Aims. The purpose of the present study was to evaluate the impact of
intravenous tranexamic acid on the reduction of blood loss, transfusion
rate, and early
Aims. To determine the incidence and timing of
To prevent insufficiency of the triceps after
total elbow arthroplasty, we have, since 2008, used a triceps-sparing ulnar
approach. This study evaluates the clinical results and post-operative
alignment of the prosthesis using this approach. We reviewed 25 elbows in 23 patients. There were five men and
18 women with a mean age of 69 years (54 to 83). There were 18 elbows
with rheumatoid arthritis, six with a fracture or pseudoarthrosis
and one elbow with osteoarthritis.
Aims. In the initial development of total shoulder arthroplasty (TSA),
the humeral component was usually fixed with cement. Cementless
components were subsequently introduced. The aim of this study was
to compare the long-term outcome of cemented and cementless humeral
components in arthroplasty of the shoulder. Patients and Methods. All patients who underwent primary arthroplasty of the shoulder
at our institution between 1970 and 2012 were included in the study.
There were 4636 patients with 1167 cemented humeral components and
3469 cementless components. Patients with the two types of fixation
were matched for nine different covariates using a propensity score
analysis. A total of 551 well-balanced pairs of patients with cemented
and cementless components were available after matching for comparison
of the outcomes. The clinical outcomes which were analysed included loosening
of the humeral component determined at revision surgery, periprosthetic
fractures,
Aims. To compare radiographic failure and re-operation rates of anatomical
coracoclavicular (CC) ligament reconstructional techniques with
non-anatomical techniques after chronic high grade acromioclavicular
(AC) joint injuries. . Patients and Methods. We reviewed chronic AC joint reconstructions within a region-wide
healthcare system to identify surgical technique, complications,
radiographic failure and re-operations. Procedures fell into four
categories: (1) modified Weaver-Dunn, (2) allograft
fixed through coracoid and clavicular tunnels, (3) allograft loop
coracoclavicular fixation, and (4) combined allograft loop and synthetic
cortical button fixation. Among 167 patients (mean age 38.1 years,
(standard deviation (. sd. ) 14.7) treated at least a four
week interval after injury, 154 had
Aims. The aim of the present study was to compare the 30- and 90-day
re-admission rates and complication rates of outpatient and inpatient
total shoulder arthroplasty (TSA). Patients and Methods. The United States Medicare Standard Analytical Files database
was questioned to identify patients who had undergone outpatient
or inpatient TSA between 2005 and 2012. Patient characteristics
were compared between the two groups using chi-squared analysis. Multivariate
logistic regression analysis was used to control for differences
in baseline patient characteristics and to compare the two groups
in terms of
The indications for reverse shoulder arthroplasty
(RSA) continue to be expanded. Associated impairment of the deltoid
muscle has been considered a contraindication to its use, as function
of the RSA depends on the deltoid and impairment of the deltoid
may increase the risk of dislocation. The aim of this retrospective
study was to determine the functional outcome and risk of dislocation
following the use of an RSA in patients with impaired deltoid function.
Between 1999 and 2010, 49 patients (49 shoulders) with impairment
of the deltoid underwent RSA and were reviewed at a mean of 38 months
(12 to 142) post-operatively. There were nine
Aims. Radial head arthroplasty (RHA) may be used in the treatment of
non-reconstructable radial head fractures. The aim of this study
was to evaluate the mid-term clinical and radiographic results of
RHA. Patients and Methods. Between 2002 and 2014, 77 RHAs were implanted in 54 men and 23
women with either acute injuries (54) or with traumatic sequelae
(23) of a fracture of the radial head. Four designs of RHA were
used, including the Guepar (Small Bone Innovations (SBi)/Stryker;
36), Evolutive (Aston Medical; 24), rHead RECON (SBi/Stryker; ten)
or rHead STANDARD (SBi/Stryker; 7) prostheses. The mean follow-up
was 74.0 months (standard deviation (. sd. ) 38.6; 24 to 141).
The indication for further surgery, range of movement, mean Mayo
Elbow Performance (MEP) score, quick Disabilities of the Arm, Shoulder
and Hand (quickDASH) score, osteolysis and positioning of the implant
were also assessed according to the design, and acute or delayed
use. Results. The mean MEP and quickDASH scores were 90.2 (. sd. 14;
45 to 100), and 14.0 points (. sd. 12; 1.2 to 52.5), respectively. There
were no significant differences between RHA performed in acute or
delayed fashion. There were 30 re-operations (19 with, and 11 without
removal of the implant) during the first three
Aims. Manipulation under anaesthetic (MUA) is a recognised form of
treatment for patients with a frozen shoulder. However, not all
patients benefit. Some have persistent or recurrent symptoms. There
are no clear recommendations in the literature on the optimal management
of recurrent frozen shoulder after a MUA. We aimed to address this
issue in this study. Patients and Methods. We analysed a prospectively collected, single-surgeon, consecutive
series of patients who underwent MUA for frozen shoulder between
January 1999 and December 2015. The Oxford Shoulder Scores (OSS)
and range of movement were the outcome measures. . Results. A total of 730 patients (792 shoulders) underwent MUA during
the study period. A further MUA was undertaken in 141 shoulders
(17.8%), for which we had complete data for 126. The mean improvement
in OSS for all patients undergoing MUA was 16 (26 to 42), and the
mean
Aims. Depression can significantly affect quality of life and is associated
with higher rates of medical comorbidities and increased mortality
following surgery. Although depression has been linked to poorer
outcomes following orthopaedic trauma, total joint arthroplasty
and spinal surgery, we wished to examine the impact of depression
in elective total shoulder arthroplasty (TSA) as this has not been
previously explored. . Patients and Methods. The United States Nationwide Inpatient Sample (NIS) was used
to identify patients undergoing elective TSA over a ten-year period.
Between 2002 and 2012, 224 060 patients underwent elective TSA. Results. Among the identified patients who had undergone TSA, 12.4% had
a diagnosis of a history of depression. A diagnosis of depression
was twice as common in women compared with men (16.0% vs 8.0%,
p <
0.001), and more frequent in those with low income and Medicaid
insurance (p <
0.001). A diagnosis of depression was an independent
risk factor for
Aims. Revision total elbow arthroplasty (TEA) is often challenging.
The aim of this study was to report on the clinical and radiological
results of revision arthroplasty of the elbow with the Latitude
TEA. Patients and Methods. Between 2006 and 2010 we used the Latitude TEA for revision in
18 consecutive elbows (17 patients); mean age 53 years (28 to 80);
14 women. A Kudo TEA was revised in 15 elbows and a Souter-Strathclyde
TEA in three. Stability, range of movement (ROM), visual analogue score (VAS)
for pain and functional scores, Elbow Functional Assessment Scale
(EFAS), the Functional Rating Index of Broberg and Morrey (FRIBM)
and the Modified Andrews’ Elbow Scoring System (MAESS) were assessed
pre-operatively and at each
Aims. Patient-specific glenoid guides (PSGs) claim an improvement in
accuracy and reproducibility of the positioning of components in
total shoulder arthroplasty (TSA). The results have not yet been
confirmed in a prospective clinical trial. Our aim was to assess
whether the use of PSGs in patients with osteoarthritis of the shoulder
would allow accurate and reliable implantation of the glenoid component. Patients and Methods. A total of 17 patients (three men and 14 women) with a mean age
of 71 years (53 to 81) awaiting TSA were enrolled in the study.
Pre- and
Aims. To date, there is insufficient evidence available to compare
the outcome of cemented and uncemented fixation of the humeral stem
in reverse shoulder arthroplasty (RSA). . Methods. A systemic review comprising 41 clinical studies was performed
to compare the functional outcome and rate of complications of cemented
and uncemented stems in RSA. These included 1455 cemented and 329
uncemented shoulders. The clinical characteristics of the two groups
were similar. Variables were compared using pooled frequency-weighted means
and relative risk ratios (RR). Results. Uncemented stems had a significantly higher incidence of early
humeral stem migration (p <
0.001, RR 18.1, 95% confidence interval
(CI) 5.0 to 65.2) and non-progressive radiolucent lines (p <
0.001, RR 2.4, 95% CI 1.7 to 3.4), but a significantly lower incidence
of
If a modular convertible total shoulder system
is used as a primary implant for an anatomical total shoulder arthroplasty,
failure of the prosthesis or the rotator cuff can be addressed by
converting it to a reverse shoulder arthroplasty (RSA), with retention
of the humeral stem and glenoid baseplate. This has the potential
to reduce morbidity and improve the results. . In a retrospective study of 14 patients (15 shoulders) with a
mean age of 70 years (47 to 83) we reviewed the clinical and radiological
outcome of converting an anatomical shoulder arthroplasty (ASA)
to a RSA using a convertible prosthetic system (SMR system, Lima,
San Daniele, Italy). . The mean operating time was 64 minutes (45 to 75). All humeral
stems and glenoid baseplates were found to be well-fixed and could
be retained. There were no intra-operative or early post-operative
complications and no
We retrospectively assessed the value of identifying
impinging osteophytes using dynamic computer simulation of CT scans
of the elbow in assisting their arthroscopic removal in patients
with osteoarthritis of the elbow. A total of 20 patients were treated
(19 men and one woman, mean age 38 years (19 to 55)) and followed
for a mean of 25 months (24 to 29). We located the impinging osteophytes
dynamically using computerised three-dimensional models of the elbow
based on CT data in three positions of flexion of the elbow. These
were then removed arthroscopically and a capsular release was performed. The mean loss of extension improved from 23° (10° to 45°) pre-operatively
to 9° (0° to 25°) post-operatively, and the mean flexion improved
from 121° (80° to 140°) pre-operatively to 130° (110° to 145°) post-operatively.
The mean Mayo Elbow Performance Score improved from 62 (30 to 85)
to 95 (70 to 100) post-operatively. All patients had pain in the
elbow pre-operatively which disappeared or decreased post-operatively.
According to their Mayo scores, 14 patients had an excellent clinical
outcome and six a good outcome; 15 were very satisfied and five
were satisfied with their
Few studies have evaluated the relationship between patients’
pre-operative expectations and the outcome of orthopaedic procedures.
Our aim was to determine the effect of expectations on the outcome
after primary anatomical total shoulder arthroplasty (TSA). We hypothesised
that patients with greater expectations would have better outcomes. Patients undergoing primary anatomical TSA completed the Hospital
for Special Surgery’s Shoulder Expectations Survey pre-operatively.
The American Shoulder and Elbow Surgeons (ASES), Shoulder Activity
Scale (SAS), Short-Form-36 (SF-36), and visual analogue scale (VAS)
for pain, fatigue, and general health scores were also collected
pre-operatively and two years post-operatively. Pearson correlations
were used to assess the relationship between the number of expectations
and the outcomes. Differences in outcomes between those with higher
and lower levels of expectations for each expectation were assessed
by independent samples Aims
Patients and Methods
We assessed the long-term (more than ten-year) outcomes of the
Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis
(RA). We reviewed 41 elbows (Larsen Grade IV, n = 21; Grade V, n =
20) in 31 patients with RA who had undergone a Kudo type-5 total
elbow arthroplasty (TEA) between 1994 and 2003, and had been followed
up for more than ten years. The humeral component was cementless
and the all-polyethylene ulnar component cemented in every patient. Clinical
outcome was assessed using the Mayo elbow performance score. We
calculated the revision rate and evaluated potential risk factors
for revision. The duration of follow-up was a mean 141 months (120
to 203).Aims
Materials and Methods
The aim of this study was to report the long-term outcome and
implant survival of the lateral resurfacing elbow (LRE) arthroplasty
in the treatment of elbow arthritis. We reviewed a consecutive series of 27 patients (30 elbows) who
underwent LRE arthroplasty between December 2005 and January 2008.
There were 15 women and 12 men, with a mean age of 61 years (25
to 82). The diagnosis was primary hypotrophic osteoarthritis (OA)
in 12 patients (14 elbows), post-traumatic osteoarthritis (PTOA)
in five (five elbows) and rheumatoid arthritis (RA) in ten patients
(11 elbows). The mean clinical outcome scores including the Mayo
Elbow Performance Score (MEPS), the American Shoulder and Elbow
Surgeons elbow score (ASES-e), the mean range of movement and the
radiological outcome were recorded at three, six and 12 months and
at a mean final follow-up of 8.3 years (7.3 to 9.4). A one sample Aim
Patients and Methods
Radiostereometric analysis (RSA) allows an extremely accurate
measurement of early micromotion of components following arthroplasty. In this study, RSA was used to measure the migration of 11 partially
cemented fluted pegged glenoid components in patients with osteoarthritis
who underwent total shoulder arthroplasty using an improved surgical
technique (seven men, four women, mean age 68). Patients were evaluated
clinically using the American Shoulder and Elbow Surgeons (ASES)
and Constant-Murley scores and by CT scans two years post-operatively. Aims
Patients and Methods
Advances in arthroscopic techniques for rotator cuff repair have
made the mini-open approach less popular. However, the mini-open
approach remains an important technique for repair for many surgeons.
The aims of this study were to compare the integrity of the repair,
the function of the shoulder and satisfaction post-operatively using
these two techniques in patients aged >
50 years. We identified 22 patients treated with mini-open and 128 patients
treated with arthroscopic rotator cuff repair of July 2007 and June
2011. The mean follow-up was two years (1 to 5). Outcome was assessed
using the American Shoulder and Elbow Surgeons (ASES) and Simple
Shoulder Test (SST) scores, and satisfaction. The integrity of the repair
was assessed using ultrasonography. A power analysis ensured sufficient
enrolment.Aims
Patients and Methods