Advertisement for orthosearch.org.uk
Results 1 - 20 of 258
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 940 - 945
1 Jul 2005
Pandit H Ward T Hollinghurst D Beard DJ Gill HS Thomas NP Murray DW

Abnormal sagittal kinematics after total knee replacement (TKR) can adversely affect functional outcome. Two important determinants of knee kinematics are component geometry and the presence or absence of a posterior-stabilising mechanism (cam-post). We investigated the influence of these variables by comparing the kinematics of a TKR with a polyradial femur with a single radius design, both with and without a cam-post mechanism. We assessed 55 patients, subdivided into four groups, who had undergone a TKR one year earlier by using an established fluoroscopy protocol in order to examine their kinematics in vivo. The kinematic profile was obtained by measuring the patellar tendon angle through the functional knee flexion range (0° to 90°) and the results compared with 14 normal knees. All designs of TKR had abnormal sagittal kinematics compared with the normal knee. There was a significant (p < 0.05) difference between those of the two TKRs near to full extension. The presence of the cam-post mechanism did not influence the kinematics for either TKR design. These differences suggest that surface geometry is a stronger determinant of kinematics than the presence or absence of a cam-post mechanism for these two designs. This may be because the cam-post mechanism is ineffective


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 116 - 119
1 Nov 2012
Rosenberg AG

Disruption of the extensor mechanism in total knee arthroplasty may occur by tubercle avulsion, patellar or quadriceps tendon rupture, or patella fracture, and whether occurring intra-operatively or post-operatively can be difficult to manage and is associated with a significant rate of failure and associated complications. This surgery is frequently performed in compromised tissues, and repairs must frequently be protected with cerclage wiring and/or augmentation with local tendon (semi-tendinosis, gracilis) which may also be used to treat soft-tissue loss in the face of chronic disruption. Quadriceps rupture may be treated with conservative therapy if the patient retains active extension. Component loosening or loss of active extension of 20° or greater are clear indications for surgical treatment of patellar fracture. Acute patellar tendon disruption may be treated by primary repair. Chronic extensor failure is often complicated by tissue loss and retraction can be treated with medial gastrocnemius flaps, achilles tendon allografts, and complete extensor mechanism allografts. Attention to fixing the graft in full extension is mandatory to prevent severe extensor lag as the graft stretches out over time


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1162 - 1166
1 Nov 2000
Davies AP Costa ML Donnell ST Glasgow MM Shepstone L

Anterior knee pain due to dysplasia of the extensor mechanism is common. We have studied 137 knees (103 patients) in order to identify a rapid and reproducible radiological feature which would indicate the need for further analysis. Overall, 67 knees (49%) had at least one radiological abnormality; 70 (51%) were considered normal. There were five cases of Dejour type-3 dysplasia of the femoral trochlea, nine of type-2 and 12 of type-1. There were 49 cases of patella alta and five of patella infera. Four knees had an abnormal lateral patellofemoral angle (patellar tilt), and in 15 knees there was more than one abnormality. Classification of trochlear dysplasia was difficult and showed poor reproducibility. This was also true for the measurement of the lateral patellofemoral angle. Patellar height was more easily measured but took time. The sulcus angle is an easily and rapidly measurable feature which was reproducible and was closely related to other features of dysplasia of the extensor mechanism. The finding of a normal sulcus angle suggested that seeking other radiological evidence of malalignment of the extensor mechanism was unlikely to reveal additional useful information. The severity of other features of dysplasia of the extensor mechanism correlated with increasing sulcus angle


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 911 - 914
1 Jul 2007
Khan WS Nokes L Jones RK Johnson DS

We describe the influence of the angle of immobilisation during partial weight-bearing on the forces across the extensor mechanism of the knee. Gait analysis was performed on eight healthy male subjects with the right knee in an orthotic brace locked at 0°, 10°, 20° and 30°, with the brace unlocked and also without a brace. The ground reaction force, the angle of the knee and the net external flexion movement about the knee were measured and the extensor mechanism force was calculated. The results showed a direct non-linear relationship between the angle of knee flexion and the extensor mechanism force. When a brace was applied, the lowest forces occurred when the brace was locked at 0°. At 30° the forces approached the failure strength of some fixation devices. We recommend that for potentially unstable injuries of the extensor mechanism, when mobilising with partial weight-bearing, the knee should be flexed at no more than 10°


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 986 - 990
1 Sep 2004
Burnett RSJ Fornasier VL Haydon CM Wehrli BM Whitewood CN Bourne RB

We present the histological findings of an extensor mechanism allograft which was used in a total knee arthroplasty two years after implantation. Analysis of the graft was undertaken at four distinct anatomical levels and it was found to be incorporated into host tissue at each level. A wedge of fibrinoid necrosis, probably related to impingement of the graft on the tibial polyethylene insert, was seen. Impingement may play a role in the injury and necrosis of an allograft and may be one mode of failure in an extensor mechanism allograft


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 483 - 488
1 Apr 2005
Nakayama K Matsuda S Miura H Higaki H Otsuka K Iwamoto Y

We measured the contact areas and contact stresses at the post-cam mechanism of a posterior-stabilised total knee arthroplasty when a posterior force of 500 N was applied to the Kirschner Performance, Scorpio Superflex, NexGen LPS Flex Fixed, and NexGen LPS Flex Mobile knee systems. Measurements were made at 90°, 120°, and 150° of flexion both in neutral rotation and 10° of internal rotation of the tibial component. Peak contact stresses at 90°, 120°, and 150° were 24.0, 33.9, and 28.8 MPa, respectively, for the Kirschner; 26.0, 32.4, and 22.1 MPa, respectively, for the Scorpio; and 34.1, 31.5, and 32.5 MPa, respectively, for the NexGen LPS Flex Fixed. With an internally rotated tibia, the contact stress increased significantly with all the fixed-bearing arthroplasties but not with the NexGen LPS Flex Mobile arthroplasty. The post-cam design should be modified in order to provide a larger contact area whilst avoiding any impingement and edge loading


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1063 - 1069
1 Aug 2015
Pilge H Holzapfel BM Rechl H Prodinger PM Lampe R Saur U Eisenhart-Rothe R Gollwitzer H

The aim of this study was to analyse the gait pattern, muscle force and functional outcome of patients who had undergone replacement of the proximal tibia for tumour and alloplastic reconstruction of the extensor mechanism using the patellar-loop technique. Between February 1998 and December 2009, we carried out wide local excision of a primary sarcoma of the proximal tibia, proximal tibial replacement and reconstruction of the extensor mechanism using the patellar-loop technique in 18 patients. Of these, nine were available for evaluation after a mean of 11.6 years (0.5 to 21.6). The strength of the knee extensors was measured using an Isobex machine and gait analysis was undertaken in our gait assessment laboratory. Functional outcome was assessed using the American Knee Society (AKS) and Musculoskeletal Tumor Society (MSTS) scores. The gait pattern of the patients differed in ground contact time, flexion heel strike, maximal flexion loading response and total sagittal plane excursion. The mean maximum active flexion was 91° (30° to 110°). The overall mean extensor lag was 1° (0° to 5°). The mean extensor muscle strength was 25.8% (8.3% to 90.3%) of that in the non-operated leg (p < 0.001). The mean functional scores were 68.7% (43.4% to 83.3%) (MSTS) and 71.1 (30 to 90) (AKS functional score). In summary, the results show that reconstruction of the extensor mechanism using this technique gives good biomechanical and functional results. The patients’ gait pattern is close to normal, except for a somewhat stiff knee gait pattern. The strength of the extensor mechanism is reduced, but sufficient for walking. . Cite this article: Bone Joint J 2015;97-B:1063–9


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 856 - 857
1 Aug 2002
Herald J Cooper L Machart F

Many knee surgeons flex the knee and sometimes also extend the hip before inflating a tourniquet on the thigh. This practice stems from the belief that these manoeuvres prevent excessive strain on the quadriceps during surgery, the assumption being that movement of the muscle is restricted by an inflated tourniquet. We therefore examined, using ultrasound, the movement of the quadriceps muscle above and below the tourniquet before and after inflation.

We applied a tourniquet of standard size to the thigh of five volunteers for approximately five minutes. A bubble of air was injected into the quadriceps muscle above the tourniquet and was the proximal point of reference. The musculotendinous junction was the distal point. The movement of the reference point was measured by ultrasound before and after inflation of the tourniquet. Each measurement was repeated with either the knee flexed and the hip extended, or the hip flexed and the knee extended. The mean and standard deviation were recorded.

Before inflation the mean amount of passive movement was 1.1 ± 0.13 cm proximal and 4.0 ± 0.08 cm distal to the tourniquet, with a range of movement of the knee of 0° to 137° (6.7°). After inflation the mean passive movement was 1.0 ± 0.07 cm proximal and 4.0 ± 0.08 cm distal to the tourniquet with a range of 0° to 132° (± 7.6°).

The ultrasound findings therefore have shown no evidence of restriction of the quadriceps muscle by an inflated tourniquet.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1078 - 1085
1 Oct 2023
Cance N Batailler C Shatrov J Canetti R Servien E Lustig S

Aims. Tibial tubercle osteotomy (TTO) facilitates surgical exposure and protects the extensor mechanism during revision total knee arthroplasty (rTKA). The purpose of this study was to determine the rates of bony union, complications, and reoperations following TTO during rTKA, to assess the functional outcomes of rTKA with TTO at two years’ minimum follow-up, and to identify the risk factors of failure. Methods. Between January 2010 and September 2020, 695 rTKAs were performed and data were entered into a prospective database. Inclusion criteria were rTKAs with concomitant TTO, without extensor mechanism allograft, and a minimum of two years’ follow-up. A total of 135 rTKAs were included, with a mean age of 65 years (SD 9.0) and a mean BMI of 29.8 kg/m. 2. (SD 5.7). The most frequent indications for revision were infection (50%; 68/135), aseptic loosening (25%; 34/135), and stiffness (13%; 18/135). Patients had standardized follow-up at six weeks, three months, six months, and annually thereafter. Complications and revisions were evaluated at the last follow-up. Functional outcomes were assessed using the Knee Society Score (KSS) and range of motion. Results. The mean follow-up was 51 months (SD 26; 24 to 121). Bony union was confirmed in 95% of patients (128/135) at a mean of 3.4 months (SD 2.7). The complication rate was 15% (20/135), consisting of nine tibial tubercle fracture displacements (6.7%), seven nonunions (5%), two delayed unions, one tibial fracture, and one wound dehiscence. Seven patients (5%) required eight revision procedures (6%): three bone grafts, three osteosyntheses, one extensor mechanism allograft, and one wound revision. The functional scores and flexion were significantly improved after surgery: mean KSS knee, 48.8 (SD 17) vs 79.6 (SD 20; p < 0.001); mean KSS function, 37.6 (SD 21) vs 70.2 (SD 30; p < 0.001); mean flexion, 81.5° (SD 33°) vs 93° (SD 29°; p = 0.004). Overall, 98% of patients (n = 132) had no extension deficit. The use of hinge implants was a significant risk factor for tibial tubercle fracture (p = 0.011). Conclusion. TTO during rTKA was an efficient procedure to improve knee exposure with a high union rate, but had significant specific complications. Functional outcomes were improved at mid term. Cite this article: Bone Joint J 2023;105-B(10):1078–1085


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 35 - 46
1 Jan 2023
Mills K Wymenga AB Bénard MR Kaptein BL Defoort KC van Hellemondt GG Heesterbeek PJC

Aims. The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA). Methods. A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively. Femorotibial contact point (CP) locations were determined at every flexion angle and compared between the groups. RSA images were taken at baseline, six weeks, three, six, 12, and 24 months postoperatively. Clinical and functional outcomes were compared postoperatively for two years. Results. The BCR-TKA demonstrated a kinematic pattern comparable to the natural knee’s screw-home mechanism in the step-up task. In the lunge task, the medial CP of the BCR-TKA was more anterior in the early flexion phase, while laterally the CP was more posterior during the entire movement cycle. The BCR-TKA group showed higher tibial migration. No differences were found for the clinical and functional outcomes. Conclusion. The BCR-TKA shows a different kinematic pattern in early flexion/late extension compared to the CR-TKA. The difference between both implants is mostly visible in the flexion phase in which the anterior cruciate ligament is effective; however, both designs fail to fully replicate the motion of a natural knee. The higher migration of the BCR-TKA was concerning and highlights the importance of longer follow-up. Cite this article: Bone Joint J 2023;105-B(1):35–46


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1791 - 1801
1 Dec 2021
Bhalekar RM Nargol ME Shyam N Nargol AVF Wells SR Collier R Pabbruwe M Joyce TJ Langton DJ

Aims. The aim of this study was to investigate whether wear and backside deformation of polyethylene (PE) tibial inserts may influence the cement cover of tibial trays of explanted total knee arthroplasties (TKAs). Methods. At our retrieval centre, we measured changes in the wear and deformation of PE inserts using coordinate measuring machines and light microscopy. The amount of cement cover on the backside of tibial trays was quantified as a percentage of the total surface. The study involved data from the explanted fixed-bearing components of four widely used contemporary designs of TKA (Attune, NexGen, Press Fit Condylar (PFC), and Triathlon), revised for any indication, and we compared them with components that used previous generations of PE. Regression modelling was used to identify variables related to the amount of cement cover on the retrieved trays. Results. A total of 114 explanted fixed-bearing TKAs were examined. This included 76 used with contemporary PE inserts which were compared with 15 used with older generation PEs. The Attune and NexGen (central locking) trays were found to have significantly less cement cover than Triathlon and PFC trays (peripheral locking group) (p = 0.001). The median planicity values of the PE inserts used with central locking trays were significantly greater than of those with peripheral locking inserts (205 vs 85 microns; p < 0.001). Attune and NexGen inserts had a characteristic pattern of backside deformation, with the outer edges of the PE deviating inferiorly, leaving the PE margins as the primary areas of articulation. Conclusion. Explanted TKAs with central locking mechanisms were significantly more likely to debond from the cement mantle. The PE inserts of these designs showed characteristic patterns of deformation, which appeared to relate to the manufacturing process and may be exacerbated in vivo. This pattern of deformation was associated with PE wear occurring at the outer edges of the articulation, potentially increasing the frictional torque generated at this interface. Cite this article: Bone Joint J 2021;103-B(12):1791–1801


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 191 - 195
1 Jun 2021
Gausden EB Shirley MB Abdel MP Sierra RJ

Aims. To describe the risk of periprosthetic joint infection (PJI) and reoperation in patients who have an acute, traumatic wound dehiscence following total knee arthroplasty (TKA). Methods. From January 2002 to December 2018, 16,134 primary TKAs were performed at a single institution. A total of 26 patients (0.1%) had a traumatic wound dehiscence within the first 30 days. Mean age was 68 years (44 to 87), 38% (n = 10) were female, and mean BMI was 34 kg/m. 2. (23 to 48). Median time to dehiscence was 13 days (interquartile range (IQR) 4 to 15). The dehiscence resulted from a fall in 22 patients and sudden flexion after staple removal in four. The arthrotomy was also disrupted in 58% (n = 15), including a complete extensor mechanism disruption in four knees. An irrigation and debridement with component retention (IDCR) was performed within 48 hours in 19 of 26 knees and two-thirds were discharged on antibiotic therapy. The mean follow-up was six years (2 to 15). The association of wound dehiscence and the risk of developing a PJI was analyzed. Results. Patients who sustained a traumatic wound dehiscence had a 6.5-fold increase in the risk of PJI (95% confidence interval (CI) 1.6 to 26.2; p = 0.008). With the small number of PJIs, no variables were found to be significant risk factors. However, there were no PJIs in any of the patients who were treated with IDCR and a course of antibiotics. Three knees required reoperation including one two-stage exchange for PJI, one repeat IDCR for PJI, and one revision for aseptic loosening of the tibial component. Conclusion. Despite having a traumatic wound dehiscence, the risk of PJI was low, but much higher than experienced in all other TKAs during the same period. We recommend urgent IDCR and a course of postoperative antibiotics to decrease the risk of PJI. A traumatic wound dehiscence increases risk of PJI by 6.5-fold. Cite this article: Bone Joint J 2021;103-B(6 Supple A):191–195


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1103 - 1110
1 Jun 2021
Tetreault MW Hines JT Berry DJ Pagnano MW Trousdale RT Abdel MP

Aims. This study aimed to determine outcomes of isolated tibial insert exchange (ITIE) during revision total knee arthroplasty (TKA). Methods. From 1985 to 2016, 270 ITIEs were performed at one institution for instability (55%, n = 148), polyethylene wear (39%, n = 105), insert fracture/dissociation (5%, n = 14), or stiffness (1%, n = 3). Patients with component loosening, implant malposition, infection, and extensor mechanism problems were excluded. Results. Survivorship free of any re-revision was 68% at ten years. For the indication of insert wear, survivorship free of any re-revision at ten years was 74%. Re-revisions were more frequent for index diagnoses other than wear (hazard ratio (HR) 1.9; p = 0.013), with ten-year survivorships of 69% for instability and 37% for insert fracture/dissociation. Following ITIE for wear, the most common reason for re-revision was aseptic loosening (33%, n = 7). For other indications, the most common reason for re-revision was recurrence of the original diagnosis. Mean Knee Society Scores improved from 54 (0 to 94) preoperatively to 77 (38 to 94) at ten years. Conclusion. After ITIE, the risk and reasons for re-revision correlated with preoperative indications. The best results were for polyethylene wear. For other diagnoses, the re-revision rate was higher and the failure mode was most commonly recurrence of the original indication for the revision TKA. Cite this article: Bone Joint J 2021;103-B(6):1103–1110


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 468 - 474
1 May 2024
d'Amato M Flevas DA Salari P Bornes TD Brenneis M Boettner F Sculco PK Baldini A

Aims

Obtaining solid implant fixation is crucial in revision total knee arthroplasty (rTKA) to avoid aseptic loosening, a major reason for re-revision. This study aims to validate a novel grading system that quantifies implant fixation across three anatomical zones (epiphysis, metaphysis, diaphysis).

Methods

Based on pre-, intra-, and postoperative assessments, the novel grading system allocates a quantitative score (0, 0.5, or 1 point) for the quality of fixation achieved in each anatomical zone. The criteria used by the algorithm to assign the score include the bone quality, the size of the bone defect, and the type of fixation used. A consecutive cohort of 245 patients undergoing rTKA from 2012 to 2018 were evaluated using the current novel scoring system and followed prospectively. In addition, 100 first-time revision cases were assessed radiologically from the original cohort and graded by three observers to evaluate the intra- and inter-rater reliability of the novel radiological grading system.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 176 - 180
1 Jun 2020
Lee G Colen DL Levin LS Kovach SJ

Aims. The integrity of the soft tissue envelope is crucial for successful treatment of infected total knee arthroplasty (TKA). The purpose of this study was to evaluate the rate of limb salvage, infection control, and clinical function following microvascular free flap coverage for salvage of the infected TKA. Methods. We retrospectively reviewed 23 microvascular free tissue transfers for management of soft tissue defects in infected TKA. There were 16 men and seven women with a mean age of 61.2 years (39 to 81). The median number of procedures performed prior to soft tissue coverage was five (2 to 9) and all patients had failed at least one two-stage reimplantation procedure. Clinical outcomes were measured using the Knee Society Scoring system for pain and function. Results. In all, one patient was lost to follow-up prior to 12 months. The remaining 22 patients were followed for a mean of 46 months (12 to 92). At latest follow-up, four patients (18%) had undergone amputation for failure of treatment and persistent infection. For the other 18 patients, 11 patients (50%) had maintained a knee prosthesis in place while seven patients had undergone resections for persistent infection but retained their limbs (32%). Reoperations were common following coverage and reimplantation. The median number of additional procedures was two (0 to 6). Clinical function was poor in patients who underwent reimplantation and retained a knee prosthesis following free flap coverage with a mean KSS score for pain and function of 44 (0 to 70) and 30 (0 to 65), respectively. All patients required an assistive device. Extensor mechanism problems and extensor lag requiring bracing were common following limb salvage and prosthesis reimplantation. Conclusion. Microvascular tissue transfer for management of infected TKA can be successful in limb salvage (82%) but clinical outcomes in salvaged limbs were poor. Cite this article: Bone Joint J 2020;102-B(6 Supple A):176–180


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 622 - 634
1 Jun 2023
Simpson CJRW Wright E Ng N Yap NJ Ndou S Scott CEH Clement ND

Aims

This systematic review and meta-analysis aimed to compare the influence of patellar resurfacing following cruciate-retaining (CR) and posterior-stabilized (PS) total knee arthroplasty (TKA) on the incidence of anterior knee pain, knee-specific patient-reported outcome measures, complication rates, and reoperation rates.

Methods

A systematic review of MEDLINE, PubMed, and Google Scholar was performed to identify randomized controlled trials (RCTs) according to search criteria. Search terms used included: arthroplasty, replacement, knee (Mesh), TKA, prosthesis, patella, patellar resurfacing, and patellar retaining. RCTs that compared patellar resurfacing versus unresurfaced in primary TKA were included for further analysis. Studies were evaluated using the Scottish Intercollegiate Guidelines Network assessment tool for quality and minimization of bias. Data were synthesized and meta-analysis performed.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1279 - 1285
1 Dec 2023
Baker JF Nadar AC Jouflas AC Smith LS Sachdeva S Yakkanti MR Malkani AL

Aims

The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design.

Methods

This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m2 (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 610 - 621
1 Jun 2023
Prodromidis AD Chloros GD Thivaios GC Sutton PM Pandit H Giannoudis PV Charalambous CP

Aims

Loosening of components after total knee arthroplasty (TKA) can be associated with the development of radiolucent lines (RLLs). The aim of this study was to assess the rate of formation of RLLs in the cemented original design of the ATTUNE TKA and their relationship to loosening.

Methods

A systematic search was undertaken using the Cochrane methodology in three online databases: MEDLINE, Embase, and CINAHL. Studies were screened against predetermined criteria, and data were extracted. Available National Joint Registries in the Network of Orthopaedic Registries of Europe were also screened. A random effects model meta-analysis was undertaken.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1271 - 1278
1 Dec 2023
Rehman Y Korsvold AM Lerdal A Aamodt A

Aims

This study compared patient-reported outcomes of three total knee arthroplasty (TKA) designs from one manufacturer: one cruciate-retaining (CR) design, and two cruciate-sacrificing designs, anterior-stabilized (AS) and posterior-stabilized (PS).

Methods

Patients scheduled for primary TKA were included in a single-centre, prospective, three-armed, blinded randomized trial (n = 216; 72 per group). After intraoperative confirmation of posterior cruciate ligament (PCL) integrity, patients were randomly allocated to receive a CR, AS, or PS design from the same TKA system. Insertion of an AS or PS design required PCL resection. The primary outcome was the mean score of all five subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS) at two-year follow-up. Secondary outcomes included all KOOS subscales, Oxford Knee Score, EuroQol five-dimension health questionnaire, EuroQol visual analogue scale, range of motion (ROM), and willingness to undergo the operation again. Patient satisfaction was also assessed.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 170 - 175
1 Jun 2020
Chalmers BP Matrka AK Sems SA Abdel MP Sierra RJ Hanssen AD Pagnano MW Mabry TM Perry KI

Aims. Arthrodesis is rarely used as a salvage procedure for patients with a chronically infected total knee arthroplasty (TKA), and little information is available about the outcome. The aim of this study was to assess the reliability, durability, and safety of this procedure as the definitive treatment for complex, chronically infected TKA, in a current series of patients. Methods. We retrospectively identified 41 patients (41 TKAs) with a complex infected TKA, who were treated between 2002 and 2016 using a deliberate, two-stage knee arthrodesis. Their mean age was 64 years (34 to 88) and their mean body mass index (BMI) was 39 kg/m. 2. (25 to 79). The mean follow-up was four years (2 to 9). The extensor mechanism (EM) was deficient in 27 patients (66%) and flap cover was required in 14 (34%). Most patients were host grade B (56%) or C (29%), and limb grade 3 (71%), according to the classification of McPherson et al. A total of 12 patients (29%) had polymicrobial infections and 20 (49%) had multi-drug resistant organisms; fixation involved an intramedullary nail in 25 (61%), an external fixator in ten (24%), and dual plates in six (15%). Results. Survivorship free from amputation, persistent infection, and reoperation, other than removal of an external fixator, at five years was 95% (95% confidence interval (CI) 89% to 100%), 85% (95% CI 75% to 95%), and 64% (95% CI 46% to 82%), respectively. Reoperation, other than removal of an external fixator, occurred in 13 patients (32%). After the initial treatment, radiological nonunion developed in ten knees (24%). Nonunion was significantly correlated with persistent infection (p = 0.006) and external fixation (p = 0.005). Of those patients who achieved limb salvage, 34 (87%) remained mobile and 31 (79%) had ‘absent’ or ‘minimal’ pain ratings. Conclusion. Knee arthrodesis using a two-stage protocol achieved a survivorship free from amputation for persistent infection of 95% at five years with 87% of patients were mobile at final follow-up. However, early reoperation was common (32%). This is not surprising as this series included worst-case infected TKAs in which two-thirds of the patients had a disrupted EM, one-third required flap cover, and most had polymicrobial or multi-drug resistant organisms. Cite this article: Bone Joint J 2020;102-B(6 Supple A):170–175