Advertisement for orthosearch.org.uk
Results 1 - 30 of 30
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 55 - 63
1 Jan 2020
Hagberg K Ghassemi Jahani S Kulbacka-Ortiz K Thomsen P Malchau H Reinholdt C

Aims. The aim of this study was to describe implant and patient-reported outcome in patients with a unilateral transfemoral amputation (TFA) treated with a bone-anchored, transcutaneous prosthesis. Methods. In this cohort study, all patients with a unilateral TFA treated with the Osseointegrated Prostheses for the Rehabilitation of Amputees (OPRA) implant system in Sahlgrenska University Hospital, Gothenburg, Sweden, between January 1999 and December 2017 were included. The cohort comprised 111 patients (78 male (70%)), with a mean age 45 years (17 to 70). The main reason for amputation was trauma in 75 (68%) and tumours in 23 (21%). Patients answered the Questionnaire for Persons with Transfemoral Amputation (Q-TFA) before treatment and at two, five, seven, ten, and 15 years’ follow-up. A prosthetic activity grade was assigned to each patient at each timepoint. All mechanical complications, defined as fracture, bending, or wear to any part of the implant system resulting in removal or change, were recorded. Results. The Q-TFA scores at two, five, seven, and ten years showed significantly more prosthetic use, better mobility, fewer problems, and an improved global situation, compared with baseline. The survival rate of the osseointegrated implant part (the fixture) was 89% and 72% after seven and 15 years, respectively. A total of 61 patients (55%) had mechanical complications (mean 3.3 (SD 5.76)), resulting in exchange of the percutaneous implant parts. There was a positive relationship between a higher activity grade and the number of mechanical complications. Conclusion. Compared with before treatment, the patient-reported outcome was significantly better and remained so over time. Although osseointegration and the ability to transfer loads over a 15-year period have been demonstrated, a large number of mechanical failures in the external implant parts were found. Since these were related to higher activity, restrictions in activity and improvements to the mechanical properties of the implant system are required. Cite this article: Bone Joint J 2020;102-B(1):55–63


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 114 - 121
1 Jan 2008
Pendegrass CJ Gordon D Middleton CA Sun SNM Blunn GW

Conventional amputation prostheses rely on the attachment of the socket to the stump, which may lead to soft-tissue complications. Intraosseous transcutaneous amputation prostheses (ITAPs) allow direct loading of the skeleton, but their success is limited by infection resulting from breaching of the skin at the interface with the implant. Keratinocytes provide the skin’s primary barrier function, while hemidesmosomes mediate their attachment to natural ITAP analogues. Keratinocytes must attach directly to the surface of the implant. We have assessed the proliferation, morphology and attachment of keratinocytes to four titaniumalloy surfaces in order to determine the optimal topography in vitro. We used immunolocalisation of adhesion complex components, scanning electron microscopy and transmission electron microscopy to assess cell parameters. We have shown that the proliferation, morphology and attachment of keratinocytes are affected by the surface topography of the biomaterials used to support their growth. Smoother surfaces improved adhesion. We postulate that a smooth topography at the point of epithelium-ITAP contact could increase attachment in vivo, producing an effective barrier of infection


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 1 | Pages 79 - 83
1 Jan 1983
Dowd G Linge K Bentley G

The transcutaneous oxygen pressure (tcPO2) was measured by a polarographic technique in the legs of 161 volunteers and compared with the levels found in 62 patients with ischaemic skin due to peripheral vascular disease. The results show that the tcPO2 was related to the degree of ischaemia and, in many cases, was a more accurate guide to the viability of the skin than clinical assessment. Measurement of the transcutaneous oxygen pressure in the leg at the site of amputation in 24 patients with peripheral vascular disease showed that a preoperative level greater than 40 millimetres of mercury at an electrode temperature of 44 degrees Celsius was necessary for the skin of the stump to heal. The technique is simple, non-invasive and reliable. The tcPO2 accurately reflects the physiological and pathological changes in the circulation of the skin. It has potential in many fields of surgery where careful assessment of the viability of the skin is necessary


Aims. The Intraosseous Transcutaneous Amputation Prosthesis (ITAP) may improve quality of life for amputees by avoiding soft-tissue complications associated with socket prostheses and by improving sensory feedback and function. It relies on the formation of a seal between the soft tissues and the implant and currently has a flange with drilled holes to promote dermal attachment. Despite this, infection remains a significant risk. This study explored alternative strategies to enhance soft-tissue integration. Materials and Methods. The effect of ITAP pins with a fully porous titanium alloy flange with interconnected pores on soft-tissue integration was investigated. The flanges were coated with fibronectin-functionalised hydroxyapatite and silver coatings, which have been shown to have an antibacterial effect, while also promoting viable fibroblast growth in vitro. The ITAP pins were implanted along the length of ovine tibias, and histological assessment was undertaken four weeks post-operatively. Results. The porous titanium alloy flange reduced epithelial downgrowth and increased soft-tissue integration compared with the current drilled flange. The addition of coatings did not enhance these effects. Conclusion. These results indicate that a fully porous titanium alloy flange has the potential to increase the soft-tissue seal around ITAP and reduce susceptibility to infection compared with the current design. Cite this article: Bone Joint J 2017;99-B:393–400


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 109 - 112
1 Jan 1988
Finsen V Persen L Lovlien M Veslegaard E Simensen M Gasvann A Benum P

We studied the effect of transcutaneous electrical nerve stimulation (TENS) on stump healing and postoperative and late phantom pain after major amputations of the lower limb. A total of 51 patients were randomised to one of three postoperative treatment regimens: sham TENS and chlorpromazine medication, sham TENS only, and active low frequency TENS. There were fewer re-amputations and more rapid stump healing among below-knee amputees who had received active TENS. Sham TENS had a considerable placebo effect on pain. There were, however, no significant differences in the analgesic requirements or reported prevalence of phantom pain between the groups during the first four weeks. The prevalence of phantom pain after active TENS was significantly lower after four months but not after more than one year


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 465 - 467
1 May 1988
Bongard O Krahenbuhl B

The predictive value of the pedal transcutaneous oxygen tension (tcPO2) and of the distal systolic blood pressure (SBP) in forecasting the necessity for later amputation has been studied in 26 patients suffering from severe chronic ischaemia of the lower limbs. In all these patients vascular surgery had failed or not been possible, and they were threatened by amputation; they suffered from trophic lesions, or pain at rest, or both. The great toe SBP averaged 10 mmHg (range 0 to 60 mmHg) and the pedal tcPO2 10 mmHg (range 2 to 45 mmHg). After six minutes of oxygen inhalation there was an increase in pedal tcPO2 of 9 mmHg (0 to 50 mmHg). After a follow-up period averaging 7 months (range 10 days to 13 months), 13 patients underwent an amputation and nine (five of whom had been amputated) died. The great toe SBP in the patients who required amputation was initially lower than in those who did not. The pedal tcPO2 also was lower in amputated than in non-amputated patients. There was no amputation in the group showing an increase of at least 10 mmHg after six minutes of oxygen inhalation; and conversely, all patients in whom the pedal tcPO2 increased less than 10 mmHg were amputated. Thus increase in the pedal tcPO2 after oxygen inhalation appears the best criterion for estimating the prognosis of severely ischaemic limbs


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 821 - 824
1 Nov 1988
Kristiansen B Kofoed H

A consecutive series of 31 displaced fractures of the proximal humerus were randomly selected for treatment either by closed manipulation or by transcutaneous reduction and external fixation. Follow-up assessed the quality of reduction and healing as well as the functional outcome. The external fixation method gave better reduction, safer healing and superior function


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 423 - 426
1 May 1986
Christensen K Klarke M

In 42 amputations (28 below-knee and 14 above-knee), healing of the stump was found to correlate with the pre-operative transcutaneous oxygen pressure (tcPO2) measured at the planned site of incision. Of 31 patients with a tcPO2 of 30 mmHg or more, 27 healed primarily, three had delayed healing and one failed to heal; of seven patients with values between 20 and 30 mmHg three healed primarily and four had delayed healing; and all four patients with a value below 20 mmHg had stumps which failed to heal and needed reamputation. It is concluded that a tcPO2 of 20 mmHg or more at the intended site of amputation indicates that the wound will heal


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 564 - 569
1 Apr 2012
Pendegrass CJ El-Husseiny M Blunn GW

The success of long-term transcutaneous implants depends on dermal attachment to prevent downgrowth of the epithelium and infection. Hydroxyapatite (HA) coatings and fibronectin (Fn) have independently been shown to regulate fibroblast activity and improve attachment. In an attempt to enhance this phenomenon we adsorbed Fn onto HA-coated substrates. Our study was designed to test the hypothesis that adsorption of Fn onto HA produces a surface that will increase the attachment of dermal fibroblasts better than HA alone or titanium alloy controls. . Iodinated Fn was used to investigate the durability of the protein coating and a bioassay using human dermal fibroblasts was performed to assess the effects of the coating on cell attachment. Cell attachment data were compared with those for HA alone and titanium alloy controls at one, four and 24 hours. Protein attachment peaked within one hour of incubation and the maximum binding efficiency was achieved with an initial droplet of 1000 ng. We showed that after 24 hours one-fifth of the initial Fn coating remained on the substrates, and this resulted in a significant, three-, four-, and sevenfold increase in dermal fibroblast attachment strength compared to uncoated controls at one, four and 24 hours, respectively


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 293 - 302
1 Mar 2024
Vogt B Lueckingsmeier M Gosheger G Laufer A Toporowski G Antfang C Roedl R Frommer A

Aims

As an alternative to external fixators, intramedullary lengthening nails (ILNs) can be employed for distraction osteogenesis. While previous studies have demonstrated that typical complications of external devices, such as soft-tissue tethering, and pin site infection can be avoided with ILNs, there is a lack of studies that exclusively investigated tibial distraction osteogenesis with motorized ILNs inserted via an antegrade approach.

Methods

A total of 58 patients (median age 17 years (interquartile range (IQR) 15 to 21)) treated by unilateral tibial distraction osteogenesis for a median leg length discrepancy of 41 mm (IQR 34 to 53), and nine patients with disproportionate short stature treated by bilateral simultaneous tibial distraction osteogenesis, with magnetically controlled motorized ILNs inserted via an antegrade approach, were retrospectively analyzed. The median follow-up was 37 months (IQR 30 to 51). Outcome measurements were accuracy, precision, reliability, bone healing, complications, and patient-reported outcome assessed by the Limb Deformity-Scoliosis Research Society Score (LD-SRS-30).


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 656 - 658
1 Aug 1988
Johnson D

The viability of three incisions for knee arthroplasty were analysed by transcutaneous estimation of the skin oxygen tension. Wound viability was found to be significantly reduced following knee arthroplasty. The lateral wound edge is more hypoxic than the medial, but there were no significant differences between the three incisions


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 643 - 646
1 Aug 1987
Kristiansen B Kofoed H

A new technique for the treatment of displaced fractures of the proximal humerus is described. Twelve fractures in 11 patients were managed by transcutaneous reduction using a Steinmann pin, and external fixation with a Hoffmann-type neutralising bar connected to two half-pins in the humeral head and three half-pins in the shaft. The pins were removed after four weeks. Two patients sustained redisplacement after a further injury, but in the others reduction was maintained. Two cases of pin-track infection resolved after antibiotics, but delayed union resulted. There were no neurovascular injuries and at follow-up of 6 to 12 months no refractures had been seen. The early functional results were excellent or satisfactory in nine cases


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 5 | Pages 583 - 585
1 Dec 1982
Wredmark T Lundh R

One hundred and seventy-four consecutive patients with symptoms of derangement of the knee were examined with an arthroscope under local anaesthesia using a continuous pressure-irrigation system. A 0.2 per cent prilocaine-saline solution was used as irrigation fluid. In the first 19 patients the serum level of prilocaine was monitored for six hours after the start of irrigation. Eighteen of the 174 patients had a transcutaneous partial meniscectomy at the same time as the examination. All the patients tolerated the examination well. The distension of the knee produced by the pressure-irrigation system provided a high degree of diagnostic accuracy. The serum levels of prilocaine were low throughout the monitoring period reaching a mean peak value of 0.28 micrograms per millilitre after one hour. There were no adverse side-effects. This technique provides a safe and efficient method to meet the increasing demands of arthroscopic procedures of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 40 - 44
1 Jan 2001
Clarke MT Longstaff L Edwards D Rushton N

We have investigated whether the thigh tourniquet used during total knee replacement (TKR) influenced the development of postoperative wound hypoxia and was a cause of delayed wound healing. We allocated randomly 31 patients (31 TKRs) to one of three groups: 1) no tourniquet; 2) tourniquet inflated at low pressure (about 225 mmHg); and 3) tourniquet inflated to high pressure of about 350 mmHg. Wound oxygenation was measured using transcutaneous oxygen electrodes. In the first week after surgery, patients with a tourniquet inflated to a high pressure had greater wound hypoxia than those with a low pressure. Those without a tourniquet also had wound hypoxia, but the degree and duration were less pronounced than in either of the groups with a tourniquet. Use of a tourniquet during TKR can increase postoperative wound hypoxia, especially when inflated to high pressures. Our findings may be relevant to wound healing and the development of wound infection


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 952 - 960
1 Jul 2016
Muderis MA Tetsworth K Khemka A Wilmot S Bosley B Lord SJ Glatt V

Aims

This study describes the Osseointegration Group of Australia’s Accelerated Protocol two-stage strategy (OGAAP-1) for the osseointegrated reconstruction of amputated limbs.

Patients and Methods

We report clinical outcomes in 50 unilateral trans-femoral amputees with a mean age of 49.4 years (24 to 73), with a minimum one-year follow-up. Outcome measures included the Questionnaire for persons with a Trans-Femoral Amputation, the health assessment questionnaire Short-Form-36 Health Survey, the Amputation Mobility Predictor scores presented as K-levels, 6 Minute Walk Test and timed up and go tests. Adverse events included soft-tissue problems, infection, fractures and failure of the implant.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 89 - 94
1 Jan 2016
Cherian JJ Jauregui JJ Leichliter AK Elmallah RK Bhave A Mont MA

The purpose of this study was to evaluate the effect of various non-operative modalities of treatment (transcutaneous electrical nerve stimulation (TENS); neuromuscular electrical stimulation (NMES); insoles and bracing) on the pain of osteoarthritis (OA) of the knee.

We conducted a systematic review according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines to identify the therapeutic options which are commonly adopted for the management of osteoarthritis (OA) of the knee.

The outcome measurement tools used in the different studies were the visual analogue scale and The Western Ontario and McMaster Universities Arthritis Index pain index: all pain scores were converted to a 100-point scale.

A total of 30 studies met our inclusion criteria: 13 on insoles, seven on TENS, six on NMES, and four on bracing. The standardised mean difference (SMD) in pain after treatment with TENS was 1.796, which represented a significant reduction in pain. The significant overall effect estimate for NMES on pain was similar to that of TENS, with a SMD of 1.924. The overall effect estimate of insoles on pain was a SMD of 0.992. The overall effect of bracing showed a significant reduction in pain of 1.34.

Overall, all four non-operative modalities of treatment were found to have a significant effect on the reduction of pain in OA of the knee.

This study shows that non-operative physical modalities of treatment are of benefit when treating OA of the knee. However, much of the literature reviewed evaluates studies with follow-up of less than six months: future work should aim to evaluate patients with longer follow-up.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):89–94.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1369 - 1375
1 Oct 2016
Brodsky JW Kane JM Coleman S Bariteau J Tenenbaum S

Aims

The surgical management of ankle arthritis with tibiotalar arthrodesis is known to alter gait, as compared with normal ankles. The purpose of this study was to assess post-operative gait function with gait before arthrodesis.

Patients and Methods

We prospectively studied 20 patients who underwent three-dimensional gait analysis before and after tibiotalar arthrodesis. Cadence, step length, walking velocity and total support time were assessed. Kinetic parameters, including the moment and power of the ankle in the sagittal plane and hip power were also recorded.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1382 - 1388
1 Oct 2016
Laubscher M Mitchell C Timms A Goodier D Calder P

Aims

Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages.

Patients and Methods

We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 285 - 290
1 Mar 2007
Dowd GSE Hussein R Khanduja V Ordman AJ

Complex regional pain syndrome is characterised by an exaggerated response to injury in a limb with intense prolonged pain, vasomotor disturbance, delayed functional recovery and trophic changes. This review describes the current knowledge of the condition and outlines the methods of treatment available with particular emphasis on the knee.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1581 - 1581
1 Nov 2013
Cook TM

We welcome letters to the Editor concerning articles that have recently been published. Such letters will be subject to the usual stages of selection and editing; where appropriate the authors of the original article will be offered the opportunity to reply.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 487 - 493
1 Apr 2009
Dayer R Assal M

We studied a cohort of 26 diabetic patients with chronic ulceration under the first metatarsal head treated by a modified Jones extensor hallucis longus and a flexor hallucis longus transfer. If the first metatarsal was still plantar flexed following these two transfers, a peroneus longus to the peroneus brevis tendon transfer was also performed. Finally, if ankle dorsiflexion was < 5° with the knee extended, a Strayer-type gastrocnemius recession was performed.

The mean duration of chronic ulceration despite a minimum of six months’ conservative care was 16.2 months (6 to 31). A total of 23 of the 26 patients were available for follow-up at a mean of 39.6 months (12 to 61) after surgery. All except one achieved complete ulcer healing at a mean of 4.4 weeks (2 to 8) after surgery, and there was no recurrence of ulceration under the first metatarsal.

We believe that tendon balancing using modified Jones extensor hallucis longus and flexor hallucis longus transfers, associated in selected cases with a peroneus longus to brevis transfer and/or Strayer procedure, can promote rapid and sustained healing of chronic diabetic ulcers under the first metatarsal head.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1488 - 1494
1 Nov 2007
Gorodetskyi IG Gorodnichenko AI Tursin PS Reshetnyak VK Uskov ON

We undertook a trial on 60 patients with AO 31A2 fractures of the hip who were randomised after stabilisation of the fracture into two equal groups, one of which received post-operative treatment using a non-invasive interactive neurostimulation device and the other with a sham device. All other aspects of their rehabilitation were the same. The treatment was continued for ten days after operation.

Outcome measurements included the use of a visual analogue scale for pain, the brief pain inventory and Ketorolac for post-operative control of pain, and an overall assessment of outcome by the surgeon. There were significantly better results for the patients receiving treatment by active electrical stimulation (repeated measures analysis of variance, p < 0.001). The findings of this pilot trial justify a larger study to determine if these results are more generally applicable.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 756 - 759
1 Jun 2006
Kato N Htut M Taggart M Carlstedt T Birch R

We investigated the effect of delay before nerve repair on neuropathic pain after injury to the brachial plexus. We studied 148 patients, 85 prospectively and 63 retrospectively. The mean number of avulsed spinal nerves was 3.2 (1 to 5). Pain was measured by a linear visual analogue scale and by the peripheral nerve injury scale. Early repair was more effective than delayed repair in the relief from pain and there was a strong correlation between functional recovery and relief from pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 906 - 914
1 Jul 2008
Ayoub MA

Between 2000 and 2006 we performed salvage tibiotalar arthrodesis in 17 diabetic patients (17 ankles) with grossly unstable ankles caused by bimalleolar fractures complicated by Charcot neuro-arthropathy. There were ten women and seven men with a mean age of 61.6 years (57 to 69). A crossed-screw technique was used. Two screws were used in eight patients and three screws in nine. Additional graft from the malleoli was used in all patients. The mean follow-up was 26 months (12 to 48) and the mean time to union was 5.8 months (4 to 8). A stable ankle was achieved in 14 patients (82.4%), nine of whom had bony fusion and five had a stiff fibrous union. The results were significantly better in underweight patients, in those in whom surgery had been performed three to six months after the onset of acute Charcot arthropathy, in those who had received anti-resorptive medication during the acute stage, in those without extensive peripheral neuropathy, and in those with adequate peripheral oxygen saturation (> 95%). The arthrodesis failed because of avascular necrosis of the talus in only three patients (17.6%), who developed grossly unstable, ulcerated hindfeet, and required below-knee amputation.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 398 - 404
1 Mar 2012
Seide K Aljudaibi M Weinrich N Kowald B Jürgens C Müller J Faschingbauer M

In an interdisciplinary project involving electronic engineers and clinicians, a telemetric system was developed to measure the bending load in a titanium internal femoral fixator. As this was a new device, the main question posed was: what clinically relevant information could be drawn from its application? As a first clinical investigation, 27 patients (24 men, three women) with a mean age of 38.4 years (19 to 66) with femoral nonunions were treated using the system. The mean duration of the nonunion was 15.4 months (5 to 69). The elasticity of the plate-callus system was measured telemetrically until union. Conventional radiographs and a CT scan at 12 weeks were performed routinely, and healing was staged according to the CT scans. All nonunions healed at a mean of 21.5 weeks (13 to 37). Well before any radiological signs of healing could be detected, a substantial decrease in elasticity was recorded. The relative elasticity decreased to 50% at a mean of 7.8 weeks (3.5 to 13) and to 10% at a mean of 19.3 weeks (4.5 to 37). At 12 weeks the mean relative elasticity was 28.1% (0% to 56%). The relative elasticity was significantly different between the different healing stages as determined by the CT scans.

Incorporating load measuring electronics into implants is a promising option for the assessment of bone healing. Future application might lead to a reduction in the need for exposure to ionising radiation to monitor fracture healing.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 1 - 9
1 Jan 2012
Robinson CM Seah KTM Chee YH Hindle P Murray IR

Frozen shoulder is commonly encountered in general orthopaedic practice. It may arise spontaneously without an obvious predisposing cause, or be associated with a variety of local or systemic disorders. Diagnosis is based upon the recognition of the characteristic features of the pain, and selective limitation of passive external rotation. The macroscopic and histological features of the capsular contracture are well-defined, but the underlying pathological processes remain poorly understood. It may cause protracted disability, and imposes a considerable burden on health service resources. Most patients are still managed by physiotherapy in primary care, and only the more refractory cases are referred for specialist intervention. Targeted therapy is not possible and treatment remains predominantly symptomatic. However, over the last ten years, more active interventions that may shorten the clinical course, such as capsular distension arthrography and arthroscopic capsular release, have become more popular.

This review describes the clinical and pathological features of frozen shoulder. We also outline the current treatment options, review the published results and present our own treatment algorithm.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 1 - 6
1 Jan 2010
Clifton R Ng CY Nutton RW

We have reviewed the literature to establish the role of lateral retinacular release in the management of disorders of the extensor apparatus of the knee. The scientific evidence for intervention is explored and reports on outcome are discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 1 - 7
1 Jan 2009
Robinson AHN Pasapula C Brodsky JW

A comprehensive review of the literature relating to the pathology and management of the diabetic foot is presented. This should provide a guide for the treatment of ulcers, Charcot neuro-arthropathy and fractures involving the foot and ankle in diabetic patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 280 - 287
1 Mar 2008
Gwilym SE Pollard TCB Carr AJ

The majority of patients with osteoarthritis present to orthopaedic surgeons seeking relief of pain and associated restoration of function. Although our understanding of the physiology of pain has improved greatly over the last 25 years there remain a number of unexplained pain-related observations in patients with osteoarthritis. The understanding of pain in osteoarthritis, its modulation and treatment is central to orthopaedic clinical practice and in this annotation we explore some of the current concepts applicable. We also introduce the concept of the ‘phantom joint’ as a cause for persistent pain after joint replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 778 - 785
1 Jun 2008
Varitimidis SE Basdekis GK Dailiana ZH Hantes ME Bargiotas K Malizos K

In a randomised prospective study, 20 patients with intra-articular fractures of the distal radius underwent arthroscopically- and fluoroscopically-assisted reduction and external fixation plus percutaneous pinning. Another group of 20 patients with the same fracture characteristics underwent fluoroscopically-assisted reduction alone and external fixation plus percutaneous pinning. The patients were evaluated clinically and radiologically at follow-up of 24 months. The Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and modified Mayo wrist score were used at 3, 9, 12 and 24 months postoperatively. In the arthroscopically- and fluoroscopically-assisted group, triangular fibrocartilage complex tears were found in 12 patients (60%), complete or incomplete scapholunate ligament tears in nine (45%), and lunotriquetral ligament tears in four (20%). They were treated either arthroscopically or by open operation. Patients who underwent arthroscopically- and fluoroscopically-assisted treatment had significantly better supination, extension and flexion at all time points than those who had fluoroscopically-assisted surgery. The mean DASH scores were similar for both groups at 24 months, whereas the difference in the mean modified Mayo wrist scores remained statistically significant.

Although the groups are small, it is clear that the addition of arthroscopy to the fluoroscopically-assisted treatment of intra-articular distal radius fractures improves the outcome. Better treatment of associated intra-articular injuries might also have been a reason for the improved outcome.