Advertisement for orthosearch.org.uk
Results 1 - 20 of 90
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1060 - 1065
1 Aug 2018
Hwang J Shields MN Berglund LJ Hooke AW Fitzsimmons JS O’Driscoll SW

Aims. The aim of this study was to evaluate two hypotheses. First, that disruption of posterior bundle of the medial collateral ligament (PMCL) has to occur for the elbow to subluxate in cases of posteromedial rotatory instability (PMRI) and second, that ulnohumeral contact pressures increase after disruption of the PMCL. Materials and Methods. Six human cadaveric elbows were prepared on a custom-designed apparatus which allowed muscle loading and passive elbow motion under gravitational varus. Joint contact pressures were measured sequentially in the intact elbow (INTACT), followed by an anteromedial subtype two coronoid fracture (COR), a lateral collateral ligament (LCL) tear (COR + LCL), and a PMCL tear (COR + LCL + PMCL). Results. There was no subluxation or joint incongruity in the INTACT, COR, and COR + LCL specimens. All specimens in the COR + LCL + PMCL group subluxated under gravity-varus loads. The mean articular contact pressure of the COR + LCL group was significantly higher than those in the INTACT and the COR groups. The mean articular contact pressure of the COR + LCL + PMCL group was significantly higher than that of the INTACT group, but not higher than that of the COR + LCL group. Conclusion. In the presence of an anteromedial fracture and disruption of the LCL, the posterior bundle of the MCL has to be disrupted for gross subluxation of the elbow to occur. However, elevated joint contact pressures are seen after an anteromedial fracture and LCL disruption even in the absence of such subluxation. Cite this article: Bone Joint J 2018;100-B:1060–5


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 842 - 848
1 Aug 2024
Kriechling P Whitefield R Makaram NS Brown IDM Mackenzie SP Robinson CM

Aims. Vascular compromise due to arterial injury is a rare but serious complication of a proximal humeral fracture. The aims of this study were to report its incidence in a large urban population, and to identify clinical and radiological factors which are associated with this complication. We also evaluated the results of the use of our protocol for the management of these injuries. Methods. A total of 3,497 adult patients with a proximal humeral fracture were managed between January 2015 and December 2022 in a single tertiary trauma centre. Their mean age was 66.7 years (18 to 103) and 2,510 (72%) were female. We compared the demographic data, clinical features, and configuration of those whose fracture was complicated by vascular compromise with those of the remaining patients. The incidence of vascular compromise was calculated from national population data, and predictive factors for its occurrence were investigated using univariate analysis. Results. A total of 18 patients (0.5%) had a proximal humeral fracture and clinical evidence of vascular compromise, giving an annual incidence of 0.29 per 100,000 of the population. Their mean age was 68.7 years (45 to 92) and ten (56%) were female. Evidence of a mixed pattern neurological deficit (brachial plexus palsy) (odds ratio (OR) 380.6 (95% CI 85.9 to 1,685.8); p < 0.001), complete separation of the proximal shaft from the humeral head with medial displacement (OR 39.5 (95% CI 14.0 to 111.8); p < 0.001), and a fracture-dislocation (OR 5.0 (95% CI 1.6 to 15.3); p = 0.015) were all associated with an increased risk of associated vascular compromise. A policy of reduction and fixation of the fracture prior to vascular surgical intervention had favourable outcomes without vascular sequelae. Conclusion. The classic signs of distal ischaemia are often absent in patients with proximal injuries to major vessels. We were able to identify specific clinical and radiological ‘red flags’ which, particularly when present in combination, should increase the suspicion of a fracture with an associated vascular injury, and facilitate early diagnosis and appropriate combined orthopaedic and vascular intervention. Cite this article: Bone Joint J 2024;106-B(8):842–848


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 56 - 63
1 Jan 2023
de Klerk HH Oosterhoff JHF Schoolmeesters B Nieboer P Eygendaal D Jaarsma RL IJpma FFA van den Bekerom MPJ Doornberg JN

Aims. This study aimed to answer the following questions: do 3D-printed models lead to a more accurate recognition of the pattern of complex fractures of the elbow?; do 3D-printed models lead to a more reliable recognition of the pattern of these injuries?; and do junior surgeons benefit more from 3D-printed models than senior surgeons?. Methods. A total of 15 orthopaedic trauma surgeons (seven juniors, eight seniors) evaluated 20 complex elbow fractures for their overall pattern (i.e. varus posterior medial rotational injury, terrible triad injury, radial head fracture with posterolateral dislocation, anterior (trans-)olecranon fracture-dislocation, posterior (trans-)olecranon fracture-dislocation) and their specific characteristics. First, fractures were assessed based on radiographs and 2D and 3D CT scans; and in a subsequent round, one month later, with additional 3D-printed models. Diagnostic accuracy (acc) and inter-surgeon reliability (κ) were determined for each assessment. Results. Accuracy significantly improved with 3D-printed models for the whole group on pattern recognition (acc. 2D/3D. = 0.62 vs acc. 3Dprint. = 0.69; Δacc = 0.07 (95% confidence interval (CI) 0.00 to 0.14); p = 0.025). A significant improvement was also seen in reliability for pattern recognition with the additional 3D-printed models (κ. 2D/3D. = 0.41 (moderate) vs κ. 3Dprint. = 0.59 (moderate); Δκ = 0.18 (95% CI 0.14 to 0.22); p ≤ 0.001). Accuracy was comparable between junior and senior surgeons with the 3D-printed model (acc. junior. = 0.70 vs acc. senior. = 0.68; Δacc = -0.02 (95% CI -0.17 to 0.13); p = 0.904). Reliability was also comparable between junior and senior surgeons without the 3D-printed model (κ. junior. = 0.39 (fair) vs κ. senior. = 0.43 (moderate); Δκ = 0.03 (95% CI -0.03 to 0.10); p = 0.318). However, junior surgeons showed greater improvement regarding reliability than seniors with 3D-printed models (κ. junior. = 0.65 (substantial) vs κ. senior. = 0.54 (moderate); Δκ = 0.11 (95% CI 0.04 to 0.18); p = 0.002). Conclusion. The use of 3D-printed models significantly improved the accuracy and reliability of recognizing the pattern of complex fractures of the elbow. However, the current long printing time and non-reusable materials could limit the usefulness of 3D-printed models in clinical practice. They could be suitable as a reusable tool for teaching residents. Cite this article: Bone Joint J 2023;105-B(1):56–63


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1629 - 1635
1 Dec 2020
Wang Q Sheng N Rui B Chen Y

Aims. The aim of this study was to explore why some calcar screws are malpositioned when a proximal humeral fracture is treated by internal fixation with a locking plate, and to identify risk factors for this phenomenon. Some suggestions can be made of ways to avoid this error. Methods. We retrospectively identified all proximal humeral fractures treated in our institution between October 2016 and October 2018 using the hospital information system. The patients’ medical and radiological data were collected, and we divided potential risk factors into two groups: preoperative factors and intraoperative factors. Preoperative factors included age, sex, height, weight, body mass index, proximal humeral bone mineral density, type of fracture, the condition of the medial hinge, and medial metaphyseal head extension. Intraoperative factors included the grade of surgeon, neck-shaft angle after reduction, humeral head height, restoration of medial support, and quality of reduction. Adjusted binary logistic regression and multivariate logistic regression models were used to identify pre- and intraoperative risk factors. Area under the curve (AUC) analysis was used to evaluate the discriminative ability of the multivariable model. Results. Data from 203 patients (63 males and 140 females) with a mean age of 62 years (22 to 89) were analyzed. In 49 fractures, the calcar screw was considered to be malpositioned; in 154 it was in the optimal position. The rate of malpositioning was therefore 24% (49/203). No preoperative risk factor was found for malpositioning of the calcar screws. Only the neck-shaft angle was found to be related to the risk of screw malpositioning in a multivariate model (with an AUC of 0.72). For the fractures in which the neck-shaft angle was reduced to between 130° and 150°, 91% (133/46) of calcar screws were in the optimal position. Conclusion. The neck-shaft angle is the key factor for the appropriate positioning of calcar screws when treating a proximal humeral fracture with a locking plate. We recommend reducing the angle to between 130° and 150°. Cite this article: Bone Joint J 2020;102-B(12):1629–1635


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 881 - 889
1 Jul 2020
Frank FA Niehaus R Borbas P Eid K

Aims. Conservative treatment of moderately displaced proximal humeral head fractures yields good clinical results, but secondary fragment displacement may occur. Identification of those fractures at risk of displacement may influence initial decision-making. Methods. A total of 163 shoulders in 162 patients with conservatively treated isolated proximal humeral fractures were included. The fractures occurred between January 2015 and May 2018. The mean age of the patients was 69 years (26 to 100) and the mean follow-up was 144 days (42 to 779). The fractures were classified according to Neer. Scores for osteoporosis (Tingart, Deltoid Tuberosity Index (DTI)) and osteoarthritis (OA) of the glenohumeral joint were assessed. Translation of the head on follow-up radiographs of more than 10 mm was defined as displacement. Eccentric head index (EHI) describes the offset of the humeral head centre in relation to the diaphyseal axis. The ratio was estimated on anteroposterior (AP) and Neer views. Medial hinge was considered intact if the medial cortex proximal and distal to the fracture was in line on AP view. Results. Secondary fracture displacement occurred in 41 patients (25.2%). Clinical risk factors were alcohol abuse (odds ratio (OR) 6.8; 95% confidence interval (CI) 1.3 to 36; p = 0.025) and previously diagnosed osteoporosis (OR 4.6; 95% CI 0.6 to 34; p = 0.136). Age (OR 1.1; 95% CI 1.0 to 1.1; p = 0.003) and sex (OR 0.9; 95% CI 0.3 to 2.8; p = 0.867) were not independent factors. Radiological risk factors were OA grade 3 (OR 16.4; 95% CI 0.25 to 37.6; p = 0.107) and osteoporosis with the DTI (OR 10; 95% CI 0.8 to 250; p = 0.031) being more predictive than the Tingart score (OR 2.3; 95% CI 0.8 to 4.7; p = 0.041). A high EHI (AP/Neer > 0.4, OR 18.9; 95% CI 2.1 to 30.9/3.0; 95% CI 1.1 to 8.0; p = 0.002/p = 0.033) and a disrupted medial hinge (OR 3.7; 95% CI 1.1 to 12.6; p = 0.039) increased the risk of secondary displacement significantly. Neer classification had no influence. Conclusion. During conservative treatment, a quarter of patients showed secondary fracture displacement of at least 10 mm. Patients with alcohol abuse, severe OA, and osteoporosis are at risk. Newly defined EHI and disrupted medial hinge are relevant predictors for secondary displacement. Cite this article: Bone Joint J 2020;102-B(7):881–889


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 227 - 231
1 Feb 2020
Lee SH Nam DJ Yu HK Kim JW

Aims. The purpose of this study was to evaluate the relationships between the degree of injury to the medial and lateral collateral ligaments (MCL and LCL) and associated fractures in patients with a posterolateral dislocation of the elbow, using CT and MRI. Methods. We retrospectively reviewed 64 patients who presented between March 2009 and March 2018 with a posterolateral dislocation of the elbow and who underwent CT and MRI. CT revealed fractures of the radial head, coronoid process, and medial and lateral humeral epicondyles. MRI was used to identify contusion of the bone and collateral ligament injuries by tear, partial or complete tear. Results. A total of 54 patients had a fracture; some had more than one. Radial head fractures were found in 25 patients and coronoid fractures in 42. Lateral and medial humeral epicondylar fractures were found in eight and six patients, respectively. Contusion of the capitellum was found in 43 patients and rupture of the LCL was seen in all patients (partial in eight and complete in 56), there was complete rupture of the MCL in 37 patients, partial rupture in 19 and eight had no evidence of rupture. The LCL tear did not significantly correlate with the presence of fracture, but the MCL rupture was complete in patients with a radial head fracture (p = 0.047) and there was significantly increased association in those without a coronoid fracture (p = 0.015). Conclusion. In posterolateral dislocation of the elbow, LCL ruptures are mostly complete, while the MCL exhibits various degrees of injury, which are significantly associated with the associated fractures. Cite this article: Bone Joint J 2020;102-B(2):227–231


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1100 - 1110
1 Oct 2024
Arenas-Miquelez A Barco R Cabo Cabo FJ Hachem A

Bone defects are frequently observed in anterior shoulder instability. Over the last decade, knowledge of the association of bone loss with increased failure rates of soft-tissue repair has shifted the surgical management of chronic shoulder instability. On the glenoid side, there is no controversy about the critical glenoid bone loss being 20%. However, poor outcomes have been described even with a subcritical glenoid bone defect as low as 13.5%. On the humeral side, the Hill-Sachs lesion should be evaluated concomitantly with the glenoid defect as the two sides of the same bipolar lesion which interact in the instability process, as described by the glenoid track concept. We advocate adding remplissage to every Bankart repair in patients with a Hill-Sachs lesion, regardless of the glenoid bone loss. When critical or subcritical glenoid bone loss occurs in active patients (> 15%) or bipolar off-track lesions, we should consider anterior glenoid bone reconstructions. The techniques have evolved significantly over the last two decades, moving from open procedures to arthroscopic, and from screw fixation to metal-free fixation. The new arthroscopic techniques of glenoid bone reconstruction procedures allow precise positioning of the graft, identification, and treatment of concomitant injuries with low morbidity and faster recovery. Given the problems associated with bone resorption and metal hardware protrusion, the new metal-free techniques for Latarjet or free bone block procedures seem a good solution to avoid these complications, although no long-term data are yet available.

Cite this article: Bone Joint J 2024;106-B(10):1100–1110.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 970 - 977
1 Sep 2024
De Rus Aznar I Ávila Lafuente JL Hachem A Díaz Heredia J Kany J Elhassan B Ruiz Ibán MÁ

Rotator cuff pathology is the main cause of shoulder pain and dysfunction in older adults. When a rotator cuff tear involves the subscapularis tendon, the symptoms are usually more severe and the prognosis after surgery must be guarded. Isolated subscapularis tears represent 18% of all rotator cuff tears and arthroscopic repair is a good alternative primary treatment. However, when the tendon is deemed irreparable, tendon transfers are the only option for younger or high-functioning patients. The aim of this review is to describe the indications, biomechanical principles, and outcomes which have been reported for tendon transfers, which are available for the treatment of irreparable subscapularis tears.

The best tendon to be transferred remains controversial. Pectoralis major transfer was described more than 30 years ago to treat patients with failed surgery for instability of the shoulder. It has subsequently been used extensively to manage irreparable subscapularis tendon tears in many clinical settings. Although pectoralis major reproduces the position and orientation of the subscapularis in the coronal plane, its position in the axial plane – anterior to the rib cage – is clearly different and does not allow it to function as an ideal transfer. Consistent relief of pain and moderate recovery of strength and function have been reported following the use of this transfer. In an attempt to improve on these results, latissimus dorsi tendon transfer was proposed as an alternative and the technique has evolved from an open to an arthroscopic procedure. Satisfactory relief of pain and improvements in functional shoulder scores have recently been reported following its use. Both pectoralis minor and upper trapezius transfers have also been used in these patients, but the outcomes that have been reported do not support their widespread use.

Cite this article: Bone Joint J 2024;106-B(9):970–977.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims

This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA).

Methods

From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims

Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm.

Methods

An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 905 - 911
1 Aug 2023
Giannicola G Amura A Sessa P Prigent S Cinotti G

Aims

The aim of this study was to analyze how proximal radial neck resorption (PRNR) starts and progresses radiologically in two types of press-fit radial head arthroplasties (RHAs), and to investigate its clinical relevance.

Methods

A total of 97 patients with RHA were analyzed: 56 received a bipolar RHA (Group 1) while 41 received an anatomical implant (Group 2). Radiographs were performed postoperatively and after three, six, nine, and 12 weeks, six, nine, 12, 18, and 24 months, and annually thereafter. PRNR was measured in all radiographs in the four radial neck quadrants. The Mayo Elbow Performance Score (MEPS), the abbreviated version of the Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH), and the patient-assessed American Shoulder and Elbow Surgeons score - Elbow (pASES-E) were used for the clinical assessment. Radiological signs of implant loosening were investigated.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims

Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE.

Methods

This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1158 - 1164
1 Oct 2024
Jakobi T Krieg I Gramlich Y Sauter M Schnetz M Hoffmann R Klug A

Aims

The aim of this study was to evaluate the outcome of complex radial head fractures at mid-term follow-up, and determine whether open reduction and internal fixation (ORIF) or radial head arthroplasty (RHA) should be recommended for surgical treatment.

Methods

Patients who underwent surgery for complex radial head fractures (Mason type III, ≥ three fragments) were divided into two groups (ORIF and RHA) and propensity score matching was used to individually match patients based on patient characteristics. Ultimately, 84 patients were included in this study. After a mean follow-up of 4.1 years (2.0 to 9.5), patients were invited for clinical and radiological assessment. The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire score were evaluated.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1234 - 1241
1 Nov 2022
Park JH Park KT Kim SC Bukhary HA Lee SM Yoo JC

Aims

This study compared patients who underwent arthroscopic repair of large to massive rotator cuff tears (LMRCTs) with isolated incomplete repair of the tear and patients with incomplete repair with biceps tendon augmentation. We aimed to evaluate the additional benefit on clinical outcomes and the capacity to lower the re-tear rate.

Methods

We retrospectively reviewed 1,115 patients who underwent arthroscopic rotator cuff repair for full-thickness tears between October 2011 and May 2019. From this series, we identified 77 patients (28 male, 49 female) with a mean age of 64.1 years (50 to 80). Patients were classified into groups A (n = 47 incomplete) and B (n = 30 with biceps augmentation) according to the nature of their reconstruction. Clinical scores were checked preoperatively and at six months, one year, and two years postoperatively. In preoperative MRI, we measured the tear size, the degree of fatty infiltration, and muscle volume ratio of the supraspinatus. In postoperative MRI, the integrity of the repaired rotator cuff tendon was assessed using the Sugaya classification. Tendon thickness at the footprint was evaluated on T2-weighted oblique coronal view.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 957 - 963
1 Sep 2024
Baek CH Kim JG Kim BT

Aims

Favourable short-term outcomes have been reported following latissimus dorsi tendon transfer for patients with an irreparable subscapularis (SSC) tendon tear. The aim of this study was to investigate the long-term outcomes of this transfer in these patients.

Methods

This was a retrospective study involving 30 patients with an irreparable SSC tear and those with a SSC tear combined with a reparable supraspinatus tear, who underwent a latissimus dorsi tendon transfer. Clinical scores and active range of motion (aROM), SSC-specific physical examination and the rate of return to work were assessed. Radiological assessment included recording the acromiohumeral distance (AHD), the Hamada grade of cuff tear arthropathy and the integrity of the transferred tendon. Statistical analysis compared preoperative, short-term (two years), and final follow-up at a mean of 8.7 years (7 to 10).


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1133 - 1140
1 Oct 2024
Olsen Kipp J Petersen ET Falstie-Jensen T Frost Teilmann J Zejden A Jellesen Åberg R de Raedt S Thillemann TM Stilling M

Aims

This study aimed to quantify the shoulder kinematics during an apprehension-relocation test in patients with anterior shoulder instability (ASI) and glenoid bone loss using the radiostereometric analysis (RSA) method. Kinematics were compared with the patient’s contralateral healthy shoulder.

Methods

A total of 20 patients with ASI and > 10% glenoid bone loss and a healthy contralateral shoulder were included. RSA imaging of the patient’s shoulders was performed during a repeated apprehension-relocation test. Bone volume models were generated from CT scans, marked with anatomical coordinate systems, and aligned with the digitally reconstructed bone projections on the RSA images. The glenohumeral joint (GHJ) kinematics were evaluated in the anteroposterior and superoinferior direction of: the humeral head centre location relative to the glenoid centre; and the humeral head contact point location on the glenoid.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1150 - 1157
1 Oct 2024
de Klerk HH Verweij LPE Doornberg JN Jaarsma RL Murase T Chen NC van den Bekerom MPJ

Aims

This study aimed to gather insights from elbow experts using the Delphi method to evaluate the influence of patient characteristics and fracture morphology on the choice between operative and nonoperative treatment for coronoid fractures.

Methods

A three-round electronic (e-)modified Delphi survey study was performed between March and December 2023. A total of 55 elbow surgeons from Asia, Australia, Europe, and North America participated, with 48 completing all questionnaires (87%). The panellists evaluated the factors identified as important in literature for treatment decision-making, using a Likert scale ranging from "strongly influences me to recommend nonoperative treatment" (1) to "strongly influences me to recommend operative treatment" (5). Factors achieving Likert scores ≤ 2.0 or ≥ 4.0 were deemed influential for treatment recommendation. Stable consensus is defined as an agreement of ≥ 80% in the second and third rounds.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims

The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes.

Methods

This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group).


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1148 - 1155
1 Oct 2022
Watts AC Hamoodi Z McDaid C Hewitt C

Aims

Arthroplasties of the elbow, including total elbow arthroplasty, radial head arthroplasty, distal humeral hemiarthroplasty, and radiocapitellar arthroplasty, are rarely undertaken. This scoping review aims to outline the current research in this area to inform the development of future research.

Methods

A scoping review was undertaken adhering to the Joanna Briggs Institute guidelines using Medline, Embase, CENTRAL, and trial registries, limited to studies published between 1 January 1990 and 7 February 2021. Endnote software was used for screening and selection, and included randomized trials, non-randomized controlled trials, prospective and retrospective cohort studies, case-control studies, analytical cross-sectional studies, and case series of ten or more patients reporting the clinical outcomes of elbow arthroplasty. The results are presented as the number of types of studies, sample size, length of follow-up, clinical outcome domains and instruments used, sources of funding, and a narrative review.


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 486 - 494
4 Apr 2022
Liu W Sun Z Xiong H Liu J Lu J Cai B Wang W Fan C

Aims

The aim of this study was to develop and internally validate a prognostic nomogram to predict the probability of gaining a functional range of motion (ROM ≥ 120°) after open arthrolysis of the elbow in patients with post-traumatic stiffness of the elbow.

Methods

We developed the Shanghai Prediction Model for Elbow Stiffness Surgical Outcome (SPESSO) based on a dataset of 551 patients who underwent open arthrolysis of the elbow in four institutions. Demographic and clinical characteristics were collected from medical records. The least absolute shrinkage and selection operator regression model was used to optimize the selection of relevant features. Multivariable logistic regression analysis was used to build the SPESSO. Its prediction performance was evaluated using the concordance index (C-index) and a calibration graph. Internal validation was conducted using bootstrapping validation.