Abstract
We review 210 Stanmore knee replacements in 163 patients to assess the survival of the prostheses and the long-term results. The annual rate of failure reached a maximum of 4.6% in the fourth year after operation; thereafter it declined to reach zero by the eighth year. Between two and eight years after operation, 66.3% of the surviving knees were completely free of pain and 30.2% had mild retropatellar pain. Fixed flexion deformities present before operation were completely corrected in 73% of the knees, and varus or valgus deformities were invariably corrected. Stability was always restored to unstable knees and 80.8% of knees flexed to 90 degrees or more after replacement. Aseptic loosening (8.1%), prosthetic infection (4.3%) and femoral fracture (2.9%) led to 8.5% of the prostheses being revised or removed over eight years. Modifications in prosthetic design and operative techniques have been introduced to minimise such complications in the future.