Advertisement for orthosearch.org.uk
Results 1 - 32 of 32
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 238 - 244
1 Mar 1990
Ivarsson I Myrnerts R Gillquist J

On three occasions we have reviewed a series of knees after high tibial osteotomy for osteoarthritis: 99 were reviewed at one to two years; 81 at a mean of 5.7 years; and 65 at a mean of 11.9 years. At one to two years and at 5.7 years over 50% were good and over 75% acceptable. At 11.9 years, 43% were good and 60% acceptable. We determined the mechanical axis through the knee in maximum varus and maximum valgus; significantly better results were found if a mean angulation of 3 degrees to 7 degrees of valgus had been achieved at operation. We also measured intercondylar distances under varus and valgus stress, and found no significant lateral compartment narrowing. The best results were seen in knees with pre-operative grade I or grade II osteoarthritis and valgus deviation after osteotomy.


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1367 - 1372
1 Aug 2021
Plancher KD Brite JE Briggs KK Petterson SC

Aims. The patient-acceptable symptom state (PASS) is a level of wellbeing, which is measured by the patient. The aim of this study was to determine if the proportion of patients who achieved an acceptable level of function (PASS) after medial unicompartmental knee arthroplasty (UKA) was different based on the status of the anterior cruciate ligament (ACL) at the time of surgery. Methods. A total of 114 patients who underwent UKA for isolated medial osteoarthritis (OA) of the knee were included in the study. Their mean age was 65 years (SD 10). No patient underwent a bilateral procedure. Those who had undergone ACL reconstruction during the previous five years were excluded. The Knee injury Osteoarthritis Outcome Score Activities of Daily Living (KOOS ADL) function score was used as the primary outcome measure with a PASS of 87.5, as described for total knee arthroplasty (TKA). Patients completed all other KOOS subscales, Lysholm score, the Western Ontario and McMaster Universities Osteoarthritis Index, and the Veterans Rand 12-item health survey score. Failure was defined as conversion to TKA. Results. Survivorship at ten years was 97% in both the ACL-deficient and ACL-intact groups. The mean survival was 16.1 years (95% confidence interval (CI) 15.3 to 16.8) for the ACL-deficient group and 15.6 years (95% CI 14.8 to 16.361) for the ACL-intact group (p = 0.878). At a mean of nine years (SD 3.5) in the ACL-deficient group, 32 patients (87%) reached the PASS for the KOOS ADL. In the ACL-intact group, at a mean of 8.6 years (SD 3) follow-up, 63 patients (85%) reached PASS for the KOOS ADL. There was no significant difference in the percentage of patients who reached PASS for all KOOS subscales and Lysholm between the two groups. Conclusion. PASS was achieved in 85% of all UKAs for KOOS ADL, similar to reports for TKA. Fixed-bearing, medial, non-robotically-assisted UKA resulted in 97% survival at ten years in both the ACL-deficient and ACL-intact groups. There was no significant difference in all outcomes between the two groups. Understanding PASS will allow better communication between surgeons and patients to improve the surgical management of patients with single compartment OA of the knee. This study provides mid- to long-term data supporting the use of PASS to document outcomes following UKA. PASS was met in more than 85% of patients with no differences between ACL-deficient and ACL-intact knees at a mean follow-up of nine years. Cite this article: Bone Joint J 2021;103-B(8):1367–1372


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1033 - 1040
1 Aug 2020
Kennedy JA Mohammad HR Yang I Mellon SJ Dodd CAF Pandit HG Murray DW

Aims. To report mid- to long-term results of Oxford mobile bearing domed lateral unicompartmental knee arthroplasty (UKA), and determine the effect of potential contraindications on outcome. Methods. A total of 325 consecutive domed lateral UKAs undertaken for the recommended indications were included, and their functional and survival outcomes were assessed. The effects of age, weight, activity, and the presence of full-thickness erosions of cartilage in the patellofemoral joint on outcome were evaluated. Results. Median follow-up was seven years (3 to 14), and mean age at surgery was 65 years (39 to 90). Median Oxford Knee Score (OKS) was 43 (interquartile range (IQR) 37 to 47), with 260 (80%) achieving a good or excellent score (OKS > 34). Revisions occurred in 34 (10%); 14 (4%) were for dislocation, of which 12 had no recurrence following insertion of a new bearing, and 12 (4%) were revised for medial osteoarthritis (OA). Ten-year survival was 85% (95% confidence interval (CI) 79 to 90, at risk 72). Age, weight, activity, and patellofemoral erosions did not have a significant effect on the clinical outcome or survival. Conclusion. Domed lateral UKA provides a good alternative to total knee arthroplasty (TKA) in the management of lateral compartment OA. Although dislocation is relatively easy to treat successfully, the dislocation rate of 4% is high. It is recommended that the stability of the bearing is assessed intraoperatively. If the bearing can easily be displaced, the fixed rather than the mobile bearing version of the Oxford lateral tibial component should be inserted instead. Younger age, heavier weight, high activity, and patellofemoral erosions did not detrimentally affect outcome, so should not be considered contraindications. Cite this article: Bone Joint J 2020;102-B(8):1033–1040


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 9 - 15
1 Oct 2015
Parratte S Ollivier M Lunebourg A Abdel MP Argenson J

Partial knee arthroplasty (PKA), either medial or lateral unicompartmental knee artroplasty (UKA) or patellofemoral arthroplasty (PFA) are a good option in suitable patients and have the advantages of reduced operative trauma, preservation of both cruciate ligaments and bone stock, and restoration of normal kinematics within the knee joint. However, questions remain concerning long-term survival. The goal of this review article was to present the long-term results of medial and lateral UKA, PFA and combined compartmental arthroplasty for multicompartmental disease. Medium- and long-term studies suggest reasonable outcomes at ten years with survival greater than 95% in UKA performed for medial osteoarthritis or osteonecrosis, and similarly for lateral UKA, particularly when fixed-bearing implants are used. Disappointing long-term outcomes have been observed with the first generation of patellofemoral implants, as well as early Bi-Uni (ie, combined medial and lateral UKA) or Bicompartmental (combined UKA and PFA) implants due to design and fixation issues. Promising short- and med-term results with the newer generations of PFAs and bicompartmental arthroplasties will require long-term confirmation. Cite this article: Bone Joint J 2015;97-B(10 Suppl A):9–15


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 467 - 472
1 Apr 2014
Nakamura E Okamoto N Nishioka H Karasugi T Hirose J Mizuta H

We report the long-term outcome of 33 patients (37 knees) who underwent proximal tibial open-wedge osteotomy with hemicallotasis (HCO) for medial osteoarthritis of the knee between 1995 and 2000. Among these, 29 patients with unilateral HCO were enrolled and 19 were available for review at a mean of 14.2 years (10 to 15.7) post-operatively. For these 19 patients, the mean Hospital for Special Surgery knee score was 60 (57 to 62) pre-operatively and 85 (82 to 87) at final follow-up (p < 0.001; paired t-test). The femorotibial angle and tibial inclination angle (IA) were measured at short-term follow-up, one to four years post-operatively, and showed no significant subsequent changes. The clinical scores and radiological measurements showed little change over time. One patient required conversion to total knee replacement during this time. These results suggest that the coronal angle achieved at operation is maintained at long-term follow up after HCO without alteration of the IA, providing a good long-term clinical outcome. Cite this article: Bone Joint J 2014;96-B:467–72


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 476 - 478
1 Apr 2011
Kang S Smith TO De Rover WBS Walton NP

There has been debate about the role of unicompartmental knee replacement in the presence of radiologically identifiable degenerative changes of the patellofemoral joint. We studied 195 knees in 163 patients in whom an Oxford unicompartmental knee replacement had been performed for medial osteoarthritis between January 2004 and July 2007. The mean age of the patients was 66 years (51 to 93). The degree of degenerative change of the patellofemoral joint was assessed using Jones’ criteria. Functional outcome was assessed at a mean of 3.4 years (2 to 7) post-operatively, using the Oxford knee score and the Short-form 12 score. Degenerative changes of the patellofemoral joint were seen pre-operatively in 125 knees (64%) on the skyline radiographs. There was no statistically significant difference in the Oxford knee or Short-form 12 scores between those patients who had patellofemoral osteoarthritis pre-operatively and those who did not (p = 0.22 and 0.54, respectively). These results support the opinion expressed at the designer’s hospital that degenerative changes of the patellofemoral joint in isolation should not be considered to be a contraindication to medial Oxford unicompartmental knee replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 807 - 810
1 Nov 1992
Emerson R Head W Peters P

We reviewed two similar groups of patients with medial osteoarthritis of the knee treated by unicompartmental arthroplasty. The group receiving an Oxford meniscal-bearing implant, with no medial release, showed significantly better mechanical alignment than that receiving a fixed-bearing implant. Under-correction, with its ominous mechanical implications, was much more common with the fixed-bearing design. Over-correction was rare and was seen in both designs about equally. Degenerative stenosis of the intercondylar notch was common and appeared to put the anterior cruciate ligament at risk of rupture, especially after correction of the varus deformity. We consider that postoperative leg alignment and soft-tissue balance after unicompartmental knee replacement are determined more by the implant design and the surgical technique than by any variation in soft-tissue contracture. Release of the medial collateral ligament is not necessary for realignment, but a generous notchplasty is often needed to allow normal anterior cruciate ligament function


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 45 - 49
1 Jan 2001
Robertsson O Knutson K Lewold S Lidgren L

A total of 10474 unicompartmental knee arthroplasties was performed for medial osteoarthritis in Sweden between 1986 and 1995. We sought to establish whether the number of operations performed in an orthopaedic unit affected the incidence of revision. Three different implants were analysed: one with a high revision rate, known to have unfavourable mechanical and design properties; a prosthesis which is technically demanding with a known increased rate of revision; and the most commonly used unicompartmental device. Most of the units performed relatively few unicompartmental knee arthroplasties per year and there was an association between the mean number carried out and the risk of later revision. The effect of the mean number of operations per year on the risk of revision varied. The technically demanding implant was most affected, that most commonly used less so, and the outcome of the unfavourable design was not influenced by the number of operations performed. For unicompartmental arthroplasty, the long-term results are related to the number performed by the unit, probably expressing the standards of management in selecting the patients and performing the operation


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 983 - 985
1 Sep 2004
Rajasekhar C Das S Smith A

We report the outcome of 135 knees with anteromedial osteoarthritis in which the Oxford meniscal-bearing unicompartmental arthroplasty was inserted in a district general hospital by a single surgeon. All the knees had an intact anterior cruciate ligament, a correctable varus deformity and the lateral compartment was uninvolved or had only minor osteoarthritis. The mean follow-up was 5.82 years (2 to 12). Using revision as the end-point, the outcome for every knee was established. Five knees have been revised giving a cumulative rate of survival of the prosthesis at ten years of 94.04% (95% confidence interval 84.0 to 97.8). Knee rating and patient function were assessed using the modified Knee Society scoring system. The mean knee score was 92.2 (51 to 100) and the mean functional score 76.2 (51 to 100). The survival of the implant is comparable to that reported by the designers of the prosthesis and not significantly different from that for total knee replacement. Unicompartmental knee replacement offers a viable alternative in patients with medial osteoarthritis. Appropriate selection of patients and good surgical technique are the key factors


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 43 - 47
1 Jan 2004
Ritter MA Faris PM Thong AE Davis KE Meding JB Berend ME

Interest in unicompartmental knee arthroplasty (UKA) for the treatment of medial compartment osteoarthritis has increased in recent years with apparent improvement in the long-term results. This is a result of improved surgical technique, patient selection, and implant design. In an effort further to improve patient selection we analysed the relationship between the pre-operative alignment of the knee and the anatomical findings at the time of surgery. We compared these findings with the indications for UKA. From 4021 total knee arthroplasties we compared intra-operative observations with the pre-operative clinical data in order to identify knees with isolated, medial, compartment changes, which would have been ideal candidates for UKA. We found that only 247 of the knees (6.1%) met anatomical qualifications for isolated, medial, unicompartmental osteoarthritis, and of these, only 168 (4.3%) met clinical standards ideal for UKA. Pre-operative alignment showed a significant relationship with patterns of disease. Logistic regression revealed a relationship between pre-operative alignment and intra-operative findings resembling a Gaussian distribution. Patients with a pre-operative varus alignment of 7° were slightly more likely to be selected for UKA. But the further the anatomical alignment in either direction varies from 7° of varus, the more unlikely it is for the knee to exhibit a disease pattern of isolated, medial, unicompartmental osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 444 - 448
1 May 1999
Magyar G Ahl TL Vibe P Toksvig-Larsen S Lindstrand A

We describe the results of 50 operations carried out on 46 patients with medial osteoarthritis of the knee of Ahlbäck grade 1 to 3. Patients were randomised either to a closed-wedge high tibial osteotomy (HTO) or an open-wedge procedure based on the hemicallotasis technique (HCO). Their median age was 55 years (38 to 68). The preoperative median hip-knee-ankle (HKA) angle was 171° (164 to 176) in the HTO group and 173° (165 to 179) in the HCO group. After six weeks, the median HKA angle was 185° (176 to 194) in the HTO group and 184° (181 to 188) in the HCO group. In the HTO group, seven patients were within the range of 182° to 186° compared with 21 in the HCO group (p < 0.001). One year later, ten HTO patients were within this range while the HKA angulation in the HCO group was unchanged. At two years the numbers were 11 and 18, respectively. We evaluated the clinical results on the Hospital for Special Surgery, Lysholm and Wallgren-Tegner activity scores, and patients completed part of the Nottingham Health Profile questionnaire. An impartial observer at the two-year follow-up concluded that all scores had improved, but found no clinical differences between the groups


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 240 - 248
1 Mar 2024
Kim SE Kwak J Ro DH Lee MC Han H

Aims

The aim of this study was to evaluate whether achieving medial joint opening, as measured by the change in the joint line convergence angle (∆JLCA), is a better predictor of clinical outcomes after high tibial osteotomy (HTO) compared with the mechanical axis deviation, and to find individualized targets for the redistribution of load that reflect bony alignment, joint laxity, and surgical technique.

Methods

This retrospective study analyzed 121 knees in 101 patients. Patient-reported outcome measures (PROMs) were collected preoperatively and one year postoperatively, and were analyzed according to the surgical technique (opening or closing wedge), postoperative mechanical axis deviation (deviations above and below 10% from the target), and achievement of medial joint opening (∆JLCA > 1°). Radiological parameters, including JLCA, mechanical axis deviation, and the difference in JLCA between preoperative standing and supine radiographs (JLCAPD), an indicator of medial soft-tissue laxity, were measured. Cut-off points for parameters related to achieving medial joint opening were calculated from receiver operating characteristic (ROC) curves.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 351 - 356
1 Mar 2009
Parratte S Argenson JA Pearce O Pauly V Auquier P Aubaniac J

We retrospectively reviewed 35 cemented unicompartmental knee replacements performed for medial unicompartmental osteoarthritis of the knee in 31 patients ≤50 years old (mean 46, 31 to 49). Patients were assessed clinically and radiologically using the Knee Society scores at a mean follow-up of 9.7 years (5 to 16) and survival at 12 years was calculated. The mean Knee Society Function Score improved from 54 points (25 to 64) pre-operatively to 89 (80 to 100) post-operatively (p < 0.0001). Six knees required revision, four for polyethylene wear treated with an isolated exchange of the tibial insert, one for aseptic loosening and one for progression of osteoarthritis. The 12-year survival according to Kaplan-Meier was 80.6% with revision for any reason as the endpoint. Despite encouraging clinical results, polyethylene wear remains a major concern affecting the survival of unicompartmental knee replacement in patients younger than 50


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 374 - 379
1 Mar 2010
Kendrick BJL Rout R Bottomley NJ Pandit H Gill HS Price AJ Dodd CAF Murray DW

With medial unicompartmental osteoarthritis (OA) there is occasionally a full-thickness ulcer of the cartilage on the medial side of the lateral femoral condyle. It is not clear whether this should be considered a contraindication to unicompartmental knee replacement (UKR). The aim of this study was to determine why these ulcers occur, and whether they compromise the outcome of UKR. Case studies of knees with medial OA suggest that cartilage lesions on the medial side of the lateral condyle are caused by impingement on the lateral tibial spine as a result of the varus deformity and tibial subluxation. Following UKR the varus and the subluxation are corrected, so that impingement is prevented and the damaged part of the lateral femoral condyle is not transmitting load. An illustrative case report is presented. Out of 769 knees with OA of the medial compartment treated with the Oxford UKR, 59 (7.7%) had partial-thickness cartilage loss and 20 (2.6%) had a full-thickness cartilage deficit on the medial side of the lateral condyle. The mean Oxford Knee Score (OKS) at the last follow-up at a mean of four years was 41.9 (13 to 48) in those with partial-thickness cartilage loss and 41.0 (20 to 48) in those with full-thickness loss. In those with normal or superficially damaged cartilage the mean was 39.5 (5 to 48) and 39.7 (8 to 48), respectively. There were no statistically significant differences between the pre-operative OKS, the final review OKS or of change in the score in the various groups. We conclude that in medial compartment OA, damage to the medial side of the lateral femoral condyle is caused by impingement on the tibial spine and should not be considered a contraindication to an Oxford UKR, even if there is extensive full-thickness ulceration of the cartilage


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 610 - 618
1 Apr 2021
Batailler C Bordes M Lording T Nigues A Servien E Calliess T Lustig S

Aims

Ideal component sizing may be difficult to achieve in unicompartmental knee arthroplasty (UKA). Anatomical variants, incremental implant size, and a reduced surgical exposure may lead to over- or under-sizing of the components. The purpose of this study was to compare the accuracy of UKA sizing with robotic-assisted techniques versus a conventional surgical technique.

Methods

Three groups of 93 medial UKAs were assessed. The first group was performed by a conventional technique, the second group with an image-free robotic-assisted system (Image-Free group), and the last group with an image-based robotic arm-assisted system, using a preoperative CT scan (Image-Based group). There were no demographic differences between groups. We compared six parameters on postoperative radiographs to assess UKA sizing. Incorrect sizing was defined by an over- or under-sizing greater than 3 mm.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 716 - 726
1 Jun 2020
Scott CEH Holland G Krahelski O Murray IR Keating JF Keenan OJF

Aims

This study aims to determine the proportion of patients with end-stage knee osteoarthritis (OA) possibly suitable for partial (PKA) or combined partial knee arthroplasty (CPKA) according to patterns of full-thickness cartilage loss and anterior cruciate ligament (ACL) status.

Methods

A cross-sectional analysis of 300 consecutive patients (mean age 69 years (SD 9.5, 44 to 91), mean body mass index (BMI) 30.6 (SD 5.5, 20 to 53), 178 female (59.3%)) undergoing total knee arthroplasty (TKA) for Kellgren-Lawrence grade ≥ 3 knee OA was conducted. The point of maximal tibial bone loss on preoperative lateral radiographs was determined as a percentage of the tibial diameter. At surgery, Lachman’s test and ACL status were recorded. The presence of full-thickness cartilage loss within 16 articular surface regions (two patella, eight femoral, six tibial) was recorded.


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 435 - 442
1 Apr 2019
Zambianchi F Franceschi G Rivi E Banchelli F Marcovigi A Nardacchione R Ensini A Catani F

Aims

The purpose of this multicentre observational study was to investigate the association between intraoperative component positioning and soft-tissue balancing on short-term clinical outcomes in patients undergoing robotic-arm assisted unicompartmental knee arthroplasty (UKA).

Patients and Methods

Between 2013 and 2016, 363 patients (395 knees) underwent robotic-arm assisted UKAs at two centres. Pre- and postoperatively, patients were administered Knee Injury and Osteoarthritis Score (KOOS) and Forgotten Joint Score-12 (FJS-12). Results were stratified as “good” and “bad” if KOOS/FJS-12 were more than or equal to 80. Intraoperative, post-implantation robotic data relative to CT-based components placement were collected and classified. Postoperative complications were recorded.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 894 - 903
1 Jul 2017
Bonnin MP Saffarini M Nover L van der Maas J Haeberle C Hannink G Victor J

Aims

The morphometry of the distal femur was largely studied to improve bone-implant fit in total knee arthroplasty (TKA), but little is known about the asymmetry of the posterior condyles. This study aimed to investigate the dimensions of the posterior condyles and the influence of externally rotating the femoral component on potential prosthetic overhang or under-coverage.

Patients and Methods

We analysed the shape of 110 arthritic knees at the time of primary TKA using pre-operative CT scans. The height and width of each condyle were measured at the posterior femoral cut in neutral position, and in 3º and 5º of external rotation, using both central and medial referencing systems. We compared the morphological characteristics with those of 14 TKA models.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 623 - 631
1 May 2017
Blaney J Harty H Doran E O’Brien S Hill J Dobie I Beverland D

Aims

Our aim was to examine the clinical and radiographic outcomes in 257 consecutive Oxford unicompartmental knee arthroplasties (OUKAs) (238 patients), five years post-operatively.

Patients and Methods

A retrospective evaluation was undertaken of patients treated between April 2008 and October 2010 in a regional centre by two non-designing surgeons with no previous experience of UKAs. The Oxford Knee Scores (OKSs) were recorded and fluoroscopically aligned radiographs were assessed post-operatively at one and five years.


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 28 - 33
1 Oct 2016
Lum ZC Lombardi AV Hurst JM Morris MJ Adams JB Berend KR

Aims

Since redesign of the Oxford phase III mobile-bearing unicompartmental knee arthroplasty (UKA) femoral component to a twin-peg design, there has not been a direct comparison to total knee arthroplasty (TKA). Thus, we explored differences between the two cohorts.

Patients and Methods

A total of 168 patients (201 knees) underwent medial UKA with the Oxford Partial Knee Twin-Peg. These patients were compared with a randomly selected group of 177 patients (189 knees) with primary Vanguard TKA. Patient demographics, Knee Society (KS) scores and range of movement (ROM) were compared between the two cohorts. Additionally, revision, re-operation and manipulation under anaesthesia rates were analysed.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1454 - 1459
1 Nov 2006
Brouwer RW Bierma-Zeinstra SMA van Raaij TM Verhaar JAN

A prospective, randomised, controlled trial compared two different techniques of high tibial osteotomy with a lateral closing wedge or a medial opening wedge, stabilised by a Puddu plate. The clinical outcome and radiological results were examined at one year.

The primary outcome measure was the achievement of an overcorrection of valgus of 4°. Secondary outcome measures were the severity of pain (visual analogue scale), knee function (Hospital for Special Surgery score), and walking distance.

Between January 2001 and April 2004, 92 patients were randomised to one or other of the techniques. At follow-up at one year the post-operative hip-knee-ankle angle was 3.4° (± 3.6° sd) valgus after a closing wedge and 1.3° (± 4.7° sd) of valgus after an opening wedge. The adjusted mean difference of 2.1° was significant (p = 0.02). The deviation from 4° of valgus alignment was 2.7° (± 2.4° sd) in the closing wedge and 4.0° (± 3.6° sd) in the opening-wedge groups. The adjusted mean difference of 1.67° was also significant (p = 0.01).

The severity of pain, knee score and walking ability improved in both groups, but the difference was not significant.

Because of pain, the staples required removal in 11 (23%) patients in the closing-wedge group and a Puddu plate was removed in 27 (60%) patients in the opening-wedge group. This difference was significant (p < 0.001).

We conclude that closing-wedge osteotomy achieves a more accurate correction with less morbidity, although both techniques had improved the function of the knee at one year after the procedure.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1214 - 1221
1 Sep 2014
d’Entremont AG McCormack RG Horlick SGD Stone TB Manzary MM Wilson DR

Although it is clear that opening-wedge high tibial osteotomy (HTO) changes alignment in the coronal plane, which is its objective, it is not clear how this procedure affects knee kinematics throughout the range of joint movement and in other planes.

Our research question was: how does opening-wedge HTO change three-dimensional tibiofemoral and patellofemoral kinematics in loaded flexion in patients with varus deformity?Three-dimensional kinematics were assessed over 0° to 60° of loaded flexion using an MRI method before and after opening-wedge HTO in a cohort of 13 men (14 knees). Results obtained from an iterative statistical model found that at six and 12 months after operation, opening-wedge HTO caused increased anterior translation of the tibia (mean 2.6 mm, p <  0.001), decreased proximal translation of the patella (mean –2.2 mm, p <  0.001), decreased patellar spin (mean –1.4°, p < 0.05), increased patellar tilt (mean 2.2°, p < 0.05) and changed three other parameters. The mean Western Ontario and McMaster Universities Arthritis Index improved significantly (p < 0.001) from 49.6 (standard deviation (sd) 16.4) pre-operatively to a mean of 28.2 (sd 16.6) at six months and a mean of 22.5 (sd 14.4) at 12 months.

The three-dimensional kinematic changes found may be important in explaining inconsistency in clinical outcomes, and suggest that measures in addition to coronal plane alignment should be considered.

Cite this article: Bone Joint J 2014; 96-B:1214–21.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1193 - 1197
1 Sep 2008
El-Azab H Halawa A Anetzberger H Imhoff AB Hinterwimmer S

Radiographs of 110 patients who had undergone 120 high tibial osteotomies (60 closed-wedge, 60 open-wedge) were assessed for posterior tibial slope before and after operation, and before removal of the hardware. In the closed-wedge group the mean slope was 5.7° (sd 3.8) before and 2.4° (sd 3.9) immediately after operation, and 2.4° (sd 3.4) before removal of the hardware. In the open-wedge group, these values were 5.0° (sd 3.7), 7.7° (sd 4.3) and 8.1° (sd 3.9) respectively, when stabilised with a non-locking plate, and 7.7° (sd 3.5), 9.4° (sd 4.1) and 9.1° (sd 3.8), when stabilised with a locking plate. The reduction in slope (−2.7° (sd 4.1)) in the closed-wedge group and the increase (+2.5° (sd 3.4), in the open-wedge group was significantly different before and after operation (p = 0.002, p = 0.003). In no group were the changes in slope directly after operation and before removal of the hardware significant (p > 0.05). There was no correlation between the amount of correction in the frontal plane and the post-operative change in slope.

Posterior tibial slope decreases after closed-wedge high tibial osteotomy and increases after an open-wedge procedure because of the geometry of the proximal tibia. The changes in the slope are stable over time, emphasising the influence of the operative procedure rather than of the implant.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1204 - 1208
1 Sep 2013
Kerens B Boonen B Schotanus MGM Lacroix H Emans PJ Kort NP

Although it has been suggested that the outcome after revision of a unicondylar knee replacement (UKR) to total knee replacement (TKR) is better when the mechanism of failure is understood, a comparative study on this subject has not been undertaken.

A total of 30 patients (30 knees) who underwent revision of their unsatisfactory UKR to TKR were included in the study: 15 patients with unexplained pain comprised group A and 15 patients with a defined cause for pain formed group B. The Oxford knee score (OKS), visual analogue scale for pain (VAS) and patient satisfaction were assessed before revision and at one year after revision, and compared between the groups.

The mean OKS improved from 19 (10 to 30) to 25 (11 to 41) in group A and from 23 (11 to 45) to 38 (20 to 48) in group B. The mean VAS improved from 7.7 (5 to 10) to 5.4 (1 to 8) in group A and from 7.4 (2 to 9) to 1.7 (0 to 8) in group B. There was a statistically significant difference between the mean improvements in each group for both OKS (p = 0.022) and VAS (p = 0.002). Subgroup analysis in group A, performed in order to define a patient factor that predicts outcome of revision surgery in patients with unexplained pain, showed no pre-operative differences between both subgroups.

These results may be used to inform patients about what to expect from revision surgery, highlighting that revision of UKR to TKR for unexplained pain generally results in a less favourable outcome than revision for a known cause of pain.

Cite this article: Bone Joint J 2013;95-B:1204–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 54 - 60
1 Jan 2006
Pandit H Jenkins C Barker K Dodd CAF Murray DW

This prospective study describes the complications and survival of the first 688 Phase 3 Oxford medial unicompartmental knee replacements implanted using a minimally-invasive technique by two surgeons and followed up independently. None was lost to follow-up. We had carried out 132 of the procedures more than five years ago. The clinical assessment of 101 of these which were available for review at five years is also presented.

Nine of the 688 knees were revised: four for infection, three for dislocation of the bearing and two for unexplained pain. A further seven knees (1%) required other procedures: four had a manipulation under anaesthesia, two an arthroscopy and one a debridement for superficial infection. The survival rate at seven years was 97.3% (95% confidence interval 5.3). At five years, 96% of the patients had a good or excellent American Knee Society score, the mean Oxford knee score was 39 and the mean flexion was 133°. This study demonstrates that the minimally-invasive Oxford unicompartmental knee replacement is a reliable and effective procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1234 - 1240
1 Sep 2012
Willcox NMJ Clarke JV Smith BRK Deakin AH Deep K

We compared lower limb coronal alignment measurements obtained pre- and post-operatively with long-leg radiographs and computer navigation in patients undergoing primary total knee replacement (TKR). A series of 185 patients had their pre- and post-implant radiological and computer-navigation system measurements of coronal alignment compared using the Bland-Altman method. The study included 81 men and 104 women with a mean age of 68.5 years (32 to 87) and a mean body mass index of 31.7 kg/m2 (19 to 49). Pre-implant Bland–Altman limits of agreement were -9.4° to 8.6° with a repeatability coefficient of 9.0°. The Bland–Altman plot showed a tendency for the radiological measurement to indicate a higher level of pre-operative deformity than the corresponding navigation measurement. Post-implant limits of agreement were -5.0° to 5.4° with a repeatability coefficient of 5.2°. The tendency for valgus knees to have greater deformity on the radiograph was still seen, but was weaker for varus knees.

The alignment seen or measured intra-operatively during TKR is not necessarily the same as the deformity seen on a standing long-leg radiograph either pre- or post-operatively. Further investigation into the effect of weight-bearing and surgical exposure of the joint on the mechanical femorotibial angle is required to enable the most appropriate intra-operative alignment to be selected.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1210 - 1216
1 Sep 2011
Mitsuyasu H Matsuda S Fukagawa S Okazaki K Tashiro Y Kawahara S Nakahara H Iwamoto Y

We investigated whether the extension gap in total knee replacement (TKR) would be changed when the femoral component was inserted. The extension gap was measured with and without the femoral component in place in 80 patients with varus osteoarthritis undergoing posterior-stabilised TKR. The effect of a post-operative increase in the size of the femoral posterior condyles was also evaluated. The results showed that placement of the femoral component significantly reduced the medial and lateral extension gaps by means of 1.0 mm and 0.9 mm, respectively (p < 0.0001). The extension gap was reduced when a larger femoral component was selected relative to the thickness of the resected posterior condyle. When the post-operative posterior lateral condyle was larger than that pre-operatively, 17 of 41 knees (41%) showed a decrease in the extension gap of > 2.0 mm. When a specially made femoral trial component with a posterior condyle enlarged by 4 mm was tested, the medial and lateral extension gaps decreased further by means of 2.1 mm and 2.8 mm, respectively.

If the thickness of the posterior condyle is expected to be larger than that pre-operatively, it should be recognised that the extension gap is likely to be altered. This should be taken into consideration when preparing the extension gap.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1186 - 1192
1 Sep 2008
Lyu S

The outcome of arthroscopic medial release of 255 knees in 173 patients for varying grades of osteoarthritis involving the medial compartment is reported. All operations were performed by a single surgeon between January 2001 and May 2003. The Knee Society score for pain and the patient’s subjective satisfaction were used for the outcome evaluation. Overall, satisfactory outcome was reported for 197 knees (77.3%) and the mean Knee Society score for pain improved from 17.6 (95% confidence interval, 16.7 to 18.5), pre-operatively to 39.4 (95% confidence interval, 37.9 to 41.1) (p < 0.001). There were minor manageable complications of persistent effusion in 16 knees and prolonged wound discomfort in 11. In total, 15 of the 21 knees with poor results were converted to total knee replacements and two other patients (three knees) were offered this option after a mean period of 16 months.

Based on these observations arthroscopic medial release is an effective treatment for osteoarthritis of the medial compartment of the knee joint and can be expected to reduce the pain in the majority of patients for at least four years post-operatively.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1356 - 1361
1 Oct 2012
Streit MR Walker T Bruckner T Merle C Kretzer JP Clarius M Aldinger PR Gotterbarm T

The Oxford mobile-bearing unicompartmental knee replacement (UKR) is an effective and safe treatment for osteoarthritis of the medial compartment. The results in the lateral compartment have been disappointing due to a high early rate of dislocation of the bearing. A series using a newly designed domed tibial component is reported.

The first 50 consecutive domed lateral Oxford UKRs in 50 patients with a mean follow-up of three years (2.0 to 4.3) were included. Clinical scores were obtained prospectively and Kaplan-Meier survival analysis was performed for different endpoints. Radiological variables related to the position and alignment of the components were measured.

One patient died and none was lost to follow-up. The cumulative incidence of dislocation was 6.2% (95% confidence interval (CI) 2.0 to 17.9) at three years. Survival using revision for any reason and aseptic revision was 94% (95% CI 82 to 98) and 96% (95% CI 85 to 99) at three years, respectively. Outcome scores, visual analogue scale for pain and maximum knee flexion showed a significant improvement (p < 0.001). The mean Oxford knee score was 43 (sd 5.3), the mean Objective American Knee Society score was 91 (sd 13.9) and the mean Functional American Knee Society score was 90 (sd 17.5). The mean maximum flexion was 127° (90° to 145°). Significant elevation of the lateral joint line as measured by the proximal tibial varus angle (p = 0.04) was evident in the dislocation group when compared with the non-dislocation group.

Clinical results are excellent and short-term survival has improved when compared with earlier series. The risk of dislocation remains higher using a mobile-bearing UKR in the lateral compartment when compared with the medial compartment. Patients should be informed about this complication. To avoid dislocations, care must be taken not to elevate the lateral joint line.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1522 - 1528
1 Nov 2012
Wallander H Saebö M Jonsson K Bjönness T Hansson G

We investigated 60 patients (89 feet) with a mean age of 64 years (61 to 67) treated for congenital clubfoot deformity, using standardised weight-bearing radiographs of both feet and ankles together with a functional evaluation. Talocalcaneal and talonavicular relationships were measured and the degree of osteo-arthritic change in the ankle and talonavicular joints was assessed. The functional results were evaluated using a modified Laaveg-Ponseti score. The talocalcaneal (TC) angles in the clubfeet were significantly lower in both anteroposterior (AP) and lateral projections than in the unaffected feet (p < 0.001 for both views). There was significant medial subluxation of the navicular in the clubfeet compared with the unaffected feet (p < 0.001). Severe osteoarthritis in the ankle joint was seen in seven feet (8%) and in the talonavicular joint in 11 feet (12%). The functional result was excellent or good (≥ 80 points) in 29 patients (48%), and fair or poor (< 80 points) in 31 patients (52%). Patients who had undergone few (0 to 1) surgical procedures had better functional outcomes than those who had undergone two or more procedures (p < 0.001). There was a significant correlation between the functional result and the degree of medial subluxation of the navicular (p < 0.001, r2 = 0.164), the talocalcaneal angle on AP projection (p < 0.02, r2 = 0.025) and extent of osteoarthritis in the ankle joint (p < 0.001).

We conclude that poor functional outcome in patients with congenital clubfoot occurs more frequently in those with medial displacement of the navicular, osteoarthritis of the talonavicular and ankle joints, and a low talocalcaneal angle on the AP projection, and in patients who have undergone two or more surgical procedures. However, the ankle joint in these patients appeared relatively resistant to the development of osteoarthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1548 - 1557
1 Dec 2008
Brinkman J Lobenhoffer P Agneskirchner JD Staubli AE Wymenga AB van Heerwaarden RJ

New developments in osteotomy techniques and methods of fixation have caused a revival of interest of osteotomies around the knee. The current consensus on the indications, patient selection and the factors influencing the outcome after high tibial osteotomy is presented. This paper highlights recent research aimed at joint pressure redistribution, fixation stability and bone healing that has led to improved surgical techniques and a decrease of post-operative time to full weight-bearing.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 310 - 315
1 Mar 2007
Ackroyd CE Newman JH Evans R Eldridge JDJ Joslin CC

We report the mid-term results of a new patellofemoral arthroplasty for established isolated patellofemoral arthritis. We have reviewed the experience of 109 consecutive patellofemoral resurfacing arthroplasties in 85 patients who were followed up for at least five years.

The five-year survival rate, with revision as the endpoint, was 95.8% (95% confidence interval 91.8% to 99.8%). There were no cases of loosening of the prosthesis. At five years the median Bristol pain score improved from 15 of 40 points (interquartile range 5 to 20) pre-operatively, to 35 (interquartile range 20 to 40), the median Melbourne score from 10 of 30 points (interquartile range 6 to 15) to 25 (interquartile range 20 to 29), and the median Oxford score from 18 of 48 points (interquartile range 13 to 24) to 39 (interquartile range 24 to 45). Successful results, judged on a Bristol pain score of at least 20 at five years, occurred in 80% (66) of knees. The main complication was radiological progression of arthritis, which occurred in 25 patients (28%) and emphasises the importance of the careful selection of patients. These results give increased confidence in the use of patellofemoral arthroplasty.