Advertisement for orthosearch.org.uk
Results 1 - 20 of 1724
Results per page:
Bone & Joint Open
Vol. 6, Issue 2 | Pages 126 - 134
4 Feb 2025
Schneller T Kraus M Schätz J Moroder P Scheibel M Lazaridou A

Aims

Machine learning (ML) holds significant promise in optimizing various aspects of total shoulder arthroplasty (TSA), potentially improving patient outcomes and enhancing surgical decision-making. The aim of this systematic review was to identify ML algorithms and evaluate their effectiveness, including those for predicting clinical outcomes and those used in image analysis.

Methods

We searched the PubMed, EMBASE, and Cochrane Central Register of Controlled Trials databases for studies applying ML algorithms in TSA. The analysis focused on dataset characteristics, relevant subspecialties, specific ML algorithms used, and their performance outcomes.


Bone & Joint 360
Vol. 14, Issue 1 | Pages 36 - 39
1 Feb 2025

The February 2025 Trauma Roundup360 looks at: Risk factors for nonunion in femoral neck fracture patients with internal fixation: a multicentre (TRON group) retrospective study; Tranexamic acid administered at time of hospital admission does not decrease transfusion rates or blood loss for extracapsular hip fractures; The effect of anterior support screw (AS2) in unstable femoral trochanteric fractures; The effect of coronal plane angulation on patient-reported outcome measures of operatively treated distal femur fractures; Do proximal humerus fractures treated nonoperatively benefit from supervised physiotherapy?; Cephalomedullary nails: are dual lag screws superior to single lag screws?; Does cement need to be pressurized for hemiarthroplasty?.


Bone & Joint 360
Vol. 14, Issue 1 | Pages 7 - 10
1 Feb 2025
Ollivere B


Bone & Joint 360
Vol. 14, Issue 1 | Pages 42 - 46
1 Feb 2025

The February 2025 Children’s orthopaedics Roundup360 looks at: Are antibiotics enough for the initial management of paediatric Gustilo-Anderson type I upper limb open fractures?; Advanced imaging for tibial tubercle fractures; Spinal fusion improves quality of life in cerebral palsy scoliosis: a multicentre study; Hip displacement after triradiate closure in ambulatory cerebral palsy; Telehealth validation for adolescent idiopathic scoliosis: comparable clinical measurements enhance access to care; Long-term prognostic markers for residual dysplasia in developmental dysplasia of the hip after closed reduction; Open versus closed reduction for paediatric lateral humeral condyle fractures: better outcomes with closed techniques; Delayed diagnosis of paediatric septic hip leads to poor outcomes and doubling of healthcare costs.


Bone & Joint 360
Vol. 14, Issue 1 | Pages 26 - 29
1 Feb 2025

The February 2025 Wrist & Hand Roundup360 looks at: Delayed fixation of distal radial fractures beyond three weeks increases the odds of reoperation; A systematic review of management options for symptomatic scaphometacarpal impingement after trapeziectomy; Diagnosing occult scaphoid fractures: an art or science?; Dual-mobility trapeziometacarpal arthroplasty shows promising outcomes but lacks long-term evidence; 3D-printed titanium scaphoid implant offers a promising alternative for unreconstructable scaphoid nonunion; Lidocaine co-injection reduces pain intensity during corticosteroid injections in hand and wrist conditions; Long-term outcomes of PyroDisk arthroplasty for trapeziometacarpal osteoarthritis; Evaluating the impact of COVID-19 on hand surgery practices: adaptations and missed opportunities.


The Bone & Joint Journal
Vol. 107-B, Issue 2 | Pages 181 - 187
1 Feb 2025
Barret H Tiercelin J Godenèche A Charousset C Audebert S Lefebvre Y Gallinet D Barth J Bonnevialle N

Aims. Loosening of the glenoid component in the long term remains an important complication of the anatomical total shoulder arthroplasty (aTSA). The aim of this study was to explore the bony integration of a hybrid glenoid component based on an analysis of CT scans. Methods. In a prospective multicentre study, patients who underwent primary aTSA, whose hybrid design of glenoid component included a fully-polyethylene flanged upper peg and a porous-coated titanium lower peg, and who were reviewed with CT scans between 12 and 24 months postoperatively, were included. Two independent observers reviewed the scans. Bony integration of the upper peg was scored as described by Arnold et al, and integration of the lower peg was scored as described by Gulotta et al. Perforation of the glenoid vault in any plane was also assessed. Results. From an initial group of 120 aTSAs in 116 patients, 104 CT scans were analyzed in 100 patients (four bilateral shoulders, mean age 66 years (SD 11), 62 female and 38 male). Osteolysis around the upper peg was found in 32 patients (32 aTSAs; 31%). Of the remaining patients, 72 had a mean Arnold score of 5.6 points (SD 0.9), and 70 (67%) had perfect integration. The lower peg had a mean Gulotta score of 6.5 points (SD 1.4). There was perfect integration of the lower peg in 70 patients (70 aTSAs; 67%). A total of nine patients (nine aTSAs; 9%) had no bony integration at either peg. There was perforation of the glenoid in an anterior or posterior direction at the level of the upper peg in three and 28 patients, respectively. This occurred at the level of the lower peg in 11 and 18 patients, respectively. The inter- and intraobserver reliability was good (k = 0.782 and 0.86, respectively). No implant breakage occurred at a mean follow-up of 16 months (12 to 24). The clinical outcome was satisfactory at a mean follow-up of 32 months (24 to 35), as assessed by a visual analogue scale score for pain, the Constant-Murley score, Subjective Shoulder Value, and American Shoulder and Elbow Surgeons score. Conclusion. Short-term CT scan analysis of a new hybrid anatomical glenoid component found perfect bony integration around the lower porous coated titanium peg in 90% of patients. The upper polyethylene flanged peg had bony integration in 70 patients (70 aTSAs; 67%). Longer follow-up is needed to analyze the rate of survival of this component. The short-term clinical outcome was satisfactory. Cite this article: Bone Joint J 2025;107-B(2):181–187


Bone & Joint 360
Vol. 14, Issue 1 | Pages 39 - 42
1 Feb 2025

The February 2025 Oncology Roundup360 looks at:The role of bone grafting versus bone cement in the treatment of giant cell tumour of bone: a systematic review and meta-analysis on the risk of recurrence in 1,454 patients; Tumour necrosis drives prognosis in osteosarcoma; Correlation between post-chemotherapy MRI and histopathology of malignant bone tumours treated with extra-articular resection; Real-world referral pattern of unplanned excision in patients with soft-tissue sarcoma; Assessment of artificial intelligence chatbot responses to common patient questions on bone sarcoma; Chondrosarcoma of the pelvis and limbs at ten years; Chest wall resection and reconstruction for primary chest wall sarcomas: analysis of survival, predictors of outcome, and long-term functional status; Ewing’s sarcoma in the paediatric population: predictors of survival within the USA; Pulmonary metastasectomy for sarcoma: insights from a referral centre cohort.


Bone & Joint 360
Vol. 14, Issue 1 | Pages 30 - 33
1 Feb 2025

The February 2025 Shoulder & Elbow Roundup. 360. looks at: Reverse shoulder arthroplasty is superior to plate fixation for displaced proximal humeral fractures in the elderly; Long-term outcomes of reverse total shoulder arthroplasty for complex proximal humerus fractures; The RAND/UCLA algorithm does streamline the clinical decision-making process; Smoking negatively impacts long-term outcomes and survival after anatomical total shoulder arthroplasty; Evaluating subscapularis tears: special tests lack sensitivity to tear severity and pain; Rotator cuff tear progression: insights into rates, risk factors, and the need for standardized reporting; Outcomes and complications of revision reverse shoulder arthroplasty: a systematic review; Prevalence and risk factors of glenohumeral chondral damage in shoulder instability: implications for early surgical stabilization


The Bone & Joint Journal
Vol. 107-B, Issue 2 | Pages 173 - 180
1 Feb 2025
Engseth LHW Øhrn F Schulz A Röhrl SM

Aims. Radiostereometric analysis (RSA) is considered the gold standard for in vivo migration analysis, but CT-based alternatives show comparable results in the shoulder and hip. We have previously validated a CT-based migration analysis method (CTMA) in a knee phantom compared to RSA. In this study, we validated the method in patients undergoing total knee arthroplasty (TKA). Our primary outcome measure was the difference in maximum total point motion (MTPM) between the differing methods. Methods. A total of 31 patients were prospectively studied having undergone an uncemented medial pivot knee TKA. Migrations were measured up to 12 months with marker-based and model-based RSA, and CT-RSA. Results. Mean precision data for MTPM were 0.27 mm (SD 0.09) for marker-based RSA, 0.37 mm (SD 0.26) for model-based RSA, and 0.25 mm (SD 0.11) for CTMA. CTMA was as precise as both RSA methods (p = 0.845 and p = 0.156). At three months, MTPM showed a mean of 0.66 mm (95% CI 0.52 to 0.81) for marker-based RSA, 0.79 (95% CI 0.64 to 0.94) for model-based RSA, and 0.59 (95% CI 0.47 to 0.72) for CTMA. There was no difference between CTMA and marker-based RSA (p = 0.400), but CTMA showed lower migration than model-based RSA (p = 0.019). At 12 months, MTPM was 1.03 (95% CI 0.79 to 1.26) for marker-based RSA, 1.02 (95% CI 0.79 to 1.25) for model-based RSA, and 0.71 (95% CI 0.48 to 0.94) for CTMA. MTPM for CTMA was lower than both RSA methods (p < 0.001). Differences between migration increased between the methods from three to 12 months. Mean effective radiation doses per examination were 0.016 mSv (RSA) and 0.069 mSv (CT). Imaging time for performing RSA radiographs was 17 minutes 26 seconds (SD 7 mins 9 sec) and 4 minutes 24 seconds (SD 2 mins 3 sec) for CT. Conclusion. No difference in precision was found between CTMA and marker- or model-based RSA, but CTMA shows lower migration values of the tibial component at 12 months. CTMA can be used with low effective radiation doses, and CT image acquisition is faster to perform than RSA methods and may be suitable for use in ordinary clinical settings. Cite this article: Bone Joint J 2025;107-B(2):173–180


Bone & Joint Open
Vol. 6, Issue 1 | Pages 82 - 92
14 Jan 2025
Ranieri R Borroni M Delle Rose G Conti M Garofalo R Castagna A

Aims. The aim of this study was to report long-term clinical outcomes of a modern convertible metal-backed glenoid (MBG) in total shoulder arthroplasty (TSA). Methods. After a minimum of 15 years, a previously studied cohort of 35 patients who received a modern convertible MBG during the period 1996 to 2005 was contacted for clinical and radiological follow-up. At last follow-up, patients were evaluated radiologically and clinically according to the Constant Score, Simple Shoulder Test, and visual analogue scale for pain. Complications and revisions were recorded, and survival analysis was performed. Results. At the last follow-up, 20 patients were contacted. Of these, 15 patients had experienced at least one complication, and ten underwent revision surgery. The mean time to revision was 13.8 years (7 to 20). Cuff failure was the most common complication. Conversion to reverse shoulder arthroplasty, while maintaining the baseplate, was possible in five cases, with good results. In patients in whom the baseplate was removed, revision was performed significantly later (18.4 vs 11.1 years; p = 0.016). The general revision-free survival was 73% (95% CI 49.5 to 87.3) at 15 years and 38% (95% CI 11.8% to 64.3%) at 20 years, while MBG revision-free survival was 96.0% (95% CI 74.8% to 99.4%) at 15 years and 54% (95% CI 16.2% to 80.8%) at 20 years. Clinical scores showed a negative trend over time, although not statistically significant. Radiologically, polyethylene wear was observed in all cases and was complete in 12 out of 19 cases, and five glenoids were ‘at risk’ for loosening. Conclusion. At long-term follow-up, convertible MBG-TSA revealed a high rate of complications and revision surgery, mainly due to soft-tissue failure and polyethylene wear occurring with time. Prompt conversion to RSA maintaining the baseplate provided good results and a low complication rate. Radiological follow-up at about ten years is strictly recommended and, if metal-to-metal contact is observed, conversion to RSA is advisable. These results emphasize the need for continued research into improving TSA outcomes, especially in cases of MBG usage. Cite this article: Bone Jt Open 2025;6(1):82–92


Bone & Joint Open
Vol. 6, Issue 1 | Pages 74 - 81
13 Jan 2025
van Veghel MHW van Steenbergen LN Gademan MGJ van den Hout WB Schreurs BW Hannink G

Aims. We estimated the prevalence of people living with at least one hip, knee, or shoulder arthroplasty in the Netherlands. Methods. We included the first hip (n = 416,333), knee (n = 314,569), or shoulder (n = 23,751) arthroplasty of each patient aged ≥ 40 years between 2007 and 2022 (hip/knee) or 2014 and 2022 (shoulder) from the Dutch Arthroplasty Register (LROI). Data on the size of the Dutch population were obtained from Statistics Netherlands. Annual incidences and deaths from hip and knee arthroplasty since 2010, and shoulder arthroplasty since 2015, were observed from the LROI. Annual incidences and deaths before those years were estimated using Poisson regression analyses and parametric survival models based on a Gompertz distribution. Non-parametric percentile bootstrapping with resampling was used to estimate 95% CIs. Results. Annual incidences per 100,000 Dutch inhabitants aged ≥ 40 years increased for hip arthroplasties from 221 (95% CI 214 to 229) in 1990 to 360 in 2022, for knee arthroplasties from 181 (95% CI 174 to 188) to 272, and for shoulder arthroplasties from 11 (95% CI 8.0 to 16) to 34. In 2022, 791,000 (95% CI 787,000 to 794,000) people in the Netherlands were living with at least one joint replacement, representing 8.4% (95% CI 8.4 to 8.5) of the Dutch population aged ≥ 40 years. For hip, knee, and shoulder arthroplasties, these were 436,000 (95% CI 433,000 to 438,000), 383,000 (95% CI 380,000 to 386,000), and 34,000 (95% CI 33,000 to 36,000) people, corresponding to 4.7% (95% CI 4.6 to 4.7), 4.1% (95% CI 4.1 to 4.1), and 0.4% (95% CI 0.3 to 0.4) of the Dutch population, respectively. The most common age group living with at least one joint replacement was the ≥ 80-year age group, representing 38% (95% CI 37 to 38) of the Dutch population aged ≥ 80 years. Conclusion. Approximately 800,000 people in the Netherlands were living with at least one hip, knee, or shoulder replacement in 2022, representing one in 12 Dutch inhabitants aged ≥ 40 years. Cite this article: Bone Jt Open 2025;6(1):74–81


Bone & Joint Open
Vol. 6, Issue 1 | Pages 62 - 73
11 Jan 2025
Mc Colgan R Boland F Sheridan GA Colgan G Bose D Eastwood DM Dalton DM

Aims

The aim of this study was to explore differences in operative autonomy by trainee gender during orthopaedic training in Ireland and the UK, and to explore differences in operative autonomy by trainee gender with regard to training year, case complexity, index procedures, and speciality area.

Methods

This retrospective cohort study examined all operations recorded by orthopaedic trainees in Ireland and the UK between July 2012 and July 2022. The primary outcome was operative autonomy, which was defined as the trainee performing the case without the supervising trainer scrubbed.


Bone & Joint Open
Vol. 6, Issue 1 | Pages 35 - 42
8 Jan 2025
Fischer M Nonnenmacher L Hofer A Zimmerer A Nitsch A Großjohann R Erdmann S Wassilew GI

Aims

Periacetabular osteotomy (PAO) is well established for acetabular reorientation and has shown successful improvement in patient-reported outcome measures (PROMs). Nevertheless, studies focusing on postoperative outcomes related to patient individual factors are still underrepresented. Therefore, this study aimed to analyze the functional outcome and activity level in relation to patient sex with a minimum follow-up of two years after PAO for mild to severe hip dysplasia.

Methods

A single-centre study was conducted, enrolling patients undergoing PAO and completing a preoperative and postoperative radiological and clinical outcome assessment. The PROMs were assessed using the modified Harris Hip Score (mHHS), the Hip disability and Osteoarthritis Outcome Score (HOOS) with the subscales for pain, sport, activities of daily living (ADL), and quality of life (QoL), and the University of California, Los Angeles (UCLA) activity score. Kendall’s tau were calculated for correlation analyses.


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 34 - 41
1 Jan 2025
Tokuyasu H Kim Y Vergari C Tada H Tanaka C Takemoto M

Aims

Overall sagittal flexion is restricted in patients who have undergone both lumbar fusion and total hip arthroplasty (THA). However, it is not evident to what extent this movement is restricted in these patients and how this influences quality of life (QoL). The purpose of this study was to determine the extent to which hip-lumbar mobility is decreased in these patients, and how this affects their QoL score.

Methods

Patients who underwent primary THA at our hospital between January 2010 and March 2021 were considered (n = 976). Among them, 44 patients who underwent lumbar fusion were included as cases, and 44 THA patients without lumbar disease matched by age, sex, and BMI as Control T. Among those who underwent lumbar fusion, 44 patients without hip abnormalities matched by age, sex, and BMI to the cases were considered as Control F. Outcome and spinopelvic parameters were measured radiologically in extension and flexed-seated positions. Hip, lumbar, and hip-lumbar mobility were calculated as parameter changes between positions.


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 97 - 102
1 Jan 2025
Smeitink N Schröder FF Dorrestijn O Spekenbrink-Spooren A Govaert LHM Veen EJD

Aims. Hemiarthroplasty (HA) and total shoulder arthroplasty (TSA) are often the preferred forms of treatment for patients with atraumatic avascular necrosis of the humeral head when conservative treatment fails. Little has been reported about the survival of HA and TSA for this indication. The aim of this study was to investigate the differences in revision rates between HA and TSA in these patients, to determine whether one of these implants has a superior survival and may be a better choice in the treatment of this condition. Methods. Data from 280 shoulders with 159 primary HAs and 121 TSAs, which were undertaken in patients with atraumatic avascular necrosis of the humeral head between January 2014 and January 2023 from the Dutch Arthroplasty Register (LROI), were included. Kaplan-Meier survival analysis and Cox regression analysis were undertaken. Results. Within four years of follow-up, a total of 15 revisions were required, involving seven HAs (4%) and eight TSAs (7%). This difference was not statistically significant (p = 0.523). Two HAs were revised because of progressive glenoid erosion, and three TSAs were revised for loosening of the glenoid component. The cumulative percentages of revision of HA and TSA were 6% and 8%, respectively (HR 1.1 (95% CI 0.5 to 2.7)). Conclusion. We found no significant difference in short- to mid-term implant survival between the use of a HA and a TSA in the treatment of atraumatic avascular necrosis of the humeral head, without significant glenoid wear. Cite this article: Bone Joint J 2025;107-B(1):97–102


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 19 - 26
1 Jan 2025
Bennett J Patel N Nantha-Kumar N Phillips V Nayar SK Kang N

Aims. Frozen shoulder is a common and debilitating condition characterized by pain and restricted movement at the glenohumeral joint. Various treatment methods have been explored to alleviate symptoms, with suprascapular nerve block (SSNB) emerging as a promising intervention. This meta-analysis aimed to assess the effectiveness of SSNB in treating frozen shoulder. Methods. The study protocol was registered with PROSPERO (CRD42023475851). We searched the MEDLINE, Embase, and Cochrane Library databases in November 2023. Randomized controlled trials (RCTs) comparing SSNB against other interventions were included. The primary outcome was any functional patient-reported outcome measure. Secondary outcomes were the visual analogue scale (VAS) for pain, range of motion (ROM), and complications. Risk of bias was assessed using the Cochrane risk of bias v. 2.0 tool. Results. A total of 12 RCTs were identified (702 patients; mean age 55 years (30 to 72)). Eight RCTs were deemed “low” risk-of-bias and four raised “some concerns”. Comparator interventions included intra-articular steroid injection (IAI), hydrodistension, physiotherapy, and placebo injection with 0.9% saline. Seven studies compared SSNB to IAI, with SSNB resulting in greater improvement in the Shoulder and Pain Disability Index (mean difference -4.75 (95% CI -8.11 to -1.39); p = 0.006) and external rotation (mean difference 11.64 (95% CI -0.05 to 23.33); p = 0.050). In three studies, SSNB demonstrated better VAS (mean difference -0.31 (95% CI -0.53 to 1.79); p = 0.004) compared to physiotherapy (with or without placebo injection). One study favoured hydrodistension over SSNB in improving ROM and VAS. There was no significant difference in outcomes between SSNB administered under ultrasound guidance or using a landmark technique. Conclusion. SSNB can be administered in the outpatient clinic with promising outcomes compared to IAI or physiotherapy based on level I evidence. It can therefore be considered as a first-line treatment option. Cite this article: Bone Joint J 2025;107-B(1):19–26


Bone & Joint Open
Vol. 5, Issue 12 | Pages 1114 - 1119
19 Dec 2024
Wachtel N Giunta RE Hellweg M Hirschmann M Kuhlmann C Moellhoff N Ehrl D

Aims. The free latissimus dorsi muscle (LDM) flap represents a workhorse procedure in the field of trauma and plastic surgery. However, only a small number of studies have examined this large group of patients with regard to the morbidity of flap harvest. The aim of this prospective study was therefore to objectively investigate the morbidity of a free LDM flap. Methods. A control group (n = 100) without surgery was recruited to assess the differences in strength and range of motion (ROM) in the shoulder joint with regard to handedness of patients. Additionally, in 40 patients with free LDM flap surgery, these parameters were assessed in an identical manner. Results. We measured higher values for all parameters assessing force in the shoulder joint on the dominant side of patients in the control group. Moreover, LDM flap harvest caused a significant reduction in strength in the glenohumeral joint in all functions of the LDM that were assessed, ranging from 9.0% to 13.8%. Equally, we found a significantly reduced ROM in the shoulder at the side of the flap harvest. For both parameters, this effect was diminished, when the flap harvest took place on the dominant side of the patient. Conclusion. LDM flap surgery leads to a significant impairment of the strength and ROM in the shoulder joint. Moreover, the donor morbidity must be differentiated with regard to handedness: harvest on the non-dominant side potentiates the already existing difference in strength and ROM. Conversely, if the harvest takes place on the dominant side of the patient, this difference is diminished. Cite this article: Bone Jt Open 2024;5(12):1114–1119


Bone & Joint Open
Vol. 5, Issue 12 | Pages 1092 - 1100
8 Dec 2024
Fraser E Spence S Farhan-Alanie OM Doonan J Mahendra A Gupta S

Aims

Limb salvage surgery (LSS) is the primary treatment option for primary bone malignancy. It involves the removal of bone and tissue, followed by reconstruction with endoprosthetic replacements (EPRs) to prevent amputation. Trabecular metal (TM) collars have been developed to encourage bone ingrowth (osseointegration (OI)) into EPRs. The primary aim of this study was to assess whether OI occurs when TM collars are used in EPRs for tumour.

Methods

A total of 124 patients from July 2010 to August 2021 who underwent an EPR for tumour under the West of Scotland orthopaedic oncology team were identified. Overall, 81 patients (65%) met the inclusion criteria, and two consultants independently analyzed radiographs at three and 12 months, as well as the last radiograph, using a modified version of the Stanford Radiological Assessment System.


Bone & Joint Open
Vol. 5, Issue 12 | Pages 1072 - 1080
4 Dec 2024
Tang M Lun KK Lewin AM Harris IA

Aims

Systematic reviews of randomized controlled trials (RCTs) are the highest level of evidence used to inform patient care. However, it has been suggested that the quality of randomization in RCTs in orthopaedic surgery may be low. This study aims to describe the quality of randomization in trials included in systematic reviews in orthopaedic surgery.

Methods

Systematic reviews of RCTs testing orthopaedic procedures published in 2022 were extracted from PubMed, Embase, and the Cochrane Library. A random sample of 100 systematic reviews was selected, and all included RCTs were retrieved. To be eligible for inclusion, systematic reviews must have tested an orthopaedic procedure as the primary intervention, included at least one study identified as a RCT, been published in 2022 in English, and included human clinical trials. The Cochrane Risk of Bias-2 Tool was used to assess random sequence generation as ‘adequate’, ‘inadequate’, or ‘no information’; we then calculated the proportion of trials in each category. We also collected data to test the association between these categories and characteristics of the RCTs and systematic reviews.


Bone & Joint Research
Vol. 13, Issue 12 | Pages 716 - 724
4 Dec 2024
Cao S Chen Y Zhu Y Jiang S Yu Y Wang X Wang C Ma X

Aims

This cross-sectional study aimed to investigate the in vivo ankle kinetic alterations in patients with concomitant chronic ankle instability (CAI) and osteochondral lesion of the talus (OLT), which may offer opportunities for clinician intervention in treatment and rehabilitation.

Methods

A total of 16 subjects with CAI (eight without OLT and eight with OLT) and eight healthy subjects underwent gait analysis in a stair descent setting. Inverse dynamic analysis was applied to ground reaction forces and marker trajectories using the AnyBody Modeling System. One-dimensional statistical parametric mapping was performed to compare ankle joint reaction force and joint moment curve among groups.