We assessed
Loss of
We assessed
Aims. The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) at one year post-surgery. Methods. A total of 76 patients (34 bi-UKA and 42 TKA patients) were analyzed in a prospective, single-centre, randomized controlled trial. Flat ground shod gait analysis was performed preoperatively and one year postoperatively. Knee flexion moment was calculated from motion capture markers and force plates. The same setup determined
A total of 108 patients with unilateral instability of the knee, associated with rupture of the anterior cruciate ligament, was prospectively randomised for arthroscopic single- or double-bundle reconstruction of the ligament using hamstring tendons. The same postoperative rehabilitation protocol was used for all. The patients were followed up for a mean of 32 months (24 to 36). We measured the anterior laxity and joint position sense at different angles of flexion of the knee to determine whether both bundles in the double-bundle reconstruction contributed to the stability of the joint and
This study compared patient-reported outcomes of three total knee arthroplasty (TKA) designs from one manufacturer: one cruciate-retaining (CR) design, and two cruciate-sacrificing designs, anterior-stabilized (AS) and posterior-stabilized (PS). Patients scheduled for primary TKA were included in a single-centre, prospective, three-armed, blinded randomized trial (n = 216; 72 per group). After intraoperative confirmation of posterior cruciate ligament (PCL) integrity, patients were randomly allocated to receive a CR, AS, or PS design from the same TKA system. Insertion of an AS or PS design required PCL resection. The primary outcome was the mean score of all five subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS) at two-year follow-up. Secondary outcomes included all KOOS subscales, Oxford Knee Score, EuroQol five-dimension health questionnaire, EuroQol visual analogue scale, range of motion (ROM), and willingness to undergo the operation again. Patient satisfaction was also assessed.Aims
Methods
This systematic review and meta-analysis aimed to compare the influence of patellar resurfacing following cruciate-retaining (CR) and posterior-stabilized (PS) total knee arthroplasty (TKA) on the incidence of anterior knee pain, knee-specific patient-reported outcome measures, complication rates, and reoperation rates. A systematic review of MEDLINE, PubMed, and Google Scholar was performed to identify randomized controlled trials (RCTs) according to search criteria. Search terms used included: arthroplasty, replacement, knee (Mesh), TKA, prosthesis, patella, patellar resurfacing, and patellar retaining. RCTs that compared patellar resurfacing versus unresurfaced in primary TKA were included for further analysis. Studies were evaluated using the Scottish Intercollegiate Guidelines Network assessment tool for quality and minimization of bias. Data were synthesized and meta-analysis performed.Aims
Methods
The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA). A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively. Femorotibial contact point (CP) locations were determined at every flexion angle and compared between the groups. RSA images were taken at baseline, six weeks, three, six, 12, and 24 months postoperatively. Clinical and functional outcomes were compared postoperatively for two years.Aims
Methods
The removal of the cruciate ligaments in total knee arthroplasty (TKA) has been suggested as a potential contributing factor to patient dissatisfaction, due to alteration of the in vivo biomechanics of the knee. Bicruciate retaining (BCR) TKA allows the preservation of the cruciate ligaments, thus offering the potential to reproduce healthy kinematics. The aim of this study was to compare in vivo kinematics between the operated and contralateral knee in patients who have undergone TKA with a contemporary BCR design. A total of 29 patients who underwent unilateral BCR TKA were evaluated during single-leg deep lunges and sit-to-stand tests using a validated computer tomography and fluoroscopic imaging system. In vivo six-degrees of freedom (6DOF) kinematics were compared between the BCR TKA and the contralateral knee.Aims
Methods
The purpose of this study was to report the experience of dynamic
intraligamentary stabilisation (DIS) using the Ligamys device for
the treatment of acute ruptures of the anterior cruciate ligament
(ACL). Between March 2011 and April 2012, 50 patients (34 men and 16
women) with an acute rupture of the ACL underwent primary repair
using this device. The mean age of the patients was 30 years (18
to 50). Patients were evaluated for laxity, stability, range of
movement (ROM), Tegner, Lysholm, International Knee Documentation Committee
(IKDC) and visual analogue scale (VAS) scores over a follow-up period
of two years.Aims
Patients and Methods
We have investigated the changes in anterior laxity of the knee in response to direct electrical stimulation of eight normal and 45 reconstructed anterior cruciate ligaments (ACLs). In the latter, the mean time from reconstruction was 26.7 months (24 to 32). The ACL was stimulated electrically using a bipolar electrode probe during arthroscopy. Anterior laxity was examined with the knee flexed at 20° under a force of 134 N applied anteriorly to the tibia using the KT-2000 knee arthrometer before, during and after electrical stimulation. Anterior tibial translation in eight normal and 17 ACL-reconstructed knees was significantly decreased during stimulation, compared with that before stimulation. In 28 knees with reconstruction of the ACL, in 22 of which the grafts were found to have detectable somatosensory evoked potentials during stimulation, anterior tibial translation was not decreased. These findings suggest that the ACL-hamstring reflex arc in normal knees may contribute to the functional stability and that this may not be fully restored after some reconstructions of the ACL.
The anatomy and microstructure of the menisci
allow the effective distribution of load across the knee. Meniscectomy
alters the biomechanical environment and is a potent risk factor
for osteoarthritis. Despite a trend towards meniscus-preserving
surgery, many tears are irreparable, and many repairs fail. Meniscal allograft transplantation has principally been carried
out for pain in patients who have had a meniscectomy. Numerous case
series have reported a significant improvement in patient-reported
outcomes after surgery, but randomised controlled trials have not
been undertaken. It is scientifically plausible that meniscal allograft transplantation
is protective of cartilage, but this has not been established clinically
to date. Cite this article:
We assessed hyperextension of the knee and joint laxity in 169 consecutive patients who underwent an anterior cruciate ligament reconstruction between 2000 and 2002 and correlated this with a selected number of age- and gender-matched controls. In addition, the mechanism of injury in the majority of patients was documented. Joint laxity was present in 42.6% (72 of 169) of the patients and hyperextension of the knee in 78.7% (133 of 169). All patients with joint laxity had hyperextension of their knee. In the control group only 21.5% (14 of 65) had joint laxity and 37% (24 of 65) had hyperextension of the knee. Statistical analysis showed a significant correlation for these associations. We conclude that anterior cruciate ligament injury is more common in those with joint laxity and particularly so for those with hyperextension of the knee.
The aim of this study was to analyse the gait
pattern, muscle force and functional outcome of patients who had undergone
replacement of the proximal tibia for tumour and alloplastic reconstruction
of the extensor mechanism using the patellar-loop technique. Between February 1998 and December 2009, we carried out wide
local excision of a primary sarcoma of the proximal tibia, proximal
tibial replacement and reconstruction of the extensor mechanism
using the patellar-loop technique in 18 patients. Of these, nine
were available for evaluation after a mean of 11.6 years (0.5 to
21.6). The strength of the knee extensors was measured using an
Isobex machine and gait analysis was undertaken in our gait assessment
laboratory. Functional outcome was assessed using the American Knee
Society (AKS) and Musculoskeletal Tumor Society (MSTS) scores. The gait pattern of the patients differed in ground contact time,
flexion heel strike, maximal flexion loading response and total
sagittal plane excursion. The mean maximum active flexion was 91°
(30° to 110°). The overall mean extensor lag was 1° (0° to 5°).
The mean extensor muscle strength was 25.8% (8.3% to 90.3%) of that
in the non-operated leg (p <
0.001). The mean functional scores
were 68.7% (43.4% to 83.3%) (MSTS) and 71.1 (30 to 90) (AKS functional
score). In summary, the results show that reconstruction of the extensor
mechanism using this technique gives good biomechanical and functional
results. The patients’ gait pattern is close to normal, except for
a somewhat stiff knee gait pattern. The strength of the extensor
mechanism is reduced, but sufficient for walking. Cite this article:
The aim of this study was to compare the maximum
laxity conferred by the cruciate-retaining (CR) and posterior-stabilised
(PS) Triathlon single-radius total knee arthroplasty (TKA) for anterior
drawer, varus–valgus opening and rotation in eight cadaver knees
through a defined arc of flexion (0º to 110º). The null hypothesis
was that the limits of laxity of CR- and PS-TKAs are not significantly
different. The investigation was undertaken in eight loaded cadaver knees
undergoing subjective stress testing using a measurement rig. Firstly
the native knee was tested prior to preparation for CR-TKA and subsequently
for PS-TKA implantation. Surgical navigation was used to track maximal
displacements/rotations at 0º, 30º, 60º, 90º and 110° of flexion.
Mixed-effects modelling was used to define the behaviour of the
TKAs. The laxity measured for the CR- and PS-TKAs revealed no statistically
significant differences over the studied flexion arc for the two
versions of TKA. Compared with the native knee both TKAs exhibited
slightly increased anterior drawer and decreased varus-valgus and
internal-external roational laxities. We believe further study is required
to define the clinical states for which the additional constraint
offered by a PS-TKA implant may be beneficial. Cite this article:
The routine use of patient reported outcome measures
(PROMs) in evaluating the outcome after arthroplasty by healthcare
organisations reflects a growing recognition of the importance of
patients’ perspectives in improving treatment. Although widely embraced
in the NHS, there are concerns that PROMs are being used beyond
their means due to a poor understanding of their limitations. This paper reviews some of the current challenges in using PROMs
to evaluate total knee arthroplasty. It highlights alternative methods
that have been used to improve the assessment of outcome. Cite this article:
Our aims were to map the tibial footprint of the posterior cruciate ligament (PCL) using MRI in patients undergoing PCL-preserving total knee replacement, and to document the disruption of this footprint as a result of the tibial cut. In 26 consecutive patients plain radiography and MRI of the knee were performed pre-operatively, and plain radiography post-operatively. The lower margin of the PCL footprint was located a mean of 1 mm (−10 to 8) above the upper aspect of the fibular head. The mean surface area was 83 mm2 (49 to 142). One-third of patients (8 of 22) had tibial cuts made below the lowest aspect of the PCL footprint (complete removal) and one-third (9 of 22) had cuts extending into the footprint (partial removal). The remaining patients (5 of 22) had footprints unaffected by the cuts, keeping them intact. Our study highlights the wide variation in the location of the tibial PCL footprint when referenced against the fibula. Proximal tibial cuts using conventional jigs resulted in the removal of a significant portion, if not all of the PCL footprint in most of the patients in our study. Our findings suggest that when performing PCL-retaining total knee replacement the tibial attachment of the PCL is often removed.
We report the clinical outcome and findings at
second-look arthroscopy of 216 patients (mean age 25 years (11 to 58))
who underwent anterior cruciate ligament (ACL) reconstruction or
augmentation. There were 73 single-bundle ACL augmentations (44
female, 29 male), 82 double-bundle ACL reconstructions (35 female,
47 male), and 61 single-bundle ACL reconstructions (34 female, 27
male). In 94 of the 216 patients, proprioceptive function of the knee
was evaluated before and 12 months after surgery using the threshold
to detect passive motion test. Second-look arthroscopy showed significantly better synovial
coverage of the graft in the augmentation group (good: 60 (82%),
fair: 10 (14%), poor: 3 (4%)) than in the other groups (p = 0.039).
The mean side-to-side difference measured with a KT-2000 arthrometer
was 0.4 mm (-3.3 to 2.9) in the augmentation group, 0.9 mm (-3.2
to 3.5) in the double-bundle group, and 1.3 mm (-2.7 to 3.9) in
the single-bundle group: the result differed significantly between
the augmentation and single-bundle groups (p = 0 .013). No significant
difference in the Lysholm score or pivot-shift test was seen between
the three groups (p = 0.09 and 0.65, respectively). In patients
with good synovial coverage, three of the four measurements used
revealed significant improvement in proprioceptive function (p = 0.177,
0.020, 0.034, and 0.026). We conclude that ACL augmentation is a reasonable treatment option
for patients with favourable ACL remnants. Cite this article:
Hypermobility is an acknowledged risk factor
for patellar instability. In this case control study the influence
of hypermobility on clinical outcome following medial patellofemoral
ligament (MPFL) reconstruction for patellar instability was studied. A total of 25 patients with hypermobility as determined by the
Beighton criteria were assessed and compared with a control group
of 50 patients who were matched for age, gender, indication for
surgery and degree of trochlear dysplasia. The patients with hypermobility
had a Beighton Score of ≥ 6; the control patients had a score of <
4. All patients underwent MPFL reconstruction performed using semitendinosus
autograft and a standardised arthroscopically controlled technique.
The mean age of the patients was 25 years (17 to 49) and the mean
follow-up was 15 months (6 to 30). Patients with hypermobility had a significant improvement in
function following surgery, with reasonable rates of satisfaction,
perceived improvement, willingness to repeat and likelihood of recommendation.
Functional improvements were significantly less than in control
patients (p <
0.01). Joint hypermobility is not a contraindication to MPFL reconstruction
although caution is recommended in managing the expectations of
patients with hypermobility before consideration of surgery.
We continued a prospective longitudinal follow-up
study of 53 remaining patients who underwent open total meniscectomy
as adolescents and who at that time had no other intra-articular
pathology of the knee. Their clinical, radiological and patient-reported
outcomes are described at a mean follow-up of 40 years (33 to 50).
The cohort of patients who had undergone radiological evaluation
previously after 30 years were invited for clinical examination,
radiological evaluation and review using two patient-reported outcome
measures. A total of seven patients (13.2%) had already undergone total
knee replacement at the time of follow-up. A significant difference
was observed between the operated and non-operated knee in terms
of range of movement and osteoarthritis of the tibiofemoral joint,
indicating a greater than fourfold relative risk of osteoarthritis
at 40 years post-operatively. All patients were symptomatic as defined
by the Knee Injury and Osteoarthritis Outcome Score. This study represents the longest follow-up to date and it can
be concluded that meniscectomy leads to symptomatic osteoarthritis
of the knee later in life, with a resultant 132-fold increase in
the rate of total knee replacement in comparison to their geographical
and age-matched peers.