Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 95 - 98
1 Jan 2004
Riding G Daly K Hutchinson S Rao S Lovell M McCollum C

Fat embolism occurs following fractures of a long bone or arthroplasty. We investigated whether paradoxical embolisation through a venous-to-arterial circulation shunt (v-a) could lead to cerebral embolisation during elective hip or knee arthroplasty. Transcranial Doppler ultrasound (TCD), following the intravenous injection of microbubble contrast, identified the presence of a shunt in 41 patients undergoing hip (n=20) or knee (n=21) arthroplasty. Intra-operative cerebral embolism was detected during continuous TCD monitoring. Of the 41 patients, 34 had a v-a shunt of whom 18 had an embolism and embolism only occurred in patients with a shunt (p = 0.012). Spontaneous and larger shunts were associated with a greater number of emboli (r. s. = 0.67 and r. s. = 0.71 respectively, p < 0.01). Observations in two patients with large spontaneous shunts revealed 368 and 203 emboli and unexplained post-operative confusion and pancreatitis. Paradoxical cerebral embolisation only occurred in patients with a shunt and may explain both postoperative confusion and fat embolism syndrome following surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 90 - 92
1 Jan 2001
Barriga A Nin JRV Delgado C Bilbao JJ

We describe three cases of postoperative haemorrhage, two after total hip and one after total knee replacement, treated by percutaneous embolisation. After diagnostic angiography, this is the preferred method for the treatment of postoperative haemorrhage due to the formation of a false aneurysm, after hip or knee arthroplasty. This procedure, carried out under local anaesthesia, has a low rate of complications and avoids the uncertainty of further surgical exploration


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 379 - 384
1 May 1997
McCaskie AW Barnes MR Lin E Harper WM Gregg PJ

The newer techniques of cementing aim to improve interlock between cement and bone around a femoral stem by combining high pressure and reduced viscosity. This may produce increased embolisation of fat and marrow leading to hypotension, impaired pulmonary gas exchange and death. For this reason the use of high pressures has been questioned. We compared finger-packing with the use of a cement gun by measuring intramedullary pressures during the cementing of 31 total hip replacements and measuring physiological changes in 19 patients. We also measured pressure in more detail in a laboratory model. In the clinical series the higher pressures were produced by using a gun, but this caused less physiological disturbance than finger-packing. The laboratory studies showed more consistent results with the gun technique, but for both methods of cementing the highest pressures were generated during the insertion of the stem of the prosthesis