Advertisement for orthosearch.org.uk
Results 1 - 20 of 45
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 675 - 680
1 May 2015
Domeij-Arverud E Labruto F Latifi A Nilsson G Edman G Ackermann PW

Deep vein thrombosis is a common complication of immobilising the lower limb after surgery. We hypothesised that intermittent pneumatic compression (IPC) therapy in outpatients who had undergone surgical repair of acute ruptures of the Achilles tendon could reduce the incidence of this problem. A total of 150 patients who had undergone surgical repair of the Achilles tendon were randomised to either treatment with IPC for six hours per day (n = 74) under an orthosis or treatment as usual (n = 74) in a plaster cast without IPC. At two weeks post-operatively, the incidence of deep vein thrombosis was assessed using blinded, double-reported compression duplex ultrasound. At this point, IPC was discontinued and all patients were immobilised in an orthosis for a further four weeks. At six weeks post-operatively, a second compression duplex ultrasound scan was performed. At two weeks, the incidence of deep vein thrombosis was 21% in the treated group and 37% in the control group (p = 0.042). Age over 39 years was found to be a strong risk factor for deep vein thrombosis (odds ratio (OR) = 4.84, 95% confidence interval (CI) 2.14 to 10.96). Treatment with IPC, corrected for age differences between groups, reduced the risk of deep vein thrombosis at the two-week point (OR = 2.60; 95% CI 1.15 to 5.91; p =0.022). At six weeks, the incidence of deep vein thrombosis was 52% in the treated group and 48% in the control group (OR 0.94, 95% CI 0.49 to 1.83). IPC appears to be an effective method of reducing the risk of deep vein thrombosis in the early stages of post-operative immobilisation of outpatients. Further research is necessary to elucidate whether it can confer similar benefits over longer periods of immobilisation and in a more heterogeneous group of patients. Cite this article: Bone Joint J 2015;97-B:675–80


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 411 - 415
1 Mar 2006
Challis MJ Gaston P Wilson K Jull GA Crawford R

The aim of this randomised, controlled in vivo study in an ovine model was to investigate the effect of cylic pneumatic pressure on fracture healing. We performed a transverse osteotomy of the right radius in 37 sheep. They were randomised to a control group or a treatment group where they received cyclic loading of the osteotomy by the application of a pressure cuff around the muscles of the proximal forelimb. Sheep from both groups were killed at four or six weeks. Radiography, ultrasonography, biomechanical testing and histomorphometry were used to assess the differences between the groups. The area of periosteal callus, peak torsional strength, fracture stiffness, energy absorbed over the first 10° of torsion and histomorphometric analysis all showed that the osteotomies treated with the cyclic pneumatic pressure at four weeks were not significantly different from the control osteotomies at six weeks.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 729 - 734
1 Jun 2012
Kakkos SK Warwick D Nicolaides AN Stansby GP Tsolakis IA

We performed a systematic review and meta-analysis to compare the efficacy of intermittent mechanical compression combined with pharmacological thromboprophylaxis, against either mechanical compression or pharmacological prophylaxis in preventing deep-vein thrombosis (DVT) and pulmonary embolism in patients undergoing hip or knee replacement. A total of six randomised controlled trials, evaluating a total of 1399 patients, were identified. In knee arthroplasty, the rate of DVT was reduced from 18.7% with anticoagulation alone to 3.7% with combined modalities (risk ratio (RR) 0.27, p = 0.03; number needed to treat: seven). There was moderate, albeit non-significant, heterogeneity (I2 = 42%). In hip replacement, there was a non-significant reduction in DVT from 8.7% with mechanical compression alone to 7.2% with additional pharmacological prophylaxis (RR 0.84) and a significant reduction in DVT from 9.7% with anticoagulation alone to 0.9% with additional mechanical compression (RR 0.17, p < 0.001; number needed to treat: 12), with no heterogeneity (I2 = 0%). The included studies had insufficient power to demonstrate an effect on pulmonary embolism.

We conclude that the addition of intermittent mechanical leg compression augments the efficacy of anticoagulation in preventing DVT in patients undergoing both knee and hip replacement. Further research on the role of combined modalities in thromboprophylaxis in joint replacement and in other high-risk situations, such as fracture of the hip, is warranted.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 795 - 800
1 Aug 2000
Westrich GH Haas SB Mosca P Peterson M

We performed a meta-analysis of the English literature to assess the efficacy of four common regimes for thromboembolic prophylaxis after total knee arthroplasty: aspirin, warfarin, low-molecular-weight heparin (LMWH) and pneumatic compression. We reviewed 136 articles and abstracts published between January 1980 and December 1997. Papers not using routine venography and a lung scan or angiography to detect deep-venous thrombosis (DVT) and pulmonary emboli (PE) respectively, were excluded. Of the 136 studies, 23 with 6001 patients were selected. The incidence of DVT was 53% (1701/3214) in the aspirin group, 45% (541/1203) in the warfarin group, 29% (311/1075) in the LMWH group, and 17% (86/509) in the pneumatic compression device group. Intermittent pneumatic compression devices and LMWH were significantly better than warfarin (p < 0.0001) or aspirin (p < 0.0001) in preventing DVT. The incidence of asymptomatic PE was 11.7% in the aspirin group (222/1901), 8.2% (101/1229) in the warfarin group and 6.3% (24/378) in the pneumatic compression group. No studies with LMWH used routine lung scans. Warfarin and pneumatic compression were significantly better than aspirin in preventing asymptomatic PE (p < 0.05). The incidence of symptomatic PE was 1.3% (23/1800) in the aspirin group, 0.4% (2/559) in the warfarin group, 0.5% (2/416) in the LMWH group and 0% (0/177) in the pneumatic compression group. No statistically significant difference was noted between the above prophylatic regimes due to the very small incidence of symptomatic PE. Prophylaxis for thromboembolic disease in TKA may have to include a combination of some of the above regimes to incorporate their advantages


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 809 - 812
1 Aug 2004
Silbersack Y Taute B Hein W Podhaisky H

After total hip (THR) or knee replacement (TKR), there is still an appreciable risk of developing deep-vein thrombosis despite prophylaxis with low-molecular-weight heparin (LMWH). In a prospective, randomised study we examined the efficacy of LMWH in combination with intermittent pneumatic compression in patients undergoing primary unilateral THR or TKR. We administered 40 mg of enoxaparin daily to 131 patients combined with either the use of intermittent pneumatic compression or the wearing of graduated compression stockings. Compression ultrasonography showed no evidence of thrombosis after LMWH and intermittent pneumatic compression. In the group with LMWH and compression stockings the prevalence of thrombosis was 28.6% (40% after TKR, 14% after THR). This difference was significant (p < 0.0001). In the early post-operative phase after THR and TKR, combined prophylaxis with LMWH and intermittent pneumatic compression is more effective than LMWH used with graduated compression stockings


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 654 - 659
1 Jul 1999
Blanchard J Meuwly J Leyvraz P Miron M Bounameaux H Hoffmeyer P Didier D Schneider P

The optimal regime of antithrombotic prophylaxis for patients undergoing total knee arthroplasty (TKA) has not been established. Many surgeons employ intermittent pneumatic compression while others use low-molecular-weight heparins (LMWH) which were primarily developed for total hip arthroplasty. We compared the efficacy and safety of these two techniques in a randomised study with blinded assessment of the endpoint by phlebography. We randomised 130 patients, scheduled for elective TKA, to receive one daily subcutaneous injection of nadroparin calcium (dosage adapted to body-weight) or continuous intermittent pneumatic compression of the foot by means of the arteriovenous impulse system. A total of 108 patients (60 in the LMWH group and 48 in the mechanical prophylaxis group) had phlebography eight to 12 days after surgery. Of the 47 with deep-vein thrombosis, 16 had received LMWH (26.7%, 95% CI 16.1 to 39.7) and 31, mechanical prophylaxis (64.6%, 95% CI 49.5 to 77.8). The difference between the two groups was highly significant (p < 0.001). Only one patient in the LMWH group had severe bleeding. We conclude that one daily subcutaneous injection of calcium nadroparin in a fixed, weight-adjusted dosage scheme is superior to intermittent pneumatic compression of the foot for thromboprophylaxis after TKA. The LMWH scheme was also safe


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 71 - 77
1 Jul 2020
Gonzalez Della Valle A Shanaghan KA Nguyen J Liu J Memtsoudis S Sharrock NE Salvati EA

Aims. We studied the safety and efficacy of multimodal thromboprophylaxis in patients with a history of venous thromboembolism (VTE) who undergo total hip arthroplasty (THA) within the first 120 postoperative days, and the mortality during the first year. Multimodal prophylaxis includes discontinuation of procoagulant medications, VTE risk stratification, regional anaesthesia, an intravenous bolus of unfractionated heparin prior to femoral preparation, rapid mobilization, the use of pneumatic compression devices, and chemoprophylaxis tailored to the patient’s risk of VTE. Methods. Between 2004 to 2018, 257 patients with a proven history of VTE underwent 277 primary elective THA procedures by two surgeons at a single institution. The patients had a history of deep vein thrombosis (DVT) (186, 67%), pulmonary embolism (PE) (43, 15.5%), or both (48, 17.5%). Chemoprophylaxis included aspirin (38 patients), anticoagulation (215 patients), or a combination of aspirin and anticoagulation (24 patients). A total of 50 patients (18%) had a vena cava filter in situ at the time of surgery. Patients were followed for 120 days to record complications, and for one year to record mortality. Results. Postoperative VTE was diagnosed in seven patients (2.5%): DVT in five, and PE with and without DVT in one patient each. After hospitalization, three patients required readmiss-ion for evacuation of a haematoma, one for wound drainage, and one for monitoring of an elevated international normalized ratio (INR). Seven patients died (2.5%). One patient died five months postoperatively of a PE during open thrombectomy. She had discontinued anticoagulation. One patient died of a haemorrhagic stroke while receiving Coumadin. PE or bleeding was not suspected in the remaining five fatalities. Conclusion. Multimodal prophylaxis is safe and effective in patients with a history of VTE. Postoperative anticoagulation should be prudent as very few patients developed VTE (2.5%) or died of suspected or confirmed PE. Mortality during the first year was mostly unrelated to either VTE or bleeding. Cite this article: Bone Joint J 2020;102-B(7 Supple B):71–77


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 113 - 121
1 Jan 2012
Poultsides LA Gonzalez Della Valle A Memtsoudis SG Ma Y Roberts T Sharrock N Salvati E

We performed a meta-analysis of modern total joint replacement (TJR) to determine the post-operative mortality and the cause of death using different thromboprophylactic regimens as follows: 1) no routine chemothromboprophylaxis (NRC); 2) Potent anticoagulation (PA) (unfractionated or low-molecular-weight heparin, ximelagatran, fondaparinux or rivaroxaban); 3) Potent anticoagulation combined (PAC) with regional anaesthesia and/or pneumatic compression devices (PCDs); 4) Warfarin (W); 5) Warfarin combined (WAC) with regional anaesthesia and/or PCD; and 6) Multimodal (MM) prophylaxis, including regional anaesthesia, PCDs and aspirin in low-risk patients. Cause of death was classified as autopsy proven, clinically certain or unknown. Deaths were grouped into cardiopulmonary excluding pulmonary embolism (PE), PE, bleeding-related, gastrointestinal, central nervous system, and others (miscellaneous). Meta-analysis based on fixed effects or random effects models was used for pooling incidence data. In all, 70 studies were included (99 441 patients; 373 deaths). The mortality was lowest in the MM (0.2%) and WC (0.2%) groups. The most frequent cause of death was cardiopulmonary (47.9%), followed by PE (25.4%) and bleeding (8.9%). The proportion of deaths due to PE was not significantly affected by the thromboprophylaxis regimen (PA, 35.5%; PAC, 28%; MM, 23.2%; and NRC, 16.3%). Fatal bleeding was higher in groups relying on the use of anticoagulation (W, 33.8%; PA, 9.4%; PAC, 10.8%) but the differences were not statistically significant. Our study demonstrated that the routine use of PA does not reduce the overall mortality or the proportion of deaths due to PE


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 1057 - 1066
1 Nov 1998
Westrich GH Specht LM Sharrock NE Windsor RE Sculco TP Haas SB Trombley JF Peterson M

We performed a crossover study to evaluate the haemodynamic effect of active dorsal to plantar flexion and seven pneumatic compression devices in ten patients who had a total knee arthroplasty. Using the Acuson 128XP/10 duplex ultrasound unit with a 5MHz linear array probe, we assessed the augmentation of peak venous velocity and venous volume above and below the junction of the greater saphenous and common femoral veins in order to study both the deep and superficial venous systems. The pneumatic compression devices evaluated included two foot pumps (A-V Impulse System and PlexiPulse Foot), a foot-calf pump (PlexiPulse Foot-Calf), a calf pump (VenaFlow System) and three calf-thigh pumps (SCD System, Flowtron DVT and Jobst Athrombic Pump). The devices differed in a number of ways, including the length and location of the sleeve and bladder, the frequency and duration of activation, the rate of pressure rise, and the maximum pressure achieved. A randomisation table was used to determine the order of the test conditions for each patient. The enhancement of peak venous velocity occurred primarily in the deep venous system below the level of the saphenofemoral junction. The increases in peak venous velocity were as follows: active dorsal to plantar flexion 175%; foot pumps, A-V Impulse System 29% and PlexiPulse 65%; foot-calf pump, PlexiPulse, 221%; calf pump, VenaFlow, 302% and calf-thigh pumps, Flowtron DVT 87%, SCD System 116% and Jobst Athrombic Pump 263%. All the devices augmented venous volume, the greatest effect being seen with those incorporating calf compression. The increases in ml/min were found in the deep venous system as follows: foot pumps, A-V Impulse System 9.6 and PlexiPulse Foot 16.7; foot-calf pump, PlexiPulse, 38.1; calf pump, VenaFlow, 26.2; calf-thigh pumps, Flowtron DVT 61.5, SCD System 34.7 and Jobst Athrombic Pump 82.3. Active dorsal to plantar flexion generated 8.5 ml for a single calf contraction


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 171 - 177
1 May 1981
Sikorski J Hampson W Staddon G

A study of the natural history and aetiology of deep vein thrombosis in 499 patients after total hip replacement is presented. Deep vein thrombosis was diagnosed by scanning the leg for 125Iodine-labelled fibrinogen for a period of 14 to 18 days and by ascending phlebography. It has been shown that deep vein thrombosis occurs ater than in patients who have undergone abdominal operations, and the risk period is longer. The peak of onset of thrombosis is on the fourth day after the hip replacement. Attempts at prophylaxis using subcutaneous heparin or intermittent pneumatic compression of the calves delay the appearance of thrombosis. Analysis of possible aetiology factors shows that the age of the patient, the degenerative disease of the hip, the surgical approach, and under-transfusion of blood, all have a significant effect on the incidence of thrombosis


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 562 - 569
1 May 2008
Daniel J Pradhan A Pradhan C Ziaee H Moss M Freeman J McMinn DJW

We report a retrospective review of the incidence of venous thromboembolism in 463 consecutive patients who underwent primary total hip arthroplasty (487 procedures). Treatment included both total hip replacement and hip resurfacing, and the patients were managed without anticoagulants. The thromboprophylaxis regimen included an antiplatelet agent, generally aspirin, hypotensive epidural anaesthesia, elastic compression stockings and early mobilisation. In 258 of these procedures (244 patients) performed in 2005 (cohort A) mechanical compression devices were not used, whereas in 229 (219 patients) performed during 2006 (cohort B) bilateral intermittent pneumatic calf compression was used. All operations were performed through a posterior mini-incision approach. Patients who required anticoagulation for pre-existing medical problems and those undergoing revision arthroplasty were excluded. Doppler ultrasonographic screening for deep-vein thrombosis was performed in all patients between the fourth and sixth post-operative days. All patients were reviewed at a follow-up clinic six to ten weeks after the operation. In addition, reponse to a questionnaire was obtained at the end of 12 weeks post-operatively. No symptomatic calf or above-knee deep-vein thrombosis or pulmonary embolism occurred. In 25 patients in cohort A (10.2%) and in ten patients in cohort B (4.6%) asymptomatic calf deep-vein thromboses were detected ultrasonographically. This difference was statistically significant (p = 0.03). The regimen followed by cohort B offers the prospect of a low incidence of venous thromboembolism without subjecting patients to the higher risk of bleeding associated with anticoagulant use


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 229 - 233
1 Mar 1999
Ramesh M Morrissey B Healy JB Roy-Choudhury S Macey AC

Acute swelling of the hand is a common problem after trauma or surgery and is associated with both pain and loss of function. We describe a prospective study of 47 patients in which we assessed the effects of a pneumatic compression device (A-V impulse hand pump) on the swollen hand. The pump reduced swelling by increasing the velocity of venous return as demonstrated by Duplex scanning of the median cubital vein. Continuous use of the pump for 48 hours gave a reduction of 78.6% in swelling of the injured hand compared with the opposite, uninjured side. Even when used intermittently, with the pump on for 12 hours out of 24, a statistically significant effect was seen. There was a subjective reduction in pain and an objective improvement in function of the hand. Use of the pump resulted in a nearly normal hand by the time of discharge from hospital after, on average, 48 hours


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1137 - 1141
1 Nov 2004
Lachiewicz PF Kelley SS Haden LR

The optimal characteristics of pneumatic compression for mechanical prophylaxis of thromboembolism after total knee arthroplasty (TKA) are not known. Our study compared two methods of calf compression, with the hypothesis that the device which provided a larger increase in peak venous velocity would produce a lower rate of thromboembolism. We performed a prospective, randomised study on 423 patients (472 knees). Duplex ultrasonography was carried out by experienced technicians who were blinded to the device used. Overall, 206 patients (232 knees) used a rapid inflation, asymmetrical compression (RIAC) device and 217 (240 knees) a sequential circumferential compression device (SCD). The rate of venous thromboembolism was 6.9% with the RIAC device compared with 15% for the SCD device (p = 0.007). The incidence of thrombi with unilateral primary TKA was 8.4% for the RIAC compared with 16.8% for the SCD device (p = 0.03). In 47 patients with a bilateral TKA, the incidence of thrombi was 4% for the RIAC compared with 22.7% for the SCD device (p = 0.05 per knee). There was a low rate of mortality and pulmonary embolism when using mechanical prophylaxis for thromboembolism after TKA. Our findings show that the use of rapid inflation, asymmetrical calf compression gave a significantly lower rate of thromboembolism


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 639 - 642
1 Jul 2004
Pitto RP Hamer H Heiss-Dunlop W Kuehle J

Routine prophylaxis for venous thromboembolic disease after total hip replacement (THR) is recommended. Pneumatic compression with foot pumps seems to provide an alternative to chemical agents. However, the overall number of patients investigated in randomised clinical trials has been too small to draw evidence-based conclusions. This randomised clinical trial was carried out to compare the effectiveness and safety of mechanical versus chemical prophylaxis of DVT in patients after THR. Inclusion criteria were osteoarthritis of the hip and age less than 80 years. Exclusion criteria included a history of thromboembolic disease, heart disease, and bleeding diatheses. There were 216 consecutive patients considered for inclusion in the trial who were randomised either for management with the A-V Impulse System foot pump. We excluded 16 patients who did not tolerate continuous use of the foot pump or with low-molecular-weight heparin (LMWH). Patients were monitored for DVT using serial duplex sonography at 3, 10 and 45 days after surgery. DVT was detected in three of 100 patients in the foot-pump group and with six of 100 patients in the LMWH group (p < 0.05). The mean post-operative drainage was 259 ml in the foot-pump group and 328 ml in the LMWH group (p < 0.05). Patients in the foot-pump group had less swelling of the thigh (10 mm compared with 15 mm; p < 0.05). One patient developed heparin-induced thrombocytopenia. This study confirms the effectiveness and safety of mechanical prophylaxis of DVT in THR. Some patients cannot tolerate the foot pump


Aims

The aim of this study was to evaluate the healthcare costs and benefits of enoxaparin compared to aspirin in the prevention of symptomatic venous thromboembolism (VTE) after total hip arthroplasty (THA) or total knee arthroplasty (TKA) using data from the CRISTAL trial.

Methods

This trial-based economic analysis reports value for money as incremental cost per quality-adjusted life-year (QALY) gained in 2022 Australian dollars, compared to a single threshold value of AUD$70,000 per QALY. Event costs were estimated based on occurrence of VTEs and bleeds, and on published guidelines for treatment. Unit costs were taken from Australian sources. QALYs were estimated using CRISTAL six-month follow-up data. Sensitivity analyses are presented that vary the cost of VTE treatment, and extend the analyses to two years.


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1743 - 1751
1 Dec 2020
Lex JR Evans S Cool P Gregory J Ashford RU Rankin KS Cosker T Kumar A Gerrand C Stevenson J

Aims

Malignancy and surgery are risk factors for venous thromboembolism (VTE). We undertook a systematic review of the literature concerning the prophylactic management of VTE in orthopaedic oncology patients.

Methods

MEDLINE (PubMed), EMBASE (Ovid), Cochrane, and CINAHL databases were searched focusing on VTE, deep vein thrombosis (DVT), pulmonary embolism (PE), bleeding, or wound complication rates.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 746 - 754
1 Apr 2021
Schnetzke M El Barbari J Schüler S Swartman B Keil H Vetter S Gruetzner PA Franke J

Aims

Complex joint fractures of the lower extremity are often accompanied by soft-tissue swelling and are associated with prolonged hospitalization and soft-tissue complications. The aim of the study was to evaluate the effect of vascular impulse technology (VIT) on soft-tissue conditioning in comparison with conventional elevation.

Methods

A total of 100 patients were included in this prospective, randomized, controlled monocentre study allocated to the three subgroups of dislocated ankle fracture (n = 40), pilon fracture (n = 20), and intra-articular calcaneal fracture (n = 40). Patients were randomized to the two study groups in a 1:1 ratio. The effectiveness of VIT (intervention) compared with elevation (control) was analyzed separately for the whole study population and for the three subgroups. The primary endpoint was the time from admission until operability (in days).


Aims

Intravenous dexamethasone has been shown to reduce immediate postoperative pain after total hip arthroplasty (THA), though the effects are short-lived. We aimed to assess whether two equivalent perioperative split doses were more effective than a single preoperative dose.

Methods

A total of 165 patients were randomly assigned into three groups: two perioperative saline injections (Group A, placebo), a single preoperative dose of 20 mg dexamethasone and a postoperative saline injection (Group B), and two perioperative doses of 10 mg dexamethasone (Group C). Patients, surgeons, and staff collecting outcome data were blinded to allocation. The primary outcome was postoperative pain level reported on a ten-point Numerical Rating Scale (NRS) at rest and during activity. The use of analgesic and antiemetic rescue, incidence of postoperative nausea and vomiting (PONV), CRP and interleukin-6 (IL-6) levels, range of motion (ROM), length of stay (LOS), patient satisfaction, and the incidence of surgical site infection (SSI) and gastrointestinal bleeding (GIB) in the three months postoperatively, were also compared.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 155 - 161
1 Feb 2020
McMahon SE Diamond OJ Cusick LA

Aims

Complex displaced osteoporotic acetabular fractures in the elderly are associated with high levels of morbidity and mortality. Surgical options include either open reduction and internal fixation alone, or combined with total hip arthroplasty (THA). There remains a cohort of severely comorbid patients who are deemed unfit for extensive surgical reconstruction and are treated conservatively. We describe the results of a coned hemipelvis reconstruction and THA inserted via a posterior approach to the hip as the primary treatment for this severely high-risk cohort.

Methods

We have prospectively monitored a series of 22 cases (21 patients) with a mean follow-up of 32 months (13 to 59).


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1056 - 1061
1 Aug 2016
Wilson DGG Poole WEC Chauhan SK Rogers BA

Aims

There is uncertainty regarding the optimal means of thromboprophylaxis following total hip and knee arthroplasty (THA, TKA). This systematic review presents the evidence for acetylsalicylic acid (aspirin) as a thromboprophylactic agent in THA and TKA and compares it with other chemoprophylactic agents.

Materials and Methods

A search of literature published between 2004 and 2014 was performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A total of 13 studies were eligible for inclusion.