Aims. Massive endoprostheses rely on extra-cortical bone bridging (ECBB)
to enhance fixation. The aim of this study was to investigate the
role of selective laser sintered (SLS) porous collars in augmenting
the osseointegration of these prostheses. Materials and Methods. The two novel designs of porous SLS collars, one with small pores
(Ø700 μm, SP) and one with large pores (Ø1500 μm, LP), were compared
in an ovine tibial diaphyseal model. Osseointegration of these collars
was compared with that of a clinically used solid, grooved design
(G). At six months post-operatively, the ovine tibias were retrieved and
underwent radiological and histological analysis. Results. Porous collars provided a significantly greater surface (p <
0.001) for the ingrowth of bone than the standard grooved design.
Significantly greater extracortical
The current indications for functional restoration
of extension of the knee following quadriceps resection or loss require
reappraisal. The contribution of
Orthopaedic and reconstructive surgeons are faced with large defects after the resection of malignant tumours of the sacrum. Spinopelvic reconstruction is advocated for resections above the level of the S1 neural foramina or involving the sacroiliac joint. Fixation may be augmented with either free vascularized fibular flaps (FVFs) or allograft fibular struts (AFSs) in a cathedral style. However, there are no studies comparing these reconstructive techniques. We reviewed 44 patients (23 female, 21 male) with a mean age of 40 years (SD 17), who underwent en bloc sacrectomy for a malignant tumour of the sacrum with a reconstruction using a total (n = 20), subtotal (n = 2), or hemicathedral (n = 25) technique. The reconstructions were supplemented with a FVF in 25 patients (57%) and an AFS in 19 patients (43%). The mean length of the strut graft was 13 cm (SD 4). The mean follow-up was seven years (SD 5).Aims
Methods
We describe a consecutive series of five patients with bone or soft-tissue sarcomas of the elbow and intra-articular extension treated by complex soft tissue, allograft bone and prosthetic joint replacement after wide extra-articular en bloc excision. All had a
Iliosacral sarcoma resections have been shown to have high rates of local recurrence (LR) and poor overall survival. There is also no universal classification for the resection of pelvic sarcomas invading the sacrum. This study proposes a novel classification system and analyzes the survival and risk of recurrence, when using this system. This is a retrospective analysis of 151 patients (with median follow-up in survivors of 44 months (interquartile range 12 to 77)) who underwent hemipelvectomy with iliosacral resection at a single centre between 2007 and 2019. The proposed classification differentiates the extent of iliosacral resection and defines types S1 to S6 (S1 resection medial and parallel to the sacroiliac joint, S2 resection through the ipsilateral sacral lateral mass to the neuroforamina, S3 resection through the ipsilateral neuroforamina, S4 resection through ipsilateral the spinal canal, and S5 and S6 contralateral sacral resections). Descriptive statistics and the chi-squared test were used for categorical variables, and the Kaplan-Meier survival analysis were performed.Aims
Methods
The aim of this study was to report the results of three forms of reconstruction for patients with a ditsl tibial bone tumour: an intercalary resection and reconstruction, an osteoarticular reconstruction, and arthrodesis of the ankle. A total of 73 patients with a median age of 19 years (interquartile range (IQR) 14 to 36) were included in this retrospective, multicentre study.Aims
Methods
The use of frozen tumour-bearing autograft combined with a vascularized fibular graft (VFG) represents a new technique for biological reconstruction of massive bone defect. We have compared the clinical outcomes between this technique and Capanna reconstruction. From June 2011 to January 2016 a retrospective study was carried out of patients with primary osteosarcoma of lower limbs who underwent combined biological intercalary reconstruction. Patients were categorized into two groups based on the reconstructive technique: frozen tumour-bearing autograft combined with concurrent VFG (Group 1) and the Capanna method (Group 2). Demographics, operating procedures, oncological outcomes, graft union, limb function, and postoperative complications were compared.Aims
Methods
The aim of this study was to describe the use of 3D-printed sacral endoprostheses to reconstruct the pelvic ring and re-establish spinopelvic stability after total We retrospectively reviewed 32 patients who underwent TES in our hospital between January 2015 and December 2017. We divided the patients into three groups on the basis of the method of reconstruction: an endoprosthesis group (n = 10); a combined reconstruction group (n = 14), who underwent non-endoprosthetic combined reconstruction, including anterior spinal column fixation; and a spinopelvic fixation (SPF) group (n = 8), who underwent only SPF. Spinopelvic stability, implant survival (IS), intraoperative haemorrhage rate, and perioperative complication rate in the endoprosthesis group were documented and compared with those of other two groups.Aims
Patients and Methods
The sacrum is frequently invaded by a pelvic tumour. The aim
of this study was to review our experience of treating this group
of patients and to identify the feasibility of a new surgical classification
in the management of these tumours. We reviewed 141 patients who, between 2005 and 2014, had undergone
surgical excision of a pelvic tumour with invasion of the sacrum. In a new classification, pelvisacral (Ps) I, II, and III resections
refer to a sagittal osteotomy through the ipsilateral wing of the
sacrum, through the sacral midline, or lateral to the contralateral
sacral foramina, respectively. A Ps a resection describes a pelvic
osteotomy through the ilium and a Ps b resection describes a concurrent
resection of the acetabulum with osteotomies performed through the
pubis and ischium or the pubic symphysis. Within each type, surgical
approaches were standardized to guide resection of the tumour.Aims
Patients and Methods
The aims of this retrospective study were to report the feasibility
of using 3D-printing technology for patients with a pelvic tumour
who underwent reconstruction. A total of 35 patients underwent resection of a pelvic tumour
and reconstruction using 3D-printed endoprostheses between September
2013 and December 2015. According to Enneking’s classification of
bone defects, there were three Type I lesions, 12 Type II+III lesions,
five Type I+II lesions, two Type I+II+III lesions, ten type I+II+IV
lesions and three type I+II+III+IV lesions. A total of three patients
underwent reconstruction using an iliac prosthesis, 12 using a standard
hemipelvic prosthesis and 20 using a screw-rod connected hemipelvic
prosthesis.Aims
Patients and Methods
After intercalary resection of a bone tumour from the femur,
reconstruction with a vascularized fibular graft (VFG) and massive
allograft is considered a reliable method of treatment. However,
little is known about the long-term outcome of this procedure. The
aims of this study were to determine whether the morbidity of this
procedure was comparable to that of other reconstructive techniques,
if it was possible to achieve a satisfactory functional result, and
whether biological reconstruction with a VFG and massive allograft
could achieve a durable, long-lasting reconstruction. A total of 23 patients with a mean age of 16 years (five to 40)
who had undergone resection of an intercalary bone tumour of the
femur and reconstruction with a VFG and allograft were reviewed
clinically and radiologically. The mean follow-up was 141 months
(24 to 313). The mean length of the fibular graft was 18 cm (12 to
29). Full weight-bearing without a brace was allowed after a mean
of 13 months (seven to 26).Aims
Patients and Methods
Free vascularised fibular grafting has been used for the treatment
of large bony defects for more than 40 years. However, there is
little information about the risk factors for failure and whether
newer locking techniques of fixation improve the rates of union.
The purpose of this study was to compare the rates of union of free
fibular grafts fixed with locking and traditional techniques, and
to quantify the risk factors for nonunion and failure. A retrospective review involved 134 consecutive procedures over
a period of 20 years. Of these, 25 were excluded leaving 109 patients
in the study. There were 66 men and 43 women, with a mean age of
33 years (5 to 78). Most (62) were performed for oncological indications,
and the most common site (52) was the lower limb. Rate of union
was estimated using the Kaplan-Meier method and risk factors for
nonunion were assessed using Cox regression. All patients were followed
up for at least one year.Aims
Patients and Methods
The aim of the study was to compare measures of the quality of
life (QOL) after resection of a chordoma of the mobile spine with
the national averages in the United States and to assess which factors
influenced the QOL, symptoms of anxiety and depression, and coping
with pain post-operatively in these patients. A total of 48 consecutive patients who underwent resection of
a primary or recurrent chordoma of the mobile spine between 2000
and 2015 were included. A total of 34 patients completed a survey
at least 12 months post-operatively. The primary outcome was the
EuroQol-5 Dimensions (EQ-5D-3L) questionnaire. Secondary outcomes were
the Patient-Reported Outcome Measurement Information System (PROMIS)
anxiety, depression and pain interference questionnaires. Data which
were recorded included the indication for surgery, the region of
the tumour, the number of levels resected, the status of the surgical
margins, re-operations, complications, neurological deficit, length
of stay in hospital and rate of re-admission.Aims
Patients and Methods
We present a retrospective review of patients treated with extracorporeally
irradiated allografts for primary and secondary bone tumours with
the mid- and long-term survivorship and the functional and radiographic
outcomes. A total of 113 of 116 (97.4%) patients who were treated with
extracorporeally irradiated allografts between 1996 and 2014 were
followed up. Forms of treatment included reconstructions, prostheses
and composite reconstructions, both with and without vascularised
grafts. Survivorship was determined by the Kaplan-Meier method.
Clinical outcomes were assessed using the Musculoskeletal Tumor
Society (MSTS) scoring system, the Toronto Extremity Salvage Score
(TESS) and Quality of Life-C30 (QLQ-30) measures. Radiographic outcomes
were assessed using the International Society of Limb Salvage (ISOLS)
radiographic scoring system.Aims
Patients and Methods
In 1999, we developed a technique for biological
reconstruction after excision of a bone tumour, which involved using
autografts of the bone containing the tumour treated with liquid
nitrogen. We have previously reported the use of this technique
in 28 patients at a mean follow up of 27 months (10 to 54). In this study, we included 72 patients who underwent reconstruction
using this technique. A total of 33 patients died and three were
lost to follow-up, at a mean of 23 months (2 to 56) post-operatively,
leaving 36 patients available for a assessment at a mean of 101
months 16 to 163) post-operatively. The methods of reconstruction included
an osteo-articular graft in 16, an intercalary in 13 and, a composite
graft with prosthesis in seven. Post-operative function was excellent in 26 patients (72.2%),
good in seven (19.4%), and fair in three (8.3%) according to the
functional evaluation system of Enneking. No recurrent tumour occurred
within the grafts. The autografts survived in 29 patients (80.6%),
and the rates of survival at five and ten years were 86.1% and 80.6
%, respectively. Seven of 16 osteo-articular grafts (44%) failed
because of fracture or infection, but all the composite and intercalary
grafts survived. The long-term outcomes of frozen autografting, particularly using
composite and intercalary grafts, are satisfactory and thus represent
a good method of treatment for patients with a sarcoma of bone or
soft tissue. Cite this article:
The aims of this study were to analyse the long-term outcome
of vascularised fibular graft (VFG) reconstruction after tumour
resection and to evaluate the usefulness of the method. We retrospectively reviewed 49 patients who had undergone resection
of a sarcoma and reconstruction using a VFG between 1988 and 2015.
Their mean follow-up was 98 months (5 to 317). Reconstruction was
with an osteochondral graft (n = 13), intercalary graft (n = 12),
inlay graft (n = 4), or resection arthrodesis (n = 20). We analysed
the oncological and functional outcome, and the rate of bony union
and complications.Aims
Patients and Methods
Resection of malignant bony tumours of the pelvis
creates large bone and soft-tissue defects, and is frequently associated
with complications such as wound dehiscence and deep infection.
We present the results of six patients in whom a rectus abdominis
myocutaneous (RAM) flap was used following resection of a malignant
tumour of the pelvis. Bony reconstruction was performed using a
constrained hip tumour prosthesis in three patients, vascularised
fibular graft in two and frozen autograft in one. At a mean follow-up
of 63 months (16 to 115), no patients had a problem with the wound. Immediate reconstruction using a RAM flap may be used after resection
of a malignant tumour of the pelvis to provide an adequate volume
of tissue to eliminate the dead space, cover the exposed bone or
implants with well-vascularised soft tissue and to reduce the risk
of complications. Cite this article:
We report our early experience with the use of
a new prosthesis, the Modular Hemipelvic Prosthesis II, for reconstruction
of the hemipelvis after resection of a primary malignant peri-acetabular
tumour involving the sacroiliac joint. We retrospectively reviewed the outcome of 17 patients who had
undergone resection of a pelvic tumour and reconstruction with this
prosthesis between July 2002 and July 2010. One patient had a type I+II+III+IV resection (ilium + peri-acetabulum
+ pubis/ischium + sacrum) and 16 had a type I+II+IV resection (ilium
+ acetabulum + sacrum). The outcome was assessed at a mean follow-up
of 33 months (15 to 59). One patient was alive with disease, 11
were alive without disease and five had died of disease. The overall
five-year survival rate was 62.4%. Six patients had a local recurrence.
The mean Musculoskeletal Tumour Society score was 58% (33 to 77).
Deep infection occurred in two patients, problems with wound healing
in five and dislocation in one. For patients with a primary malignant peri-acetabular sarcoma
involving the sacroiliac joint, we believe that this new prosthesis
is a viable option for reconstruction of the bony defect left following
resection of the tumour. It results in a satisfactory functional
outcome with an acceptable rate of complications. Cite this article:
Resection of a primary sarcoma of the diaphysis
of a long bone creates a large defect. The biological options for reconstruction
include the use of a vascularised and non-vascularised fibular autograft. The purpose of the present study was to compare these methods
of reconstruction. Between 1985 and 2007, 53 patients (26 male and 27 female) underwent
biological reconstruction of a diaphyseal defect after resection
of a primary sarcoma. Their mean age was 20.7 years (3.6 to 62.4).
Of these, 26 (49 %) had a vascularised and 27 (51 %) a non-vascularised
fibular autograft. Either method could have been used for any patient in
the study. The mean follow-up was 52 months (12 to 259). Oncological,
surgical and functional outcome were evaluated. Kaplan–Meier analysis
was performed for graft survival with major complication as the
end point. At final follow-up, eight patients had died of disease. Primary
union was achieved in 40 patients (75%); 22 (42%) with a vascularised
fibular autograft and 18 (34%) a non-vascularised (p = 0.167). A
total of 32 patients (60%) required revision surgery. Kaplan–Meier
analysis revealed a mean survival without complication of 36 months
(0.06 to 107.3, Both groups seem to be reliable biological methods of reconstructing
a diaphyseal bone defect. Vascularised autografts require more revisions
mainly due to problems with wound healing in distal sites of tumour,
such as the foot. Cite this article:
We welcome letters to the Editor concerning articles
that have recently been published. Such letters will be subject
to the usual stages of selection and editing; where appropriate the
authors of the original article will be offered the opportunity
to reply.