomy and osteochondral autologous transfer system; Treatment of chronic and complex meniscal tears with arthroscopic meniscus repair augmented with collagen matrix wrapping: failure rate and functional outcomes; Long-term outcomes of multiligament knee injuries in American football players.


Bone & Joint 360
Vol. 13, Issue 5 | Pages 47 - 49
1 Oct 2024

The October 2024 Research Roundup360 looks at: Fracture risk among stroke survivors according to post-stroke disability status and stroke type; Noise-induced hearing loss: should surgeons be wearing ear protection during primary total joint replacement?; Intravenous dexamethasone in hip arthroscopy can enhance recovery; Patient-reported outcomes following periprosthetic joint infection of the hip and knee: a longitudinal, prospective observational study; When should surgery take place after weight loss?; Which type of surgery is the hardest physically and mentally?


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1074 - 1083
1 Oct 2024
Sørensen RR Timm S Rasmussen LE Brasen CL Varnum C

Aims

The influence of metabolic syndrome (MetS) on the outcome after hip and knee arthroplasty is debated. We aimed to investigate the change in patient-reported outcome measure (PROM) scores after hip and knee arthroplasty, comparing patients with and without MetS.

Methods

From 1 May 2017 to 30 November 2019, a prospective cohort of 2,586 patients undergoing elective unilateral hip and knee arthroplasty was established in Denmark. Data from national registries and a local database were used to determine the presence of MetS. Patients’ scores on Oxford Hip Score (OHS) or Oxford Knee Score (OKS), EuroQol five-dimension five-level questionnaire (EQ-5D-5L), University of California, Los Angeles (UCLA) Activity Scale, and Forgotten Joint Score (FJS) at baseline, three, 12, and 24 months after surgery were collected. Primary outcome was the difference between groups from baseline to 12 months in OHS and OKS. Secondary outcomes were scores of OHS and OKS at three and 24 months and EQ-5D-5L, UCLA Activity Scale, and FJS at three, 12, and 24 months after surgery. Generalized linear mixed model was applied, adjusting for age, sex, Charlson Comorbidity Index, and smoking to present marginal mean and associated 95% CIs.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1050 - 1058
1 Oct 2024
Holleyman RJ Jameson SS Meek RMD Khanduja V Reed MR Judge A Board TN

Aims. This study evaluates the association between consultant and hospital volume and the risk of re-revision and 90-day mortality following first-time revision of primary hip arthroplasty for aseptic loosening. Methods. We conducted a cohort study of first-time, single-stage revision hip arthroplasties (RHAs) performed for aseptic loosening and recorded in the National Joint Registry (NJR) data for England, Wales, Northern Ireland, and the Isle of Man between 2003 and 2019. Patient identifiers were used to link records to national mortality data, and to NJR data to identify subsequent re-revision procedures. Multivariable Cox proportional hazard models with restricted cubic splines were used to define associations between volume and outcome. Results. Among 12,961 RHAs there were 513 re-revisions within two years, and 95 deaths within 90 days of surgery. The risk of re-revision was highest for a consultant’s first RHA (hazard ratio (HR) 1.56 (95% CI 1.15 to 2.12)) and remained significantly elevated for their first 24 cases (HR 1.26 (95% CI 1.00 to 1.58)). Annual consultant volumes of five/year were associated with an almost 30% greater risk of re-revision (HR 1.28 (95% CI 1.00 to 1.64)) and 80% greater risk of 90-day mortality (HR 1.81 (95% CI 1.02 to 3.21)) compared to volumes of 20/year. RHAs performed at hospitals which had cumulatively undertaken fewer than 167 RHAs were at up to 70% greater risk of re-revision (HR 1.70 (95% CI 1.12 to 2.59)), and those having undertaken fewer than 307 RHAs were at up to three times greater risk of 90-day mortality (HR 3.05 (95% CI 1.19 to 7.82)). Conclusion. This study found a significantly higher risk of re-revision and early postoperative mortality following first-time single-stage RHA for aseptic loosening when performed by lower-volume consultants and at lower-volume institutions, supporting the move towards the centralization of such cases towards higher-volume units and surgeons. Cite this article: Bone Joint J 2024;106-B(10):1050–1058


Bone & Joint 360
Vol. 13, Issue 5 | Pages 21 - 23
1 Oct 2024

The October 2024 Hip & Pelvis Roundup360 looks at: Does the primary surgical approach matter when choosing the approach for revision total hip arthroplasty?; Time to achieve the minimal clinically important difference in primary total hip arthroplasty: comparison of anterior and posterior surgical approaches; To scope or not to scope: arthroscopy as an adjunct to PAO does not provide better clinical outcomes at one year than PAO alone; Re-exploring horizons in hip resurfacing: two-year results of a ceramic-on-ceramic hip resurfacing; Association between tranexamic acid and decreased periprosthetic joint infection risk in patients undergoing total hip and knee arthroplasty; Octogenarians fare well: in revision for infection age is not a bar.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 924 - 934
1 Sep 2024
Cheok T Beveridge A Berman M Coia M Campbell A Tse TTS Doornberg JN Jaarsma RL

Aims

We investigated the efficacy and safety profile of commonly used venous thromboembolism (VTE) prophylaxis agents following hip and knee arthroplasty.

Methods

A systematic search of PubMed, Embase, Cochrane Library, Web of Science, and OrthoSearch was performed. Prophylaxis agents investigated were aspirin (< 325 mg and ≥ 325 mg daily), enoxaparin, dalteparin, fondaparinux, unfractionated heparin, warfarin, rivaroxaban, apixaban, and dabigatran. The primary efficacy outcome of interest was the risk of VTE, whereas the primary safety outcomes of interest were the risk of major bleeding events (MBE) and wound complications (WC). VTE was defined as the confirmed diagnosis of any deep vein thrombosis and/or pulmonary embolism. Network meta-analysis combining direct and indirect evidence was performed. Cluster rank analysis using the surface under cumulative ranking (SUCRA) was applied to compare each intervention group, weighing safety and efficacy outcomes.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 935 - 941
1 Sep 2024
Ailaney N Guirguis PG Ginnetti JG Balkissoon R Myers TG Ramirez G Thirukumaran CP Ricciardi BF

Aims

The purpose of this study was to determine the association between prior sleeve gastrectomy in patients undergoing primary total hip and knee arthroplasty, and 90-day complications, incidence of revision arthroplasty, and patient-reported outcome scores at final follow-up.

Methods

This is a retrospective, single-centre analysis. Patients undergoing primary hip or knee arthroplasty with a prior sleeve gastrectomy were eligible for inclusion (n = 80 patients). A morbidly obese control group was established from the same institutional registry using a 1:2 match, for cases:controls with arthroplasty based on propensity score using age, sex, pre-sleeve gastrectomy BMI, Current Procedural Terminology code to identify anatomical location, and presurgical haemoglobin A1C. Outcomes included 90-day complications, incidence of revision arthroplasty, and patient-reported outcome scores at final follow-up. Multivariable logistic regressions evaluated associations of underlying preoperative demographic and treatment characteristics with outcomes.


Bone & Joint Open
Vol. 5, Issue 8 | Pages 715 - 720
23 Aug 2024
Shen TS Cheng R Chiu Y McLawhorn AS Figgie MP Westrich GH

Aims

Implant waste during total hip arthroplasty (THA) represents a significant cost to the USA healthcare system. While studies have explored methods to improve THA cost-effectiveness, the literature comparing the proportions of implant waste by intraoperative technology used during THA is limited. The aims of this study were to: 1) examine whether the use of enabling technologies during THA results in a smaller proportion of wasted implants compared to navigation-guided and conventional manual THA; 2) determine the proportion of wasted implants by implant type; and 3) examine the effects of surgeon experience on rates of implant waste by technology used.

Methods

We identified 104,420 implants either implanted or wasted during 18,329 primary THAs performed on 16,724 patients between January 2018 and June 2022 at our institution. THAs were separated by technology used: robotic-assisted (n = 4,171), imageless navigation (n = 6,887), and manual (n = 7,721). The primary outcome of interest was the rate of implant waste during primary THA.


Bone & Joint Open
Vol. 5, Issue 8 | Pages 671 - 680
14 Aug 2024
Fontalis A Zhao B Putzeys P Mancino F Zhang S Vanspauwen T Glod F Plastow R Mazomenos E Haddad FS

Aims

Precise implant positioning, tailored to individual spinopelvic biomechanics and phenotype, is paramount for stability in total hip arthroplasty (THA). Despite a few studies on instability prediction, there is a notable gap in research utilizing artificial intelligence (AI). The objective of our pilot study was to evaluate the feasibility of developing an AI algorithm tailored to individual spinopelvic mechanics and patient phenotype for predicting impingement.

Methods

This international, multicentre prospective cohort study across two centres encompassed 157 adults undergoing primary robotic arm-assisted THA. Impingement during specific flexion and extension stances was identified using the virtual range of motion (ROM) tool of the robotic software. The primary AI model, the Light Gradient-Boosting Machine (LGBM), used tabular data to predict impingement presence, direction (flexion or extension), and type. A secondary model integrating tabular data with plain anteroposterior pelvis radiographs was evaluated to assess for any potential enhancement in prediction accuracy.


Bone & Joint Open
Vol. 5, Issue 8 | Pages 637 - 643
6 Aug 2024
Abelleyra Lastoria DA Casey L Beni R Papanastasiou AV Kamyab AA Devetzis K Scott CEH Hing CB

Aims

Our primary aim was to establish the proportion of female orthopaedic consultants who perform arthroplasty via cases submitted to the National Joint Registry (NJR), which covers England, Wales, Northern Ireland, the Isle of Man, and Guernsey. Secondary aims included comparing time since specialist registration, private practice participation, and number of hospitals worked in between male and female surgeons.

Methods

Publicly available data from the NJR was extracted on the types of arthroplasty performed by each surgeon, and the number of procedures of each type undertaken. Each surgeon was cross-referenced with the General Medical Council (GMC) website, using GMC number to extract surgeon demographic data. These included sex, region of practice, and dates of full and specialist registration.


Bone & Joint 360
Vol. 13, Issue 4 | Pages 26 - 29
2 Aug 2024

The August 2024 Shoulder & Elbow Roundup360 looks at: Comparing augmented and nonaugmented locking-plate fixation for proximal humeral fractures in the elderly; Elevated five-year mortality following shoulder arthroplasty for fracture; Total intravenous anaesthesia with propofol reduces discharge times compared with inhaled general anaesthesia in shoulder arthroscopy: a randomized controlled trial; The influence of obesity on outcomes following arthroscopic rotator cuff repair; Humeral component version has no effect on outcomes following reverse total shoulder arthroplasty: a prospective, double-blinded, randomized controlled trial; What is a meaningful improvement after total shoulder arthroplasty by implant type, preoperative diagnosis, and sex?; The safety of corticosteroid injection prior to shoulder arthroplasty: a systematic review; Mortality and subsequent fractures of patients with olecranon fractures compared to other upper limb osteoporotic fractures.


Bone & Joint 360
Vol. 13, Issue 4 | Pages 13 - 16
2 Aug 2024

The August 2024 Hip & Pelvis Roundup. 360. looks at: Understanding perceived leg length discrepancy post-total hip arthroplasty: the role of pelvic obliquity; Influence of femoral stem design on revision rates in total hip arthroplasty; Outcomes of arthroscopic labral treatment of femoroacetabular impingement in adolescents; Characteristics and quality of online searches for direct anterior versus posterior approach for total hip arthroplasty; Rapid return to braking after anterior and posterior approach total hip arthroplasty; How much protection does a collar provide?; Timing matters: reducing infection risk in total hip arthroplasty with corticosteroid injection intervals; Identifying pain recovery patterns in total hip arthroplasty using PROMIS data


Bone & Joint 360
Vol. 13, Issue 4 | Pages 43 - 45
2 Aug 2024
Evans JT Evans JP Whitehouse MR


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 834 - 841
1 Aug 2024
French JMR Deere K Jones T Pegg DJ Reed MR Whitehouse MR Sayers A

Aims

The COVID-19 pandemic has disrupted the provision of arthroplasty services in England, Wales, and Northern Ireland. This study aimed to quantify the backlog, analyze national trends, and predict time to recovery.

Methods

We performed an analysis of the mandatory prospective national registry of all independent and publicly funded hip, knee, shoulder, elbow, and ankle replacements in England, Wales, and Northern Ireland between January 2019 and December 2022 inclusive, totalling 729,642 operations. The deficit was calculated per year compared to a continuation of 2019 volume. Total deficit of cases between 2020 to 2022 was expressed as a percentage of 2019 volume. Sub-analyses were performed based on procedure type, country, and unit sector.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 775 - 782
1 Aug 2024
Wagner M Schaller L Endstrasser F Vavron P Braito M Schmaranzer E Schmaranzer F Brunner A

Aims

Hip arthroscopy has gained prominence as a primary surgical intervention for symptomatic femoroacetabular impingement (FAI). This study aimed to identify radiological features, and their combinations, that predict the outcome of hip arthroscopy for FAI.

Methods

A prognostic cross-sectional cohort study was conducted involving patients from a single centre who underwent hip arthroscopy between January 2013 and April 2021. Radiological metrics measured on conventional radiographs and magnetic resonance arthrography were systematically assessed. The study analyzed the relationship between these metrics and complication rates, revision rates, and patient-reported outcomes.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 802 - 807
1 Aug 2024
Kennedy JW Sinnerton R Jeyakumar G Kane N Young D Meek RMD

Aims

The number of revision arthroplasties being performed in the elderly is expected to rise, including revision for infection. The primary aim of this study was to measure the treatment success rate for octogenarians undergoing revision total hip arthroplasty (THA) for periprosthetic joint infection (PJI) compared to a younger cohort. Secondary outcomes were complications and mortality.

Methods

Patients undergoing one- or two-stage revision of a primary THA for PJI between January 2008 and January 2021 were identified. Age, sex, BMI, American Society of Anesthesiologists grade, Charlson Comorbidity Index (CCI), McPherson systemic host grade, and causative organism were collated for all patients. PJI was classified as ‘confirmed’, ‘likely’, or ‘unlikely’ according to the 2021 European Bone and Joint Infection Society criteria. Primary outcomes were complications, reoperation, re-revision, and successful treatment of PJI. A total of 37 patients aged 80 years or older and 120 patients aged under 80 years were identified. The octogenarian group had a significantly lower BMI and significantly higher CCI and McPherson systemic host grades compared to the younger cohort.


Bone & Joint Open
Vol. 5, Issue 8 | Pages 621 - 627
1 Aug 2024
Walter N Loew T Hinterberger T Alt V Rupp M

Aims

Fracture-related infections (FRIs) are a devastating complication of fracture management. However, the impact of FRIs on mental health remains understudied. The aim of this study was a longitudinal evaluation of patients’ psychological state, and expectations for recovery comparing patients with recurrent FRI to those with primary FRI.

Methods

A prospective longitudinal study was conducted at a level 1 trauma centre from January 2020 to December 2022. In total, 56 patients treated for FRI were enrolled. The ICD-10 symptom rating (ISR) and an expectation questionnaire were assessed at five timepoints: preoperatively, one month postoperatively, and at three, six, and 12 months.


Bone & Joint Open
Vol. 5, Issue 7 | Pages 543 - 549
3 Jul 2024
Davies AR Sabharwal S Reilly P Sankey RA Griffiths D Archer S

Aims

Shoulder arthroplasty is effective in the management of end-stage glenohumeral joint arthritis. However, it is major surgery and patients must balance multiple factors when considering the procedure. An understanding of patients’ decision-making processes may facilitate greater support of those considering shoulder arthroplasty and inform the outcomes of future research.

Methods

Participants were recruited from waiting lists of three consultant upper limb surgeons across two NHS hospitals. Semi-structured interviews were conducted with 12 participants who were awaiting elective shoulder arthroplasty. Transcribed interviews were analyzed using a grounded theory approach. Systematic coding was performed; initial codes were categorized and further developed into summary narratives through a process of discussion and refinement. Data collection and analyses continued until thematic saturation was reached.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 514 - 523
24 Jun 2024
Fishley W Nandra R Carluke I Partington PF Reed MR Kramer DJ Wilson MJ Hubble MJW Howell JR Whitehouse SL Petheram TG Kassam AM

Aims. In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and formation of pseudotumours, ultimately requiring revision. The size and diametral clearance of anatomical (ADM) and modular (MDM) dual-mobility polyethylene bearings match those of Birmingham hip MoM components. If the acetabular component is satisfactorily positioned, well integrated into the bone, and has no surface damage, this presents the opportunity for revision with exchange of the metal head for ADM/MDM polyethylene bearings without removal of the acetabular component. Methods. Between 2012 and 2020, across two centres, 94 patients underwent revision of Birmingham MoM hip arthroplasties or resurfacings. Mean age was 65.5 years (33 to 87). In 53 patients (56.4%), the acetabular component was retained and dual-mobility bearings were used (DM); in 41 (43.6%) the acetabulum was revised (AR). Patients underwent follow-up of minimum two-years (mean 4.6 (2.1 to 8.5) years). Results. In the DM group, two (3.8%) patients underwent further surgery: one (1.9%) for dislocation and one (1.9%) for infection. In the AR group, four (9.8%) underwent further procedures: two (4.9%) for loosening of the acetabular component and two (4.9%) following dislocations. There were no other dislocations in either group. In the DM group, operating time (68.4 vs 101.5 mins, p < 0.001), postoperative drop in haemoglobin (16.6 vs 27.8 g/L, p < 0.001), and length of stay (1.8 vs 2.4 days, p < 0.001) were significantly lower. There was a significant reduction in serum metal ions postoperatively in both groups (p < 0.001), although there was no difference between groups for this reduction (p = 0.674 (cobalt); p = 0.186 (chromium)). Conclusion. In selected patients with Birmingham MoM hips, where the acetabular component is well-fixed and in a satisfactory position with no surface damage, the metal head can be exchanged for polyethylene ADM/MDM bearings with retention of the acetabular prosthesis. This presents significant benefits, with a shorter procedure and a lower risk of complications. Cite this article: Bone Jt Open 2024;5(6):514–523


Bone & Joint Open
Vol. 5, Issue 6 | Pages 479 - 488
6 Jun 2024
Paksoy A Meller S Schwotzer F Moroder P Trampuz A Imiolczyk J Perka C Hackl M Plachel F Akgün D

Aims. Current diagnostic tools are not always able to effectively identify periprosthetic joint infections (PJIs). Recent studies suggest that circulating microRNAs (miRNAs) undergo changes under pathological conditions such as infection. The aim of this study was to analyze miRNA expression in hip arthroplasty PJI patients. Methods. This was a prospective pilot study, including 24 patients divided into three groups, with eight patients each undergoing revision of their hip arthroplasty due to aseptic reasons, and low- and high-grade PJI, respectively. The number of intraoperative samples and the incidence of positive cultures were recorded for each patient. Additionally, venous blood samples and periarticular tissue samples were collected from each patient to determine miRNA expressions between the groups. MiRNA screening was performed by small RNA-sequencing using the miRNA next generation sequencing (NGS) discovery (miND) pipeline. Results. Overall, several miRNAs in plasma and tissue were identified to be progressively deregulated according to ongoing PJI. When comparing the plasma samples, patients with a high-grade infection showed significantly higher expression levels for hsa-miR-21-3p, hsa-miR-1290, and hsa-miR-4488, and lower expression levels for hsa-miR-130a-3p and hsa-miR-451a compared to the aseptic group. Furthermore, the high-grade group showed a significantly higher regulated expression level of hsa-miR-1260a and lower expression levels for hsa-miR-26a-5p, hsa-miR-26b-5p, hsa-miR-148b-5p, hsa-miR-301a-3p, hsa-miR-451a, and hsa-miR-454-3p compared to the low-grade group. No significant differences were found between the low-grade and aseptic groups. When comparing the tissue samples, the high-grade group showed significantly higher expression levels for 23 different miRNAs and lower expression levels for hsa-miR-2110 and hsa-miR-3200-3p compared to the aseptic group. No significant differences were found in miRNA expression between the high- and low-grade groups, as well as between the low-grade and aseptic groups. Conclusion. With this prospective pilot study, we were able to identify a circulating miRNA signature correlating with high-grade PJI compared to aseptic patients undergoing hip arthroplasty revision. Our data contribute to establishing miRNA signatures as potential novel diagnostic and prognostic biomarkers for PJI. Cite this article: Bone Jt Open 2024;5(6):479–488


Bone & Joint 360
Vol. 13, Issue 3 | Pages 5 - 6
3 Jun 2024
Ollivere B


Bone & Joint 360
Vol. 13, Issue 3 | Pages 18 - 20
3 Jun 2024

The June 2024 Hip & Pelvis Roundup. 360. looks at: Machine learning did not outperform conventional competing risk modelling to predict revision arthroplasty; Unravelling the risks: incidence and reoperation rates for femoral fractures post-total hip arthroplasty; Spinal versus general anaesthesia for hip arthroscopy: a COVID-19 pandemic- and opioid epidemic-driven study; Development and validation of a deep-learning model to predict total hip arthroplasty on radiographs; Ambulatory centres lead in same-day hip and knee arthroplasty success; Exploring the impact of smokeless tobacco on total hip arthroplasty outcomes: a deeper dive into postoperative complications



Bone & Joint 360
Vol. 13, Issue 3 | Pages 8 - 11
3 Jun 2024
Pickering GAE


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 532 - 539
1 Jun 2024
Lei T Wang Y Li M Hua L

Aims

Intra-articular (IA) injection may be used when treating hip osteoarthritis (OA). Common injections include steroids, hyaluronic acid (HA), local anaesthetic, and platelet-rich plasma (PRP). Network meta-analysis allows for comparisons between two or more treatment groups and uses direct and indirect comparisons between interventions. This network meta-analysis aims to compare the efficacy of various IA injections used in the management of hip OA with a follow-up of up to six months.

Methods

This systematic review and network meta-analysis used a Bayesian random-effects model to evaluate the direct and indirect comparisons among all treatment options. PubMed, Web of Science, Clinicaltrial.gov, EMBASE, MEDLINE, and the Cochrane Library were searched from inception to February 2023. Randomized controlled trials (RCTs) which evaluate the efficacy of HA, PRP, local anaesthetic, steroid, steroid+anaesthetic, HA+PRP, and physiological saline injection as a placebo, for patients with hip OA were included.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 565 - 572
1 Jun 2024
Resl M Becker L Steinbrück A Wu Y Perka C

Aims. This study compares the re-revision rate and mortality following septic and aseptic revision hip arthroplasty (rTHA) in registry data, and compares the outcomes to previously reported data. Methods. This is an observational cohort study using data from the German Arthroplasty Registry (EPRD). A total of 17,842 rTHAs were included, and the rates and cumulative incidence of hip re-revision and mortality following septic and aseptic rTHA were analyzed with seven-year follow-up. The Kaplan-Meier estimates were used to determine the re-revision rate and cumulative probability of mortality following rTHA. Results. The re-revision rate within one year after septic rTHA was 30%, and after seven years was 34%. The cumulative mortality within the first year after septic rTHA was 14%, and within seven years was 40%. After multiple previous hip revisions, the re-revision rate rose to over 40% in septic rTHA. The first six months were identified as the most critical period for the re-revision for septic rTHA. Conclusion. The risk re-revision and reinfection after septic rTHA was almost four times higher, as recorded in the ERPD, when compared to previous meta-analysis. We conclude that it is currently not possible to assume the data from single studies and meta-analysis reflects the outcomes in the ‘real world’. Data presented in meta-analyses and from specialist single-centre studies do not reflect the generality of outcomes as recorded in the ERPD. The highest re-revision rates and mortality are seen in the first six months postoperatively. The optimization of perioperative care through the development of a network of high-volume specialist hospitals is likely to lead to improved outcomes for patients undergoing rTHA, especially if associated with infection. Cite this article: Bone Joint J 2024;106-B(6):565–572


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 118 - 124
1 May 2024
Macheras GA Argyrou C Tzefronis D Milaras C Tsivelekas K Tsiamtsouris KG Kateros K Papadakis SA

Aims

Accurate diagnosis of chronic periprosthetic joint infection (PJI) presents a significant challenge for hip surgeons. Preoperative diagnosis is not always easy to establish, making the intraoperative decision-making process crucial in deciding between one- and two-stage revision total hip arthroplasty (THA). Calprotectin is a promising point-of-care novel biomarker that has displayed high accuracy in detecting PJI. We aimed to evaluate the utility of intraoperative calprotectin lateral flow immunoassay (LFI) in THA patients with suspected chronic PJI.

Methods

The study included 48 THAs in 48 patients with a clinical suspicion of PJI, but who did not meet European Bone and Joint Infection Society (EBJIS) PJI criteria preoperatively, out of 105 patients undergoing revision THA at our institution for possible PJI between November 2020 and December 2022. Intraoperatively, synovial fluid calprotectin was measured with LFI. Cases with calprotectin levels ≥ 50 mg/l were considered infected and treated with two-stage revision THA; in negative cases, one-stage revision was performed. At least five tissue cultures were obtained; the implants removed were sent for sonication.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 32 - 39
1 May 2024
Briem T Stephan A Stadelmann VA Fischer MA Pfirrmann CWA Rüdiger HA Leunig M

Aims

The purpose of this study was to evaluate the mid-term outcomes of autologous matrix-induced chondrogenesis (AMIC) for the treatment of larger cartilage lesions and deformity correction in hips suffering from symptomatic femoroacetabular impingement (FAI).

Methods

This single-centre study focused on a cohort of 24 patients with cam- or pincer-type FAI, full-thickness femoral or acetabular chondral lesions, or osteochondral lesions ≥ 2 cm2, who underwent surgical hip dislocation for FAI correction in combination with AMIC between March 2009 and February 2016. Baseline data were retrospectively obtained from patient files. Mid-term outcomes were prospectively collected at a follow-up in 2020: cartilage repair tissue quality was evaluated by MRI using the Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) score. Patient-reported outcome measures (PROMs) included the Oxford Hip Score (OHS) and Core Outcome Measure Index (COMI). Clinical examination included range of motion, impingement tests, and pain.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 133 - 138
1 May 2024
Peuchot H Jacquet C Fabre-Aubrespy M Ferguson D Ollivier M Flecher X Argenson J

Aims

Dual-mobility acetabular components (DMCs) have improved total hip arthroplasty (THA) stability in femoral neck fractures (FNFs). In osteoarthritis, the direct anterior approach (DAA) has been promoted for improving early functional results compared with the posterolateral approach (PLA). The aim of this study was to compare these two approaches in FNF using DMC-THA.

Methods

A prospective continuous cohort study was conducted on patients undergoing operation for FNF using DMC by DAA or PLA. Functional outcome was evaluated using the Harris Hip Score (HHS) and Parker score at three months and one year. Perioperative complications were recorded, and radiological component positioning evaluated.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 125 - 132
1 May 2024
Carender CN Perry KI Sierra RJ Trousdale RT Berry DJ Abdel MP

Aims

Uncemented implants are now commonly used at reimplantation of a two-stage revision total hip arthoplasty (THA) following periprosthetic joint infection (PJI). However, there is a paucity of data on the performance of the most commonly used uncemented femoral implants – modular fluted tapered (MFT) femoral components – in this setting. This study evaluated implant survival, radiological results, and clinical outcomes in a large cohort of reimplantation THAs using MFT components.

Methods

We identified 236 reimplantation THAs from a single tertiary care academic institution from September 2000 to September 2020. Two designs of MFT femoral components were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years (SD 11), mean BMI was 32 kg/m2 (SD 7), and 46% (n = 109) were female. Mean follow-up was seven years (SD 4). A competing risk model accounting for death was used.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 59 - 65
1 May 2024
Liu WKT Cheung A Fu H Chan PK Chiu KY

Aims

Isolated acetabular liner exchange with a highly crosslinked polyethylene (HXLPE) component is an option to address polyethylene wear and osteolysis following total hip arthroplasty (THA) in the presence of a well-fixed acetabular shell. The liner can be fixed either with the original locking mechanism or by being cemented within the acetabular component. Whether the method used for fixation of the HXLPE liner has any bearing on the long-term outcomes is still unclear.

Methods

Data were retrieved for all patients who underwent isolated acetabular component liner exchange surgery with a HXLPE component in our institute between August 2000 and January 2015. Patients were classified according to the fixation method used (original locking mechanism (n = 36) or cemented (n = 50)). Survival and revision rates were compared. A total of 86 revisions were performed and the mean duration of follow-up was 13 years.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 47 - 53
1 May 2024
Jones SA Parker J Horner M

Aims

The aims of this study were to determine the success of a reconstruction algorithm used in major acetabular bone loss, and to further define the indications for custom-made implants in major acetabular bone loss.

Methods

We reviewed a consecutive series of Paprosky type III acetabular defects treated according to a reconstruction algorithm. IIIA defects were planned to use a superior augment and hemispherical acetabular component. IIIB defects were planned to receive either a hemispherical acetabular component plus augments, a cup-cage reconstruction, or a custom-made implant. We used national digital health records and registry reports to identify any reoperation or re-revision procedure and Oxford Hip Score (OHS) for patient-reported outcomes. Implant survival was determined via Kaplan-Meier analysis.


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 482 - 491
1 May 2024
Davies A Sabharwal S Liddle AD Zamora Talaya MB Rangan A Reilly P

Aims

Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey.

Methods

NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 112 - 117
1 May 2024
Hickie KL Neufeld ME Howard LC Greidanus NV Masri BA Garbuz DS

Aims

There are limited long-term studies reporting on outcomes of the Zimmer Modular Revision (ZMR) stem, and concerns remain regarding failure. Our primary aim was to determine long-term survival free from all-cause revision and stem-related failure for this modular revision stem in revision total hip arthroplasty (THA). Secondary aims included evaluating radiological and functional outcomes.

Methods

We retrospectively identified all patients in our institutional database who underwent revision THA using the ZMR system from January 2000 to December 2007. We included 106 patients (108 hips) with a mean follow-up of 14.5 years (2.3 to 22.3). Mean patient age was 69.2 years (37.0 to 89.4), and 51.9% were female (n = 55). Indications for index revision included aseptic loosening (73.1%), infection (16.7%), fracture (9.3%), and stem fracture (0.9%). Kaplan-Meier analysis was used to determine the all-cause and stem-related failure revision-free survival. At most recent follow-up, Oxford Hip Scores (OHS) were collected, and radiological stem stability was determined using the Engh classification.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 66 - 73
1 May 2024
Chaudhry F Daud A Greenberg A Braunstein D Safir OA Gross AE Kuzyk PR

Aims

Pelvic discontinuity is a challenging acetabular defect without a consensus on surgical management. Cup-cage reconstruction is an increasingly used treatment strategy. The present study evaluated implant survival, clinical and radiological outcomes, and complications associated with the cup-cage construct.

Methods

We included 53 cup-cage construct (51 patients) implants used for hip revision procedures for pelvic discontinuity between January 2003 and January 2022 in this retrospective review. Mean age at surgery was 71.8 years (50.0 to 92.0; SD 10.3), 43/53 (81.1%) were female, and mean follow-up was 6.4 years (0.02 to 20.0; SD 4.6). Patients were implanted with a Trabecular Metal Revision Shell with either a ZCA cage (n = 12) or a TMARS cage (n = 40, all Zimmer Biomet). Pelvic discontinuity was diagnosed on preoperative radiographs and/or intraoperatively. Kaplan-Meier survival analysis was performed, with failure defined as revision of the cup-cage reconstruction.


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 435 - 441
1 May 2024
Angelomenos V Mohaddes M Kärrholm J Malchau H Shareghi B Itayem R

Aims

Refobacin Bone Cement R and Palacos R + G bone cement were introduced to replace the original cement Refobacin Palacos R in 2005. Both cements were assumed to behave in a biomechanically similar fashion to the original cement. The primary aim of this study was to compare the migration of a polished triple-tapered femoral stem fixed with either Refobacin Bone Cement R or Palacos R + G bone cement. Repeated radiostereometric analysis was used to measure migration of the femoral head centre. The secondary aims were evaluation of cement mantle, stem positioning, and patient-reported outcome measures.

Methods

Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected.


Bone & Joint Open
Vol. 5, Issue 4 | Pages 367 - 373
26 Apr 2024
Reinhard J Lang S Walter N Schindler M Bärtl S Szymski D Alt V Rupp M

Aims

Periprosthetic joint infection (PJI) demonstrates the most feared complication after total joint replacement (TJR). The current work analyzes the demographic, comorbidity, and complication profiles of all patients who had in-hospital treatment due to PJI. Furthermore, it aims to evaluate the in-hospital mortality of patients with PJI and analyze possible risk factors in terms of secondary diagnosis, diagnostic procedures, and complications.

Methods

In a retrospective, cross-sectional study design, we gathered all patients with PJI (International Classification of Diseases (ICD)-10 code: T84.5) and resulting in-hospital treatment in Germany between 1 January 2019 and 31 December 2022. Data were provided by the Institute for the Hospital Remuneration System in Germany. Demographic data, in-hospital deaths, need for intensive care therapy, secondary diagnosis, complications, and use of diagnostic instruments were assessed. Odds ratios (ORs) with 95% confidence intervals (CIs) for in-hospital mortality were calculated.


Bone & Joint Research
Vol. 13, Issue 4 | Pages 193 - 200
23 Apr 2024
Reynolds A Doyle R Boughton O Cobb J Muirhead-Allwood S Jeffers J

Aims

Manual impaction, with a mallet and introducer, remains the standard method of installing cementless acetabular cups during total hip arthroplasty (THA). This study aims to quantify the accuracy and precision of manual impaction strikes during the seating of an acetabular component. This understanding aims to help improve impaction surgical techniques and inform the development of future technologies.

Methods

Posterior approach THAs were carried out on three cadavers by an expert orthopaedic surgeon. An instrumented mallet and introducer were used to insert cementless acetabular cups. The motion of the mallet, relative to the introducer, was analyzed for a total of 110 strikes split into low-, medium-, and high-effort strikes. Three parameters were extracted from these data: strike vector, strike offset, and mallet face alignment.


Bone & Joint Open
Vol. 5, Issue 4 | Pages 286 - 293
9 Apr 2024
Upadhyay PK Kumar V Mirza SB Shah N

Aims

This study reports the results of 38 total hip arthroplasties (THAs) in 33 patients aged less than 50 years, using the JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component.

Methods

We describe the survival, radiological, and functional outcomes of 33 patients (38 THAs) at a mean follow-up of 27 years (25 to 32) between 1988 and 2018.


Aims

The aims of this study were to evaluate the incidence of reoperation (all cause and specifically for periprosthetic femoral fracture (PFF)) and mortality, and associated risk factors, following a hemiarthroplasty incorporating a cemented collarless polished taper slip stem (PTS) for management of an intracapsular hip fracture.

Methods

This retrospective study included hip fracture patients aged 50 years and older treated with Exeter (PTS) bipolar hemiarthroplasty between 2019 and 2022. Patient demographics, place of domicile, fracture type, delirium status, American Society of Anesthesiologists (ASA) grade, length of stay, and mortality were collected. Reoperation and mortality were recorded up to a median follow-up of 29.5 months (interquartile range 12 to 51.4). Cox regression was performed to evaluate independent risk factors associated with reoperation and mortality.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 401 - 411
1 Apr 2024
Carrothers A O'Leary R Hull P Chou D Alsousou J Queally J Bond SJ Costa ML

Aims. To assess the feasibility of a randomized controlled trial (RCT) that compares three treatments for acetabular fractures in older patients: surgical fixation, surgical fixation and hip arthroplasty (fix-and-replace), and non-surgical treatment. Methods. Patients were recruited from seven UK NHS centres and randomized to a three-arm pilot trial if aged older than 60 years and had a displaced acetabular fracture. Feasibility outcomes included patients’ willingness to participate, clinicians’ capability to recruit, and dropout rates. The primary clinical outcome measure was the EuroQol five-dimension questionnaire (EQ-5D) at six months. Secondary outcomes were Oxford Hip Score, Disability Rating Index, blood loss, and radiological and mobility assessments. Results. Between December 2017 and December 2019, 60 patients were recruited (median age 77.4 years, range 63.3 to 88.5) (39/21 M/F ratio). At final nine-month follow-up, 4/60 (7%) had withdrawn, 4/60 (7%) had died, and one had been lost to follow-up; a 98% response rate (50/51) was achieved for the EQ-5D questionnaire. Four deaths were recorded during the three-year trial period: three in the non-surgical treatment group and one in the fix-and-replace group. Conclusion. This study has shown a full-scale RCT to be feasible, but will need international recruitment. The Acetabular Fractures in older patients Intervention Trial (AceFIT) has informed the design of a multinational RCT sample size of 1,474 or 1,974 patients for a minimal clinically important difference of 0.06 on EQ-5D, with a power of 0.8 or 0.9, and loss to follow-up of 20%. This observed patient cohort comprises a medically complex group requiring multidisciplinary care; surgeon, anaesthetist, and ortho-geriatrician input is needed to optimize recovery and rehabilitation. Cite this article: Bone Joint J 2024;106-B(4):401–411


Bone & Joint 360
Vol. 13, Issue 2 | Pages 47 - 49
1 Apr 2024
Burden EG Krause T Evans JP Whitehouse MR Evans JT


Aims

Revision total hip arthroplasty in patients with Vancouver type B3 fractures with Paprosky type IIIA, IIIB, and IV femoral defects are difficult to treat. One option for Paprovsky type IIIB and IV defects involves modular cementless, tapered, revision femoral components in conjunction with distal interlocking screws. The aim of this study was to analyze the rate of reoperations and complications and union of the fracture, subsidence of the stem, mortality, and the clinical outcomes in these patients.

Methods

A total of 46 femoral components in patients with Vancouver B3 fractures (23 with Paprosky type IIIA, 19 with type IIIB, and four with type IV defects) in 46 patients were revised with a transfemoral approach using a modular, tapered, cementless revision Revitan curved femoral component with distal cone-in-cone fixation and prospectively followed for a mean of 48.8 months (SD 23.9; 24 to 112). The mean age of the patients was 80.4 years (66 to 100). Additional distal interlocking was also used in 23 fractures in which distal cone-in-cone fixation in the isthmus was < 3 cm.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 319 - 322
1 Apr 2024
Parsons N Whitehouse MR Costa ML