Advertisement for orthosearch.org.uk
Results 1 - 50 of 92
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 3 | Pages 503 - 519
1 Aug 1962
Little K Kelly M Courts A

1. The appearance of decalcified bone matrix in the electron microscope is described. 2. In the matrix two types of collagen fibril have been distinguished. Differences observed are in solubility, x-ray diffraction pattern and appearance. In infant bone the form which appears as fine fibrils predominates. In adult bone the form which appears as tubular fibrils of larger diameter predominates. 3. In bones from elderly subjects the chemical reaction employed to convert collagen into eucollagen sometimes hydrolyses fatty acid esters, and lines due to the free fatty acid are found on the x-ray diffraction patterns of the insoluble residue after citrate extraction. 4. In ancient bones and fossils the stable tubular form of collagen survives, but not the fine fibrils. 5. When decalcified, the matrix in osteoporotic bones loses its architecture and fibrillar form. Under conditions in which only a small fraction is dissolved from normal bone most of the collagen in osteoporotic bone disperses in citric acid. The insoluble residue then gives a modified x-ray diffraction pattern. 6. Evidence has been produced to suggest that the immediate cause of many forms of osteoporosis is some local factor affecting the osteocytes, rather than a general chemical effect


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 506 - 508
1 May 1991
Ryan M

Intramedullary rods manufactured from polyacetal were used to fix diaphyseal fractures in osteoporotic bone. They are pliable and can be introduced without further damage to such bone. Their low elastic modulus induces abundant callus. They can be locked with cortical bone screws without the need of jigs or radiographic control. Nine femoral and five tibial fractures were fixed in 10 patients, all with osteoporosis; 13 united primarily; one required bone grafting. No implant broke; however, no ambulant patient weighed more than 75 kg. The rods offer a promising treatment for diaphyseal fractures in osteoporotic bone


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 701 - 705
1 May 2007
Thiele OC Eckhardt C Linke B Schneider E Lill CA

We investigated several factors which affect the stability of cortical screws in osteoporotic bone using 18 femora from cadavers of women aged between 45 and 96 years (mean 76). We performed bone densitometry to measure the bone mineral density of the cortical and cancellous bone of the shaft and head of the femur, respectively. The thickness and overall bone mass of the cortical layer of the shaft of the femur were measured using a microCT scanner. The force required to pull-out a 3.5 mm titanium cortical bone screw was determined after standardised insertion into specimens of the cortex of the femoral shaft. A significant correlation was found between the pull-out strength and the overall bone mass of the cortical layer (r. 2. = 0.867, p < 0.01) and also between its thickness (r. 2. = 0.826, p < 0.01) and bone mineral density (r. 2. = 0.861, p < 0.01). There was no statistically significant correlation between the age of the donor and the pull-out force (p = 0.246), the cortical thickness (p = 0.199), the bone mineral density (p = 0.697) or the level of osteoporosis (p = 0.378). We conclude that the overall bone mass, the thickness and the bone mineral density of the cortical layer, are the main factors which affect the stability of a screw in human female osteoporotic cortical bone


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 139 - 143
1 Jan 2001
Fini M Giavaresi G Torricelli P Krajewski A Ravaglioli A Belmonte MM Biagini G Giardino R

We implanted nails made of titanium (Ti6Al4V) and of two types of glass ceramic material (RKKP and AP40) into healthy and osteopenic rats. After two months, a histomorphometric analysis was performed and the affinity index calculated. In addition, osteoblasts from normal and osteopenic bone were cultured and the biomaterials were evaluated in vitro.

In normal bone the rate of osseointegration was similar for all materials tested (p > 0.5) while in osteopenic bone AP40 did not osseointegrate (p > 0.0005).

In vitro, no differences were observed for all biomaterials when cultured in normal bone-derived cells whereas in osteopenic-bone-derived cells there was a significant difference in some of the tested parameters when using AP40.

Our findings suggest that osteopenic models may be used in vivo in the preclinical evaluation of orthopaedic biomaterials. We suggest that primary cell cultures from pathological models could be used as an experimental model in vitro.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 151 - 152
1 Jan 2002
Harper WM


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 112 - 123
1 Feb 2023
Duckworth AD Carter TH Chen MJ Gardner MJ Watts AC

Despite being one of the most common injuries around the elbow, the optimal treatment of olecranon fractures is far from established and stimulates debate among both general orthopaedic trauma surgeons and upper limb specialists. It is almost universally accepted that stable non-displaced fractures can be safely treated nonoperatively with minimal specialist input. Internal fixation is recommended for the vast majority of displaced fractures, with a range of techniques and implants to choose from. However, there is concern regarding the complication rates, largely related to symptomatic metalwork resulting in high rates of implant removal. As the number of elderly patients sustaining these injuries increases, we are becoming more aware of the issues associated with fixation in osteoporotic bone and the often fragile soft-tissue envelope in this group. Given this, there is evidence to support an increasing role for nonoperative management in this high-risk demographic group, even in those presenting with displaced and/or multifragmentary fracture patterns. This review summarizes the available literature to date, focusing predominantly on the management techniques and available implants for stable fractures of the olecranon. It also offers some insights into the potential avenues for future research, in the hope of addressing some of the pertinent questions that remain unanswered. Cite this article: Bone Joint J 2023;105-B(2):112–123


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1132 - 1138
1 Aug 2015
Aitken SA Jenkins PJ Rymaszewski L

The best method of managing a fracture of the distal humerus in a frail low-demand patient with osteoporotic bone remains controversial. Total elbow arthroplasty (TEA) has been recommended for patients in whom open reduction and internal fixation (ORIF) is not possible. Conservative methods of treatment, including the ‘bag of bones’ technique (acceptance of displacement of the bony fragments and early mobilisation), are now rarely considered as they are believed to give a poor functional result. We reviewed 40 elderly and low-demand patients (aged 50 to 93 years, 72% women) with a fracture of the distal humerus who had been treated conservatively at our hospital between March 2008 and December 2013, and assessed their short- and medium-term functional outcome. . In the short-term, the mean Broberg and Morrey score improved from 42 points (poor; 23 to 80) at six weeks after injury to 67 points (fair; 40 to 88) by three months. . In the medium-term, surviving patients (n = 20) had a mean Oxford elbow score of 30 points (7 to 48) at four years and a mean Disabilities of the Arm, Shoulder and Hand score of 38 points (0 to 75): 95% reported a functional range of elbow flexion. The cumulative rate of fracture union at one year was 53%. The mortality at five years approached 40%. . Conservative management of a fracture of the distal humerus in a low-demand patient only gives a modest functional result, but avoids the substantial surgical risks associated with primary ORIF or TEA. Cite this article: Bone Joint J 2015;97-B:1132–8


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 233 - 238
1 May 1981
Dickenson R Hutton W Stott

Specimens of femoral cortical bone from normal subjects and from patients with osteoporosis were mechanically tested in tension to destruction. The osteoporotic bone showed less strength and less stiffness than the normal bone; these reductions are related to the increased cavity area in osteoporosis. Further, the osteoporotic bone is not able to absorb as much energy before fracture as the normal bone; but this difference is not related to changes in cavity area


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1100 - 1110
1 Oct 2024
Arenas-Miquelez A Barco R Cabo Cabo FJ Hachem A

Bone defects are frequently observed in anterior shoulder instability. Over the last decade, knowledge of the association of bone loss with increased failure rates of soft-tissue repair has shifted the surgical management of chronic shoulder instability. On the glenoid side, there is no controversy about the critical glenoid bone loss being 20%. However, poor outcomes have been described even with a subcritical glenoid bone defect as low as 13.5%. On the humeral side, the Hill-Sachs lesion should be evaluated concomitantly with the glenoid defect as the two sides of the same bipolar lesion which interact in the instability process, as described by the glenoid track concept. We advocate adding remplissage to every Bankart repair in patients with a Hill-Sachs lesion, regardless of the glenoid bone loss. When critical or subcritical glenoid bone loss occurs in active patients (> 15%) or bipolar off-track lesions, we should consider anterior glenoid bone reconstructions. The techniques have evolved significantly over the last two decades, moving from open procedures to arthroscopic, and from screw fixation to metal-free fixation. The new arthroscopic techniques of glenoid bone reconstruction procedures allow precise positioning of the graft, identification, and treatment of concomitant injuries with low morbidity and faster recovery. Given the problems associated with bone resorption and metal hardware protrusion, the new metal-free techniques for Latarjet or free bone block procedures seem a good solution to avoid these complications, although no long-term data are yet available.

Cite this article: Bone Joint J 2024;106-B(10):1100–1110.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 646 - 655
1 Jul 2024
Longo UG Gulotta LV De Salvatore S Lalli A Bandini B Giannarelli D Denaro V

Aims

Proximal humeral fractures are the third most common fracture among the elderly. Complications associated with fixation include screw perforation, varus collapse, and avascular necrosis of the humeral head. To address these challenges, various augmentation techniques to increase medial column support have been developed. There are currently no recent studies that definitively establish the superiority of augmented fixation over non-augmented implants in the surgical treatment of proximal humeral fractures. The aim of this systematic review and meta-analysis was to compare the outcomes of patients who underwent locking-plate fixation with cement augmentation or bone-graft augmentation versus those who underwent locking-plate fixation without augmentation for proximal humeral fractures.

Methods

The search was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Articles involving patients with complex proximal humeral fractures treated using open reduction with locking-plate fixation, with or without augmentation, were considered. A meta-analysis of comparative studies comparing locking-plate fixation with cement augmentation or with bone-graft augmentation versus locking-plate fixation without augmentation was performed.


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 2 | Pages 246 - 261
1 May 1973
Solomon L

1. It is well known that the administration of corticosteroids may result in necrosis and progressive destruction of the femoral head. Identical changes have been found in chronic alcoholics, in South African negroes suffering from iron-overload osteoporosis and in patients with arthritis of the hip treated with non-steroid anti-inflammatory and analgesic preparations. The term "drug-induced arthropathy" is used to describe the common pathological lesion. 2. Seventy-two patients with this complication have been investigated and forty-two femoral heads were available for detailed study. The characteristic change is subchondral fragmentation and osteonecrosis, followed later by reactive bone formation and the typical increased radiographic density. 3. The frequent occurrence of fat occupying the Haversian canals in the affected femoral heads has not been adequately explained and its relationship to the destructive arthropathy remains obscure. The findings presented here do not support the theory that fat emboli are responsible for the subchondral bone changes. 4. More credence is given to the theory of subchondral microfracture in osteoporotic bone. The destructive arthropathy invariably follows the administration of some anti-inflammatory or analgesic preparation. It is postulated that a state of diminished sensibility predisposes to microtrauma in osteoporotic bone resulting in subarticular collapse of the femoral head


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1602 - 1607
1 Dec 2008
Bogner R Hübner C Matis N Auffarth A Lederer S Resch H

The surgical treatment of three- and four-part fractures of the proximal humerus in osteoporotic bone is difficult and there is no consensus as to which technique leads to the best outcome in elderly patients. Between 1998 and 2004 we treated 76 patients aged over 70 years with three- or four-part fractures by percutaneous reduction and internal fixation using the Humerusblock. A displacement of the tuberosity of > 5 mm and an angulation of > 30° of the head fragment were the indications for surgery. Of the patients 50 (51 fractures) were available for follow-up after a mean of 33.8 months (5.8 to 81). The absolute, age-related and side-related Constant scores were recorded. Of the 51 fractures, 46 (90.2%) healed primarily. Re-displacement of fragments or migration of Kirschner wires was seen in five cases. Necrosis of the humeral head developed in four patients. In three patients a secondary arthroplasty had to be performed, in two because of re-displacement and in one for necrosis of the head. There was one case of deep infection which required a further operation and one of delayed healing. The mean Constant score of the patients with a three-part fracture was 61.2 points (35 to 87) which was 84.9% of the score for the non-injured arm. In four-part fractures it was 49.5 points (18 to 87) or 68.5% of the score for the non-injured arm. The Humerusblock technique can provide a comfortable and mobile shoulder in elderly patients and is a satisfactory alternative to replacement and traditional techniques of internal fixation


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 121 - 129
1 Mar 2024
Orce Rodríguez A Smith PN Johnson P O'Sullivan M Holder C Shimmin A

Aims

In recent years, the use of a collared cementless femoral prosthesis has risen in popularity. The design intention of collared components is to transfer some load to the resected femoral calcar and prevent implant subsidence within the cancellous bone of the metaphysis. Conversely, the load transfer for a cemented femoral prosthesis depends on the cement-component and cement-bone interface interaction. The aim of our study was to compare the three most commonly used collared cementless components and the three most commonly used tapered polished cemented components in patients aged ≥ 75 years who have undergone a primary total hip arthroplasty (THA) for osteoarthritis (OA).

Methods

Data from the Australian Orthopaedic Association National Joint Replacement Registry from 1 September 1999 to 31 December 2022 were analyzed. Collared cementless femoral components and cemented components were identified, and the three most commonly used components in each group were analyzed. We identified a total of 11,278 collared cementless components and 47,835 cemented components. Hazard ratios (HRs) from Cox proportional hazards models, adjusting for age and sex, were obtained to compare the revision rates between the groups.


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 28 - 37
1 Jan 2024
Gupta S Sadczuk D Riddoch FI Oliver WM Davidson E White TO Keating JF Scott CEH

Aims

This study aims to determine the rate of and risk factors for total knee arthroplasty (TKA) after operative management of tibial plateau fractures (TPFs) in older adults.

Methods

This is a retrospective cohort study of 182 displaced TPFs in 180 patients aged ≥ 60 years, over a 12-year period with a minimum follow-up of one year. The mean age was 70.7 years (SD 7.7; 60 to 89), and 139/180 patients (77.2%) were female. Radiological assessment consisted of fracture classification; pre-existing knee osteoarthritis (OA); reduction quality; loss of reduction; and post-traumatic OA. Fracture depression was measured on CT, and the volume of defect estimated as half an oblate spheroid. Operative management, complications, reoperations, and mortality were recorded.


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 50 - 59
1 Jan 2017
Carli AV Negus JJ Haddad FS

Aims. Periprosthetic femoral fractures (PFF) following total hip arthroplasty (THA) are devastating complications that are associated with functional limitations and increased overall mortality. Although cementless implants have been associated with an increased risk of PFF, the precise contribution of implant geometry and design on the risk of both intra-operative and post-operative PFF remains poorly investigated. A systematic review was performed to aggregate all of the PFF literature with specific attention to the femoral implant used. Patients and Methods. A systematic search strategy of several journal databases and recent proceedings from the American Academy of Orthopaedic Surgeons was performed. Clinical articles were included for analysis if sufficient implant description was provided. All articles were reviewed by two reviewers. A review of fundamental investigations of implant load-to-failure was performed, with the intent of identifying similar conclusions from the clinical and fundamental literature. Results. In total 596 articles were initially identified, with 34 being eligible for analysis. Aggregate analysis of 1691 PFFs in 342 719 primary THAs revealed a significantly higher number of PFFs with cementless femoral implants (p < 0.001). Single-wedge and double-wedge (fit-and-fill) femoral implants were associated with a threefold increase in PFF rates (p < 0.001) compared with anatomical, fully coated and tapered/rounded stems. Within cemented stems, loaded-taper (Exeter) stems were associated with more PFFs than composite-beam (Charnley) stems (p = 0.004). Review of the fundamental literature revealed very few studies comparing cementless component designs. Conclusion. Very few studies within the PFF literature provide detailed implant information. Cementless implants, specifically those of single-wedge and double-wedge, have the highest PFF rates in the literature, with most investigations recommending against their use in older patients with osteoporotic bone. This review illustrates the need for registries and future PFF studies to record implant name and information for future analysis. Furthermore, future biomechanical investigations comparing modern implants are needed to clarify the precise contribution of implant design to PFF risk. Cite this article: Bone Joint J 2017;99-B(1 Supple A):50–9


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 894 - 901
1 Jul 2022
Aebischer AS Hau R de Steiger RN Holder C Wall CJ

Aims

The aim of this study was to investigate the rate of revision for distal femoral arthroplasty (DFA) performed as a primary procedure for native knee fractures using data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR).

Methods

Data from the AOANJRR were obtained for DFA performed as primary procedures for native knee fractures from 1 September 1999 to 31 December 2020. Pathological fractures and revision for failed internal fixation were excluded. The five prostheses identified were the Global Modular Arthroplasty System, the Modular Arthroplasty System, the Modular Universal Tumour And Revision System, the Orthopaedic Salvage System, and the Segmental System. Patient demographic data (age, sex, and American Society of Anesthesiologists grade) were obtained, where available. Kaplan-Meier estimates of survival were used to determine the rate of revision, and the reasons for revision and mortality data were examined.


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 559 - 566
1 May 2022
Burden EG Batten T Smith C Evans JP

Aims

Arthroplasty is being increasingly used for the management of distal humeral fractures (DHFs) in elderly patients. Arthroplasty options include total elbow arthroplasty (TEA) and hemiarthroplasty (HA); both have unique complications and there is not yet a consensus on which implant is superior. This systematic review asked: in patients aged over 65 years with unreconstructable DHFs, what differences are there in outcomes, as measured by patient-reported outcome measures (PROMs), range of motion (ROM), and complications, between distal humeral HA and TEA?

Methods

A systematic review of the literature was performed via a search of MEDLINE and Embase. Two reviewers extracted data on PROMs, ROM, and complications. PROMs and ROM results were reported descriptively and a meta-analysis of complications was conducted. Quality of methodology was assessed using Wylde’s non-summative four-point system. The study was registered with PROSPERO (CRD42021228329).


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 76 - 82
1 Jan 2022
ten Brinke B Hesseling B Eygendaal D Hoelen MA Mathijssen NMC

Aims

Stemless humeral implants have been developed to overcome stem-related complications in total shoulder arthroplasty (TSA). However, stemless implant designs may hypothetically result in less stable initial fixation, potentially affecting long-term survival. The aim of this study is to investigate early fixation and migration patterns of the stemless humeral component of the Simpliciti Shoulder System and to evaluate clinical outcomes.

Methods

In this prospective cohort study, radiostereometric analysis (RSA) radiographs were obtained in 24 patients at one day, six weeks, six months, one year, and two years postoperatively. Migration was calculated using model-based RSA. Clinical outcomes were evaluated using the visual analogue scale (VAS), the Oxford Shoulder Score (OSS), the Constant-Murley Score (CMS), and the Disabilities of the Arm, Shoulder and Hand (DASH) score.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 774 - 776
1 Nov 1989
Spencer R

Retrospective review of 25 patients over 65 years of age with unilateral acetabular fractures managed conservatively showed that seven of the 23 survivors (30%) had an unacceptable functional result. Poor results were associated with: displaced posterior column fractures, osteoporosis, femoral head fracture, delayed diagnosis, inadequate radiographs, inappropriate or too brief traction, and early weight-bearing. In this age group acetabular fractures tend to be low-velocity injuries of osteoporotic bone and are not comparable with those in younger patients


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 733 - 735
1 Sep 1995
Fraser R Dickens D Cole W

We report the results of medial physeal stapling in 16 knees with primary genu valgum and 27 with secondary genu valgum. In the primary group, stapling was undertaken at a mean chronological age of 12 years in girls and 13 years in boys. The medial femoral physis was stapled in ten knees and the medial femoral and tibial physes in six knees. At skeletal maturity, all patients had excellent or good leg alignment. Secondary genu valgum is due to skeletal dysplasia, haematological or endocrine disorders, or to juvenile chronic arthritis. Stapling was at a mean chronological age of 11 years in girls and 14 years in boys. The medial femoral physis was stapled in 13 knees, the medial tibial physis in three and both in 11 knees. At skeletal maturity, 85% had excellent or good leg alignment, and correction had occurred within one year. Two of the poor results were due to staple extrusion from osteoporotic bone, and two to overcorrection. Rebound growth was minimal and unpredictable after the removal of staples. Medial physeal stapling is a suitable method of treatment for both primary and secondary genu valgum in late childhood and in adolescence. At least one year of knee growth is required to achieve correction, and care is needed to avoid overcorrection of the secondary genu valgum


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 71 - 78
1 Jan 2021
Maggs JL Swanton E Whitehouse SL Howell JR Timperley AJ Hubble MJW Wilson MJ

Aims

Periprosthetic fractures (PPFs) around cemented taper-slip femoral prostheses often result in a femoral component that is loose at the prosthesis-cement interface, but where the cement-bone interface remains well-fixed and bone stock is good. We aim to understand how best to classify and manage these fractures by using a modification of the Vancouver classification.

Methods

We reviewed 87 PPFs. Each was a first episode of fracture around a cemented femoral component, where surgical management consisted of revision surgery. Data regarding initial injury, intraoperative findings, and management were prospectively collected. Patient records and serial radiographs were reviewed to determine fracture classification, whether the bone cement was well fixed (B2W) or loose (B2L), and time to fracture union following treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 3 | Pages 464 - 484
1 Aug 1962
Urist MR Zaccalini PS MacDonald NS Skoog WA

1. Individuals who are normal and not osteoporotic seem to show retention of cortical bone at successive decades of life in proportion to the total lean body-mass. In patients with osteoporosis the weight of the skeleton decreases at a rate exceeding the physiological rate of atrophy of muscle, tendon and bone tissue that occurs with the time-dependent process of ageing. 2. Six patients representing the typical forms of osteoporosis commonly found in orthopaedic practice were investigated intensively over a period of three years and compared with individuals in whom there was no osteoporosis by studies of metabolic balance, Sr85 osteograms, and tetracycline deposition. 3. Studies of metabolic balance in patients with osteoporosis showed normal or negative calcium balances, but an equilibrium for the metabolism of nitrogen and phosphorus. Increased intake of calcium in the diet produced retention of calcium but not sufficient phosphorus, nitrogen or gain in weight to prove that the patient had made new bone and healed the osteoporosis. 4. Radio-isotope osteograms showed high, normal or low rates of change of uptake of Sr85 and the accretion rate was calculated to be normal or low in individuals with osteoporosis. High uptake of tetracycline by a small mass of bone tissue and by a relatively small percentage of the total number of osteons suggested that in an adult human being the calcium reserve in the skeleton is enormous. Thirty to 50 per cent of the total bone mass was sufficient to turn over 0·5 to 1·0 gramme, the amount of calcium utilised in twenty-four hours by the human adult. This was accomplished by structural or old bone throughout the entire skeleton, and by labile or newer bone located in approximately 10 per cent of the total number of Haversian cylinders or osteons. 5. Some of the unclosed or half-closed osteons were hyperactive in osteoporotic bones. In the process of remodelling of cortical bone a significant quantity of bone tissue was incompletely restored and there were, presumably as a result, intermittently large or small negative calcium balances. Osteoporosis may have been the cause, rather than the result, of the negative calcium balance. 6. The experimental and clinical literature of the past ten years, and studies on patients described in this critical review, were interpreted to indicate that prolonged calcium deficiency, castration, hyperadrenal corticoidism or a sedentary life may precipitate, accentuate and accelerate osteoporosis in individuals who are genetically predisposed to develop it. Sometimes high calcium intake or sex hormones, or both, may have slowed the rate of resorption but did not replace the deficit in cortical bone. 7. Further research is necessary to find the chief etiological factor and to produce the cure for this increasingly common disorder of the skeleton


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1629 - 1635
1 Dec 2020
Wang Q Sheng N Rui B Chen Y

Aims

The aim of this study was to explore why some calcar screws are malpositioned when a proximal humeral fracture is treated by internal fixation with a locking plate, and to identify risk factors for this phenomenon. Some suggestions can be made of ways to avoid this error.

Methods

We retrospectively identified all proximal humeral fractures treated in our institution between October 2016 and October 2018 using the hospital information system. The patients’ medical and radiological data were collected, and we divided potential risk factors into two groups: preoperative factors and intraoperative factors. Preoperative factors included age, sex, height, weight, body mass index, proximal humeral bone mineral density, type of fracture, the condition of the medial hinge, and medial metaphyseal head extension. Intraoperative factors included the grade of surgeon, neck-shaft angle after reduction, humeral head height, restoration of medial support, and quality of reduction. Adjusted binary logistic regression and multivariate logistic regression models were used to identify pre- and intraoperative risk factors. Area under the curve (AUC) analysis was used to evaluate the discriminative ability of the multivariable model.


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 2 | Pages 346 - 361
1 May 1961
Caldwell RA Collins DH

1. Radiological, chemical and histological examinations have been made of the lumbar vertebral bodies in 100 necropsies on patients dying in a general hospital, with a view to determining the range of variation of calcium content and radiographic density in normal and osteoporotic bone. 2. Radiographs were made of sagittal mid-line vertebral body slabs uniformly one centimetre in thickness, and the radiographic density of these specimens was measured in relation to an aluminium step-wedge of one to ten units. Radio-opacity of different vertebrae ranged from four to ten units. The specimen radiographs also clearly revealed the trabecular structure and the lateral profile of the bones. 3. Calcium was chemically estimated and expressed as weight of the element per unit volume of the whole bone mass (that is, of anatomical bone including soft marrow tissue). It ranged from 38 to 102 milligrams per cubic centimetre of bone. In 75 per cent of the cases the range was 50-84 milligrams per cubic centimetre. High calcium values were mostly encountered in young adults, and the calcium per unit volume tended to diminish with age; but a wide range of calcium was still encountered in the older subjects and a better correlation with age was achieved by radiographic density. Both calcium content and radiographic density tended to be higher in the male than in the female bones at all ages. 4. The results of both calcium and radiographic density showed a smooth distribution curve, though skewed through the inclusion in the series of more older people with less mineralised bones; the absence of a double peak in these curves suggests that the examinations were made on a homogeneous population and does not indicate a separate pathological group of osteoporotic subjects. 5. Arbitrary standards must be used to distinguish osteoporotic from normal bones, since neither radiological measurement or chemical assay, nor histological assessment, reveals a point at which the two groups can be separated. In the present series it seemed to us satisfactory to regard as abnormal all bones showing a radiographic density of five or less step-wedge units, and by this standard nineteen of the 100 cases (eight male, eleven female) were deemed to be osteoporotic. Histological examination excluded other forms of bone rarefaction. 6. The regression of calcium on the density measurements proved to be statistically significant and was not affected either by age or by the number of days in bed during the last illness. A small difference between the sexes was apparent, there being slightly less calcium in female than in male bones of equal radiographic density. Provided this is taken into account, the radiographic density scale can be used to predict the calcium content of vertebral bone specimens and should prove a rapid and accurate method in a survey of osteoporosis in post-mortem room material


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1475 - 1483
7 Nov 2020
Oliver WM Searle HKC Ng ZH Wickramasinghe NRL Molyneux SG White TO Clement ND Duckworth AD

Aims

The aim of this study was to determine the current incidence and epidemiology of humeral diaphyseal fractures. The secondary aim was to explore variation in patient and injury characteristics by fracture location within the humeral diaphysis.

Methods

Over ten years (2008 to 2017), all adult patients (aged ≥ 16 years) sustaining an acute fracture of the humeral diaphysis managed at the study centre were retrospectively identified from a trauma database. Patient age, sex, medical/social background, injury mechanism, fracture classification, and associated injuries were recorded and analyzed.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 294 - 298
1 Feb 2021
Hadeed MM Prakash H Yarboro SR Weiss DB

Aims

The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols.

Methods

A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 155 - 161
1 Feb 2020
McMahon SE Diamond OJ Cusick LA

Aims

Complex displaced osteoporotic acetabular fractures in the elderly are associated with high levels of morbidity and mortality. Surgical options include either open reduction and internal fixation alone, or combined with total hip arthroplasty (THA). There remains a cohort of severely comorbid patients who are deemed unfit for extensive surgical reconstruction and are treated conservatively. We describe the results of a coned hemipelvis reconstruction and THA inserted via a posterior approach to the hip as the primary treatment for this severely high-risk cohort.

Methods

We have prospectively monitored a series of 22 cases (21 patients) with a mean follow-up of 32 months (13 to 59).


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 33 - 41
1 Jan 2020
Norman JG Brealey S Keding A Torgerson D Rangan A

Aims

The aim of this study was to explore whether time to surgery affects functional outcome in displaced proximal humeral fractures

Methods

A total of 250 patients presenting within three weeks of sustaining a displaced proximal humeral fracture involving the surgical neck were recruited at 32 acute NHS hospitals in the United Kingdom between September 2008 and April 2011. Of the 125 participants, 109 received surgery (fracture fixation or humeral head replacement) as per randomization. Data were included for 101 and 67 participants at six-month and five-year follow-up, respectively. Oxford Shoulder Scores (OSS) collected at six, 12, and 24 months and at three, four, and five years following randomization was plotted against time to surgery. Long-term recovery was explored by plotting six-month scores against five-year scores and agreement was illustrated with a Bland-Altman plot.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 512 - 521
1 May 2019
Carter TH Duckworth AD White TO

Abstract

The medial malleolus, once believed to be the primary stabilizer of the ankle, has been the topic of conflicting clinical and biomechanical data for many decades. Despite the relevant surgical anatomy being understood for almost 40 years, the optimal treatment of medial malleolar fractures remains unclear, whether the injury occurs in isolation or as part of an unstable bi- or trimalleolar fracture configuration. Traditional teaching recommends open reduction and fixation of medial malleolar fractures that are part of an unstable injury. However, there is recent evidence to suggest that nonoperative management of well-reduced fractures may result in equivalent outcomes, but without the morbidity associated with surgery. This review gives an update on the relevant anatomy and classification systems for medial malleolar fractures and an overview of the current literature regarding their management, including surgical approaches and the choice of implants.

Cite this article: Bone Joint J 2019;101-B:512–521.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1550 - 1556
1 Dec 2019
Mc Colgan R Dalton DM Cassar-Gheiti AJ Fox CM O’Sullivan ME

Aims

The aim of this study was to examine trends in the management of fractures of the distal radius in Ireland over a ten-year period, and to determine if there were any changes in response to the English Distal Radius Acute Fracture Fixation Trial (DRAFFT).

Patients and Methods

Data was grouped into annual intervals from 2008 to 2017. All adult inpatient episodes that involved emergency surgery for fractures of the distal radius were included


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1447 - 1458
1 Nov 2019
Chatziagorou G Lindahl H Kärrholm J

Aims

We investigated patient characteristics and outcomes of Vancouver type B periprosthetic fractures treated with femoral component revision and/or osteosynthesis.

Patients and Methods

The study utilized data from the Swedish Hip Arthroplasty Register (SHAR) and information from patient records. We included all primary total hip arthroplasties (THAs) performed in Sweden since 1979, and undergoing further surgery due to Vancouver type B periprosthetic femoral fracture between 2001 and 2011. The primary outcome measure was any further reoperation between 2001 and 2013. Cross-referencing with the National Patient Register was performed in two stages, in order to identify all surgical procedures not recorded on the SHAR.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 260 - 265
1 Mar 2019
Lee SH Han SS Yoo BM Kim JW

Aims

The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients.

Patients and Methods

We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH).


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 478 - 483
1 Apr 2019
Borg T Hernefalk B Hailer NP

Aims

Displaced, comminuted acetabular fractures in the elderly are increasingly common, but there is no consensus on whether they should be treated non-surgically, surgically with open reduction and internal fixation (ORIF), or with acute total hip arthroplasty (THA). A combination of ORIF and acute THA, an approach called ’combined hip procedure’ (CHP), has been advocated and our aim was to compare the outcome after CHP or ORIF alone.

Patients and Methods

A total of 27 patients with similar acetabular fractures (severe acetabular impaction with or without concomitant femoral head injury) with a mean age of 72.2 years (50 to 89) were prospectively followed for a minimum of two years. In all, 14 were treated with ORIF alone and 13 were treated with a CHP. Hip joint and patient survival were estimated. Operating times, blood loss, radiological outcomes, and patient-reported outcomes were assessed.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 502 - 511
1 May 2019
Lidder S Epstein DJ Scott G

Aims

Short-stemmed femoral implants have been used for total hip arthroplasty (THA) in young and active patients to conserve bone, provide physiological loading, and reduce the incidence of thigh pain. Only short- to mid-term results have been presented and there have been concerns regarding component malalignment, incorrect sizing, and subsidence. This systematic review reports clinical and radiological outcomes, complications, revision rates, and implant survival in THA using short-stemmed femoral components.

Materials and Methods

A literature review was performed using the EMBASE, Medline, and Cochrane databases. Strict inclusion and exclusion criteria were used to identify studies reporting clinical and radiological follow-up for short-stemmed hip arthroplasties.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1565 - 1571
1 Dec 2018
Kristensen TB Dybvik E Furnes O Engesæter LB Gjertsen J

Aims

The aim of this large registry-based study was to compare mid-term survival rates of cemented femoral stems of different designs used in hemiarthroplasty for a fracture of the femoral neck.

Patients and Methods

From the Norwegian Hip Fracture Register (NHFR), 20 532 primary cemented bipolar hemiarthroplasties, which were undertaken in patients aged > 70 years with a femoral neck fracture between 2005 and 2016, were included. Polished tapered stems (n = 12 065) (Exeter and CPT), straight stems (n = 5545) (Charnley, Charnley Modular, and Spectron EF), and anatomical stems (n = 2922) (Lubinus SP2) were included. The survival of the implant with any reoperation as the endpoint was calculated using the Kaplan–Meier method and hazard ratios (HRs), and the different indications for reoperation were calculated using Cox regression analysis.


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1303 - 1309
1 Oct 2018
Nodzo SR Chang C Carroll KM Barlow BT Banks SA Padgett DE Mayman DJ Jerabek SA

Aims

The aim of this study was to evaluate the accuracy of implant placement when using robotic assistance during total hip arthroplasty (THA).

Patients and Methods

A total of 20 patients underwent a planned THA using preoperative CT scans and robotic-assisted software. There were nine men and 11 women (n = 20 hips) with a mean age of 60.8 years (sd 6.0). Pelvic and femoral bone models were constructed by segmenting both preoperative and postoperative CT scan images. The preoperative anatomical landmarks using the robotic-assisted system were matched to the postoperative 3D reconstructions of the pelvis. Acetabular and femoral component positions as measured intraoperatively and postoperatively were evaluated and compared.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 516 - 521
1 Apr 2018
Qian L Jiang C Sun P Xu D Wang Y Fu M Zhong S Ouyang J

Aims

The aim of this study was to compare the peak pull-out force (PPF) of pedicle-lengthening screws (PLS) and traditional pedicle screws (TPS) using instant and cyclic fatigue testing.

Materials and Methods

A total of 60 lumbar vertebrae were divided into six groups: PLS submitted to instant pull-out and fatigue-resistance testing (groups A1 and A2, respectively), TPS submitted to instant pull-out and fatigue-resistance testing (groups B1 and B2, respectively) and PLS augmented with 2 ml polymethylmethacrylate, submitted to instant pull-out and fatigue-resistance testing (groups C1 and C2, respectively). The PPF and normalized PPF (PPFn) for bone mineral density (BMD) were compared within and between all groups.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 951 - 957
1 Jul 2017
Poole WEC Wilson DGG Guthrie HC Bellringer SF Freeman R Guryel E Nicol SG

Aims

Fractures of the distal femur can be challenging to manage and are on the increase in the elderly osteoporotic population. Management with casting or bracing can unacceptably limit a patient’s ability to bear weight, but historically, operative fixation has been associated with a high rate of re-operation. In this study, we describe the outcomes of fixation using modern implants within a strategy of early return to function.

Patients and Methods

All patients treated at our centre with lateral distal femoral locking plates (LDFLP) between 2009 and 2014 were identified. Fracture classification and operative information including weight-bearing status, rates of union, re-operation, failure of implants and mortality rate, were recorded.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 818 - 823
1 Jun 2017
Kodama A Mizuseki T Adachi N

Aims

We assessed the long-term (more than ten-year) outcomes of the Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis (RA).

Materials and Methods

We reviewed 41 elbows (Larsen Grade IV, n = 21; Grade V, n = 20) in 31 patients with RA who had undergone a Kudo type-5 total elbow arthroplasty (TEA) between 1994 and 2003, and had been followed up for more than ten years. The humeral component was cementless and the all-polyethylene ulnar component cemented in every patient. Clinical outcome was assessed using the Mayo elbow performance score. We calculated the revision rate and evaluated potential risk factors for revision. The duration of follow-up was a mean 141 months (120 to 203).


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 964 - 972
1 Jul 2017
Duckworth AD Clement ND McEachan JE White TO Court-Brown CM McQueen MM

Aims

The aim of this prospective randomised controlled trial was to compare non-operative and operative management for acute isolated displaced fractures of the olecranon in patients aged ≥ 75 years.

Patients and Methods

Patients were randomised to either non-operative management or operative management with either tension-band wiring or fixation with a plate. They were reviewed at six weeks, three and six months and one year after the injury. The primary outcome measure was the Disabilities of the Arm, Shoulder and Hand (DASH) score at one year.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1475 - 1480
1 Nov 2015
Inngul C Blomfeldt R Ponzer S Enocson A

The aim of this randomised controlled study was to compare functional and radiological outcomes between modern cemented and uncemented hydroxyapatite coated stems after one year in patients treated surgically for a fracture of the femoral neck. A total of 141 patients aged > 65 years were included. Patients were randomised to be treated with a cemented Exeter stem or an uncemented Bimetric stem. The patients were reviewed at four and 12 months.

The cemented group performed better than the uncemented group for the Harris hip score (78 vs 70.7, p = 0.004) at four months and for the Short Musculoskeletal Function Assesment Questionnaire dysfunction score at four (29.8 vs 39.2, p = 0.007) and 12 months (22.3 vs 34.9, p = 0.001). The mean EQ-5D index score was better in the cemented group at four (0.68 vs 0.53, p = 0.001) and 12 months (0.75 vs 0.58, p = < 0.001) follow-up. There were nine intra-operative fractures in the uncemented group and none in the cemented group.

In conclusion, our data do not support the use of an uncemented hydroxyapatite coated stem for the treatment of displaced fractures of the femoral neck in the elderly.

Cite this article: Bone Joint J 2015;97-B:1475–80.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1411 - 1416
1 Oct 2015
Li Y Yang S Chen H Kao Y Tu Y

We evaluated the impact of lumbar instrumented circumferential fusion on the development of adjacent level vertebral compression fractures (VCFs). Instrumented posterior lumbar interbody fusion (PLIF) has become a popular procedure for degenerative lumbar spine disease. The immediate rigidity produced by PLIF may cause more stress and lead to greater risk of adjacent VCFs. However, few studies have investigated the relationship between PLIF and the development of subsequent adjacent level VCFs.

Between January 2005 and December 2009, a total of 1936 patients were enrolled. Of these 224 patients had a new VCF and the incidence was statistically analysed with other covariants. In total 150 (11.1%) of 1348 patients developed new VCFs with PLIF, with 108 (72%) cases at adjacent segment. Of 588 patients, 74 (12.5%) developed new subsequent VCFs with conventional posterolateral fusion (PLF), with 37 (50%) patients at an adjacent level. Short-segment fusion, female and age older than 65 years also increased the development of new adjacent VCFs in patients undergoing PLIF. In the osteoporotic patient, more rigid fusion and a higher stress gradient after PLIF will cause a higher adjacent VCF rate.

Cite this article: Bone Joint J 2015;97-B:1411–16.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1662 - 1666
1 Dec 2013
Parker L Garlick N McCarthy I Grechenig S Grechenig W Smitham P

The AO Foundation advocates the use of partially threaded lag screws in the fixation of fractures of the medial malleolus. However, their threads often bypass the radiodense physeal scar of the distal tibia, possibly failing to obtain more secure purchase and better compression of the fracture.

We therefore hypothesised that the partially threaded screws commonly used to fix a medial malleolar fracture often provide suboptimal compression as a result of bypassing the physeal scar, and proposed that better compression of the fracture may be achieved with shorter partially threaded screws or fully threaded screws whose threads engage the physeal scar.

We analysed compression at the fracture site in human cadaver medial malleoli treated with either 30 mm or 45 mm long partially threaded screws or 45 mm fully threaded screws. The median compression at the fracture site achieved with 30 mm partially threaded screws (0.95 kg/cm2 (interquartile range (IQR) 0.8 to 1.2) and 45 mm fully threaded screws (1.0 kg/cm2 (IQR 0.7 to 2.8)) was significantly higher than that achieved with 45 mm partially threaded screws (0.6 kg/cm2 (IQR 0.2 to 0.9)) (p = 0.04 and p < 0.001, respectively). The fully threaded screws and the 30mm partially threaded screws were seen to engage the physeal scar under an image intensifier in each case.

The results support the use of 30 mm partially threaded or 45 mm fully threaded screws that engage the physeal scar rather than longer partially threaded screws that do not. A 45 mm fully threaded screw may in practice offer additional benefit over 30 mm partially threaded screws in increasing the thread count in the denser paraphyseal region.

Cite this article: Bone Joint J 2013;95-B:1662–6.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1489 - 1496
1 Nov 2016
Konan S Sandiford N Unno F Masri BS Garbuz DS Duncan CP

Fractures around total knee arthroplasties pose a significant surgical challenge. Most can be managed with osteosynthesis and salvage of the replacement. The techniques of fixation of these fractures and revision surgery have evolved and so has the assessment of outcome. This specialty update summarises the current evidence for the classification, methods of fixation, revision surgery and outcomes of the management of periprosthetic fractures associated with total knee arthroplasty.

Cite this article: Bone Joint J 2016;98-B:1489–96.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1406 - 1409
1 Oct 2013
Wähnert D Lange JH Schulze M Gehweiler D Kösters C Raschke MJ

The augmentation of fixation with bone cement is increasingly being used in the treatment of severe osteoporotic fractures. We investigated the influence of bone quality on the mechanics of augmentation of plate fixation in a distal femoral fracture model (AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral models were randomly assigned to either an augmented or a non-augmented group. Fixation was performed using a locking compression plate. In the augmented group additionally 1 ml of bone cement was injected into the screw hole before insertion of the screw. Biomechanical testing was performed in axial sinusoidal loading. Augmentation significantly reduced the cut-out distance in the osteoporotic models by about 67% (non-augmented mean 0.30 mm (sd 0.08) vs augmented 0.13 mm (sd 0.06); p = 0.017). There was no statistical reduction in this distance following augmentation in the non-osteoporotic models (non-augmented mean 0.15 mm (sd 0.02) vs augmented 0.15 mm (sd 0.07); p = 0.915). In the osteoporotic models, augmentation significantly increased stability (p = 0.017).

Cite this article: Bone Joint J 2013;95-B:1406–9.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1099 - 1105
1 Aug 2016
Weiser L Dreimann M Huber G Sellenschloh K Püschel K Morlock MM Rueger JM Lehmann W

Aims

Loosening of pedicle screws is a major complication of posterior spinal stabilisation, especially in the osteoporotic spine. Our aim was to evaluate the effect of cement augmentation compared with extended dorsal instrumentation on the stability of posterior spinal fixation.

Materials and Methods

A total of 12 osteoporotic human cadaveric spines (T11-L3) were randomised by bone mineral density into two groups and instrumented with pedicle screws: group I (SHORT) separated T12 or L2 and group II (EXTENDED) specimen consisting of T11/12 to L2/3. Screws were augmented with cement unilaterally in each vertebra. Fatigue testing was performed using a cranial-caudal sinusoidal, cyclic (1.0 Hz) load with stepwise increasing peak force.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1272 - 1278
1 Oct 2006
Giannoudis PV Schneider E

Despite advances in the prevention and treatment of osteoporotic fractures, their prevalence continues to increase. Their operative treatment remains a challenge for the surgeon, often with unpredictable outcomes. This review highlights the current aspects of management of these fractures and focuses on advances in implant design and surgical technique.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 54 - 59
1 Jan 2016
González Della Valle A Sharrock N Barlow M Caceres L Go G Salvati EA

We describe our technique and rationale using hybrid fixation for primary total hip arthroplasty (THA) at the Hospital for Special Surgery. Modern uncemented acetabular components have few screw holes, or no holes, polished inner surfaces, improved locking mechanisms, and maximised thickness and shell-liner conformity. Uncemented sockets can be combined with highly cross-linked polyethylene liners, which have demonstrated very low wear and osteolysis rates after ten to 15 years of implantation. The results of cement fixation with a smooth or polished surface finished stem have been excellent, virtually eliminating complications seen with cementless fixation like peri-operative femoral fractures and thigh pain. Although mid-term results of modern cementless stems are encouraging, the long-term data do not show reduced revision rates for cementless stems compared with cemented smooth stems. In this paper we review the conduct of a hybrid THA, with emphasis on pre-operative planning, surgical technique, hypotensive epidural anaesthesia, and intra-operative physiology.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):54–9.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 57 - 62
1 Nov 2013
Stulberg SD Patel RM

Conventional uncemented femoral implants provide dependable long-term fixation in patients with a wide range of functional requirements. Yet challenges associated with proximal–distal femoral dimensional mismatch, preservation of bone stock, and minimally invasive approaches have led to exploration into alternative implant designs. Short stem designs focusing on a stable metaphyseal fit have emerged to address these issues in total hip replacement (THR). Uncemented metaphyseal-engaging short stem implants are stable and are associated with proximal bone remodeling closer to the metaphysis when compared with conventional stems and they also have comparable clinical performances. Short stem metaphyseal-engaging implants can meet the goals of a successful THR, including tolerating a high level of patient function, as well as durable fixation.

Cite this article: Bone Joint J 2013;95-B, Supple A:57–62.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1107 - 1112
1 Aug 2012
Bugler KE Watson CD Hardie AR Appleton P McQueen MM Court-Brown CM White TO

Techniques for fixation of fractures of the lateral malleolus have remained essentially unchanged since the 1960s, but are associated with complication rates of up to 30%. The fibular nail is an alternative method of fixation requiring a minimal incision and tissue dissection, and has the potential to reduce the incidence of complications.

We reviewed the results of 105 patients with unstable fractures of the ankle that were fixed between 2002 and 2010 using the Acumed fibular nail. The mean age of the patients was 64.8 years (22 to 95), and 80 (76%) had significant systemic medical comorbidities. Various different configurations of locking screw were assessed over the study period as experience was gained with the device. Nailing without the use of locking screws gave satisfactory stability in only 66% of cases (4 of 6). Initial locking screw constructs rendered between 91% (10 of 11) and 96% (23 of 24) of ankles stable. Overall, seven patients had loss of fixation of the fracture and there were five post-operative wound infections related to the distal fibula. This lead to the development of the current technique with a screw across the syndesmosis in addition to a distal locking screw. In 21 patients treated with this technique there have been no significant complications and only one superficial wound infection. Good fracture reduction was achieved in all of these patients. The mean physical component Short-Form 12, Olerud and Molander score, and American Academy of Orthopaedic Surgeons Foot and Ankle outcome scores at a mean of six years post-injury were 46 (28 to 61), 65 (35 to 100) and 83 (52 to 99), respectively. There have been no cases of fibular nonunion.

Nailing of the fibula using our current technique gives good radiological and functional outcomes with minimal complications, and should be considered in the management of patients with an unstable ankle fracture.