Advertisement for orthosearch.org.uk
Results 1 - 38 of 38
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 904 - 913
1 Nov 1993
Hernigou P Delepine G Goutallier D Julieron A

From 1984 to 1988 we implanted 127 massive allografts irradiated with a dose of 25,000 grays. These were reviewed at a minimum follow-up of three years to determine the effect of irradiation on infection, the complications and the functional result. No bacteriological infection was seen in the 44 patients who had allografts for revision of joint arthroplasty or for a tumour with no adjuvant therapy. For the 83 patients who also had chemotherapy or radiotherapy or both for a bone tumour, the rate of infection was 13%. The major mechanical complications were nonunion in seven grafts (5.5%) and fracture in eight (6%). These rates do not differ greatly from those reported for non-irradiated grafts. Our results suggest that irradiation, which remains the most convenient and acceptable method of sterilisation, does not jeopardize the clinical results


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 887 - 892
1 Nov 1992
Muscolo D Petracchi L Ayerza M Calabrese M

Six massive femoral allografts followed up for 22 to 36 years are described. Three were intercalary, two were osteoarticular and one was a total femoral replacement. Their functional rating according to the Musculoskeletal Tumor Society System (Enneking 1987) averaged 82% (56 to 100). The radiographic score averaged 75% (48 to 100). Four allografts had suffered fractures, but three of these had later united to give good final scores. Our study shows that massive femoral allografts can function well for as long as 36 years


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 378 - 386
1 Mar 2018
Campanacci DA Totti F Puccini S Beltrami G Scoccianti G Delcroix L Innocenti M Capanna R

Aims. After intercalary resection of a bone tumour from the femur, reconstruction with a vascularized fibular graft (VFG) and massive allograft is considered a reliable method of treatment. However, little is known about the long-term outcome of this procedure. The aims of this study were to determine whether the morbidity of this procedure was comparable to that of other reconstructive techniques, if it was possible to achieve a satisfactory functional result, and whether biological reconstruction with a VFG and massive allograft could achieve a durable, long-lasting reconstruction. Patients and Methods. A total of 23 patients with a mean age of 16 years (five to 40) who had undergone resection of an intercalary bone tumour of the femur and reconstruction with a VFG and allograft were reviewed clinically and radiologically. The mean follow-up was 141 months (24 to 313). The mean length of the fibular graft was 18 cm (12 to 29). Full weight-bearing without a brace was allowed after a mean of 13 months (seven to 26). Results. At final follow-up, the mean Musculoskeletal Tumor Society Score of 22 evaluable patients was 94% (73 to 100). Eight major complications, five fractures (21.7%), and three nonunions (13%) were seen in seven patients (30.4%). Revision-free survival was 72.3% at five, ten, and 15 years, with fracture and nonunion needing surgery as failure endpoints. Overall survival, with removal of allograft or amputation as failure endpoints, was 94.4% at five, ten, and 15 years. Discussion. There were no complications needing surgical revision after five years had elapsed from surgery, suggesting that the mechanical strength of the implant improves with time, thereby decreasing the risk of complications. In young patients with an intercalary bone tumour of the femur, combining a VFG and massive allograft may result in a reconstruction that lasts a lifetime. Cite this article: Bone Joint J 2018;100-B:378–86


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1633 - 1639
1 Dec 2018
Zhao Z Yan T Guo W Yang R Tang X Yang Y

Aims. We retrospectively report our experience of managing 30 patients with a primary malignant tumour of the distal tibia; 25 were treated by limb salvage surgery and five by amputation. We compared the clinical outcomes of following the use of different methods of reconstruction. Patients and Methods. There were 19 male and 11 female patients. The mean age of the patients was 19 years (6 to 59) and the mean follow-up was 5.1 years (1.25 to 12.58). Massive allograft was used in 11 patients, and autograft was used in 14 patients. The time to union, the survival time of the reconstruction, complication rate, and functional outcomes following the different surgical techniques were compared. The overall patient survival was also recorded. Results. Out of 14 patients treated with an autograft, 12 (86%) achieved union at both the proximal and distal junctions. The time to union at both junctions of the autograft was significantly shorter than in those treated with an allograft (11.1 vs 17.2 months, p = 0.02; 9.5 vs 16.2 months, p = 0.04). The complication rate of allograft reconstruction was 55%. The five patients treated with an amputation did not have a complication. Out of the 25 patients who were treated with limb salvage, three (12%) developed local recurrence and underwent amputation. The mean functional Musculoskeletal Tumor Society (MSTS) score after autograft reconstruction was higher than after allograft reconstruction (81% vs 67%; p = 0.06), and similar to that after amputation (81% vs 82%; p = 0.82). The two- and five-year overall rates of survival were 83% and 70%, respectively. Conclusions. This consecutive case series supports the safety of limb salvage and the effectiveness of biological reconstruction after the resection of a primary tumour of the distal tibia. Autograft might be a preferable option. In some circumstances, below-knee amputation remains a valid option


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 398 - 399
1 May 1992
Chapman P Villar R

We report the contamination rate in the Cambridge bone bank of 35 consecutive allograft specimens, all harvested in a clean-air environment, using a strict aseptic technique and antibiotic cover. Five of 27 femoral heads taken from living donors and three of eight massive allografts taken from cadavers were found to be contaminated. The contaminated femoral heads were discarded. All massive allografts were rendered sterile by gamma-irradiation. It is important to exclude bacteriological contamination of harvested and banked bone


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1366 - 1372
1 Oct 2009
Abed YY Beltrami G Campanacci DA Innocenti M Scoccianti G Capanna R

We reviewed 25 patients who had undergone resection of a primary bone sarcoma which extended to within 5 cm of the knee with reconstruction by a combination of a free vascularised fibular graft and a massive allograft bone shell. The distal femur was affected in four patients and the proximal tibia in 21. Their mean age at the time of operation was 19.7 years (5 to 52) and the mean follow-up period 140 months (28 to 213). Three vascularised transfers failed. The mean time to union of the fibula was 5.6 months (3 to 10) and of the allograft 19.6 months (10 to 34). Full weight-bearing was allowed at a mean of 21.4 months (14 to 36). The mean functional score at final follow-up was 27.4 (18 to 30) using a modfied 30-point Musculoskeletal Tumour Society rating system. The overall limb-salvage rate was 88%. The results of our study suggest that the combined use of a vascularised fibular graft and allograft is of value as a limb-salvage procedure for intercalary reconstruction after resection of bone tumours around the knee, especially in skeletally immature patients


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 213 - 216
1 Mar 1996
Alexeeff M Mahomed N Morsi E Garbuz D Gross A Latner AJ

We report 11 patients having revision of total hip arthroplasty using massive structural allografts for failure due to sepsis and associated bone loss. All patients had a two-stage reconstruction and the mean follow-up was 47.8 months (24 to 72). Positive cultures were obtained at the first stage in nine of the 11 patients, with Staphylococcus epidermidis being the most common organism. The other two patients had draining sinuses with negative cultures. There was no recurrence of infection in any patient. The mean increase in the modified Harris hip score was 45 and all the grafts appeared to have united to host bone. Two patients required additional procedures, but only one was related to the allograft. Complications included an incomplete sciatic nerve palsy and one case of graft resorption. Our results support the use of massive allografts in failed septic hip arthroplasty in which there is associated bone loss


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 962 - 965
1 Sep 2004
Ammon P Stockley I

A two-stage procedure was carried out on 57 patients with confirmed infection in a hip replacement. Allograft bone was used in the second stage. Pathogenic organisms were identified in all patients. In stage 1, the prosthesis was removed together with infected tissue. Antibiotics were added to customised cement beads. Systemic antibiotics were not used. At the second stage, 45 of the patients had either acetabular impaction grafting, femoral impaction grafting or a combination; 12 had a massive allograft. Eight patients suffered recurrent infection (14%), in six with the original infecting organism. The risk factors for re-infection were multiple previous procedures and highly resistant organisms. We believe that systemic antibiotic therapy should be considered for these patients. Allograft bone is shown to be a useful adjunct in most infected hip replacements with considerable loss of bone stock


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 836 - 841
1 Jun 2012
Frisoni T Cevolani L Giorgini A Dozza B Donati DM

We retrospectively reviewed 101 consecutive patients with 114 femoral tumours treated by massive bone allograft at our institution between 1986 and 2005. There were 49 females and 52 males with a mean age of 20 years (4 to 74). At a median follow-up of 9.3 years (2 to 19.8), 36 reconstructions (31.5%) had failed. The allograft itself failed in 27 reconstructions (24%). Mechanical complications such as delayed union, fracture and failure of fixation were studied. The most adverse factor on the outcome was the use of intramedullary nails, followed by post-operative chemotherapy, resection length > 17 cm and age > 18 years at the time of intervention. The simultaneous use of a vascularised fibular graft to protect the allograft from mechanical complications improved the outcome, but the use of intramedullary cementing was not as successful. In order to improve the strength of the reconstruction and to advance the biology of host–graft integration, we suggest avoiding the use of intramedullary nails and titanium plates, but instead using stainless steel plates, as these gave better results. The use of a supplementary vascularised fibular graft should be strongly considered in adult patients with resection > 17 cm and in those who require post-operative chemotherapy


Aims

The use of frozen tumour-bearing autograft combined with a vascularized fibular graft (VFG) represents a new technique for biological reconstruction of massive bone defect. We have compared the clinical outcomes between this technique and Capanna reconstruction.

Methods

From June 2011 to January 2016 a retrospective study was carried out of patients with primary osteosarcoma of lower limbs who underwent combined biological intercalary reconstruction. Patients were categorized into two groups based on the reconstructive technique: frozen tumour-bearing autograft combined with concurrent VFG (Group 1) and the Capanna method (Group 2). Demographics, operating procedures, oncological outcomes, graft union, limb function, and postoperative complications were compared.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 38 - 41
1 Jan 1996
Gouin F Passuti N Verriele V Delecrin J Bainvel JV

We performed biopsies during reoperation for minor complications in two active young patients 9 and 19 months after massive bone allograft implantation for bone tumour. The grafts were dead and resorption-apposition activity, when present, was predominantly in subperiosteal areas. Inflammatory infiltration was very seldom found. Features considered as ‘microfractures’ or ‘microcracks’ were noted in the cortical ring together with the formation of woven bone, in areas with remodelling. Such cracks are likely to be of mechanical origin and do not inevitably lead to complications


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 382 - 390
1 Feb 2021
Wang H Tang X Ji T Yan T Yang R Guo W

Aims

There is an increased risk of dislocation of the hip after the resection of a periacetabular tumour and endoprosthetic reconstruction of the defect in the hemipelvis. The aim of this study was to determine the rate and timing of dislocation and to identify its risk factors.

Methods

To determine the dislocation rate, we conducted a retrospective single-institution study of 441 patients with a periacetabular tumour who had undergone a standard modular hemipelvic endoprosthetic reconstruction between 2003 and 2019. After excluding ineligible patients, 420 patients were enrolled. Patient-specific, resection-specific, and reconstruction-specific variables were studied using univariate and multivariate analyses.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 538 - 544
1 May 1999
Deijkers RLM Bouma GJ van der Meer-Prins EMW Huysmans PE Taminiau AHM Claas FHJ

We analysed the cellular immune response in ten transplantations of different massive bone allografts, of which five had a poor clinical outcome. Cytotoxic T lymphocytes (CTL) and T helper lymphocytes (TH) against mismatched donor antigens were found in all patients. More importantly, CTL with a high affinity for donor antigens were found in five cases. High-affinity CTL need no CD8 molecule to stabilise the antigen binding and are strongly associated with rejection of heart and corneal transplants. Even after removal of most of the bone-marrow cells, we found high-affinity CTL and high TH frequencies. This T-cell response could be detected over a period of years. We conclude that frozen bone allografts can induce high-affinity donor-specific CTL. The present assay allows qualification and quantification of the levels of CTL and TH in the blood. This approach may be helpful in studying the effect of the immune response on the outcome of the graft


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1626 - 1632
1 Dec 2018
Medellin MR Fujiwara T Tillman RM Jeys LM Gregory J Stevenson JD Parry M Abudu A

Aims

The aim of this paper was to investigate the prognostic factors for local recurrence in patients with pathological fracture through giant cell tumours of bone (GCTB).

Patients and Methods

A total of 107 patients presenting with fractures through GCTB treated at our institution (Royal Orthopaedic Hospital, Birmingham, United Kingdom) between 1995 and 2016 were retrospectively studied. Of these patients, 57 were female (53%) and 50 were male (47%).The mean age at diagnosis was 33 years (14 to 86). A univariate analysis was performed, followed by multivariate analysis to identify risk factors based on the treatment and clinical characteristics.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 973 - 978
1 Jul 2017
Gupta S Kafchinski LA Gundle KR Saidi K Griffin AM Wunder JS Ferguson PC

Aims

Intercalary allografts following resection of a primary diaphyseal tumour have high rates of complications and failures. At our institution intercalary allografts are augmented with intramedullary cement and fixed using compression plating. Our aim was to evaluate their long-term outcomes.

Patients and Methods

A total of 46 patients underwent reconstruction with an intercalary allograft between 1989 and 2014. The patients had a mean age of 32.8 years (14 to 77). The most common diagnoses were osteosarcoma (n = 16) and chondrosarcoma (n = 9). The location of the tumours was in the femur in 21, the tibia in 16 and the humerus in nine. Function was assessed using the Musculoskeletal Tumor Society (MSTS) scoring system and the Toronto Extremity Salvage Score (TESS). The survival of the graft and the overall survival were assessed using the Kaplan-Meier method.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 574 - 580
1 May 2007
Delloye C Cornu O Druez V Barbier O

Bone allografts can be used in any kind of surgery involving bone from minor defects to major bone loss after tumour resection. This review describes the various types of bone grafts and the current knowledge on bone allografts, from procurement and preparation to implantation. The surgical conditions for optimising the incorporation of bone are outlined, and surgeon expectations from a bone allograft discussed.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 522 - 530
1 Apr 2017
Bus MPA van de Sande MAJ Taminiau AHM Dijkstra PDS

Aims

To assess complications and failure mechanisms of osteoarticular allograft reconstructions for primary bone tumours.

Patients and Methods

We retrospectively evaluated 38 patients (28 men, 74%) who were treated at our institution with osteoarticular allograft reconstruction between 1989 and 2010. Median age was 19 years (interquartile range 14 to 32). Median follow-up was 19.5 years (95% confidence interval (CI) 13.0 to 26.1) when 26 patients (68%) were alive. In addition, we systematically searched the literature for clinical studies on osteoarticular allografts, finding 31 studies suitable for analysis. Results of papers that reported on one site exclusively were pooled for comparison.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1430 - 1437
1 Nov 2006
Michalak KA Khoo PPC Yates PJ Day RE Wood DJ

Revision arthroplasty after infection can often be complicated by both extensive bone loss and a relatively high rate of re-infection. Using allograft to address the bone loss in such patients is controversial because of the perceived risk of bacterial infection from the use of avascular graft material. We describe 12 two-stage revisions for infection in which segmental allografts were loaded with antibiotics using iontophoresis, a technique using an electrical potential to drive ionised antibiotics into cortical bone.

Iontophoresis produced high levels of antibiotic in the allograft, which eluted into the surrounding tissues. We postulate that this offers protection from infection in the high-risk peri-operative period. None of the 12 patients who had two-stage revision with iontophoresed allografts had further infection after a mean period of 47 months (14 to 78).


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 867 - 874
1 Jun 2010
Hanna SA Sewell MD Aston WJS Pollock RC Skinner JA Cannon SR Briggs TWR

Segmental resection of malignant bone disease in the femoral diaphysis with subsequent limb reconstruction is a major undertaking. This is a retrospective review of 23 patients who had undergone limb salvage by endoprosthetic replacement of the femoral diaphysis for a primary bone tumour between 1989 and 2005.

There were 16 males and seven females, with a mean age of 41.3 years (10 to 68). The mean overall follow-up was for 97 months (3 to 240), and 120 months (42 to 240) for the living patients. The cumulative patient survival was 77% (95% confidence interval 63% to 95%) at ten years. Survival of the implant, with failure of the endoprosthesis as an endpoint, was 85% at five years and 68% (95% confidence interval 42% to 92%) at ten years. The revision rate was 22% and the overall rate of re-operation was 26%. Complications included deep infection (4%), breakage of the prosthesis (8%), periprosthetic fracture (4%), aseptic loosening (4%), local recurrence (4%) and metastases (17%). The 16 patients who retained their diaphyseal endoprosthesis had a mean Musculoskeletal Tumour Society score of 87% (67% to 93%). They were all able to comfortably perform most activities of daily living.

Femoral diaphyseal endoprosthetic replacement is a viable option for reconstruction following segmental resection of malignant bone disease. It allows immediate weight-bearing, is associated with a good long-term functional outcome, has an acceptable complication and revision rate and, most importantly, does not appear to compromise patient survival.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 853 - 861
1 Jun 2015
Hilven PH Bayliss L Cosker T Dijkstra PDS Jutte PC Lahoda LU Schaap GR Bramer JAM van Drunen GK Strackee SD van Vooren J Gibbons M Giele H van de Sande MAJ

Vascularised fibular grafts (VFGs ) are a valuable surgical technique in limb salvage after resection of a tumour. The primary objective of this multicentre study was to assess the risk factors for failure and complications for using a VFG after resection of a tumour.

The study involved 74 consecutive patients (45 men and 29 women with mean age of 23 years (1 to 64) from four tertiary centres for orthopaedic oncology who underwent reconstruction using a VFG after resection of a tumour between 1996 and 2011. There were 52 primary and 22 secondary reconstructions. The mean follow-up was 77 months (10 to 195).

In all, 69 patients (93%) had successful limb salvage; all of these united and 65 (88%) showed hypertrophy of the graft. The mean time to union differed between those involving the upper (28 weeks; 12 to 96) and lower limbs (44 weeks; 12 to 250). Fracture occurred in 11 (15%), and nonunion in 14 (19%) patients.

In 35 patients (47%) at least one complication arose, with a greater proportion in lower limb reconstructions, non-bridging osteosynthesis, and in children. These complications resulted in revision surgery in 26 patients (35%).

VFG is a successful and durable technique for reconstruction of a defect in bone after resection of a tumour, but is accompanied by a significant risk of complications, that often require revision surgery. Union was not markedly influenced by the need for chemo- or radiotherapy, but should not be expected during chemotherapy. Therefore, restricted weight-bearing within this period is advocated.

Cite this article: Bone Joint J 2015;97-B:853–61.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 686 - 696
1 May 2017
Stihsen C Panotopoulos J Puchner SE Sevelda F Kaider A Windhager R Funovics PT

Aims

Few studies dealing with chondrosarcoma of the pelvis are currently available. Different data about the overall survival and prognostic factors have been published but without a detailed analysis of surgery-related complications. We aimed to analyse the outcome of a series of pelvic chondrosarcomas treated at a single institution, with particular attention to the prognostic factors. Based on a competing risk model, our objective was to identify risk factors for the development of complications.

Patients and Methods

In a retrospective single-centre study, 58 chondrosarcomas (26 patients alive, 32 patients dead) of the pelvis were reviewed. The mean follow-up was 13 years (one week to 23.1 years).


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1106 - 1110
1 Aug 2014
Malhotra R Kiran Kumar GN K. Digge V Kumar V

Giant cell tumour is the most common aggressive benign tumour of the musculoskeletal system and has a high rate of local recurrence. When it occurs in proximity to the hip, reconstruction of the joint is a challenge. Options for reconstruction after wide resection include the use of a megaprosthesis or an allograft-prosthesis composite. We performed a clinical and radiological study to evaluate the functional results of a proximal femoral allograft-prosthesis composite in the treatment of proximal femoral giant cell tumour after wide resection. This was an observational study, between 2006 and 2012, of 18 patients with a mean age of 32 years (28 to 42) and a mean follow-up of 54 months (18 to 79). We achieved excellent outcomes using Harris Hip Score in 13 patients and a good outcome in five. All allografts united. There were no complications such as infection, failure, fracture or resorption of the graft, or recurrent tumour. Resection and reconstruction of giant cell tumours with proximal femoral allograft–prosthesis composite is a better option than using a prosthesis considering preservation of bone stock and excellent restoration of function.

A good result requires demanding bone banking techniques, effective measures to prevent infection and stability at the allograft-host junction.

Cite this article: Bone Joint J 2014; 96-B:1106–10.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1404 - 1410
1 Oct 2014
Wafa H Grimer RJ Jeys L Abudu AT Carter SR Tillman RM

The aim of this study was to evaluate the functional and oncological outcome of extracorporeally irradiated autografts used to reconstruct the pelvis after a P1/2 internal hemipelvectomy.

The study included 18 patients with a primary malignant bone tumour of the pelvis. There were 13 males and five females with a mean age of 24.8 years (8 to 62). Of these, seven had an osteogenic sarcoma, six a Ewing’s sarcoma, and five a chondrosarcoma. At a mean follow-up of 51.6 months (4 to 185), nine patients had died with metastatic disease while nine were free from disease. Local recurrence occurred in three patients all of whom eventually died of their disease. Deep infection occurred in three patients and required removal of their graft in two while the third underwent a hindquarter amputation for extensive flap necrosis.

The mean Musculoskeletal Tumor Society functional score of the 16 patients who could be followed-up for at least 12 months was 77% (50 to 90). Those 15 patients who completed the Toronto Extremity Salvage Score questionnaire had a mean score of 71% (53 to 85).

Extracorporeal irradiation and re-implantation of bone is a valid method of reconstruction after an internal hemipelvectomy. It has an acceptable morbidity and a functional outcome that compares favourably with other available reconstructive techniques.

Cite this article: Bone Joint J 2014;96-B:1404–10


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1258 - 1263
1 Sep 2014
Schuh R Panotopoulos J Puchner SE Willegger M M. Hobusch G Windhager R Funovics PT

Resection of a primary sarcoma of the diaphysis of a long bone creates a large defect. The biological options for reconstruction include the use of a vascularised and non-vascularised fibular autograft.

The purpose of the present study was to compare these methods of reconstruction.

Between 1985 and 2007, 53 patients (26 male and 27 female) underwent biological reconstruction of a diaphyseal defect after resection of a primary sarcoma. Their mean age was 20.7 years (3.6 to 62.4). Of these, 26 (49 %) had a vascularised and 27 (51 %) a non-vascularised fibular autograft. Either method could have been used for any patient in the study. The mean follow-up was 52 months (12 to 259). Oncological, surgical and functional outcome were evaluated. Kaplan–Meier analysis was performed for graft survival with major complication as the end point.

At final follow-up, eight patients had died of disease. Primary union was achieved in 40 patients (75%); 22 (42%) with a vascularised fibular autograft and 18 (34%) a non-vascularised (p = 0.167). A total of 32 patients (60%) required revision surgery. Kaplan–Meier analysis revealed a mean survival without complication of 36 months (0.06 to 107.3, sd 9) for the vascularised group and 88 months (0.33 to 163.9, sd 16) for the non-vascularised group (p = 0.035).

Both groups seem to be reliable biological methods of reconstructing a diaphyseal bone defect. Vascularised autografts require more revisions mainly due to problems with wound healing in distal sites of tumour, such as the foot.

Cite this article: Bone Joint J 2014;96-B:1258–63.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 304 - 309
1 Mar 2009
Kerboull L Hamadouche M Kerboull M

We describe 129 consecutive revision total hip replacements using a Charnley-Kerboull femoral component of standard length with impaction allografting. The mean follow-up was 8.2 years (2 to 16). Additionally, extramedullary reinforcement was performed using struts of cortical allograft in 49 hips and cerclage wires in 30.

There was one intra-operative fracture of the femur but none later. Two femoral components subsided by 5 mm and 8 mm respectively, and were considered to be radiological failures. No further revision of a femoral component was required. The rate of survival of the femoral component at nine years, using radiological failure as the endpoint, was 98%. Our study showed that impaction grafting in association with a Charnley-Kerboull femoral component has a low rate of subsidence. Reconstruction of deficiencies of distal bone with struts of cortical allograft appeared to be an efficient way of preventing postoperative femoral fracture for up to 16 years.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 399 - 405
1 Mar 2014
Zang J Guo W Yang Y Xie L

We report our early experience with the use of a new prosthesis, the Modular Hemipelvic Prosthesis II, for reconstruction of the hemipelvis after resection of a primary malignant peri-acetabular tumour involving the sacroiliac joint.

We retrospectively reviewed the outcome of 17 patients who had undergone resection of a pelvic tumour and reconstruction with this prosthesis between July 2002 and July 2010.

One patient had a type I+II+III+IV resection (ilium + peri-acetabulum + pubis/ischium + sacrum) and 16 had a type I+II+IV resection (ilium + acetabulum + sacrum). The outcome was assessed at a mean follow-up of 33 months (15 to 59). One patient was alive with disease, 11 were alive without disease and five had died of disease. The overall five-year survival rate was 62.4%. Six patients had a local recurrence. The mean Musculoskeletal Tumour Society score was 58% (33 to 77). Deep infection occurred in two patients, problems with wound healing in five and dislocation in one.

For patients with a primary malignant peri-acetabular sarcoma involving the sacroiliac joint, we believe that this new prosthesis is a viable option for reconstruction of the bony defect left following resection of the tumour. It results in a satisfactory functional outcome with an acceptable rate of complications.

Cite this article: Bone Joint J 2014;96-B:399–405.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 73 - 77
1 Jan 2016
Mäkinen TJ Fichman SG Watts E Kuzyk PRT Safir OA Gross AE

An uncemented hemispherical acetabular component is the mainstay of acetabular revision and gives excellent long-term results.

Occasionally, the degree of acetabular bone loss means that a hemispherical component will be unstable when sited in the correct anatomical location or there is minimal bleeding host bone left for biological fixation. On these occasions an alternative method of reconstruction has to be used.

A major column structural allograft has been shown to restore the deficient bone stock to some degree, but it needs to be off-loaded with a reconstruction cage to prevent collapse of the graft. The use of porous metal augments is a promising method of overcoming some of the problems associated with structural allograft. If the defect is large, the augment needs to be protected by a cage to allow ingrowth to occur. Cup-cage reconstruction is an effective method of treating chronic pelvic discontinuity and large contained or uncontained bone defects.

This paper presents the indications, surgical techniques and outcomes of various methods which use acetabular reconstruction cages for revision total hip arthroplasty.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):73–7.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 643 - 648
1 May 2013
Wang J Hsu C Huang C Lin P Chen W

Structural allografts may be used to manage uncontained bone defects in revision total knee replacement (TKR). However, the availability of cadaver grafts is limited in some areas of Asia. The aim of this study was to evaluate the mid-term outcome of the use of femoral head allografts for the reconstruction of uncontained defects in revision TKR, focusing on complications related to the graft.

We retrospectively reviewed 28 patients (30 TKRs) with Anderson Orthopaedic Research Institute (AORI) type 3 bone defects, who underwent revision using femoral head allografts and stemmed components. The mean number of femoral heads used was 1.7 (1 to 3). The allograft–host junctions were packed with cancellous autograft.

At a mean follow-up of 76 months (38 to 136) the mean American Knee Society knee score improved from 37.2 (17 to 60) pre-operatively to 90 (83 to 100) (p < 0.001). The mean function score improved from 26.5 (0 to 50) pre-operatively to 81 (60 to 100) (p < 0.001). All the grafts healed to the host bone. The mean time to healing of the graft was 6.6 months (4 to 16). There have been no complications of collapse of the graft, nonunion, infection or implant loosening. No revision surgery was required.

The use of femoral head allografts in conjunction with a stemmed component and autogenous bone graft in revision TKR in patients with uncontained bone defects resulted in a high rate of healing of the graft with minimal complications and a satisfactory outcome. Longer follow-up is needed to observe the evolution of the graft.

Cite this article: Bone Joint J 2013;95-B:643–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 430 - 435
1 Apr 2008
Biant LC Bruce WJM Assini JB Walker PM Walsh WR

This prospective study presents the ten-year (5 to 16) clinical and radiological results of 55 primary total hip replacements (THR) using a cementless modular femoral component (S-ROM). All patients had a significant anatomical abnormality which rendered the primary THR difficult.

The mean Harris hip score was 36 (12 to 72) pre-operatively, 83 (44 to 100) at five years, and 85 (45 to 99) at ten years. The Western Ontario and McMaster Universities osteoarthritis index (WOMAC) and short-form (SF)-12 scores were recorded from the year 2000. The mean SF-12 score at five years after surgery was 45.24 (22.74 to 56.58) for the physical component and 54.14 (29.20 to 66.61) for the mental component. By ten years the SF-12 scores were 42.86 (21.59 to 58.95) and 51.03 (33.78 to 61.40), respectively. The mean WOMAC score at five years post-operatively was 25 (0 to 59), and at ten years was 27 (2 to 70).

No femoral components were radiologically loose, although five had osteolysis in Gruen zone 1, three had osteolysis in zone 7, and two showed osteolysis in both zones 1 and 7. No osteolysis was observed around or distal to the prosthetic sleeve. No femoral components were revised, although three hips underwent an acetabular revision and two required a liner exchange. At a mean of ten years’ follow-up the S-ROM femoral component implanted for an anatomically difficult primary THR has excellent clinical and radiological results.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 770 - 775
1 Jun 2005
Hsieh P Shih C Chang Y Lee MS Yang W Shih H

We have carried out in 24 patients, a two-stage revision arthroplasty of the hip for infection with massive bone loss. We used a custom-made, antibiotic-loaded cement prosthesis as an interim spacer. Fifteen patients had acetabular deficiencies, eight had segmental femoral bone loss and one had a combined defect.

There was no recurrence of infection at a mean follow-up of 4.2 years (2 to 7). A total of 21 patients remained mobile in the interim period. The mean Merle D’Aubigné and Postel hip score improved from 7.3 points before operation to 13.2 between stages and to 15.8 at the final follow-up. The allograft appeared to have incorporated into the host bone in all patients. Complications included two fractures and one dislocation of the cement prosthesis.

The use of a temporary spacer maintains the function of the joint between stages even when there is extensive loss of bone. Allograft used in revision surgery after septic conditions restores bone stock without the risk of recurrent infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 704 - 709
1 May 2005
Chen TH Chen WM Huang CK

We reviewed 29 patients who had undergone intercalary resection for malignant tumours. Of these, 14 had received segmental allograft reconstruction and 15 extracorporeally-irradiated autograft.

At a mean follow-up of 71 months (24 to 132), 20 were free from disease, five had died and four were alive with pulmonary metastases. Two patients, one with an allograft and one with an irradiated autograft, had a local recurrence. Reconstruction with extracorporeally-irradiated autograft has a significantly lower rate of nonunion (7% vs 43%, p = 0.031) but an insignificantly higher rate of fracture (20% vs 14%, p = 0.535) than that with segmental allograft. Using the Enneking functional evaluation system, the mean postoperative score for the patients without local recurrence was 87% (80% to 96%) and was similar in both groups.

Extracorporeally-irradiated autograft could be an acceptable alternative for reconstruction after intercalary resection, especially in countries where it is difficult to obtain allografts.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 218 - 225
1 Feb 2005
Tsuchiya H Wan SL Sakayama K Yamamoto N Nishida H Tomita K

We describe a method of reconstruction using tumour-bearing autograft treated by liquid nitrogen in 28 patients. The operative technique consisted of en bloc excision of the tumour, removal of soft tissue, curettage of the tumour, drilling and preparation for internal fixation or prosthetic replacement before incubation for 20 minutes in liquid nitrogen, thawing at room temperature for 15 minutes, thawing in distilled water for ten minutes, and internal fixation with an intramedullary nail, plate or composite use of prosthetic replacement. Bone graft or cement was used to augment bone strength when necessary.

The limb function was rated as excellent in 20 patients (71.4%), good in three (10.7%), fair in three (10.7%), and poor in two (7.1%). At the final follow-up six patients had died at a mean of 19.8 months after the operation, while 21 remained free from disease with a mean follow-up of 28.1 months (10 to 54). One patient is alive with disease. Bony union was seen at a mean of 6.7 months after the operation in 26 patients. Complications were encountered in seven patients, including three deep infections, two fractures, and two local recurrences. All were managed successfully. Our results suggest that this is a simple and effective method of biological reconstruction.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1149 - 1157
1 Sep 2006
Khoo PPC Michalak KA Yates PJ Megson SM Day RE Wood DJ

Iontophoresis is a novel technique which may be used to facilitate the movement of antibiotics into the substance of bone using an electrical potential applied externally. We have examined the rate of early infection in allografts following application of this technique in clinical practice. A total of 31 patients undergoing revision arthroplasty or surgery for limb salvage received 34 iontophoresed sequential allografts, of which 26 survived for a minimum of two years. The mean serum antibiotic levels after operation were low (gentamicin 0.37 mg/l (0.2 to 0.5); flucloxacillin 1 mg/l (0 to 1) and the levels in the drains were high (gentamicin 40 mg/l (2.5 to 131); flucloxacillin 17 mg/l (1 to 43). There were no early deep infections. Two late infections were presumed to be haemotogenous; 28 of the 34 allografts were retained. In 12 patients with pre-existing proven infection further infection has not occurred at a mean follow-up of 51 months (24 to 82).


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1215 - 1221
1 Sep 2010
Sakai T Ohzono K Nishii T Miki H Takao M Sugano N

The long-term results of grafting with hydroxyapatite granules for acetabular deficiency in revision total hip replacement are not well known. We have evaluated the results of revision using a modular cup with hydroxyapatite grafting for Paprosky type 2 and 3 acetabular defects at a minimum of ten years’ follow-up. We retrospectively reviewed 49 acetabular revisions at a mean of 135 months (120 to 178). There was one type 2B, ten 2C, 28 3A and ten 3B hips. With loosening as the endpoint, the survival rate was 74.2% (95% confidence interval 58.3 to 90.1). Radiologically, four of the type 3A hips (14%) and six of the type 3B hips (60%) showed aseptic loosening with collapse of the hydroxyapatite layer, whereas no loosening occurred in type 2 hips. There was consolidation of the hydroxyapatite layer in 33 hips (66%). Loosening was detected in nine of 29 hips (31%) without cement and in one of 20 hips (5%) with cement (p = 0.03, Fisher’s exact probability test). The linear wear and annual wear rate did not correlate with loosening.

These results suggest that the long-term results of hydroxyapatite grafting with cement for type 2 and 3A hips are encouraging.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1487 - 1491
1 Nov 2006
Ahlmann ER Menendez LR

Custom-made intercalary endoprostheses may be used for the reconstruction of diaphyseal defects following the resection of bone tumours. The aim of this study was to determine the survival of intercalary endoprostheses with a lap joint design, and to evaluate the clinical results, complications and functional outcome. We retrospectively reviewed six consecutive patients, three of whom underwent limb salvage with intercalary endoprostheses of the tibia, two of the femur, and one of the humerus. Their mean age was 42 years (28 to 64). The mean follow-up was 21.6 months (9 to 58). The humeral prosthesis required revision at 14 months owing to aseptic loosening. There were no implant-related failures. Musculoskeletal Tumour Society functional outcome scores indicated that patients achieved 90% of premorbid function.

Custom intercalary endoprostheses result in reconstructions comparable with, if not better than, those of allografts. Using this design of implant reduces the incidence of early complications and difficulties experienced with previous versions.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1690 - 1694
1 Dec 2010
Scoccianti G Campanacci DA Beltrami G Caldora P Capanna R

Several techniques have been described to reconstruct a mobile wrist joint after resection of the distal radius for tumour. We reviewed our experience of using an osteo-articular allograft to do this in 17 patients with a mean follow-up of 58.9 months (28 to 119).

The mean range of movement at the wrist was 56° flexion, 58° extension, 84° supination and 80° pronation. The mean ISOLS-MSTS score was 86% (63% to 97%) and the mean patient-rated wrist evaluation score was 16.5 (3 to 34). There was no local recurrence or distant metastases. The procedure failed in one patient with a fracture of the graft and an arthrodesis was finally required. Union was achieved at the host-graft interface in all except two cases. No patient reported more than modest non-disabling pain and six reported no pain at all. Radiographs showed early degenerative changes at the radiocarpal joint in every patient.

A functional pain-free wrist can be restored with an osteo-articular allograft after resection of the distal radius for bone tumour, thereby avoiding the donor site morbidity associated with an autograft. These results may deteriorate with time.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 981 - 987
1 Aug 2008
Whittaker JP Dharmarajan R Toms AD

The management of bone loss in revision replacement of the knee remains a challenge despite an array of options available to the surgeon. Bone loss may occur as a result of the original disease, the design of the prosthesis, the mechanism of failure or technical error at initial surgery. The aim of revision surgery is to relieve pain and improve function while addressing the mechanism of failure in order to reconstruct a stable platform with transfer of load to the host bone. Methods of reconstruction include the use of cement, modular metal augmentation of prostheses, custom-made, tumour-type or hinged implants and bone grafting.

The published results of the surgical techniques are summarised and a guide for the management of bone defects in revision surgery of the knee is presented.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 960 - 966
1 Jul 2006
Pluhar GE Turner AS Pierce AR Toth CA Wheeler DL

Critical size defects in ovine tibiae, stabilised with intramedullary interlocking nails, were used to assess whether the addition of carboxymethylcellulose to the standard osteogenic protein-1 (OP-1/BMP-7) implant would affect the implant’s efficacy for bone regeneration. The biomaterial carriers were a ‘putty’ carrier of carboxymethylcellulose and bovine-derived type-I collagen (OPP) or the standard with collagen alone (OPC). These two treatments were also compared to “ungrafted” negative controls. Efficacy of regeneration was determined using radiological, biomechanical and histological evaluations after four months of healing. The defects, filled with OPP and OPC, demonstrated radiodense material spanning the defect after one month of healing, with radiographic evidence of recorticalisation and remodelling by two months. The OPP and OPC treatment groups had equivalent structural and material properties that were significantly greater than those in the ungrafted controls. The structural properties of the OPP- and OPC-treated limbs were equivalent to those of the contralateral untreated limb (p > 0.05), yet material properties were inferior (p < 0.05). Histopathology revealed no residual inflammatory response to the biomaterial carriers or OP-1. The OPP- and OPC-treated animals had 60% to 85% lamellar bone within the defect, and less than 25% of the regenerate was composed of fibrous tissue. The defects in the untreated control animals contained less than 40% lamellar bone and more than 60% was fibrous tissue, creating full cortical thickness defects. In our studies carboxymethylcellulose did not adversely affect the capacity of the standard OP-1 implant for regenerating bone.