Fat embolism occurs following fractures of a long bone or arthroplasty. We investigated whether paradoxical
Giant-cell tumours of the sacrum are difficult to treat. Surgery carries a high risk of morbidity, local recurrence and mortality. Radiation is effective in some patients, but has a risk of malignant change. We evaluated the effectiveness of serial arterial
We describe the successful relief of compression of the spinal cord due to a vertebral haemangioma by transcatheter
Arteriovenous fistula formation after a closed
extremity fracture is rare. We present the case of an 11-year-old
boy who developed an arteriovenous fistula between the anterior
tibial artery and popliteal vein after closed fractures of the proximal
tibia and fibula. The fractures were treated by closed reduction
and casting. A fistula was diagnosed 12 weeks after the injury.
It was treated by
We describe three cases of postoperative haemorrhage, two after total hip and one after total knee replacement, treated by percutaneous
Exsanguination is the second most common cause
of death in patients who suffer severe trauma. The management of
haemodynamically unstable high-energy pelvic injuries remains controversial,
as there are no universally accepted guidelines to direct surgeons
on the ideal use of pelvic packing or early angio-embolisation.
Additionally, the optimal resuscitation strategy, which prevents
or halts the progression of the trauma-induced coagulopathy, remains
unknown. Although early and aggressive use of blood products in
these patients appears to improve survival, over-enthusiastic resuscitative
measures may not be the safest strategy. . This paper provides an overview of the classification of pelvic
injuries and the current evidence on best-practice management of
high-energy pelvic fractures, including resuscitation, transfusion
of blood components, monitoring of coagulopathy, and procedural
interventions including pre-peritoneal pelvic packing, external
fixation and angiographic
We performed transoesophageal echocardiography in 111 operations (110 patients) which included medullary reaming for fresh fractures of the femur and tibia, pathological lesions of the femur, and hemiarthroplasty of the hip. Embolic events of varying intensity were seen in 97 procedures and measured pulmonary responses correlated with the severity of embolic phenomena. Twenty-four out of the 25 severe embolic responses occurred while reaming pathological lesions or during cemented hemiarthroplasty of the hip and, overall, pathological lesions produced the most severe responses. Paradoxical
Bleeding is a major complication of revision total hip replacement. We report a case where the inflated balloon of a urinary catheter was used to temporarily control intrapelvic bleeding from the superior gluteal artery, while definitive measures for endovascular
High energy fractures of the pelvis are a challenging problem both in the immediate post-injury phase and later when definitive fixation is undertaken. No single management algorithm can be applied because of associated injuries and the wide variety of trauma systems that have evolved around the world. Initial management is aimed at saving life and this is most likely to be achieved with an approach that seeks to identify and treat life-threatening injuries in order of priority. Early mortality after a pelvic fracture is most commonly due to major haemorrhage or catastrophic brain injury. In this article we review the role of pelvic binders, angiographic
We undertook a prospective, randomised study using a non-invasive transcranial Doppler device to evaluate cranial
In a series of 150 consecutive patients with unstable fractures of the pelvis, angiography was performed in 23 (15%) who had uncontrolled hypotension. There were three anteroposterior compression (APC), eight lateral compression (LC) and 12 vertical shear (VS) injuries. Arterial sources of haemorrhage were identified in 18 (78%) patients and
The results of primary total knee replacement performed on a group of haemophiliac patients in a single institution by the same surgeon using the same surgical technique and prosthesis are reported. A total of 35 primary replacements in 30 patients were carried out between 1996 and 2005 and were reviewed retrospectively. The mean age of the patients was 31 years (24 to 42) and the mean follow-up was for 7.5 years (1 to 10). There were 25 patients with haemophilia A and five with haemophilia B. The HIV status and CD4 count were recorded, and Knee Society scores determined. Two patients had inhibitors to the deficient coagulation factor. There were no early wound infections and only one late deep infection which required a two-stage revision arthroplasty, with a good final result. The incidence of infection in HIV-positive and negative patients was thus similar. One knee in a patient with inhibitor had excessive bleeding due to a pseudoaneurysm which required
We present a patient with an arteriovenous fistula of the peroneal artery acquired after a left dome tibial osteotomy with midshaft fibular osteotomy. He had subsequently had a total knee replacement on that side. The arteriovenous malformation was only diagnosed when he represented with symptoms and signs of venous hypertension with sterile recurrent haemarthroses in the left knee. Percutaneous obliteration of the fistula, by a combination of coil
Osteotomies are commonly carried out in orthopaedic surgery, particularly in limb reconstruction. Complications are uncommon provided that sufficient care is taken and a sound technique used. We describe three cases of formation of false aneurysm after osteotomy, with acute, delayed and asymptomatic onset. The diagnosis was supported by ultrasound investigation, and confirmed by angiography.
A prospective study on 227 patients undergoing arthroplasty of the hip was carried out with reference to the effects on the cardiovascular and respiratory systems. Investigations revealed that the placing of acrylic bone cement and the prosthesis in the femoral shaft produced clinical and biochemical disturbances which were consistent with pulmonary microembolism. A fall in arterial oxygen tension during the procedure and hypoxaemia extending into the postoperative period with elevation of serum lipase and a fall in triglycerides supported the idea that
The newer techniques of cementing aim to improve interlock between cement and bone around a femoral stem by combining high pressure and reduced viscosity. This may produce increased