We present the electromyographic (EMG) results
ten years after open decompression of the median nerve at the wrist
and compare them with the clinical and functional outcomes as judged
by Levine’s Questionnaire. This retrospective study evaluated 115
patients who had undergone carpal tunnel decompression at a mean
of 10.47 years (9.24 to 11.36) previously. A positive EMG diagnosis
was found in 77 patients (67%), including those who were asymptomatic
at ten years. It is necessary to include both clinical and functional results
as well as electromyographic testing in the
The purpose of this study was to assess the clinical
and radiological outcomes of dorsal intercarpal ligament capsulodesis
for the treatment of static scapholunate instability at a minimum
follow-up of four years. A total of 59 patients who underwent capsulodesis
for this condition were included in a retrospective analysis after
a mean of 8.25 years (4.3 to 12). A total of eight patients underwent
a salvage procedure at a mean of 2.33 years (0.67 to 7.6) and were
excluded. The mean range of extension/flexion was 88° (15° to 135°)
and of ulnar/radial deviation was 38° (0° to 75°) at final follow-up.
The mean Disabilities of the Arm Shoulder and Hand (DASH) score
and Mayo wrist scores were 28 (0 to 85) and 61 (0 to 90), respectively. After
significant improvement immediately post-operatively (p <
0.001
and p = 0.001, respectively), the mean scapholunate and radiolunate
angles deteriorated to 70° (40° to 90°) and 8° (-15° to 25°), respectively,
at final follow-up, which were not significantly different from
their pre-operative values (p = 0.6 and p = 0.4, respectively).
The mean carpal height index decreased significantly from 1.53 (1.38
to 1.65) to 1.48 (1.29 to 1.65) indicating progressive carpal collapse
(p <
0.001); 40 patients (78%) had radiological evidence of degenerative
arthritis. Capsulodesis did not maintain carpal reduction over time. Although
the consequent ongoing scapholunate instability resulted in early
arthritic degeneration, most patients had acceptable
Between 1978 and 1986, 59 patients received a GSB III elbow prosthesis, six of them in both elbows. Rheumatoid arthritis (RA) was the underlying cause in 51 of the patients and post-traumatic osteoarthritis (PTOA) in eight. Of these, 24 patients (28 prostheses) have since died; two, both operated on bilaterally, had had their implants for more than ten years and had already been assessed for inclusion in the
We report the
Between 1982 and 1997, 403 consecutive patients (522 elbows) with rheumatoid arthritis underwent Souter-Strathclyde total elbow replacement. By the end of 2007, there had been 66 revisions for aseptic loosening in 60 patients. The mean time of follow-up was 10.6 years (0 to 25) The survival rates at five-, ten, 15 and 19 years were 96% (95%, confidence interval (CI) 95 to 98), 89% (95% CI 86 to 92), 83% (95% CI 78 to 87), and 77% (95% CI 69 to 85), respectively. The small and medium-sized short-stemmed primary humeral components had a 5.6-fold and 3.6-fold risk of revision for aseptic loosening respectively, compared to the medium-sized long-stemmed component. The small and medium-sized all-polyethylene ulnar components had respectively a 28.2-fold and 8.4-fold risk of revision for aseptic loosening, compared to the metal-backed ulnar components. The use of retentive ulnar components was not associated with an increased risk of aseptic loosening compared to non-retentive implants.
We reviewed the outcome of arthroscopic stabilisation of anterior glenohumeral instability in young adults using the transglenoid suture technique. A questionnaire was sent to 455 consecutive patients who had undergone this procedure between 1992 and 2000. Of these, 312 patients (68.5%) with 313 affected shoulders and a mean age of 20 years (18 to 28) responded. Outcome was determined by the number of re-dislocations or, in patients who had not re-dislocated, by the disease-specific quality of life as measured by the Western Ontario Shoulder Instability index. During a mean follow-up of 6.4 years (1 to 14), 177 patients (56%) sustained a re-dislocation, including 70 who required a further operation. In 136 patients (44%) who reported neither re-dislocation nor re-operation, the index scores were good (median 90.4%; 28.9% to 100%). No significant peri- or pre-operative predictors of re-dislocation or re-operation were found. We found a high rate of re-dislocation after transglenoid suture repair in young, physically active patients.
We performed a prospective study in 186 patients with a minimum follow-up of two years in order to attempt to predict successful major re-implantation of the upper limb. There were 137 men and 49 women with 24 amputations of the palm, 75 of the wrist, 50 of the forearm, 9 disarticulations through the elbow, and 28 amputations through the upper arm. The degree of injury to the amputated segment and the stump were good predictors of the rate of success and the final outcome. Adequate preservation, contraction of the muscle in the amputated part after stimulation, the level of injury and a smoking habit were fair indicators, but the serum potassium concentration in the amputated segment was the best objective predictor. When it is higher than 6.5 mmol/l 30 minutes after re-perfusion, re-implantation should be avoided. A high systemic venous serum potassium concentration was also found before clinical signs of the re-perfusion syndrome were seen.
We present the
The purpose of this study was to assess the
Spinal accessory nerve palsy leads to painful disability of the shoulder, carrying an uncertain prognosis. We reviewed the
Restoration of hand function is rarely achieved after a complete closed traction lesion of the supraclavicular brachial plexus. We describe the injury, treatment, rehabilitation and
Between September 1993 and September 1996, we performed 34 Kudo 5 total elbow replacements in 31 rheumatoid patients. All 22 surviving patients were reviewed at a mean of 11.9 years (10 to 14). Their mean age was 56 years (37 to 78) at the time of operation. All had Larsen grade IV or V rheumatoid changes on X-ray. Nine (three bilateral replacements and six unilateral) had died from unrelated causes. One who had died before ten years underwent revision for dislocation. Of the 22 total elbow replacements reviewed six had required revision, four for aseptic loosening (one humeral and three ulnar) and two for infection. Post-operatively, one patient had neuropraxia of the ulnar nerve and one of the radial nerve. Two patients had valgus tilting of the ulnar component. With revision as the endpoint, the mean survival time for the prosthesis was 11.3 years (95% confidence interval (10 to 13) and the estimated survival of the prosthesis at 12 years according to Kaplan-Meier survival analysis was 74% (95% confidence interval 0.53 to 0.91). Of the 16 surviving implants, ten were free from pain, four had mild pain and two moderate. The mean arc of flexion/extension of the elbow was 106° (65° to 130°) with pronation/supination of 90° (30° to 150°) with the joint at 90° of flexion. The mean Mayo elbow performance score was 82 (60 to 100) with five excellent, ten good and one fair result. Good
We report the outcome of a modified Bankart procedure using suture anchors in 31 patients (31 shoulders) with a mean follow-up of 11 years (10 to 15). The mean age of the patients was 28 years (16 to 39). At follow-up, the mean Rowe score was 90 points (66 to 98) and the Constant score was 96 points (85 to 100). A total of 26 shoulders (84%) had a good or excellent result. The rate of recurrence varied between 6.7% and 9.7% and depended on how recurrence was defined. Two patients had a significant new injury at one and nine years, respectively after operation. The overall rate of instability (including subluxations) varied between 12.9% and 22.6%. All patients returned to work, with 29 (94%) resuming their pre-operative occupation and level of activity. Mild radiological osteoarthritis was seen in nine shoulders (29%) and severe osteoarthritis in one. We conclude that the open modified Bankart procedure is a reliable surgical technique with good
There are no
We assessed the
We compared the
We classified fractures of the base of the middle phalanx into five types: 1) single palmar fragment; 2) single dorsal fragment; 3) two main fragments; 4) not involving the articular surface, including epiphyseal separation in children; and 5) all others. Types 1 and 2 were subclassified into avulsion, split and split-depression. Surgery is recommended for unstable type-1 avulsion fractures, type-2 avulsions which may develop buttonhole deformities, and all fractures which displace articular cartilage surfaces.
We compared the
We analysed the results of arthroscopic synovectomy of the wrist in 18 patients (19 wrists) with rheumatoid arthritis who had not responded to conservative treatment. The patients’ symptoms were assessed using visual analogue scales for pain and satisfaction. Standard posteroanterior radiographs which were taken pre-operatively and at final follow-up were analysed using a modified Larsen scoring system (normal, 0; total destruction, 40). The mean follow-up period was 29.2 months (24 to 45). The mean pre-operative pain score was 8.58 which decreased to 3.58 one year after surgery and increased again to 4.42 at final follow-up. This suggested a gradual increase in pain with time. The mean satisfaction score was 6.26. The mean modified Larsen’s score was 9.8 pre-operatively and 13.9 at final follow-up, which demonstrated the slow progression of degenerative changes. Arthroscopic synovectomy for rheumatoid arthritis of the wrist allows effective pain relief and high patient satisfaction, although any prolonged benefits will require
We analysed the