Delayed postoperative inoculation of orthopaedic implants with persistent wound drainage or bacterial seeding of a haematoma can result in periprosthetic joint infection (PJI). The aim of this in vivo study was to compare the efficacy of vancomycin powder with vancomycin-eluting calcium sulphate beads in preventing PJI due to delayed inoculation. A mouse model of PJI of the knee was used. Mice were randomized into groups with intervention at the time of surgery (postoperative day (POD) 0): a sterile control (SC; n = 6); infected control (IC; n = 15); systemic vancomycin (SV; n = 9); vancomycin powder (VP; n = 21); and vancomycin bead (VB; n = 19) groups. Delayed inoculation was introduced during an arthrotomy on POD 7 with 1 × 105 colony-forming units (CFUs) of a bioluminescent strain of Aims
Methods
The April 2024 Knee Roundup. 360. looks at: Challenging the status quo: re-evaluating the impact of obesity on unicompartmental knee arthroplasty outcomes; Timing matters: the link between ACL reconstruction delays and cartilage damage; Custom fit or off the shelf: evaluating patient outcomes in tailored versus standard knee replacements; Revolutionizing knee replacement: a comparative study on robotic-assisted and computer-navigated techniques; Pre-existing knee osteoarthritis and severe joint depression are associated with the need for total knee arthroplasty after
Aims. Proper preoperative planning benefits fracture reduction, fixation, and stability in
Aims. This study aims to determine the rate of and risk factors for total knee arthroplasty (TKA) after operative management of
This prospective study reports longitudinal, within-patient, patient-reported outcome measures (PROMs) over a 15-year period following cemented single radius total knee arthroplasty (TKA). Secondary aims included reporting PROMs trajectory, 15-year implant survival, and patient attrition from follow-up. From 2006 to 2007, 462 consecutive cemented cruciate-retaining Triathlon TKAs were implanted in 426 patients (mean age 69 years (21 to 89); 290 (62.7%) female). PROMs (12-item Short Form Survey (SF-12), Oxford Knee Score (OKS), and satisfaction) were assessed preoperatively and at one, five, ten, and 15 years. Kaplan-Meier survival and univariate analysis were performed.Aims
Methods
The use of artificial intelligence (AI) is rapidly growing across many domains, of which the medical field is no exception. AI is an umbrella term defining the practical application of algorithms to generate useful output, without the need of human cognition. Owing to the expanding volume of patient information collected, known as ‘big data’, AI is showing promise as a useful tool in healthcare research and across all aspects of patient care pathways. Practical applications in orthopaedic surgery include: diagnostics, such as fracture recognition and tumour detection; predictive models of clinical and patient-reported outcome measures, such as calculating mortality rates and length of hospital stay; and real-time rehabilitation monitoring and surgical training. However, clinicians should remain cognizant of AI’s limitations, as the development of robust reporting and validation frameworks is of paramount importance to prevent avoidable errors and biases. The aim of this review article is to provide a comprehensive understanding of AI and its subfields, as well as to delineate its existing clinical applications in trauma and orthopaedic surgery. Furthermore, this narrative review expands upon the limitations of AI and future direction. Cite this article:
This is a multicentre, prospective assessment of a proportion of the overall orthopaedic trauma caseload of the UK. It investigates theatre capacity, cancellations, and time to surgery in a group of hospitals that is representative of the wider population. It identifies barriers to effective practice and will inform system improvements. Data capture was by collaborative approach. Patients undergoing procedures from 22 August 2022 and operated on before 31 October 2022 were included. Arm one captured weekly caseload and theatre capacity. Arm two concerned patient and injury demographics, and time to surgery for specific injury groups.Aims
Methods
Aims. To investigate health-related quality of life (HRQoL) of older adults (aged ≥ 60 years) after
The April 2023 Trauma Roundup. 360. looks at: Displaced femoral neck fractures in patients aged 55 to 70 years: internal fixation or total hip arthroplasty?;
This study aimed to answer the following questions: do 3D-printed models lead to a more accurate recognition of the pattern of complex fractures of the elbow?; do 3D-printed models lead to a more reliable recognition of the pattern of these injuries?; and do junior surgeons benefit more from 3D-printed models than senior surgeons? A total of 15 orthopaedic trauma surgeons (seven juniors, eight seniors) evaluated 20 complex elbow fractures for their overall pattern (i.e. varus posterior medial rotational injury, terrible triad injury, radial head fracture with posterolateral dislocation, anterior (trans-)olecranon fracture-dislocation, posterior (trans-)olecranon fracture-dislocation) and their specific characteristics. First, fractures were assessed based on radiographs and 2D and 3D CT scans; and in a subsequent round, one month later, with additional 3D-printed models. Diagnostic accuracy (acc) and inter-surgeon reliability (κ) were determined for each assessment.Aims
Methods
Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects. We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures.Aims
Methods
Aims. A fracture of the medial tibial plateau is a serious complication of Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). The risk of these fractures is reportedly lower when using components with a longer keel-cortex distance (KCDs). The aim of this study was to examine how slight varus placement of the tibial component might affect the KCDs, and the rate of
The purpose of this study was to determine the weightbearing practice of operatively managed fragility fractures in the setting of publically funded health services in the UK and Ireland. The Fragility Fracture Postoperative Mobilisation (FFPOM) multicentre audit included all patients aged 60 years and older undergoing surgery for a fragility fracture of the lower limb between 1 January 2019 and 30 June 2019, and 1 February 2021 and 14 March 2021. Fractures arising from high-energy transfer trauma, patients with multiple injuries, and those associated with metastatic deposits or infection were excluded. We analyzed this patient cohort to determine adherence to the British Orthopaedic Association Standard, “all surgery in the frail patient should be performed to allow full weight-bearing for activities required for daily livingAims
Methods
Aims. Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of
Joint registries classify all further arthroplasty procedures to a knee with an existing partial arthroplasty as revision surgery, regardless of the actual procedure performed. Relatively minor procedures, including bearing exchanges, are classified in the same way as major operations requiring augments and stems. A new classification system is proposed to acknowledge and describe the detail of these procedures, which has implications for risk, recovery, and health economics. Classification categories were proposed by a surgical consensus group, then ranked by patients, according to perceived invasiveness and implications for recovery. In round one, 26 revision cases were classified by the consensus group. Results were tested for inter-rater reliability. In round two, four additional cases were added for clarity. Round three repeated the survey one month later, subject to inter- and intrarater reliability testing. In round four, five additional expert partial knee arthroplasty surgeons were asked to classify the 30 cases according to the proposed revision partial knee classification (RPKC) system.Aims
Methods
Aims. In contrast to operations performed for other fractures, there is a high incidence rate of surgical site infection (SSI) post-open reduction and internal fixation (ORIF) done for
The proportion of arthroplasties performed in the ambulatory setting has increased considerably. However, there are concerns whether same-day discharge may increase the risk of complications. The aim of this study was to compare 90-day outcomes between inpatient arthroplasties and outpatient arthroplasties performed at an ambulatory surgery centre (ASC), and determine whether there is a learning curve associated with performing athroplasties in an ASC. Among a single-surgeon cohort of 970 patients who underwent arthroplasty at an ASC, 854 (88.0%) were matched one-to-one with inpatients based on age, sex, American Society of Anesthesiologists (ASA) grade, BMI, and procedure (105 could not be adequately matched and 11 lacked 90-day follow-up). The cohort included 281 total hip arthroplasties (THAs) (32.9%), 267 unicompartmental knee arthroplasties (31.3%), 242 primary total knee arthroplasties (TKAs) (28.3%), 60 hip resurfacings (7.0%), two revision THAs (0.3%), and two revision TKAs (0.3%). Outcomes included readmissions, reoperations, visits to the emergency department, unplanned clinic visits, and complications.Aims
Methods
Uncemented mobile bearing designs in medial unicompartmental knee arthroplasty (UKA) have seen an increase over the last decade. However, there are a lack of large-scale studies comparing survivorship of these specific designs to commonly used cemented mobile and fixed bearing designs. The aim of this study was to evaluate the survivorship of these designs. A total of 21,610 medial UKAs from 2007 to 2018 were selected from the Dutch Arthroplasty Register. Multivariate Cox regression analyses were used to compare uncemented mobile bearings with cemented mobile and fixed bearings. Adjustments were made for patient and surgical factors, with their interactions being considered. Reasons and type of revision in the first two years after surgery were assessed.Aims
Methods
Antibiotic resistance represents a threat to human health. It has been suggested that by 2050, antibiotic-resistant infections could cause ten million deaths each year. In orthopaedics, many patients undergoing surgery suffer from complications resulting from implant-associated infection. In these circumstances secondary surgery is usually required and chronic and/or relapsing disease may ensue. The development of effective treatments for antibiotic-resistant infections is needed. Recent evidence shows that bacteriophage (phages; viruses that infect bacteria) therapy may represent a viable and successful solution. In this review, a brief description of bone and joint infection and the nature of bacteriophages is presented, as well as a summary of our current knowledge on the use of bacteriophages in the treatment of bacterial infections. We present contemporary published in vitro and in vivo data as well as data from clinical trials, as they relate to bone and joint infections. We discuss the potential use of bacteriophage therapy in orthopaedic infections. This area of research is beginning to reveal successful results, but mostly in nonorthopaedic fields. We believe that bacteriophage therapy has potential therapeutic value for implant-associated infections in orthopaedics. Cite this article:
Aims. Cementless unicompartmental knee arthroplasty (UKA) has advantages over cemented UKA, including improved fixation, but has a higher risk of
Aims.
Aims.
Limited evidence is available on mid-term outcomes of robotic-arm assisted (RA) partial knee arthroplasty (PKA). Therefore, the purpose of this study was to evaluate mid-term survivorship, modes of failure, and patient-reported outcomes of RA PKA. A retrospective review of patients who underwent RA PKA between June 2007 and August 2016 was performed. Patients received a fixed-bearing medial or lateral unicompartmental knee arthroplasty (UKA), patellofemoral arthroplasty (PFA), or bicompartmental knee arthroplasty (BiKA; PFA plus medial UKA). All patients completed a questionnaire regarding revision surgery, reoperations, and level of satisfaction. Knee Injury and Osteoarthritis Outcome Scores (KOOS) were assessed using the KOOS for Joint Replacement Junior survey.Aims
Methods
Aims. The aim of this study was to determine the trajectory of recovery following fixation of
Objectives. CT-based three-column classification (TCC) has been widely used in the treatment of
The aim of this study was to evaluate the functional outcome in patients undergoing implant removal (IR) after fracture fixation below the level of the knee. All adult patients (18 to 75 years) undergoing IR after fracture fixation below the level of the knee between November 2014 and September 2016 were included as part of the WIFI (Wound Infections Following Implant Removal Below the Knee) trial, performed in 17 teaching hospitals and two university hospitals in The Netherlands. In this multicentre prospective cohort, the primary outcome was the difference in functional status before and after IR, measured by the Lower Extremity Functional Scale (LEFS), with a minimal clinically important difference of nine points.Aims
Patients and Methods
The aim of this study was to utilize a national paediatric inpatient database to determine whether obesity influences the operative management and inpatient outcomes of paediatric limb fractures. The Kids’ Inpatient Database (KID) was used to evaluate children between birth and 17 years of age, from 1997 and 2012, who had undergone open and closed treatment of humeral, radial and ulna, femoral, tibial, and ankle fractures. Demographics, hospital charges, lengths of stay (LOS), and complications were analyzed.Aims
Patients and Methods
Opening wedge high tibial osteotomy (HTO) is an established surgical procedure for the treatment of early-stage knee arthritis. Other than infection, the majority of complications are related to mechanical factors – in particular, stimulation of healing at the osteotomy site. This study used finite element (FE) analysis to investigate the effect of plate design and bridging span on interfragmentary movement (IFM) and the influence of fracture healing on plate stress and potential failure. A 10° opening wedge HTO was created in a composite tibia. Imaging and strain gauge data were used to create and validate FE models. Models of an intact tibia and a tibia implanted with a custom HTO plate using two different bridging spans were validated against experimental data. Physiological muscle forces and different stages of osteotomy gap healing simulating up to six weeks postoperatively were then incorporated. Predictions of plate stress and IFM for the custom plate were compared against predictions for an industry standard plate (TomoFix).Objectives
Materials and Methods
The aim of this study was to evaluate near-infrared spectroscopy
(NIRS) as a continuous, non-invasive monitor for acute compartment
syndrome (ACS). NIRS sensors were placed on 86 patients with, and 23 without
(controls), severe leg injury. NIRS values were recorded for up
to 48 hours. Longitudinal data were analyzed using summary and graphical
methods, bivariate comparisons, and multivariable multilevel modelling.Aims
Patients and Methods
The primary stability of the cementless Oxford Unicompartmental Knee Replacement (OUKR) relies on interference fit (or press fit). Insufficient interference may cause implant loosening, whilst excessive interference could cause bone damage and fracture. The aim of this study was to identify the optimal interference fit by measuring the force required to seat the tibial component of the cementless OUKR (push-in force) and the force required to remove the component (pull-out force). Six cementless OUKR tibial components were implanted in 12 new slots prepared on blocks of solid polyurethane foam (20 pounds per cubic foot (PCF), Sawbones, Malmo, Sweden) with a range of interference of 0.1 mm to 1.9 mm using a Dartec materials testing machine HC10 (Zwick Ltd, Herefordshire, United Kingdom) . The experiment was repeated with cellular polyurethane foam (15 PCF), which is a more porous analogue for trabecular bone.Objectives
Materials and Methods
Diabetes mellitus (DM) is known to impair fracture healing. Increasing evidence suggests that some microRNA (miRNA) is involved in the pathophysiology of diabetes and its complications. We hypothesized that the functions of miRNA and changes to their patterns of expression may be implicated in the pathogenesis of impaired fracture healing in DM. Closed transverse fractures were created in the femurs of 116 rats, with half assigned to the DM group and half assigned to the control group. Rats with DM were induced by a single intraperitoneal injection of streptozotocin. At post-fracture days five, seven, 11, 14, 21, and 28, miRNA was extracted from the newly generated tissue at the fracture site. Microarray analysis was performed with miRNA samples from each group on post-fracture days five and 11. For further analysis, real-time polymerase chain reaction (PCR) analysis was performed at each timepoint.Objectives
Methods
The continual cycle of bone formation and resorption
is carried out by osteoblasts, osteocytes, and osteoclasts under
the direction of the bone-signaling pathway. In certain situations
the host cycle of bone repair is insufficient and requires the assistance
of bone grafts and their substitutes. The fundamental properties
of a bone graft are osteoconduction, osteoinduction, osteogenesis,
and structural support. Options for bone grafting include autogenous
and allograft bone and the various isolated or combined substitutes
of calcium sulphate, calcium phosphate, tricalcium phosphate, and
coralline hydroxyapatite. Not all bone grafts will have the same
properties. As a result, understanding the requirements of the clinical
situation and specific properties of the various types of bone grafts
is necessary to identify the ideal graft. We present a review of
the bone repair process and properties of bone grafts and their
substitutes to help guide the clinician in the decision making process. Cite this article:
The December 2015 Trauma Roundup. 360 . looks at: Delay to surgery in hip fracture; Hexapod fixators in the management of hypertrophic tibial nonunions; Thromboembolism after nailing pathological
This study aimed to determine the long-term functional,
clinical and radiological outcomes in patients with Schatzker IV
to VI fractures of the tibial plateau treated with an Ilizarov frame.
Clinical, functional and radiological assessment was carried out
at a minimum of one year post-operatively. A cohort of 105 patients
(62 men, 43 women) with a mean age of 49 years (15 to 87) and a
mean follow-up of 7.8 years (1 to 19) were reviewed. There were
18 type IV, 10 type V and 77 type VI fractures. All fractures united
with a mean time to union of 20.1 weeks (10.6 to 42.3). No patient
developed a deep infection. The median range of movement (ROM) of
the knee was 110o and the median Iowa score was 85. Our study demonstrates good long-term functional outcome with
no deep infection; spanning the knee had no detrimental effect on
the ROM or functional outcome. High-energy fractures of the tibial plateau may be treated effectively
with a fine wire Ilizarov fixator. Cite this article:
Primary total knee arthroplasty (TKA) is a reliable
procedure with reproducible long-term results. Nevertheless, there
are conditions related to the type of patient or local conditions
of the knee that can make it a difficult procedure. The most common
scenarios that make it difficult are discussed in this review. These
include patients with many previous operations and incisions, and
those with severe coronal deformities, genu recurvatum, a stiff knee,
extra-articular deformities and those who have previously undergone
osteotomy around the knee and those with chronic dislocation of
the patella. Each condition is analysed according to the characteristics of
the patient, the pre-operative planning and the reported outcomes. When approaching the difficult primary TKA surgeons should use
a systematic approach, which begins with the review of the existing
literature for each specific clinical situation. Cite this article:
A total of 22 patients with a tibial avulsion
fracture involving the insertion of the posterior cruciate ligament
(PCL) with grade II or III posterior laxity were reduced and fixed
arthroscopically using routine anterior and double posteromedial
portals. A double-strand Ethibond suture was inserted into the joint
and wrapped around the PCL from anterior to posterior to secure
the ligament above the avulsed bony fragment. Two tibial bone tunnels
were created using the PCL reconstruction guide, aiming at the medial
and lateral borders of the tibial bed. The ends of the suture were
pulled out through the bone tunnels and tied over the tibial cortex
between the openings of the tunnels to reduce and secure the bony
fragment. Satisfactory reduction of the fracture was checked arthroscopically and
radiographically. The patients were followed-up for a mean of 24.5 months (19 to
28). Bone union occurred six weeks post-operatively. At final follow-up,
all patients had a negative posterior drawer test and a full range
of movement. KT-1000 arthrometer examination showed that the mean
post-operative side-to-side difference improved from 10.9 mm (standard
deviation ( We conclude that this technique is convenient, reliable and minimally
invasive and successfully restores the stability and function of
the knee. Cite this article:
The August 2015 Trauma Roundup. 360 . looks at: Thromboprophylaxis not required in lower limb fractures; Subclinical thyroid dysfunction and fracture risk: moving the boundaries in fracture; Posterior wall fractures refined; Neurological injury and acetabular fracture surgery; Posterior tibial plateau fixation;
A total of 20 patients with a depressed fracture
of the lateral tibial plateau (Schatzker II or III) who would undergo open
reduction and internal fixation were randomised to have the metaphyseal
void in the bone filled with either porous titanium granules or
autograft bone. Radiographs were undertaken within one week, after
six weeks, three months, six months, and after 12 months. The primary outcome measure was recurrent depression of the joint
surface: a secondary outcome was the duration of surgery. The risk of recurrent depression of the joint surface was lower
(p <
0.001) and the operating time less (p <
0.002) when titanium
granules were used. The indication is that it is therefore beneficial to use porous
titanium granules than autograft bone to fill the void created by
reducing a depressed fracture of the lateral tibial plateau. There
is no donor site morbidity, the operating time is shorter and the
risk of recurrent depression of the articular surface is less. Cite this article:
Radiological evidence of post-traumatic osteoarthritis
(PTOA) after fracture of the tibial plateau is common but end-stage arthritis
which requires total knee arthroplasty is much rarer. The aim of this study was to examine the indications for, and
outcomes of, total knee arthroplasty after fracture of the tibial
plateau and to compare this with an age and gender-matched cohort
of TKAs carried out for primary osteoarthritis. Between 1997 and 2011, 31 consecutive patients (23 women, eight
men) with a mean age of 65 years (40 to 89) underwent TKA at a mean
of 24 months (2 to 124) after a fracture of the tibial plateau.
Of these, 24 had undergone ORIF and seven had been treated non-operatively.
Patients were assessed pre-operatively and at 6, 12 and >
60 months
using the Short Form-12, Oxford Knee Score and a patient satisfaction
score. Patients with instability or nonunion needed total knee arthroplasty
earlier (14 and 13.3 months post-injury) than those with intra-articular
malunion (50 months, p <
0.001). Primary cruciate-retaining implants
were used in 27 (87%) patients. Complication rates were higher in
the PTOA cohort and included wound complications (13% Total knee arthroplasty undertaken after fracture of the tibial
plateau has a higher rate of complications than that undertaken
for primary osteoarthritis, but patient-reported outcomes and satisfaction
are comparable. Cite this article:
The April 2015 Trauma Roundup360 looks at: Negative presure wound therapy in open tibial fractures; Priority-driven approach to pelvic injuries; Early surgery essential in hip fracture management; Sheer fractures to the posteromedial plateau; Fasciotomy closure under the spotlight; Why do patients die from hip fracture?; Acetabular fractures down the line; Biomechanics of femoral neck fractures reviewed
Fresh-frozen allograft bone is frequently used
in orthopaedic surgery. We investigated the incidence of allograft-related
infection and analysed the outcomes of recipients of bacterial culture-positive
allografts from our single-institute bone bank during bone transplantation.
The fresh-frozen allografts were harvested in a strict sterile environment
during total joint arthroplasty surgery and immediately stored in
a freezer at -78º to -68º C after packing. Between January 2007
and December 2012, 2024 patients received 2083 allografts with a
minimum of 12 months of follow-up. The overall allograft-associated
infection rate was 1.2% (24/2024). Swab cultures of 2083 allografts
taken before implantation revealed 21 (1.0%) positive findings.
The 21 recipients were given various antibiotics at the individual
orthopaedic surgeon’s discretion. At the latest follow-up, none
of these 21 recipients displayed clinical signs of infection following
treatment. Based on these findings, we conclude that an incidental positive
culture finding for allografts does not correlate with subsequent
surgical site infection. Additional prolonged post-operative antibiotic
therapy may not be necessary for recipients of fresh-frozen bone
allograft with positive culture findings. Cite this article:
The December 2014 Trauma Roundup. 360 . looks at: infection and temporising external fixation; Vitamin C in distal radial fractures; DRAFFT: Cheap and cheerful Kirschner wires win out; femoral neck fractures not as stable as they might be; displaced sacral fractures give high morbidity and mortality; sanders and calcaneal fractures: a 20-year experience; bleeding and pelvic fractures; optimising timing for acetabular fractures; and
A retrospective review was performed of patients
undergoing primary cementless total knee replacement (TKR) using
porous tantalum performed by a group of surgical trainees. Clinical
and radiological follow-up involved 79 females and 26 males encompassing
115 knees. The mean age was 66.9 years (36 to 85). Mean follow-up
was 7 years (2 to 11). Tibial and patellar components were porous
tantalum monoblock implants, and femoral components were posterior
stabilised (PS) in design with cobalt–chromium fibre mesh. Radiological
assessments were made for implant positioning, alignment, radiolucencies,
lysis, and loosening. There was 95.7% survival of implants. There
was no radiological evidence of loosening and no osteolysis found.
No revisions were performed for aseptic loosening. Average tibial
component alignment was 1.4° of varus (4°of valgus to 9° varus),
and 6.2° (3° anterior to 15° posterior) of posterior slope. Mean
femoral component alignment was 6.6° (1° to 11°) of valgus. Mean tibiofemoral
alignment was 5.6° of valgus (7° varus to 16° valgus). Patellar
tilt was a mean of 2.4° lateral (5° medial to 28° lateral). Patient
satisfaction with improvement in pain was 91%. Cementless TKR incorporating
porous tantalum yielded good clinical and radiological outcomes
at a mean of follow-up of seven-years. Cite this article:
Unstable bicondylar tibial plateau fractures
are rare and there is little guidance in the literature as to the
best form of treatment. We examined the short- to medium-term outcome
of this injury in a consecutive series of patients presenting to
two trauma centres. Between December 2005 and May 2010, a total
of 55 fractures in 54 patients were treated by fixation, 34 with
peri-articular locking plates and 21 with limited access direct
internal fixation in combination with circular external fixation
using a Taylor Spatial Frame (TSF). At a minimum of one year post-operatively,
patient-reported outcome measures including the WOMAC index and
SF-36 scores showed functional deficits, although there was no significant
difference between the two forms of treatment. Despite low outcome scores,
patients were generally satisfied with the outcome. We achieved
good clinical and radiological outcomes, with low rates of complication.
In total, only three patients (5%) had collapse of the joint of
>
4 mm, and metaphysis to diaphysis angulation of greater than 5º,
and five patients (9%) with displacement of >
4 mm. All patients
in our study went on to achieve full union. This study highlights the serious nature of this injury and generally
poor patient-reported outcome measures following surgery, despite
treatment by experienced surgeons using modern surgical techniques.
Our findings suggest that treatment of complex bicondylar tibial
plateau fractures with either a locking plate or a TSF gives similar
clinical and radiological outcomes. Cite this article:
The April 2014 Knee Roundup. 360 . looks at: mobile compression as good as chemical thromboprophylaxis; patellar injury with MIS knee surgery;
The February 2014 Trauma Roundup360 looks at: predicting nonunion; compartment Syndrome; octogenarian RTCs; does HIV status affect decision making in open tibial fractures?; flap timing and related complications; proximal humeral fractures under the spotlight; restoration of hip architecture with bipolar hemiarthroplasty in the elderly; and short
Bicondylar
The period of post-operative treatment before surgical wounds
are completely closed remains a key window, during which one can
apply new technologies that can minimise complications. One such
technology is the use of negative pressure wound therapy to manage
and accelerate healing of the closed incisional wound (incisional
NPWT). We undertook a literature review of this emerging indication
to identify evidence within orthopaedic surgery and other surgical
disciplines. Literature that supports our current understanding
of the mechanisms of action was also reviewed in detail. Objectives
Methods
The outcome of high tibial osteotomy (HTO) deteriorates
with time, and additional procedures may be required. The aim of
this study was to compare the clinical and radiological outcomes
between unicompartmental knee replacement (UKR) and total knee replacement
(TKR) after HTO as well as after primary UKR. A total of 63 patients (63
knees) were studied retrospectively and divided into three groups:
UKR after HTO (group A; n = 22), TKR after HTO (group B; n = 18)
and primary UKR (group C; n = 22). The Oxford knee score (OKS),
Knee Society score (KSS), hip–knee–ankle angles, mechanical axis
and patellar height were evaluated pre- and post-operatively. At
a mean of 64 months (19 to 180) post-operatively the mean OKS was
43.8 (33 to 49), 43.3 (30 to 48) and 42.5 (29 to 48) for groups
A, B and C, respectively (p = 0.73). The mean KSS knee score was
88.8 (54 to 100), 88.11 (51 to 100) and 85.3 (45 to 100) for groups
A, B and C, respectively (p = 0.65), and the mean KSS function score
was 85.0 (50 to 100) in group A, 85.8 (20 to 100) in group B and
79.3 (50 to 100) in group C (p = 0.48). Radiologically the results
were comparable for all groups except for patellar height, with
a higher incidence of patella infra following a previous HTO (p
= 0.02). Cite this article:
The August 2013 Trauma Roundup. 360 . looks at: reverse oblique fractures do better with a cephalomedullary device; locking screws confer no advantage in
We reviewed 59 bone graft substitutes marketed
by 17 companies currently available for implantation in the United Kingdom,
with the aim of assessing the peer-reviewed literature to facilitate
informed decision-making regarding their use in clinical practice.
After critical analysis of the literature, only 22 products (37%)
had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita),
Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question
the need for so many different products, especially with limited
published clinical evidence for their efficacy, and conclude that
there is a considerable need for further prospective randomised
trials to facilitate informed decision-making with regard to the
use of current and future bone graft substitutes in clinical practice. Cite this article:
The lateral compartment is predominantly affected
in approximately 10% of patients with osteoarthritis of the knee. The
anatomy, kinematics and loading during movement differ considerably
between medial and lateral compartments of the knee. This in the
main explains the relative protection of the lateral compartment
compared with the medial compartment in the development of osteoarthritis.
The aetiology of lateral compartment osteoarthritis can be idiopathic,
usually affecting the femur, or secondary to trauma commonly affecting
the tibia. Surgical management of lateral compartment osteoarthritis
can include osteotomy, unicompartmental knee replacement and total
knee replacement. This review discusses the biomechanics, pathogenesis
and development of lateral compartment osteoarthritis and its management. Cite this article:
We report a prospective single-blind controlled
study of the incidence of early wound infection after internal fixation for
trauma in 609 patients, of whom 132 were HIV-positive. Wounds were
assessed for healing using the ASEPSIS score. There was no significant
difference in the rate of infection between HIV-positive and HIV-negative
patients undergoing clean surgery (4.2% We conclude that clean implant surgery in HIV-positive patients
is safe, with no need for additional prophylaxis.
This review considers the surgical treatment
of displaced fractures involving the knee in elderly, osteoporotic patients.
The goals of treatment include pain control, early mobilisation,
avoidance of complications and minimising the need for further surgery.
Open reduction and internal fixation (ORIF) frequently results in
loss of reduction, which can result in post-traumatic arthritis
and the occasional conversion to total knee replacement (TKR). TKR
after failed internal fixation is challenging, with modest functional
outcomes and high complication rates. TKR undertaken as treatment
of the initial fracture has better results to late TKR, but does
not match the outcome of primary TKR without complications. Given
the relatively infrequent need for late TKR following failed fixation,
ORIF is the preferred management for most cases. Early TKR can be
considered for those patients with pre-existing arthritis, bicondylar
femoral fractures, those who would be unable to comply with weight-bearing restrictions,
or where a single definitive procedure is required.
Medium-term survivorship of the Oxford phase
3 unicompartmental knee replacement (UKR) has not yet been established
in an Asian population. We prospectively evaluated the outcome of
400 phase 3 Oxford UKRs in 320 Korean patients with a mean age at
the time of operation of 69 years (48 to 82). The mean follow-up
was 5.2 years (1 to 10). Clinical and radiological assessment was
carried out pre- and post-operatively. At five years, the mean Knee
Society knee and functional scores had increased significantly from
56.2 (30 to 91) pre-operatively to 87.2 (59 to 98) (p = 0.034) and
from 59.2 (30 to 93) to 88.3 (50 to 100) (p = 0.021), respectively.
The Oxford knee score increased from a mean of 25.8 (12 to 39) pre-operatively
to 39.8 (25 to 58) at five years (p = 0.038). The ten-year survival
rate was 94% (95% confidence interval 90.1 to 98.0). A total of
14 UKRs (3.5%) required revision. The most common reason for revision
was dislocation of the bearing in 12 (3%). Conversion to a total
knee replacement was required in two patients who developed osteoarthritis
of the lateral compartment. This is the largest published series of UKR in Korean patients.
It shows that the mid-term results after a minimally invasive Oxford
phase 3 UKR can yield satisfactory clinical and functional results
in this group of patients.
We investigated the stability of seven Schatzker type II fractures of the lateral tibial plateau treated by subchondral screws and a buttress plate followed by immediate partial weight-bearing. In order to assess the stability of the fracture, weight-bearing inducible displacements of the fracture fragments and their migration over a one-year period were measured by differentially loaded radiostereometric analysis and standard radiostereometric analysis, respectively. The mean inducible craniocaudal fracture fragment displacements measured −0.30 mm (−0.73 to 0.02) at two weeks and 0.00 mm (−0.12 to 0.15) at 52 weeks. All inducible displacements were elastic in nature under all loads at each examination during follow-up. At one year, the mean craniocaudal migration of the fracture fragments was −0.34 mm (−1.64 to 1.51). Using radiostereometric methods, this case series has shown that in the Schatzker type II fractures investigated, internal fixation with subchondral screws and a buttress plate provided adequate stability to allow immediate post-operative partial weight-bearing, without harmful consequences.
The Canadian Orthopaedic Trauma Society was started in an endeavour to answer the difficult problem of obtaining enough patients to perform top-quality research into fractures. By maintaining a high standard, including randomised study design, inclusivity, open discussion among surgeons and excellent long-term follow-up, this group has become a leader in the orthopaedic research community. This annotation describes the short history, important components and spirit necessary to build a research community or team which will function well despite the difficult research environment facing individual surgeons.
Fluoronavigation is an image-guided technology which uses intra-operative fluoroscopic images taken under a real-time tracking system and registration to guide surgical procedures. With the skeleton and the instrument registered, guidance under an optical tracking system is possible, allowing fixation of the fracture and insertion of an implant. This technology helps to minimise exposure to x-rays, providing multiplanar views for monitoring and accurate positioning of implants. It allows real-time interactive quantitative data for decision-making and expands the application of minimally invasive surgery. In orthopaedic trauma its use can be further enhanced by combining newer imaging technologies such as intra-operative three-dimensional fluoroscopy and optical image guidance, new advances in software for fracture reduction, and new tracking mechanisms using electromagnetic technology. The major obstacles for general and wider applications are the inability to track individual fracture fragments, no navigated real-time fracture reduction, and the lack of an objective assessment method for cost-effectiveness. We believe that its application will go beyond the operating theatre and cover all aspects of patient management, from pre-operative planning to intra-operative guidance and postoperative rehabilitation.
We assessed the reliability, accuracy and variability of closed-wedge high tibial osteotomy (HTO) using computer-assisted surgery compared to the conventional technique. A total of 50 closed-wedge HTO procedures were performed using the navigation system, and compared with 50 HTOs that had been performed with the conventional technique. In the navigation group, the mean mechanical axis prior to osteotomy was varus 8.2°, and the mean mechanical axis following fixation was valgus 3.6°. On the radiographs the mean pre-operative mechanical axis was varus 7.3°, and the mean post-operative mechanical axis was valgus 2.1°. There was a positive correlation between the measured data taken under navigation and by radiographs (r >
0.3, p <
0.05). The mean correction angle was significantly more accurate in the navigation group (p <
0.002). The variability of the correction was significantly lower in the navigation group (2.3°
Between 1998 and 2007, 22 patients with fractures of the scapula had operative treatment more than three weeks after injury. The indications for operation included displaced intra-articular fractures, medialisation of the glenohumeral joint, angular deformity, or displaced double lesions of the superior shoulder suspensory complex. Radiological and functional outcomes were obtained for 16 of 22 patients. Disabilities of the Arm, Shoulder, Hand (DASH) and Short form-36 scores were collected for 14 patients who were operated on after March 2002. The mean delay from injury to surgery was 30 days (21 to 57). The mean follow-up was for 27 months (12 to 72). At the last review the mean DASH score was 14 (0 to 41). Of the 16 patients with follow-up, 13 returned to their previous employment and recreational activities without restrictions. No wound complications, infection or nonunion occurred. Malunion of the scapula can be prevented by surgical treatment of fractures in patients with delayed presentation. Surgery is safe, effective, and gives acceptable functional results.
We have compared the outcomes of the use of external fixation devices for spanning or sparing the ankle joint in the treatment of fractures of the tibial plafond, focusing on the complications and the rates of healing. We have devised a scoring system for the quality of reporting of clinical outcomes, to determine the reliability of the results. We conducted a search of publications in English between 1990 and 2006 using the Pubmed search engine. The key words used were pilon, pylon, plafond fractures, external fixation. A total of 15 articles, which included 465 fractures, were eligible for final evaluation. There were no statistically significant differences between spanning and sparing fixation systems regarding the rates of infection, nonunion, and the time to union. Patients treated with spanning frames had significantly greater incidence of malunion compared with patients treated with sparing frames. In both groups, the outcome reporting score was very low; 60% of reports involving infection, nonunion or malunion scored 0 points.
Patellofemoral joint degeneration is often considered a contraindication to medial unicompartmental knee replacement. We examined the validity of this preconception using information gathered prospectively on the intra-operative status of the patellofemoral joint in 824 knees in 793 consecutive patients who underwent Oxford unicondylar knee replacement for anteromedial osteoarthritis. All operations were performed between January 1998 and September 2005. A five-point grading system classified degeneration of the patellofemoral joint from none to full-thickness cartilage loss. A subclassification of the presence or absence of any full-thickness cartilage loss was subsequently performed to test selected hypotheses. Outcome was evaluated independently by physiotherapists using the Oxford and the American Knee Society Scores with a minimum follow-up of one year. Full-thickness cartilage loss on the trochlear surface was observed in 100 of 785 knees (13%), on the medial facet of the patella in 69 of 782 knees (9%) and on the lateral facet in 29 of 784 knees (4%). Full-thickness cartilage loss at any location was seen in 128 knees (16%) and did not produce a significantly worse outcome than those with a normal or near-normal joint surface. The severity of the degeneration at any of the intra-articular locations also had no influence on outcome. We concluded that, provided there is not bone loss and grooving of the lateral facet, damage to the articular cartilage of the patellofemoral joint to the extent of full-thickness cartilage loss is not a contraindication to the Oxford mobile-bearing unicompartmental knee replacement.
We examined 36 consecutive patients with closed
We report the results of a three-year study of bifocal fractures of the tibia and fibula, excluding segmental shaft fractures. In our whole series, these formed 4.7% of all tibial diaphyseal fractures. We describe three groups: bifocal fractures of both the proximal and the distal joint surfaces, fractures of the shaft and
We report the use of combined anterior and posterior approaches for the reduction and fixation of complex
We evaluated the long-term results of 109
Sixteen consecutive patients with