Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
The Bone & Joint Journal
Dates
Year From

Year To
The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 959 - 965
1 Nov 1990
Kavanagh T Cannon Pringle J Stoker D Kemp H

We have reviewed 20 cases of parosteal osteosarcoma treated by wide local resection and prosthetic replacement and followed up for six to 17 years. Limb function was excellent in 85%. One patient with grade III histological disease developed pulmonary metastases. Four patients had local recurrences, which were related to repeated preliminary biopsies, inappropriate siting of biopsy and vascular encroachment by the tumour. After this mode of treatment, the outcome was not related to medullary invasion by the tumour.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 3 | Pages 349 - 354
1 May 1984
Lettin A Kavanagh T Scales J

Between 1969 and 1971 20 prototypes of the Stanmore total knee prosthesis were used to replace severely arthritic knees in 18 patients. Seven patients died before the final follow-up and one had to have her leg amputated because of deep infection; in none of these patients had the prosthesis become loose. Ten patients (11 knees) were reviewed at least 10 years after operation. There was no significant clinical deterioration in 7 of these 11 surviving knees when the results at one year were compared with those at 10 years.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 3 | Pages 355 - 361
1 May 1984
Lettin A Kavanagh T Craig D Scales J

We review 210 Stanmore knee replacements in 163 patients to assess the survival of the prostheses and the long-term results. The annual rate of failure reached a maximum of 4.6% in the fourth year after operation; thereafter it declined to reach zero by the eighth year. Between two and eight years after operation, 66.3% of the surviving knees were completely free of pain and 30.2% had mild retropatellar pain. Fixed flexion deformities present before operation were completely corrected in 73% of the knees, and varus or valgus deformities were invariably corrected. Stability was always restored to unstable knees and 80.8% of knees flexed to 90 degrees or more after replacement. Aseptic loosening (8.1%), prosthetic infection (4.3%) and femoral fracture (2.9%) led to 8.5% of the prostheses being revised or removed over eight years. Modifications in prosthetic design and operative techniques have been introduced to minimise such complications in the future.